Viega Eco Plus 8162.5 Instructions For Use Manual

Page 1
Viega Eco Plus basic element
Instructions for Use
for fitting holders 8062.1, 8063.0, 8064, Urinal module 8119.3, 8126
Model Year built:
8162.5 from 01/2013
en_INT
Page 2
Viega Eco Plus basic element 2 from 11
Page 3
1 About these instructions for use 4
Table of contents
1.1
1.2
1.3
Target groups 4
Labelling of notes 4
About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
Intended use 6
Areas of use 6
Product description 6
Overview 6
3 Handling 7
3.1
3.1.1
3.1.2
3.2
3.2.1
3.3
Assembly information 7
Installation dimensions 7
Required tools 7
Assembly 8
Mounting base element 8
Disposal 11
Viega Eco Plus basic element 3 from 11
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at viega.com/legal.

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Drywall builder
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Viega Eco Plus basic element 4 from 11
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand‐ ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Viega Eco Plus basic element 5 from 11
Page 6

2 Product information

2
1
3

2.1 Intended use

2.1.1 Areas of use

The Viega Eco Plus base element is suitable for:
n Fitting holders model 8062.1 and model 8063.0 n Urinal module model 8119.3 and model 8126
The Viega Eco Plus base element is not suitable for:
n Viegaswift bidet module model 8130.3 n Viegaswift WC module model 8039.3
Product information

2.2 Product description

2.2.1 Overview

Fig. 1: Component overview
1 - Viega Eco Plus base element 2 - fixing screws of the adjustable feet 3 - adjustable feet
Viega Eco Plus basic element 6 from 11
Page 7

3 Handling

3.1 Assembly information

3.1.1 Installation dimensions

Handling
Fig. 2: Dimensions model 8162.5

3.1.2 Required tools

The following tools are required for mounting:
n drill with 10 mm drill bit n fork or ring spanner: 13 mm / 17 mm
Viega Eco Plus basic element 7 from 11
Page 8

3.2 Assembly

X3
0-200
X1
X2
0
Ø10
560638_B2
13
0-200
0
1000
1
7

3.2.1 Mounting base element

Masonry wall
Handling
Determine and mark fixing points.
n X1: 390 mm (model 8180.73) n X2: 440 mm (model 8173) n X3: possible construction heights (depending on length of ele‐
ment): 960 mm, 1110 mm or 1280 mm
Observe construction height in accordance with the on-site marking of the upper edge of the finished floor.
Drill holes (10 mm).
Mount the fixing set with the fork spanner (size 13).
Determine construction height in accordance with the on-site marking of the upper edge of the finished floor.
Align the height of the feet with a fork spanner (size 17).
INFO! The construction height must be determined and adhered to exactly. There are only limited possibilities available to remedy errors made during this assembly step, Ä Chapter 3.1.1 „Installation dimensions“ on page 7.
Mark fixing points on the floor.
Viega Eco Plus basic element 8 from 11
Page 9
Set installation depth of the base element using a fork spanner
17
0-200
0
x
Ø10
13
0-200
0
(size 17). x = depending on the fitting holder or urinal module used
Remove base element and drill floor holes (10 mm).
Handling
Attach base element to the floor using the fork spanner (size 13) and the screws and dowels supplied.
Double clad base element with IFGP cladding panels (model
8055.10) (2 x 12.5 mm).
Viega Eco Plus basic element 9 from 11
Page 10
On-site support profile
90°
5
0
75
Ø10
13
0-200
0
1000
Handling
If necessary, adjust feet from 75 mm to 50 mm (pull out and turn).
Drill floor holes (10 mm).
Attach base element to the floor using the screws and dowels sup‐ plied (size 13).
Determine construction height in accordance with the on-site marking of the upper edge of the finished floor.
Align base element upwards, observe installation height marking.
INFO! The construction height must be determined and adhered to exactly. There are only limited possibilities available to remedy errors made during this assembly step, Ä Chapter 3.1.1 „Installation dimensions“ on page 7.
Viega Eco Plus basic element 10 from 11
Page 11
8x
Handling
Attach base element flush in the support profiles using the screws supplied.
Double-clad base element with IFGP cladding panels (model 8055.10) (2 x 12.5 mm).
3.3
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Viega Eco Plus basic element 11 from 11