for water inlet through the drain unit
ModelYear built:
6145.5from 06/2015
en_INT
Page 2
Multiplex Trio F drain/overflow functional unit2 from 25
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use6
Areas of use6
Product description6
Overview6
Technical data8
Accessories8
3Handling9
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.3
3.4
3.4.1
3.4.2
3.4.3
3.5
Assembly information9
Mounting conditions9
Installation dimensions11
Required tools and materials11
Assembly12
Connect and mount pipe interrupter12
Mounting overflow14
Mounting the drain15
Connecting overflow and drain16
Connecting the wastewater system17
Connecting the inlet18
Mounting equipment set19
Leakage test20
Control20
Simple maintenance and cleaning pipe21
Maintenance21
Cleaning pipe interrupter22
Cleaning the drain23
Disposal25
Multiplex Trio F drain/overflow functional unit3 from 25
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document, further information can be
found at www.viega.com/legal-notices.
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
n Consumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex Trio F drain/overflow functional unit4 from 25
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Multiplex Trio F drain/overflow functional unit5 from 25
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
NOTICE!
Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following
liquids:
– Liquids with a pH-value higher than 4
– typical household wastewater with temperatures up to
95 °C
Product information
2.2
Product description
2.2.1Overview
The Multiplex Trio drain/overflow is a combined inlet, drain and overflow
with odour trap for bathtubs with a 52 mm drain hole. The inlet flows
particularly quietly through the overflow opening.
The drain/overflow is suitable for bathtubs with a middle connection.
Detailed information regarding all bathtub models and the corre-
sponding Viega drains / overflows can be found in the catalogue or on
the Internet.
The following components are included in the scope of delivery of the
Multiplex Trio F drain / overflow:
Multiplex Trio F drain/overflow functional unit6 from 25
Page 7
1
2
3
5
4
6
8
7
10 91112121311101415
17 18 1920 21222324
16
Product information
Fig. 1: Component overview
1 - mounting aid
2 - cover plate
3 - fixing screws
4 - inlet element
5 - screw-in valve (1 x 22.5 mm, 1 x 30 mm)
6 - seal
7 - profile seal
8 - connection elbow
9 - drain elbow
10 - union nut
11 - sliding ring
12 - seal
13 - drain unit with odour trap
14 - overflow pipe
15 - Bowden cable
16 - sleeve
17 - overflow unit
18 - profile seal
19 - O-ring
20 - fixing flange
21 - rotatable rosette
22 - pipe interrupter casing
23 - top of the pipe interrupter
24 - pipe interrupter rosette
Multiplex Trio F drain/overflow functional unit7 from 25
Page 8
2.2.2Technical data
Product information
Drainage capacity (at an accumulation height of 300 mm)
Overflow capacity (at an accumulation height of 60 mm)
Inlet capacity (at 0.25 MPa
(2.5 bar))
Diameter of bathtub drain hole52 mm
DN (nominal diameter) drain
socket
Length of Bowden cable725 mm
Length130–370 mm
Height180–480 mm
Dimensions and installation depth
0.85 l/s
0.63 l/s
20 l/min
40 / 50 mm
Ä Chapter 3.1.2 „Installation
dimensions“ on page 11
Water seal level50 mm
2.3Accessories
Optional accessories
The accessories shown here are not included in the scope
of delivery. If required, it must be purchased separately.
Multiplex extension set
It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is
available for such cases.
Multiplex Trio F drain/overflow functional unit8 from 25
Page 9
3Handling
3.1Assembly information
3.1.1Mounting conditions
The following requirements exist for the mounting of the drain / overflow:
n The bathtub is installed.
n The drainage line is installed all the way to the bathtub.
n The underside of the bathtub is accessible.
Pipe interrupter
Backflow situation: If a negative pressure situation should occur when
the bathtub is filled, there is a possibility that bath water may flow back
into the drinking water system.
Handling
To ensure that no bath water flows back into the drinking water system,
a pipe interrupter must be installed in the pipeline between the shut-off
fitting and the bathtub inlet.
The following schematic diagram shows what this should look like:
Multiplex Trio F drain/overflow functional unit9 from 25
Page 10
0
Handling
Fig. 2: Mounting scheme with pipe interrupter
It is important that the pipe interrupter is mounted vertically, in the
direction of flow and at least 150 mm above the top edge of the
bathtub.
Observe the local standards and regulations.
Multiplex Trio F drain/overflow functional unit10 from 25
Page 11
3.1.2Installation dimensions
Ø75
Ø70
Ø40
Ø50
80
60
L
125
75
110
H
Handling
Fig. 3: Dimensional drawing
The following values are valid for L (length) and H (height):
L = 130–370
H = 180–370
3.1.3Required tools and materials
Tool
The following tools are required for mounting:
Material
n fine-toothed saw
n mounting aid (included in the scope of delivery)
n Allen key (SW 3)
No additional material is required for the complete mounting of the
product.
