Multiplex Trio F drain/overflow functional unit
Instructions for Use
for water inlet through the drain unit Model Year built:
6145.5 from 06/2015
en_INT
Page 2
Multiplex Trio F drain/overflow functional unit 2 from 25
Page 3
1 About these instructions for use 4
Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use 6 Areas of use 6 Product description 6 Overview 6 Technical data 8 Accessories 8
3 Handling 9
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.3
3.4
3.4.1
3.4.2
3.4.3
3.5
Assembly information 9 Mounting conditions 9 Installation dimensions 11 Required tools and materials 11 Assembly 12 Connect and mount pipe interrupter 12 Mounting overflow 14 Mounting the drain 15 Connecting overflow and drain 16 Connecting the wastewater system 17 Connecting the inlet 18 Mounting equipment set 19 Leakage test 20 Control 20 Simple maintenance and cleaning pipe 21 Maintenance 21 Cleaning pipe interrupter 22 Cleaning the drain 23 Disposal 25
Multiplex Trio F drain/overflow functional unit 3 from 25
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at www.viega.com/legal-notices.

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex Trio F drain/overflow functional unit 4 from 25
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Multiplex Trio F drain/overflow functional unit 5 from 25
Page 6

2 Product information

2.1 Intended use

2.1.1 Areas of use

NOTICE! Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following liquids:
– Liquids with a pH-value higher than 4 – typical household wastewater with temperatures up to
95 °C
Product information
2.2
Product description

2.2.1 Overview

The Multiplex Trio drain/overflow is a combined inlet, drain and overflow with odour trap for bathtubs with a 52 mm drain hole. The inlet flows particularly quietly through the overflow opening.
The drain/overflow is suitable for bathtubs with a middle connection. Detailed information regarding all bathtub models and the corre-
sponding Viega drains / overflows can be found in the catalogue or on the Internet.
The following components are included in the scope of delivery of the Multiplex Trio F drain / overflow:
Multiplex Trio F drain/overflow functional unit 6 from 25
Page 7
1
2
3
5
4
6
8
7
10 9111212 1311101415
17 18 19 20 21 22 23 24
16
Product information
Fig. 1: Component overview
1 - mounting aid 2 - cover plate 3 - fixing screws 4 - inlet element 5 - screw-in valve (1 x 22.5 mm, 1 x 30 mm) 6 - seal 7 - profile seal 8 - connection elbow 9 - drain elbow 10 - union nut 11 - sliding ring 12 - seal 13 - drain unit with odour trap 14 - overflow pipe 15 - Bowden cable 16 - sleeve 17 - overflow unit 18 - profile seal 19 - O-ring 20 - fixing flange 21 - rotatable rosette 22 - pipe interrupter casing 23 - top of the pipe interrupter 24 - pipe interrupter rosette
Multiplex Trio F drain/overflow functional unit 7 from 25
Page 8

2.2.2 Technical data

Product information
Drainage capacity (at an accumu­lation height of 300 mm)
Overflow capacity (at an accumu­lation height of 60 mm)
Inlet capacity (at 0.25 MPa (2.5 bar))
Diameter of bathtub drain hole 52 mm
DN (nominal diameter) drain socket
Length of Bowden cable 725 mm
Length 130–370 mm
Height 180–480 mm
Dimensions and installation depth
0.85 l/s
0.63 l/s
20 l/min
40 / 50 mm
Ä Chapter 3.1.2 „Installation dimensions“ on page 11
Water seal level 50 mm

2.3 Accessories

Optional accessories
The accessories shown here are not included in the scope of delivery. If required, it must be purchased separately.
Multiplex extension set It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is available for such cases.
Multiplex Trio F drain/overflow functional unit 8 from 25
Page 9

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

The following requirements exist for the mounting of the drain / over­flow:
n The bathtub is installed. n The drainage line is installed all the way to the bathtub. n The underside of the bathtub is accessible.
Pipe interrupter
Backflow situation: If a negative pressure situation should occur when the bathtub is filled, there is a possibility that bath water may flow back into the drinking water system.
Handling
To ensure that no bath water flows back into the drinking water system, a pipe interrupter must be installed in the pipeline between the shut-off fitting and the bathtub inlet.
The following schematic diagram shows what this should look like:
Multiplex Trio F drain/overflow functional unit 9 from 25
Page 10
0
Handling
Fig. 2: Mounting scheme with pipe interrupter
It is important that the pipe interrupter is mounted vertically, in the direction of flow and at least 150 mm above the top edge of the bathtub.
Observe the local standards and regulations.
Multiplex Trio F drain/overflow functional unit 10 from 25
Page 11

