Viega 6163.2, Multiplex 6162.1 Instructions For Use Manual

Page 1
Multiplex drain/overflow functional unit
Instructions for Use
Model Year built:
6163.2 from 06/2015
en_INT
Page 2
Multiplex drain/overflow functional unit 2 from 17
Page 3

Table of contents

1 About these instructions for use 4
Table of contents
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use 6 Areas of use 6 Product description 6 Overview 6 Technical data 7 Accessories 8
3 Handling 10
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.3
3.4
3.5
Assembly information 10 Mounting conditions 10 Installation dimensions 10 Required tools and materials 10 Assembly 11 Mounting overflow 11 Mounting the drain 11 Connecting overflow and drain 12 Connecting the wastewater system 13 Mounting equipment set 14 Leakage test 15 Control 16 Maintenance 16 Disposal 17
Multiplex drain/overflow functional unit 3 from 17
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at www.viega.com/legal-notices.

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex drain/overflow functional unit 4 from 17
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Multiplex drain/overflow functional unit 5 from 17
Page 6

2 Product information

2.1 Intended use

2.1.1 Areas of use

NOTICE! Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following liquids:
– Liquids with a pH-value higher than 4 – typical household water with a maximum temperature of
95 °C
Product information
2.2
Product description

2.2.1 Overview

The Multiplex drain/overflow is a combined drain and overflow with odour trap for bathtubs with a 52 mm drain hole.
The drain / overflow is suitable for extra long bathtubs. Detailed information regarding all bathtub models and the corre-
sponding Viega drains / overflows can be found in the catalogue or on the Internet.
An equipment set with rotatable rosette and valve cone must be pur­chased separately.
The following components are included in the scope of delivery of the Multiplex drain / overflow:
Multiplex drain/overflow functional unit 6 from 17
Page 7
1 2
3
46 57811 765976510
13 14 15 16
12
Product information

2.2.2 Technical data

Fig. 1: Component overview
1 - fixing screw 2 - valve top 3 - double seal 4 - drain elbow 5 - union nut 6 - sliding ring 7 - seal 8 - odour trap 9 - pipe extension 10 - overflow pipe 11 - Bowden cable 12 - sleeve 13 - overflow unit 14 - profile seal 15 - O-ring 16 - fixing flange
Drainage capacity (at an accumu­lation height of 300 mm)
Overflow capacity (at an accumu­lation height of 60 mm)
0.87 l/s
0.63 l/s
Diameter of bathtub drain hole 52 mm
Multiplex drain/overflow functional unit 7 from 17
Page 8
Product information

2.3 Accessories

Required accessories
DN (nominal diameter) drain sup­port
Length of Bowden cable 1070 mm
Length 100–680 mm
Height 180–480 mm
Dimensions and installation depth
40 / 50 mm
Ä Chapter 3.1.2 „Installation dimensions“ on page 10
Water head seal 50 mm
The accessories shown here are not included in the scope of delivery. If required, it must be purchased separately.
Equipment sets As this product is a the functional unit (without rotatable rosette and
valve cone), you require an equipment set to enable complete mounting. Equipment sets contain a rotatable rosette for the overflow and a valve cone for the drain of the functional unit. You can find a choice of dif­ferent models in various designs in the catalogue.
Equipment set Multiplex Visign M3: Model 6154.0
Multiplex drain/overflow functional unit 8 from 17
Page 9
Optional accessories
Product information
Equipment set Multiplex Visign M5: Model 6162.01
Equipment set with water level increase The water level of the overflow can be increased by 5 cm with the
equipment set. The equipment set contains a rotatable rosette, a fixing flange, a valve cone, a fixing screw, a flange cover and a mounting aid for the drain of the functional unit.
Equipment set Multiplex Visign M9: Model 6171.0
Multiplex extension set It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is available for such cases.
Multiplex drain/overflow functional unit 9 from 17
Page 10

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

The following requirements exist for the mounting of the drain / over­flow:
n The bathtub is installed. n The drainage line is installed all the way to the bathtub. n The underside of the bathtub is accessible.

