Viega Advantix Top 4914.20 Instructions For Use Manual

for bonded sealing (tiled shower) with sealing mat Model Year built:
4914.20 from 01/2010
en_INT
Advantix Top bath drain
Instructions for Use
Table of contents
1 About these instructions for use 4
1.1
Target groups 4
1.2
Labelling of notes 4
1.3
About this translated version 5
2 Product information 6
2.1
Standards and regulations 6
2.2
Intended use 6
2.2.1
Areas of use 6
2.2.2
Media 7
2.2.3
Drainage capacity 7
2.3
Product description 7
2.3.1
Overview 7
2.3.2
Technical data 8
2.4
Information for use 8
2.4.1
Installation variations 8
2.4.2
Sealing 9
2.4.3
Fire protection 11
2.5
Required accessories 12
3 Handling 13
3.1
Assembly information 13
3.1.1
Important note 13
3.1.2
Installation dimensions 13
3.1.3
Tools and materials 13
3.2
Assembly 14
3.2.1
Construction and water seal level 14
3.2.2
Mount base unit 16
3.2.3
Sealing the drain 19
3.2.4
Mounting the top 21
3.3
Care 22
3.3.1
Care tips 22
3.3.2
Cleaning the drain 23
3.4
Disposal 24
Table of contents
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Tilers n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
viega.com/standards
.
Regulations from section: Sealing
Scope / Notice Regulations applicable in Ger-
many
Stress class of the underground, as well as suitable bonded sealing
ZDB-Merkblatt 8/2012
Stress class of the underground, as well as suitable bonded sealing
Leitfaden zur Abdichtung im Ver­bund (AIV)
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A and AO
ETAG 022 T1
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A, B and C
DIBt-Bauregelliste A, Teil 2 des DIBt und Prüfgrundsätze für Abdichtungen im Verbund (PG AIV-F)
Permitted bonded sealings EN 14891
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
many
Typical domestic wastewater DIN 1986-3
2.2 Intended use
2.2.1 Areas of use
The drain is designed for small to medium volumes of water, which occur in e. g. residential building.
Technical information, see
Ä Chapter 2.3.2 „Technical data“ on page 8
.
Product information
2.2.2 Media
n The short-term temperature of the wastewater may reach up to
95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
2.2.3 Drainage capacity
The drainage capacity is dependent on the chosen installation height. The drainage capacity is 0.8 l/s up to 1.2 l/s with horizontal DN 50 drain
support.
2.3 Product description
2.3.1 Overview
1
2
4
6
5
3
7
8
Fig. 1: Scope of delivery model 4914.20
1 - top with grate, can be cut to length 2 - sealing collar 3 - insert ring for top 4 - immersion pipe 5 - flange for the application of the bonded sealing
Product information
6 - base unit 7 - sound protection mat 8 - adjusting feet
2.3.2 Technical data
Nominal width [DN] (drain support)
50
Drainage capacity
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Dimensions and installa­tion height
Ä Chapter 3.1.2 „Installation dimen­sions“ on page 13
Water head seal 30 up to 50 mm
Load class K = 300 kg
2.4 Information for use
2.4.1 Installation variations
The mounting of the drain in a bare concrete floor is as follows:
n
The drain is placed in a floor recess and then cast-in.
Installing in a bare concrete floor
Fig. 2: General installation example – Floor recess
Product information