Viega Multiplex Trio Visign MT3 Instructions For Use Manual

Page 1
Multiplex Trio equipment set Visign MT3
Instructions for Use
for drain/overflow functional unit Model Year built:
6161.13 from 06/2015
en_INT
Page 2
Multiplex Trio equipment set Visign MT3 2 from 10
Page 3

Table of contents

Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
2.2.2
Intended use 6 Areas of use 6 Product description 6 Overview 6 Equipment versions 6
3 Handling 7
3.1
3.1.1
3.1.2
3.2
3.2.1
3.2.2
3.3
3.4
3.5
Assembly information 7 Mounting conditions 7 Required tools and materials 7 Assembly 7 Mounting equipment set 7 Demounting rotatable rosette 8 Control 8 Maintenance 10 Disposal 10
Multiplex Trio equipment set Visign MT3 3 from 10
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex Trio equipment set Visign MT3 4 from 10
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Multiplex Trio equipment set Visign MT3 5 from 10
Page 6

2 Product information

2
31

2.1 Intended use

2.1.1 Areas of use

The equipment set is exclusively suitable for use with a Multiplex Trio inlet / drain / overflow for bathtubs with a 52 mm drain hole.
The model described here cannot be combined with Multi­plex products. Separate equipment sets with other model numbers are available for the Multiplex drains / and over­flows.
Product information

2.2 Product description

2.2.1 Overview

The following components are included in the scope of delivery of the equipment set:
Fig. 1: Component overview
1 - flange cover 2 - rotatable rosette 3 - valve cone

2.2.2 Equipment versions

The model is available in the following versions:
Version
chrome-plated 725 792
designer white 725 822
Multiplex Trio equipment set Visign MT3 6 from 10
Article number
Page 7

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

The following requirements exist for the mounting of the equipment set:
n The bathtub is fully installed. n A Multiplex Trio drain and overflow is installed. n All other tasks on the building site have been completed.

3.1.2 Required tools and materials

Tool
Handling
The following tools are required for mounting:
n slotted screw driver
Material
No additional material is required for the complete mounting of the product.
3.2
Assembly

3.2.1 Mounting equipment set

To avoid damage to the rosette and valve cone, only mount the equip­ment set after finishing all other work on the building site. Proceed as follows:
Place the flange cover onto the inlet flange with the straight side facing downwards and affix.
Align and fit rotatable rosette. Fit valve cone.
Turn rotatable rosette to check function and alignment. The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve cone using the adjusting screw (see next step).
Multiplex Trio equipment set Visign MT3 7 from 10
Page 8
Set the valve cone with the help of the adjusting screw and counter with union nut.

3.2.2 Demounting rotatable rosette

If the rotatable rosette on the overflow is to be removed, proceed as fol­lows to prevent damaging the rosette and the flange cover:
Handling
Remove the rotatable rosette in the axial direction.
Remove the flange cover at the marked points. Remove flange cover.
3.3
Multiplex Trio equipment set Visign MT3 8 from 10
Control
The drain / overflow are controlled via rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Page 9
Turn rotatable rosette to the left.
The drain closes itself.
ð
Turn rotatable rosette to the right.
The drain opens itself.
ð
Handling
Setting the water inlet direction
There is a regulator for the water jet on the underside of the rotatable rosette. Proceed as follows to adjust the water jet:
Push the flow control backwards or forwards with your finger. The water flows closer or further away from the side of the bathtub depending on the direction set.
Multiplex Trio equipment set Visign MT3 9 from 10
Page 10

3.4 Maintenance

Handling
NOTICE! Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
– scouring agent – abrasive sponges – lime, plaster or cement dissolver – solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.

3.5 Disposal

Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.