3.1.2 Installation dimensions

Handling
Fig. 2: Dimensional drawing
The following values are valid for L (length) and H (height): L = 100–680
H = 180–480

3.1.3 Required tools and materials

Tool
The following tools are required for mounting:
n socket wrench (SW 14) n fine-toothed saw n slotted screwdriver
Material
The following material must be purchased separately and must be avail­able during mounting:
n equipment set
Multiplex drain/overflow functional unit 10 from 17
Page 11

3.2 Assembly

3.2.1 Mounting overflow

Handling
Proceed as follows to the mounting of the overflow:
Fit profile seal in the overflow unit.
Push the rubber sleeve onto the overflow unit pipe until the lower edge is flush with the edge of the overflow pipe.
Place the O-ring in the annular gap of the fixing flange. Hold the overflow unit on the overflow opening of the bathtub from
the outside. Screw the fixing flange into the overflow unit by hand. Pliers or other tools may damage the fixing flange. Only turn the
fixing flange by hand.

3.2.2 Mounting the drain

Proceed as follows to mount the drain:
Multiplex drain/overflow functional unit 11 from 17
Page 12
Handling
Place the double seal onto the drain unit in such a way that the recess is positioned over the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below. Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
INFO! The cross-shaped structures of the drain units and the valve top must be positioned parallel on top of each other to ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using a socket wrench (SW 14).

3.2.3 Connecting overflow and drain

After the overflow and the drain have been mounted, you must connect them both using the overflow pipe. Proceed as follows:
Multiplex drain/overflow functional unit 12 from 17
Page 13
Handling
Requirements:
n The overflow is mounted in the overflow opening. n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far enough into each other become leaky. For this reason, maintain a minimum insertion depth of 15 mm for every connection.
Mount union nut, sliding ring and seal. Screw together overflow and extension pipes. Maintain an insertion depth of at least 15 mm! Hold the pipe of the overflow unit parallel to the overflow pipe and
mark the positions where the drain and the overflow should be con­nected.
Maintain an insertion depth of at least 15 mm! Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve. Maintain an insertion depth of at least 15 mm! Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow. Screw the union nut on the drain unit.

3.2.4 Connecting the wastewater system

Proceed as follows to connect the drain/overflow to the wastewater system:
Multiplex drain/overflow functional unit 13 from 17
Page 14
Requirements:
n The overflow and drain units are installed on the bathtub. n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain elbow.
Handling
Push union nut, sliding ring and seal onto the drain elbow. Screw the union nut on the drain unit.
Align the odour trap in such a way that the drain elbow can be con­nected to the wastewater pipe.
Turn the drain at the joints until the required position has been reached.
Push wastewater pipe in the drain elbow.

3.2.5 Mounting equipment set

The equipment set is not included in the scope of delivery and must be purchased separately.
Multiplex drain/overflow functional unit 14 from 17
Page 15
Handling
To avoid damage to the rosette and valve cone, only mount the equip­ment set after finishing all other work on the building site. Proceed as follows:
Align and fit rotatable rosette. Fit valve cone.

3.2.6 Leakage test

Turn rotatable rosette to check function and alignment. The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter with union nut.
The leakage test is only carried out as a visual inspection. Check the points marked in the following drawing with particular care:
Check drain fitting for visible leaks.
Multiplex drain/overflow functional unit 15 from 17
Page 16

3.3 Control

Handling
The drain / overflow are controlled via rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
The drain closes itself.
ð

3.4 Maintenance

Turn rotatable rosette to the right.
The drain opens itself.
ð
NOTICE! Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
– scouring agent – abrasive sponges – lime, plaster or cement dissolver – solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
Multiplex drain/overflow functional unit 16 from 17
Page 17

3.5 Disposal

Handling
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Multiplex drain/overflow functional unit 17 from 17
Loading...