WC flush plate for Prevista
Visign for More 204 electronic
Instructions for Use
for all Prevista concealed cisterns
ModelYear built:
8624.1from 03/2019
en_INT
Page 2
WC flush plate for Prevista Visign for More 204 electronic2 from 25
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.3.5
2.4
Intended use6
Areas of use6
General notes6
Product description7
Overview7
Technical data8
Connection diagram9
Operating mode9
System expansions10
Accessories10
3Handling13
3.1
3.1.1
3.1.2
3.2
3.2.1
3.2.2
3.2.3
3.3
3.3.1
3.4
3.5
3.5.1
3.6
Assembly information13
Mounting conditions13
Required material and tools13
Assembly13
Prepare cistern13
Mounting the flush plate14
Connecting external sensors21
Commissioning22
Setting the flush22
Errors, faults and remedy24
Care and maintenance24
Care tips24
Disposal25
WC flush plate for Prevista Visign for More 204 electronic3 from 25
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal.
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
n Consumers
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
WC flush plate for Prevista Visign for More 204 electronic4 from 25
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e.g. EN) and/or in Germany
(e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand‐
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
WC flush plate for Prevista Visign for More 204 electronic5 from 25
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
Suitable cisterns
The flush plate is intended for the actuation of flushes on Viega con‐
cealed cisterns.
Installation is possible in all Prevista concealed cisterns.
2.2General notes
n If you notice any damage on the product or individual components,
do not carry out a repair. Instead, have the product replaced by
qualified personnel.
n This product is not intended for use by persons (including children)
with restricted physical, sensory or mental aptitude or lack of experi‐
ence and/or knowledge.
n Make sure that children do not play with this product.
Product information
Symbols
Observe the symbol listed on the label:
CE marking, Product Safety in
Europe
EAC marking, registration of prod‐
ucts in the territory of the Cus‐
toms Union
Direct current
WC flush plate for Prevista Visign for More 204 electronic6 from 25
Page 7
1
234
5
Product information
Protection class III
The marked product must not be
disposed of as household waste.
2.3Product description
2.3.1Overview
Fig. 1: Scope of delivery
1flush plate
2Actuating rod
3retaining bolt
4silicon grease (2 x 2 g)
5installation frame
WC flush plate for Prevista Visign for More 204 electronic7 from 25
Page 8
2.3.2Technical data
Flush volume
Viega Hygiene+ function
Product information
The flush volumes for the flush actuation are:
n Small flush volume: approx. 2 / 3 / 4 litres
n Large flush volume: approx. 3.5 / 4.5 / 6 / 7.5 litres
For the setting of the flush see Ä Chapter 3.3.1 „Setting the flush“
on page 22.
WC flush plate for Prevista Visign for More 204 electronic8 from 25
Page 9
2.3.3Connection diagram
/
-
7_
7
EBUB
EBUB
Product information
Fig. 2: Connection diagram, power pack, WC flush plate for Prevista
1Power pack
2Control with motor
3WC flush plate for Prevista
2.3.4Operating mode
Flushes from Prevista concealed cisterns are actuated electronically via
the flush plate.
Optionally, a large or small flush volume can be flushed.
Viega Hygiene+ function
Stagnation can lead to the build up of germs (e.g. legionella) in potable
water pipelines. It is important to rinse the pipeline regularly to prevent
the build up of bacteria. The Viega Hygiene+ function was developed for
this reason.
Flushes are actuated in a time-controlled manner with the Viega
Hygiene+ function. Interval and flush volume will be set as required and
saved by the control. All settings remain saved during a power cut.
The function can be disabled.
WC flush plate for Prevista Visign for More 204 electronic9 from 25
Page 10
2.3.5System expansions
Radio controlled actuation
Product information
The system's range of functions can be expanded through the connec‐
tion of accessories onto the control.
You need the following accessories to connect a radio receiver instead
of a cable-connected external sensor:
2.4
Required accessories
Optional accessories
Accessories
Signals to actuate the flush (e. g. on support hinged handles) sent by
HEWI radio transmitters can be received by a radio receiver (model
8350.35).
For complete mounting of the electronic flush plate, you need the elec‐
tronic accessory set (model 8655.11).
