Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use6
Areas of use6
Product description6
Overview6
Technical data7
Accessories8
3Handling10
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.3
3.4
3.5
Assembly information10
Mounting conditions10
Installation dimensions10
Required tools and materials10
Assembly11
Mounting overflow11
Mounting the drain11
Connecting overflow and drain12
Connecting the wastewater system13
Mounting equipment set14
Leakage test15
Control16
Maintenance16
Disposal17
Multiplex drain/overflow functional unit3 from 17
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document, further information can be
found at www.viega.com/legal-notices.
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
n Consumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex drain/overflow functional unit4 from 17
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Multiplex drain/overflow functional unit5 from 17
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
NOTICE!
Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following
liquids:
– Liquids with a pH-value higher than 4
– typical household water with a maximum temperature of
95 °C
Product information
2.2
Product description
2.2.1Overview
The Multiplex drain/overflow is a combined drain and overflow with
odour trap for bathtubs with a 52 mm drain hole.
The drain / overflow is suitable for extra long bathtubs.
Detailed information regarding all bathtub models and the corre-
sponding Viega drains / overflows can be found in the catalogue or on
the Internet.
An equipment set with rotatable rosette and valve cone must be purchased separately.
The following components are included in the scope of delivery of the
Multiplex drain / overflow:
Multiplex drain/overflow functional unit6 from 17
Page 7
1
2
3
4657811765976510
1314 15 16
12
Product information
2.2.2Technical data
Fig. 1: Component overview
1 - fixing screw
2 - valve top
3 - double seal
4 - drain elbow
5 - union nut
6 - sliding ring
7 - seal
8 - odour trap
9 - pipe extension
10 - overflow pipe
11 - Bowden cable
12 - sleeve
13 - overflow unit
14 - profile seal
15 - O-ring
16 - fixing flange
Drainage capacity (at an accumulation height of 300 mm)
Overflow capacity (at an accumulation height of 60 mm)
0.87 l/s
0.63 l/s
Diameter of bathtub drain hole52 mm
Multiplex drain/overflow functional unit7 from 17
Page 8
Product information
2.3Accessories
Required accessories
DN (nominal diameter) drain support
Length of Bowden cable1070 mm
Length100–680 mm
Height180–480 mm
Dimensions and installation depth
40 / 50 mm
Ä Chapter 3.1.2 „Installation
dimensions“ on page 10
Water head seal50 mm
The accessories shown here are not included in the scope
of delivery. If required, it must be purchased separately.
Equipment sets
As this product is a the functional unit (without rotatable rosette and
valve cone), you require an equipment set to enable complete mounting.
Equipment sets contain a rotatable rosette for the overflow and a valve
cone for the drain of the functional unit. You can find a choice of different models in various designs in the catalogue.
Equipment set Multiplex Visign M3: Model 6154.0
Multiplex drain/overflow functional unit8 from 17
Page 9
Optional accessories
Product information
Equipment set Multiplex Visign M5: Model 6162.01
Equipment set with water level increase
The water level of the overflow can be increased by 5 cm with the
equipment set. The equipment set contains a rotatable rosette, a fixing
flange, a valve cone, a fixing screw, a flange cover and a mounting aid
for the drain of the functional unit.
Equipment set Multiplex Visign M9: Model 6171.0
Multiplex extension set
It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is
available for such cases.
Multiplex drain/overflow functional unit9 from 17
Page 10
3Handling
3.1Assembly information
3.1.1Mounting conditions
The following requirements exist for the mounting of the drain / overflow:
n The bathtub is installed.
n The drainage line is installed all the way to the bathtub.
n The underside of the bathtub is accessible.
3.1.2Installation dimensions
Handling
Fig. 2: Dimensional drawing
The following values are valid for L (length) and H (height):
L = 100–680
H = 180–480
3.1.3Required tools and materials
Tool
The following tools are required for mounting:
n socket wrench (SW 14)
n fine-toothed saw
n slotted screwdriver
Material
The following material must be purchased separately and must be available during mounting:
n equipment set
Multiplex drain/overflow functional unit10 from 17
Page 11
3.2Assembly
3.2.1Mounting overflow
Handling
Proceed as follows to the mounting of the overflow:
Fit profile seal in the overflow unit.
Push the rubber sleeve onto the overflow unit pipe until the lower
edge is flush with the edge of the overflow pipe.
Place the O-ring in the annular gap of the fixing flange.
Hold the overflow unit on the overflow opening of the bathtub from
the outside.
Screw the fixing flange into the overflow unit by hand.
Pliers or other tools may damage the fixing flange. Only turn the
fixing flange by hand.
3.2.2Mounting the drain
Proceed as follows to mount the drain:
Multiplex drain/overflow functional unit11 from 17
Page 12
Handling
Place the double seal onto the drain unit in such a way that the
recess is positioned over the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below.
Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
INFO! The cross-shaped structures of the drain units and the
valve top must be positioned parallel on top of each other to
ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using a socket
wrench (SW 14).
3.2.3Connecting overflow and drain
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Multiplex drain/overflow functional unit12 from 17
Page 13
Handling
Requirements:
n The overflow is mounted in the overflow opening.
n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.
Mount union nut, sliding ring and seal.
Screw together overflow and extension pipes.
Maintain an insertion depth of at least 15 mm!
Hold the pipe of the overflow unit parallel to the overflow pipe and
mark the positions where the drain and the overflow should be connected.
Maintain an insertion depth of at least 15 mm!
Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve.
Maintain an insertion depth of at least 15 mm!
Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow.
Screw the union nut on the drain unit.
3.2.4Connecting the wastewater system
Proceed as follows to connect the drain/overflow to the wastewater
system:
Multiplex drain/overflow functional unit13 from 17
Page 14
Requirements:
n The overflow and drain units are installed on the bathtub.
n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain
elbow.
Handling
Push union nut, sliding ring and seal onto the drain elbow.
Screw the union nut on the drain unit.
Align the odour trap in such a way that the drain elbow can be connected to the wastewater pipe.
Turn the drain at the joints until the required position has been
reached.
Push wastewater pipe in the drain elbow.
3.2.5Mounting equipment set
The equipment set is not included in the scope of delivery
and must be purchased separately.
Multiplex drain/overflow functional unit14 from 17
Page 15
Handling
To avoid damage to the rosette and valve cone, only mount the equipment set after finishing all other work on the building site. Proceed as
follows:
Align and fit rotatable rosette.
Fit valve cone.
3.2.6Leakage test
Turn rotatable rosette to check function and alignment.
The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve
cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter
with union nut.
The leakage test is only carried out as a visual inspection.
Check the points marked in the following drawing with particular care:
Check drain fitting for visible leaks.
Multiplex drain/overflow functional unit15 from 17
Page 16
3.3Control
Handling
The drain / overflow are controlled via rotatable rosette on the overflow.
Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
The drain closes itself.
ð
3.4Maintenance
Turn rotatable rosette to the right.
The drain opens itself.
ð
NOTICE!
Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated
surfaces and therefore may not be used:
– scouring agent
– abrasive sponges
– lime, plaster or cement dissolver
– solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the rotatable rosette and valve cone. Under
no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be
removed using typical household cleaner. It should be noted that the
cleaning agent should be rinsed off after the prescribed soaking time.
There should be no residue on the components.
Multiplex drain/overflow functional unit16 from 17
Page 17
3.5Disposal
Handling
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Multiplex drain/overflow functional unit17 from 17