Viega M5 Instructions For Use Manual

Page 1
for drain/overflow functional unit Model Year built:
6162.01 from 06/2015
en_INT
Multiplex Equipment set M5
Instructions for Use
Page 2
Page 3
Table of contents
1 About these instructions for use 4
1.1
Target groups 4
1.2
Labelling of notes 4
1.3
About this translated version 5
2 Product information 6
2.1
Intended use 6
2.1.1
Areas of use 6
2.2
Product description 6
2.2.1
Overview 6
2.2.2
Equipment versions 7
3 Handling 8
3.1
Assembly information 8
3.1.1
Mounting conditions 8
3.1.2
Required tools and materials 8
3.2
Assembly 8
3.2.1
Replacing the fixing flange 8
3.2.2
Mounting equipment set 9
3.3
Control 10
3.4
Maintenance 11
3.5
Disposal 11
Table of contents
Page 4
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at www.viega.com/legal-notices.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Page 5
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Page 6
2 Product information
2.1 Intended use
2.1.1 Areas of use
The equipment set is exclusively suitable for use with a Multiplex drain / overflow for bathtubs with a 52 mm drain hole.
The model described here cannot be combined with Multi­plex Trio products. Separate equipment sets with other model numbers are available for the Multiplex Trio inlets / drains / and overflows.
2.2 Product description
2.2.1 Overview
The following components are included in the scope of delivery of the equipment set:
Product information
Page 7
234
5
1
Fig. 1: Component overview
1 - mounting aid 2 - rotatable rosette 3 - fixing flange 4 - valve cone 5 - O-ring
2.2.2 Equipment versions
The model is available in the following versions:
Version
Article number
chrome-plated 721 244
chrome matt / velour chrome 735 906
stainless steel colours / brushed 735 890
designer white 735 883
Product information
Page 8
3 Handling
3.1 Assembly information
3.1.1 Mounting conditions
There are two possible installation situations for the equipment set:
n The equipment set should be replaced in an existing installation. n In the case of a new installation, the equipment set is fitted onto a
functional unit.
In the first case, carry out all of the steps of the installation as described below.
In the second case, make sure that the fixing flange corresponds exactly with the model supplied. If the correct fixing flange is installed, you can dispose of the mounting aid, the O-ring and the fixing flange and start with the second mounting step (
Ä Chapter 3.2.2 „Mounting
equipment set“ on page 9
).
3.1.2 Required tools and materials
The following tools are required for mounting:
n mounting aid (included in the scope of delivery) n slotted screw driver
No additional material is required for the complete mounting of the product.
3.2
Assembly
3.2.1 Replacing the fixing flange
The mounting aid serves the purpose of securing the over­flow when the fixing flange is removed. For this reason, the mounting aid must be held in the hand for the entire replacement procedure.
If the equipment set is to be mounted on an older model of the Multiplex drain/overflow, the fixing flange for the rotatable rosette must be replaced first. Proceed as follows:
Tool
Material
Handling
Page 9
Requirements:
n An older Multiplex model is installed. n The rotatable rosette has been removed.
Push the mounting aid through the middle hole of the fixing flange. Screw the mounting aid in a clockwise direction into the overflow
unit.
Hold the overflow in place using the mounting aid. Unscrew the fixing flange in an anti-clockwise direction. Remove and dispose of fixing flange and O-ring.
Mount new O-Ring onto the new fixing flange. Push the new fixing flange over the mounting aid and fit in the over-
flow unit. Tighten the fixing flange in a clockwise direction. Unscrew the mounting aid in an anti-clockwise direction and
remove.
3.2.2 Mounting equipment set
To avoid damage to the rosette and valve cone, only mount the equip­ment set after finishing all other work on the building site. Proceed as follows:
Handling
Page 10
Align and fit rotatable rosette. Fit valve cone.
Turn rotatable rosette to check function and alignment. The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter with union nut.
3.3 Control
The drain / overflow are controlled via rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
ð
The drain closes itself.
Handling
Multiplex Equipment set M5 10 from 11
Page 11
Turn rotatable rosette to the right.
ð
The drain opens itself.
3.4 Maintenance
NOTICE! Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
– scouring agent – abrasive sponges – lime, plaster or cement dissolver – solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
3.5
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Handling
Multiplex Equipment set M5 11 from 11
Loading...