Prevista Dry Plus washbasin module, bar‐
rier-free
Instructions for Use
for WB with single-hole fitting
ModelYear built:
8545.31from 03/2019
en_INT
Page 2
Prevista Dry Plus washbasin module, barrier-free2 from 11
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
Intended use6
Areas of use6
Product description6
Overview6
Compatible components6
3Handling7
3.1
3.1.1
3.1.2
3.2
3.2.1
3.2.2
3.3
Assembly information7
Mounting conditions7
Installation dimensions7
Assembly7
Mounting module7
Set and clad the module10
Disposal11
Prevista Dry Plus washbasin module, barrier-free3 from 11
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal.
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Drywall builder
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
Prevista Dry Plus washbasin module, barrier-free4 from 11
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e.g. EN) and/or in Germany
(e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand‐
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Prevista Dry Plus washbasin module, barrier-free5 from 11
Page 6
2Product information
.
.
2.1Intended use
2.1.1Areas of use
The Prevista Dry Plus washbasin module is designed for mounting in a
Prevista Dry Plus pre-wall construction.
2.2Product description
2.2.1Overview
Product information
Fig. 1: Components and scope of delivery
1Washbasin module
2Wall bracket for concealed odour trap
3Screws for fixing in support profile
4Assembly accessories concealed odour trap
5slot nuts
6Assembly accessories wall plates
7threaded rods for fixing sanitary objects
2.2.2Compatible components
Prevista Dry Plus washbasin module, barrier-free6 from 11
The washbasin module is compatible with all common washbasin
ceramics, even with larger projection (barrier-free).
Page 7
3Handling
NBY
3.1Assembly information
3.1.1Mounting conditions
Suitable walls
n Prevista Dry Plus pre-wall constructions
The washbasin module may only be mounted on even wall surfaces.
Construction height
With the construction height, the marked height of the upper edge of
the finished floor must be observed.
Handling
3.1.2Installation dimensions
3.2Assembly
3.2.1Mounting module
Mounting in Prevista Dry Plus
Prevista Dry Plus washbasin module, barrier-free7 from 11
Page 8
Handling
The two vertical rails, which surround the module, must be
open towards the module and have an inner distance of
420 mm.
Secure the module onto the open mounting rail with the slot nuts
supplied.
Insert the slot nut into the opening of the module.
Push the slot nut in until it engages.
Set the height of the rail.
Prevista Dry Plus washbasin module, barrier-free8 from 11
Page 9
Fasten the slot nut.
25 Nm
9
9
İ
Bend the sides of the metal bars of the rails.
Handling
Bend the sides of the metal bars of the fitting holder.
Set the height of the module according to the ceramic manufactur‐
er's instructions.
Prevista Dry Plus washbasin module, barrier-free9 from 11
Page 10
3.2.2Set and clad the module
.
W
J
F
H
B
.
ς
W
J
F
H
B
.
Handling
Mount an odour trap.
Turn in the threaded rods by hand.
Tighten the nuts of the threaded rods with a fork spanner (size 17).
Place the protective caps on the threaded rods.
Make the water connections.
Cut the gypsum cardboard cladding panel to size.
Prevista Dry Plus washbasin module, barrier-free10 from 11
Page 11
3.3Disposal
Handling
Clad the module with suitable gypsum cardboard cladding panels.
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Prevista Dry Plus washbasin module, barrier-free11 from 11