Multiplex Trio F drain/overflow functional unit11 from 25
Page 12
3.2Assembly
3.2.1Connect and mount pipe interrupter
The pipe interrupter must be mounted according to the plan in
Ä Chapter 3.1.1 „Mounting conditions“ on page 9
installation of the bathtub before the work on the walls is finished. Proceed as follows:
n The direction of flow runs from diagonal to vertical downwards.
n The line does not continue to rise downstream from the pipe inter-
rupter.
n All of the accessories (pipes, connecting pieces ¾ inch) required for
complete assembly are included.
n During assembly, the protective plug is to be found on the top stem.
Handling
for the subsequent
INFO! We show the mounting here with the Viega plug connection. Mounting can also be carried out with other connecting
materials. If necessary, observe the manufacturer's instructions.
Push the union nut and clamping ring onto the pipe.
Push Viega plug-in seat as far as it will go into the pipe.
Euro cone connections are not compatible.
Push the free end of the plug-in seat into the connection of the pipe
interrupter.
Using the union nut, screw the pipe tightly onto the pipe interrupter.
Repeat the procedure with the second pipe.
INFO! We show the mounting here with the Viega plug connection. Mounting can also be carried out with other connecting
materials. If necessary, observe the manufacturer's instructions.
Seal adapter elbow and twist into the connection of the mixer tap.
Push the union nut and clamping ring onto the pipe.
Screw in the pipe tight with the union nut onto the adapter elbow.
Lay the free pipe end up to the connection place of the bathtub
drain/overflow.
Multiplex Trio F drain/overflow functional unit12 from 25
Page 13
90°
Handling
Align pipe interrupter.
Mark drill holes.
Drill holes.
Screw on pipe interrupter with two crossed slot screws (size 4.5 or
5).
Encase the pipe interrupter and connection line in mortar.
Tile the wall.
Remove protective plug.
Multiplex Trio F drain/overflow functional unit13 from 25
Page 14
Shorten shaft top with a fine-toothed saw.
The shaft top must be flush with the height of the tiles.
Clean shaft top when contaminated.
Insert the rosette into the shaft top.
Handling
3.2.2Mounting overflow
Proceed as follows to the mounting of the overflow:
Push the rubber sleeve onto the pipe of the overflow unit.
The lower edge must be flush with the edge of the overflow pipe.
Multiplex Trio F drain/overflow functional unit14 from 25
Page 15
Handling
Fit profile seal in the overflow unit.
Place the O-ring in the annular gap of the fixing flange.
Hold the overflow unit on the overflow opening of the bathtub from
the outside.
3.2.3Mounting the drain
Screw the fixing flange into the overflow unit by hand.
Pliers or other tools may damage the fixing flange. Only turn the
fixing flange by hand.
Proceed as follows to mount the drain:
Place the profile seal in the recess of the drain unit.
Mount the drain unit with profile seal on the drain opening of the
bathtub from below.
Multiplex Trio F drain/overflow functional unit15 from 25
Page 16
B
A
Handling
Select suitable valve top:
Use the B = 22.5 mm high flat valve top for steel tubs with wall
thickness A = 2–11 mm.
Use the B = 30 mm high valve top for plastic tubs with wall thick-
ness A = 11–16 mm.
Apply lubricant to the inside of the seal and place onto the under-
side of the valve top.
Install the valve top into the drain unit and screw together with the
mounting aid.
The mounting aid must be placed on the screw recesses with the
holes on the underside.
3.2.4Connecting overflow and drain
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Requirements:
n The overflow is mounted in the overflow opening.
n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.
Multiplex Trio F drain/overflow functional unit16 from 25
Page 17
Ø50
Ø40
Handling
Hold the pipe of the overflow unit parallel to the overflow pipe and
mark the positions where the drain and the overflow should be connected.
Maintain an insertion depth of at least 15 mm!
Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve.
Maintain an insertion depth of at least 15 mm!
Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow.
Screw the union nut on the drain unit.
3.2.5Connecting the wastewater system
Proceed as follows to connect the drain/overflow to the wastewater
system:
Requirements:
n The overflow and drain units are installed on the bathtub.
n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain
elbow.
Multiplex Trio F drain/overflow functional unit17 from 25
Page 18
Push union nut, sliding ring and seal onto the drain elbow.
Ø50
Ø40
Screw the union nut on the drain unit.
Maintain an insertion depth of at least 15 mm!
