Grundfix backflow trap base unit (cleaning pipe)2 from 11
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.2
2.2.1
2.2.2
2.3
2.3.1
2.3.2
Standards and regulations6
Intended use6
Areas of use6
Place of installation and installation conditions6
Product description9
Overview9
Operating mode9
3Handling10
3.1
3.1.1
3.2
3.2.1
3.3
Assembly information10
Installation dimensions10
Assembly10
Mount base unit10
Disposal11
Grundfix backflow trap base unit (cleaning pipe)3 from 11
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
Grundfix backflow trap base unit (cleaning pipe)4 from 11
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Grundfix backflow trap base unit (cleaning pipe)5 from 11
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
Regulations from section: Place of installation and installation conditions
Scope / NoticeRegulations applicable in Ger-
viega.com/standards
Product information
.
many
2.2Intended use
2.2.1Areas of use
Correct place of installation of the
backflow trap
Regulations from section: Fields of application
Scope / NoticeRegulations applicable in Ger-
Grundfix Plus Control meets the
requirements as type 3 backflow
trap with double backflow protection
The base unit is suitable for use in drain pipelines made of HT or sewer
pipe DN 100, 125 or 150. When using other pipes such as e. g. clay
pipes or cast-iron pipes, the relevant adapters for HT and sewer pipes
must be used. The base unit is suitable for faecal matter free, typical
household wastewater up to a temperature of 95 °C with pH values ≥ 4
or ≤ 10.
EN 12056
many
EN 13564
Use in industrial areas or in pipelines, which transport aggressive liquids
is not permitted. This includes cleaning agents, which can damage sanitary equipment, drainage equipment and pipe materials.
2.2.2
Grundfix backflow trap base unit (cleaning pipe)6 from 11
Place of installation and installation conditions
If the base unit is being used solely as an inlet to a wastewater line
(cleaning pipe), it can be installed anywhere. In the event of a subsequent conversion to a backflow trap for black water (model 4987.419) or
grey water (model 4987.38), the following installation conditions must be
observed.
Page 7
1
5
4
2
3
Product information
Fig. 1: Wrong place of installation of the backflow trap
Grundfix backflow trap base unit (cleaning pipe)7 from 11
Page 8
1
5
4
2
3
Product information
Fig. 2: Correct place of installation of the backflow trap
1 - Street = Backflow level
2 - Area safe from backflow
3 - Connection upper floor
4 - Area at risk of backflow
5 - Protection against backflow through backflow trap
The connection of the upper floor (3) onto the underground pipe must
be made between the backflow trap and sewer within the building (5) –
only then is it possible to ensure that the wastewater system can function faultlessly. To ensure that drainage is permanently guaranteed,
backflow traps may not be employed as the central safeguard for a
building with drainage equipment installed above the backflow level (1) –
in the event of backflow, it would lead to flooding in the building due to
wastewater being unable to drain away (4).
See
Ä „Regulations from section: Place of installation and installation
conditions“ on page 6
Grundfix backflow trap base unit (cleaning pipe)8 from 11
Page 9
2.3Product description
2.3.1Overview
Product information
2.3.2Operating mode
Fig. 3: Grundfix base unit
The base unit can be used as an inlet point to a pipeline.
With conversion kit model 4987.38, the base unit can be retrofitted to a
backflow trap with two shutter valves for grey water.
With conversion kit model 4987.419, the base unit can be retrofitted to
the electrically controlled backflow trap Grundfix Plus Control for black
water.
Grundfix backflow trap base unit (cleaning pipe)9 from 11
Page 10
3Handling
3.1Assembly information
3.1.1Installation dimensions
Handling
3.2Assembly
3.2.1Mount base unit
Fig. 4: Installation dimensions
DH1H2H3L1L2L3
11026010065405215545
12526010575405215550
16029512595470245640
The installation in the drainage pipeline may only be carried out by construction or specialised sanitary companies observing the building regulations and following this instruction for use.
Grundfix backflow trap base unit (cleaning pipe)10 from 11
Page 11
Install the base unit horizontally into the base pipeline.
Observe flow direction!
At maximum, line up to the middle of the drainpipe.
Handling
3.3Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Grundfix backflow trap base unit (cleaning pipe)11 from 11