3.1.2 Installation dimensions

Ø75
Ø70
Ø40
Ø50
80
60
L
125
75
110
H
Handling
Fig. 3: Dimensional drawing
The following values are valid for L (length) and H (height): L = 130–370
H = 180–370

3.1.3 Required tools and materials

Tool
The following tools are required for mounting:
Material
n fine-toothed saw n mounting aid (included in the scope of delivery) n Allen key (SW 3)
No additional material is required for the complete mounting of the product.
Multiplex Trio F drain/overflow functional unit 11 from 25
Page 12

3.2 Assembly

3.2.1 Connect and mount pipe interrupter

The pipe interrupter must be mounted according to the plan in
Ä Chapter 3.1.1 „Mounting conditions“ on page 9
installation of the bathtub before the work on the walls is finished. Pro­ceed as follows:
n The direction of flow runs from diagonal to vertical downwards. n The line does not continue to rise downstream from the pipe inter-
rupter.
n All of the accessories (pipes, connecting pieces ¾ inch) required for
complete assembly are included.
n During assembly, the protective plug is to be found on the top stem.
Handling
for the subsequent
INFO! We show the mounting here with the Viega plug connec­tion. Mounting can also be carried out with other connecting materials. If necessary, observe the manufacturer's instructions.
Push the union nut and clamping ring onto the pipe. Push Viega plug-in seat as far as it will go into the pipe. Euro cone connections are not compatible. Push the free end of the plug-in seat into the connection of the pipe
interrupter. Using the union nut, screw the pipe tightly onto the pipe interrupter. Repeat the procedure with the second pipe.
INFO! We show the mounting here with the Viega plug connec­tion. Mounting can also be carried out with other connecting materials. If necessary, observe the manufacturer's instructions.
Seal adapter elbow and twist into the connection of the mixer tap. Push the union nut and clamping ring onto the pipe. Screw in the pipe tight with the union nut onto the adapter elbow.
Lay the free pipe end up to the connection place of the bathtub drain/overflow.
Multiplex Trio F drain/overflow functional unit 12 from 25
Page 13
90°
Handling
Align pipe interrupter. Mark drill holes. Drill holes.
Screw on pipe interrupter with two crossed slot screws (size 4.5 or
5). Encase the pipe interrupter and connection line in mortar.
Tile the wall.
Remove protective plug.
Multiplex Trio F drain/overflow functional unit 13 from 25
Page 14
Shorten shaft top with a fine-toothed saw. The shaft top must be flush with the height of the tiles. Clean shaft top when contaminated.
Insert the rosette into the shaft top.
Handling

3.2.2 Mounting overflow

Proceed as follows to the mounting of the overflow:
Push the rubber sleeve onto the pipe of the overflow unit. The lower edge must be flush with the edge of the overflow pipe.
Multiplex Trio F drain/overflow functional unit 14 from 25
Page 15
Handling
Fit profile seal in the overflow unit.
Place the O-ring in the annular gap of the fixing flange. Hold the overflow unit on the overflow opening of the bathtub from
the outside.

3.2.3 Mounting the drain

Screw the fixing flange into the overflow unit by hand. Pliers or other tools may damage the fixing flange. Only turn the
fixing flange by hand.
Proceed as follows to mount the drain:
Place the profile seal in the recess of the drain unit. Mount the drain unit with profile seal on the drain opening of the
bathtub from below.
Multiplex Trio F drain/overflow functional unit 15 from 25
Page 16
B
A
Handling
Select suitable valve top: Use the B = 22.5 mm high flat valve top for steel tubs with wall
thickness A = 2–11 mm. Use the B = 30 mm high valve top for plastic tubs with wall thick-
ness A = 11–16 mm. Apply lubricant to the inside of the seal and place onto the under-
side of the valve top.
Install the valve top into the drain unit and screw together with the mounting aid.
The mounting aid must be placed on the screw recesses with the holes on the underside.

3.2.4 Connecting overflow and drain

After the overflow and the drain have been mounted, you must connect them both using the overflow pipe. Proceed as follows:
Requirements:
n The overflow is mounted in the overflow opening. n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far enough into each other become leaky. For this reason, maintain a minimum insertion depth of 15 mm for every connection.
Multiplex Trio F drain/overflow functional unit 16 from 25
Page 17
Ø50
Ø40
Handling
Hold the pipe of the overflow unit parallel to the overflow pipe and mark the positions where the drain and the overflow should be con­nected.
Maintain an insertion depth of at least 15 mm! Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve. Maintain an insertion depth of at least 15 mm! Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow. Screw the union nut on the drain unit.

