Viega Visign Instructions For Use Manual

Page 1
for Viega urinal flushing system Visign installation set Model Year built:
8354.2 from 09/2007
en_INT
Visign for More 104 equipment set
Instructions for Use
Page 2
Page 3
Table of contents
1 About these instructions for use 4
1.1
Target groups 4
1.2
Labelling of notes 4
1.3
About this translated version 5
2 Product information 6
2.1
Standards and regulations 6
2.2
Intended use 6
2.2.1
Areas of use 6
2.2.2
Maintenance 6
2.3
Product description 6
2.3.1
Overview 6
2.3.2
Technical data 7
3 Handling 8
3.1
Assembly information 8
3.1.1
Required material and tools 8
3.2
Assembly 8
3.2.1
Insert cartridge valve 8
3.2.2
Mounting the basic panel 9
3.2.3
Mounting the flush plate 10
3.3
Faults, faults and remedy 11
3.4
Care and maintenance 11
3.4.1
Maintenance tips 11
3.4.2
Cleaning cartridge valve 11
3.5
Disposal 12
Table of contents
Page 4
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Page 5
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Page 6
2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
viega.com/standards
.
Regulations from section: Technical data
Scope / Notice Regulations applicable in Ger-
many
Flush flow DIN 3265
Noise class DIN 4109
2.2 Intended use
2.2.1 Areas of use
The equipment set is intended for the actuation of flushes in urinals.
2.2.2 Maintenance
The cartridge valve should be cleaned once a year to ensure fault-free operation. See
Ä Chapter 3.4.2 „Cleaning cartridge valve“ on page 11
2.3
Product description
2.3.1 Overview
1 2 3 4
Fig. 1: Component overview
1 - flush plate 2 - fixing screws 3 - basic panel 4 - cartridge valve
Product information
Page 7
2.3.2 Technical data
The product has the following technical data:
Minimum flow pressure 0.05–0.5 MPa (0.5–5 bar)
Flush flow, see
Ä „Regulations from section: Technical data“ on page 6
0.3–0.7 l/s
Noise class, see
Ä „Regulations from section: Technical data“ on page 6
Class 2
Product information
Page 8
3 Handling
3.1 Assembly information
3.1.1 Required material and tools
The following tools are required for mounting:
n flat screwdriver n spanner (SW 17) n handsaw
3.2 Assembly
3.2.1 Insert cartridge valve
Requirements:
n the pre-wall element has been mounted n the tiling work is completed. n the revision opening is freely accessible n the urinal ceramic has been mounted
Open the shut-off with a screw driver for a few seconds to rinse the pipeline.
Re-close shut-off.
Remove seal (SW 17).
Tool
Handling
Page 9
Place the cartridge valve on straight and carefully screw in (fine thread).
Screw in cartridge valve (SW 17).
Set flush volume.
n inside position: 2 l n outside position: 4 l
Open shut-off valve.
3.2.2 Mounting the basic panel
In the next step, the basic panel of the flush plate must be mounted.
Requirements:
n The installation duct is ready for installation. n The cartridge valve is mounted and set.
Screw on basic panel loosely. Align basic panel horizontally and tighten screws.
Handling
Page 10
3.2.3 Mounting the flush plate
Requirements:
n The cartridge valve is mounted and set. n The basic panel has been mounted.
Determine the length of the actuating rod. The tip of the rod must lie 17 mm behind the front edge of the basic panel.
Shorten the actuating rod with a saw. Turn the actuating rod into the cartridge and counter with the
threaded nut.
Place the flush plate onto the basic panel.
INFO! Figure shows model 8351.2 as an example.
Handling
Visign for More 104 equipment set 10 from 12
Page 11
3.3 Faults, faults and remedy
Error Cause Remedy
Urinal does not flush Shut-off valve closed Open shut-off valve
Cartridge valve dirty or damaged Clean cartridge valve, if necessary,
replace
Ä Chapter 3.4.2 „Cleaning
cartridge valve“ on page 11
Flush is too weak Shut-off valve is not open far
enough
Open shut-off valve
Cartridge valve dirty or damaged Clean cartridge valve, if necessary,
replace
Ä Chapter 3.4.2 „Cleaning
cartridge valve“ on page 11
Urinal flush runs through Cartridge valve dirty or damaged Clean cartridge valve, if necessary,
replace
Ä Chapter 3.4.2 „Cleaning
cartridge valve“ on page 11
3.4 Care and maintenance
3.4.1 Maintenance tips
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the flush plate. Under no circumstances should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.
3.4.2 Cleaning cartridge valve
The cartridge valve may be cleaned, if necessary. Proceed as follows:
Remove the flush plate from the basic panel.
INFO! Figure shows model 8351.2 as an example.
Handling
Visign for More 104 equipment set 11 from 12
Page 12
Close shut-off.
Unscrew cartridge valve.
Rinse cartridge valve under running water. Remove coarse dirt with a soft brush.
Re-mount cartridge valve and flush plate in acc. with
Ä Chapter
3.2.1 „Insert cartridge valve“ on page 8 Ä Chapter 3.2.3 „Mounting the flush plate“ on page 10
.
3.5
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Handling
Visign for More 104 equipment set 12 from 12