WC installation frame with LED lighting (model 8650.1)
WC flush plate for Prevista Visign for More 204 electronic10 from 25
Page 11
Product information
The WC installation frame with LED lighting is a backlit installation frame
with proximity sensor.
installation set (model 8640.14)
The installation set contains a hollow wall socket to house the power
pack and an empty pipe to connect the cistern.
Extension cable (model 8352.690)
2 metre cable for the extension of the power supply.
Use a maximum of two extension cables with the power
pack (4.75 meter total length).
Connection cable (model 8570.55)
3-meter cable for external flush actuation with on-site with commercially
available buttons with closing function or potential-free contact (closing
period 350 ms)
WC flush plate for Prevista Visign for More 204 electronic11 from 25
Page 12
Product information
Y-cable (model 8580.49)
For connection of a radio receiver.
Battery compartment (model 8570.56)
The battery compartment can be connected for a redundant power
supply using the adapter. The battery compartment is included in the
adapter's scope of delivery.
WC remote actuation (models 8640.1 and 8641.1)
For electronic remote actuation at Prevista concealed cisterns.
WC flush plate for Prevista Visign for More 204 electronic12 from 25
Page 13
3Handling
3.1Assembly information
3.1.1Mounting conditions
External sensors (optional)
If external sensors are to be connected to the control, their connection
cables or empty pipes must be laid in the cistern before tiling is begun,
see Ä Chapter 2.3.5 „System expansions“ on page 10.
3.1.2Required material and tools
Material
The following material is required for mounting:
Handling
Tool
3.2Assembly
3.2.1Prepare cistern
n if necessary, accessories for the extension of the system Ä Chapter
2.3.5 „System expansions“ on page 10
The following tools are required for mounting:
n cutting knife
Requirements:
n The accessory set electronic (model 8655.11) is mounted.
n The cistern is fitted into the pre-wall.
n The pre-wall is tiled.
Remove the shaft cover.
WC flush plate for Prevista Visign for More 204 electronic13 from 25
Page 14
3.2.2Mounting the flush plate
Y
Handling
Cut into the corners of the revision shaft.
Fold the sides of the revision shaft outwards up to the tile level and
snap them off.
Turn the cover plate lock 90° in anti-clockwise direction.
Remove the cover plate.
WC flush plate for Prevista Visign for More 204 electronic14 from 25
Page 15
Close the corner valve.
Loosen the flexible hose at the filling valve.
Handling
Open the corner valve for a few seconds to flush the pipe.
Close the corner valve.
WC flush plate for Prevista Visign for More 204 electronic15 from 25
Page 16
Connect the flexible hose to the filling valve.
Re-open the corner valve.
INFO! Check the corner valve and the filling valve for leak tight‐
ness.
Handling
Set the desired flush volume, see Ä Chapter 3.3.1 „Setting
the flush“ on page 22.
Insert the cover plate into the cistern.
WC flush plate for Prevista Visign for More 204 electronic16 from 25
Page 17
Turn the cover plate lock by 90° in a clockwise direction.
Put on the installation frame.
Handling
Insert the retaining bolts.
Turn the retaining bolts by 90° in a clockwise direction.
WC flush plate for Prevista Visign for More 204 electronic17 from 25
Page 18
NN
)
NN
-
9
Handling
Align the installation frame.
To fix the retaining bolts, turn safety rings in a clockwise direction.
If you are not sure which cistern is installed, identify it by
means of the following dimensions.
n 3H concealed cistern
n concealed cistern 3L
INFO! For installation from the front into the concealed cisterns
3H, and 3L.
Determine the distance for the actuating rod.
WC flush plate for Prevista Visign for More 204 electronic18 from 25
Page 19
INFO! Cistern 3H and 3L.
9
If necessary, cut the actuating rod to length.
n 0: 75–50 mm
n 1: 50–25 mm
n 2: 25–10 mm
INFO! For installation from above into concealed cistern 3L.
Determine the distance for the actuating rod.
Handling
If necessary, cut the actuating rod to length.
n 0: 60–45 mm
n 1: 45–25 mm
n 2: 25–10 mm
Push the actuating rod through the left opening of the installation
frame as far as it will go.
WC flush plate for Prevista Visign for More 204 electronic19 from 25
Page 20
Align the actuating rod.
d
Turn the actuating rod clockwise by 90°.