Turn the drain at the joint until the required position has been
reached.
Push wastewater pipe in the drain elbow.
Handling
3.2.6Connecting the inlet
Proceed as follows to connect the water inlet to the drain unit:
Requirements:
n A connection set (e. g. the pipe interrupter set) is available.
n A pipe interrupter is installed in the supply pipeline.
n Overflow and drain are mounted.
n Overflow and drain are connected.
n The connection to the wastewater system has been made.
Remove the union nut of the connection elbow from the drain unit
and remove connection elbow.
Multiplex Trio F drain/overflow functional unit18 from 25
Page 19
Handling
INFO! We show the mounting here with the Viega plug connection. Mounting can also be carried out with other connecting
materials. If necessary, observe the manufacturer's instructions.
Push union nut and clamping ring (parts of the connection set) onto
the water-carrying pipe.
Push the narrow end of the screw fitting (part of the connection set)
into the pipe as far as it will go.
Push the free end of the screw fitting into the connection elbow.
Screw in the pipe tight with the union nut onto the connection
elbow.
Place the connection elbow onto the connection of the drain unit
and tighten the union nut by hand.
3.2.7Mounting equipment set
To avoid damage to the rosette and valve cone, only mount the equipment set after finishing all other work on the building site. Proceed as
follows:
Fit the inlet element into the drain unit.
The shaft on the side of the inlet element must be inserted into the
recess in the drain unit.
Multiplex Trio F drain/overflow functional unit19 from 25
Page 20
Turn the external ring of the inlet element in such a way that the
screw heads of the screw-in valve is reachable.
Fit Allen screws and tighten only gently by hand.
Screw cover plate onto the drain by hand.
Align and push in overflow rosette.
Handling
3.2.8Leakage test
3.3
Control
The leakage test is only carried out as a visual inspection.
Check drain/overflow fitting for visible leaks.
The drain / overflow are controlled via the rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Multiplex Trio F drain/overflow functional unit20 from 25
Page 21
Turn rotatable rosette to the left.
The drain closes itself.
ð
Turn rotatable rosette to the right.
The drain opens itself.
ð
Handling
3.4Simple maintenance and cleaning pipe
3.4.1Maintenance
NOTICE!
Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated
surfaces and therefore may not be used:
– scouring agent
– abrasive sponges
– lime, plaster or cement dissolver
– solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the rotatable rosette and valve cone. Under
no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be
removed using typical household cleaner. It should be noted that the
cleaning agent should be rinsed off after the prescribed soaking time.
There should be no residue on the components.
Multiplex Trio F drain/overflow functional unit21 from 25
Page 22
3.4.2Cleaning pipe interrupter
The pipe interrupter must be cleaned regularly as limescale on the
membrane can be detrimental to its functionality. The cleaning interval
depends from the local water and should be decided during mounting.
Proceed as follows to clean or replace the insert with the membrane:
Handling
In the case of extensive contamination, the insert has to be
replaced to ensure the functionality of the pipe interrupter.
Remove rosette.
Pull the insert out of the casing using multigrip pliers.
If there is only a little limescale and contamination, rinse the insert
carefully.
Multiplex Trio F drain/overflow functional unit22 from 25
Page 23
Handling
If excessive limescale and contamination is found, use new insert
(model 6161.82)
Using multigrip pliers, insert the insert into the casing of the pipe
interrupter vertically from the front.
3.4.3Cleaning the drain
Insert the rosette into the shaft top.
The drain should be cleaned at regular intervals. The cleaning interval
depends on the use of the tub installation.
Proceed as follows to clean the drain:
Multiplex Trio F drain/overflow functional unit23 from 25
Page 24
Unscrew cover plate by hand.
Loosen the Allen screws of the inlet element with the Allen key
(size 3).
Remove inlet element.
Handling
Clean inlet element by holding it under running water.
Do not use any sharp or pointed objects when cleaning as this could
damage the material.
Loosen the Allen screw of the valve cone with an Allen key (size 3).
Multiplex Trio F drain/overflow functional unit24 from 25
Page 25
Handling
Close the valve cone with the rotatable rosette and retain this position.
Remove valve cone.
If the seal of the valve cone is damaged or has excessive limescale,
remove the seal.
Place a new seal in the recess in the valve cone.
Only use original replacement seals from Viega (model 6162-268),
which are intended for the valve cone.
If necessary, clean drain casing with running water and a mild
cleaning agent.
INFO! Do not use any abrasive cleaner or pipe cleaner as
these can damage the plastic of the drain casing.
To install, follow the same steps in reverse order.
3.5Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Multiplex Trio F drain/overflow functional unit25 from 25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.