1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
n Consumers
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
WC tablet holder for Prevista4 from 13
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e.g. EN) and/or in Germany
(e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand‐
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
WC tablet holder for Prevista5 from 13
Page 6
2Product information
2.1Safety advice
WARNING!
Risk of malfunction of cardiac pacemakers and implanted
defibrillators due to magnets
The flush plate is fastened to the wall with magnets. Mag‐
nets may deteriorate or stop the functions of a cardiac
pacemaker, defibrillator or similar implanted devices.
A defibrillator may stop working in the vicinity of magnets.
– If you wear this type of implanted device, keep a dis‐
tance of at least 10 cm to the installed magnets.
– The operator must ensure that suitable measures have
been taken (safety sign, for instance) warning wearers of
such devices not to come too close to the installed mag‐
nets.
Product information
2.2Intended use
2.2.1Areas of use
The WC tablet holder for Prevista is used to feed freshener blocks into
the Prevista concealed cisterns.
The tablet holder is suitable for the concealed cisterns 3H and 3L.
The tablet holder is compatible with WC flush plates for Prevista.
NOTICE!
Chlorine and liquid cleaner may impair the function of the
cistern.
Do not use chlorine or liquid cleaner.
– Only use commercially available chlorine-free WC fresh‐
n The mechanism is placed on the cover plate.
n For new installations: The cistern and flush actuation have been
mounted.
n For retrofitting: The existing base frame and flush plate have been
removed. Retain the flush plate.
n For electronic flush plates: Mount the control on the cover plate of
the tablet holder.
Clip the tablet holder into the cover plate.
Handling
Insert the tablet holder into the revision shaft.
WC tablet holder for Prevista8 from 13
Page 9
Insert the cover plate all the way.
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
Turn the cover plate lock by 90° in a clockwise direction.
Engage the tablet holder.
Handling
Remove the top frame from the installation frame.
Put on the installation frame.
WC tablet holder for Prevista9 from 13
Page 10
Insert the retaining bolts.
$IMPS
$IMPSJOF
Turn the retaining bolts by 90° in a clockwise direction.
Handling
To fix the retaining bolts, turn safety rings in a clockwise direction.
Clip the safety clips into the top frame.
WC tablet holder for Prevista10 from 13
Page 11
Hook the safety clips into the installation frame.
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
Insert the top frame into the installation frame.
The tablet holder has been installed. The flush plate can be
ð
mounted.
Handling
INFO! Information for installation of the flush plate can
be found in the associated instructions for use.
WC tablet holder for Prevista11 from 13
Page 12
3.2Use
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
3.2.1Using the tablet holder
Handling
Requirements:
n The flush plate is mounted.
Use both your hands to pull the flush plate forward to remove it.
Remove the flush plate.
WC tablet holder for Prevista12 from 13
Page 13
Feed the freshener block into the tablet holder.
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
$IMPS
$IMPSJOF
NOTICE! Do not use liquid cleaner or chloric chemicals.
Use both your hands to raise the flush plate.
Handling
3.3
Replace the flush plate.
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.