3.2.5 Connecting the wastewater system

Proceed as follows to connect the drain/overflow to the wastewater system:
Requirements:
n The overflow and drain units are installed on the bathtub. n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain elbow.
Multiplex Trio F drain/overflow functional unit 17 from 25
Page 18
Push union nut, sliding ring and seal onto the drain elbow.
Ø50
Ø40
Screw the union nut on the drain unit. Maintain an insertion depth of at least 15 mm!
Turn the drain at the joint until the required position has been reached.
Push wastewater pipe in the drain elbow.
Handling

3.2.6 Connecting the inlet

Proceed as follows to connect the water inlet to the drain unit:
Requirements:
n A connection set (e. g. the pipe interrupter set) is available. n A pipe interrupter is installed in the supply pipeline. n Overflow and drain are mounted. n Overflow and drain are connected. n The connection to the wastewater system has been made.
Remove the union nut of the connection elbow from the drain unit and remove connection elbow.
Multiplex Trio F drain/overflow functional unit 18 from 25
Page 19
Handling
INFO! We show the mounting here with the Viega plug connec­tion. Mounting can also be carried out with other connecting materials. If necessary, observe the manufacturer's instructions.
Push union nut and clamping ring (parts of the connection set) onto the water-carrying pipe.
Push the narrow end of the screw fitting (part of the connection set) into the pipe as far as it will go.
Push the free end of the screw fitting into the connection elbow. Screw in the pipe tight with the union nut onto the connection
elbow.
Place the connection elbow onto the connection of the drain unit and tighten the union nut by hand.

3.2.7 Mounting equipment set

To avoid damage to the rosette and valve cone, only mount the equip­ment set after finishing all other work on the building site. Proceed as follows:
Fit the inlet element into the drain unit. The shaft on the side of the inlet element must be inserted into the
recess in the drain unit.
Multiplex Trio F drain/overflow functional unit 19 from 25
Page 20
Turn the external ring of the inlet element in such a way that the screw heads of the screw-in valve is reachable.
Fit Allen screws and tighten only gently by hand.
Screw cover plate onto the drain by hand. Align and push in overflow rosette.
Handling

3.2.8 Leakage test

3.3
Control
The leakage test is only carried out as a visual inspection.
Check drain/overflow fitting for visible leaks.
The drain / overflow are controlled via the rotatable rosette on the over­flow. Proceed as follows to open or close the drain:
Multiplex Trio F drain/overflow functional unit 20 from 25
Page 21
Turn rotatable rosette to the left.
The drain closes itself.
ð
Turn rotatable rosette to the right.
The drain opens itself.
ð
Handling

3.4 Simple maintenance and cleaning pipe

3.4.1 Maintenance

NOTICE! Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
– scouring agent – abrasive sponges – lime, plaster or cement dissolver – solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
Multiplex Trio F drain/overflow functional unit 21 from 25
Page 22

3.4.2 Cleaning pipe interrupter

The pipe interrupter must be cleaned regularly as limescale on the membrane can be detrimental to its functionality. The cleaning interval depends from the local water and should be decided during mounting.
Proceed as follows to clean or replace the insert with the membrane:
Handling
In the case of extensive contamination, the insert has to be replaced to ensure the functionality of the pipe interrupter.
Remove rosette.
Pull the insert out of the casing using multigrip pliers.
If there is only a little limescale and contamination, rinse the insert carefully.
Multiplex Trio F drain/overflow functional unit 22 from 25
Page 23
Handling
If excessive limescale and contamination is found, use new insert (model 6161.82)
Using multigrip pliers, insert the insert into the casing of the pipe interrupter vertically from the front.

3.4.3 Cleaning the drain

Insert the rosette into the shaft top.
The drain should be cleaned at regular intervals. The cleaning interval depends on the use of the tub installation.
Proceed as follows to clean the drain:
Multiplex Trio F drain/overflow functional unit 23 from 25
Page 24
Unscrew cover plate by hand.
Loosen the Allen screws of the inlet element with the Allen key (size 3).
Remove inlet element.
Handling
Clean inlet element by holding it under running water. Do not use any sharp or pointed objects when cleaning as this could
damage the material.
Loosen the Allen screw of the valve cone with an Allen key (size 3).
Multiplex Trio F drain/overflow functional unit 24 from 25
Page 25
Handling
Close the valve cone with the rotatable rosette and retain this posi­tion.
Remove valve cone.
If the seal of the valve cone is damaged or has excessive limescale, remove the seal.
Place a new seal in the recess in the valve cone. Only use original replacement seals from Viega (model 6162-268),
which are intended for the valve cone.
If necessary, clean drain casing with running water and a mild cleaning agent.
INFO! Do not use any abrasive cleaner or pipe cleaner as these can damage the plastic of the drain casing.
To install, follow the same steps in reverse order.

3.5 Disposal

Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Multiplex Trio F drain/overflow functional unit 25 from 25
Loading...