Apply the silicon grease to the electronic connections.
Connect the control line to the flush plate.
Handling
If required, additional external sensors can be connected to the con‐
trol. See Ä Chapter 3.2.3 „Connecting external sensors“ on page 21.
Mount the flush plate.
The flush plate is mounted.
ð
WC flush plate for Prevista Visign for More 204 electronic20 from 25
Page 21
3.2.3Connecting external sensors
Requirements:
n Button with locking function or potential-free contact (closure time at
least 350 ms) available
n Connection cable available
Connect the contact to actuate the small flush volume between the
green (1) and yellow cable (3).
Handling
NOTICE!
Damage to property due to excess voltage
If you apply voltage to the connection cable for the external
button, you will damage the control.
– Do not apply any external voltage!
Fig. 3: WC flush plate, terminal assignment
for external sensors
Fig. 4: WC flush plate, terminal assignment
for external sensors
Connect the contact to actuate the large flush volume between the
green (1) and white cable (2).
Strip the end of the brown cable (e.g., with a lustre terminal).
WC flush plate for Prevista Visign for More 204 electronic21 from 25
Page 22
3.3Commissioning
1 2 3 4 5 6 7 8
"#$
3.3.1Setting the flush
Handling
The smallest possible flush volume must be set at the drain
valve in the cistern.
The flush volume is set via the DIP switches of the control.
ASetting of the flush volume
BInterval of the Viega Hygiene+ function
WC flush plate for Prevista Visign for More 204 electronic22 from 25
C Setting the flush volume of the Viega Hygiene+ function
0DIP switch position: OFF
1DIP switch position: ON
The assignment of the DIP switches:
n Switches 1-4 define the flush volume.
n Switches 5-7 define the interval of the Viega Hygiene+ function.
n Switch 8 defines the flush volume of the Viega Hygiene+ function.
Page 23
NOTICE!
Damage due to moisture
Risk of damage to the control if moisture penetrates.
– Do not remove the protective cover of the DIP switches.
Setting the flush volumes (A)
Handling
Program no.Large flush
volume (in litres)
Program 0
630000
Small flush
volume
(in litres)
Position of the
switches 1—4
1234
(factory set‐
ting)
Program 13.520001
Program 24.520010
Program 3620011
Program 47.520100
Program 53.530101
Program 64.530110
Program 77.530111
Program 84.541000
Program 9641001
Program 107.541010
Viega Enabling the Hygiene+ function and setting the intervals (B)
Interval (in hours)Position of switches 5—7
567
Switched off000
1001
12010
24011
72100
168101
WC flush plate for Prevista Visign for More 204 electronic23 from 25
Page 24
Setting the flush volume of the Viega Hygiene+ function (C)
Flush volume (in litres)Position of switch 8
30
7.51
3.4Errors, faults and remedy
ErrorCauseRemedy
The WC does not flush.The supply voltage has failed.Check the power supply.
Handling
The cistern is not yet completely
full.
There is no water in the cistern.
The corner valve is closed.
The control is defective.Replace the control.
The plugs of control and flush
plate have not been connected.
The WC flush runs through.The seal at the filling valve is dirty
or damaged.
The seal at the drain valve is dirty
or damaged.
3.5Care and maintenance
3.5.1Care tips
Use normal soap or a mild cleaning agent for regular care and preven‐
tion of lime scale on the flush plate. Under no circumstances should
scouring agent or scratching objects be used.
Wait until the cistern is sufficiently
full.
Open the corner valve.
Establish the plug connection.
Ä
Chapter 3.2.2 „Mounting the
flush plate“ on page 14
Check the seal, replace if neces‐
sary.
Check the seal, replace if neces‐
sary.
Strong stains can be removed using typical household cleaner. Rinse
the detergent thoroughly with clear water after the prescribed exposure
time. There should be no residue on the components.
WC flush plate for Prevista Visign for More 204 electronic24 from 25
Page 25
3.6Disposal
Handling
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Electronic components and batteries must not be put in the domestic
waste but must be disposed of appropriately in conformity with the
WEEE guideline 2012/19/EU.
WC flush plate for Prevista Visign for More 204 electronic25 from 25