Viega 8624.1 Instructions For Use Manual

Page 1
WC flush plate for Prevista Visign for More 204 electronic
Instructions for Use
for all Prevista concealed cisterns
Model Year built:
8624.1 from 03/2019
en_INT
Page 2
WC flush plate for Prevista Visign for More 204 electronic 2 from 25
Page 3
1 About these instructions for use 4
Table of contents
1.1
1.2
1.3
Target groups 4
Labelling of notes 4
About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.3.5
2.4
Intended use 6
Areas of use 6
General notes 6
Product description 7
Overview 7
Technical data 8
Connection diagram 9
Operating mode 9
System expansions 10
Accessories 10
3 Handling 13
3.1
3.1.1
3.1.2
3.2
3.2.1
3.2.2
3.2.3
3.3
3.3.1
3.4
3.5
3.5.1
3.6
Assembly information 13
Mounting conditions 13
Required material and tools 13
Assembly 13
Prepare cistern 13
Mounting the flush plate 14
Connecting external sensors 21
Commissioning 22
Setting the flush 22
Errors, faults and remedy 24
Care and maintenance 24
Care tips 24
Disposal 25
WC flush plate for Prevista Visign for More 204 electronic 3 from 25
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document; for further information, go to viega.com/legal.

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns of possible life-threatening injury.
WARNING! This symbol warns of possible serious injury.
CAUTION! This symbol warns of possible injury.
NOTICE! This symbol warns of possible damage to property.
This symbol gives additional information and hints.
WC flush plate for Prevista Visign for More 204 electronic 4 from 25
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand‐ ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
WC flush plate for Prevista Visign for More 204 electronic 5 from 25
Page 6

2 Product information

2.1 Intended use

2.1.1 Areas of use

Suitable cisterns
The flush plate is intended for the actuation of flushes on Viega con‐ cealed cisterns.
Installation is possible in all Prevista concealed cisterns.

2.2 General notes

n If you notice any damage on the product or individual components,
do not carry out a repair. Instead, have the product replaced by qualified personnel.
n This product is not intended for use by persons (including children)
with restricted physical, sensory or mental aptitude or lack of experi‐ ence and/or knowledge.
n Make sure that children do not play with this product.
Product information
Symbols
Observe the symbol listed on the label:
CE marking, Product Safety in Europe
EAC marking, registration of prod‐ ucts in the territory of the Cus‐ toms Union
Direct current
WC flush plate for Prevista Visign for More 204 electronic 6 from 25
Page 7
1
234
5
Product information
Protection class III
The marked product must not be disposed of as household waste.

2.3 Product description

2.3.1 Overview

Fig. 1: Scope of delivery
1 flush plate 2 Actuating rod 3 retaining bolt 4 silicon grease (2 x 2 g) 5 installation frame
WC flush plate for Prevista Visign for More 204 electronic 7 from 25
Page 8

2.3.2 Technical data

Flush volume
Viega Hygiene+ function
Product information
The flush volumes for the flush actuation are:
n Small flush volume: approx. 2 / 3 / 4 litres n Large flush volume: approx. 3.5 / 4.5 / 6 / 7.5 litres
For the setting of the flush see Ä Chapter 3.3.1 „Setting the flush“ on page 22.
Hygiene flush volume 3 / 7.5 litres
Hygiene flush interval 1 / 12 / 24 / 72 / 168 hours
Voltage and current
Voltage [V] Current [A]
6 0.8
WC flush plate for Prevista Visign for More 204 electronic 8 from 25
Page 9

2.3.3 Connection diagram

/
-
7_
7
EBUB
EBUB




Product information
Fig. 2: Connection diagram, power pack, WC flush plate for Prevista
1 Power pack 2 Control with motor 3 WC flush plate for Prevista

2.3.4 Operating mode

Flushes from Prevista concealed cisterns are actuated electronically via the flush plate.
Optionally, a large or small flush volume can be flushed.
Viega Hygiene+ function
Stagnation can lead to the build up of germs (e.g. legionella) in potable water pipelines. It is important to rinse the pipeline regularly to prevent the build up of bacteria. The Viega Hygiene+ function was developed for this reason.
Flushes are actuated in a time-controlled manner with the Viega Hygiene+ function. Interval and flush volume will be set as required and saved by the control. All settings remain saved during a power cut.
The function can be disabled.
WC flush plate for Prevista Visign for More 204 electronic 9 from 25
Page 10

2.3.5 System expansions

Radio controlled actuation
Product information
The system's range of functions can be expanded through the connec‐ tion of accessories onto the control.
You need the following accessories to connect a radio receiver instead of a cable-connected external sensor:
2.4
Required accessories
Optional accessories
Accessories
Signals to actuate the flush (e. g. on support hinged handles) sent by HEWI radio transmitters can be received by a radio receiver (model
8350.35).
For complete mounting of the electronic flush plate, you need the elec‐ tronic accessory set (model 8655.11).
WC installation frame with LED lighting (model 8650.1)
WC flush plate for Prevista Visign for More 204 electronic 10 from 25
Page 11
Product information
The WC installation frame with LED lighting is a backlit installation frame with proximity sensor.
installation set (model 8640.14)
The installation set contains a hollow wall socket to house the power pack and an empty pipe to connect the cistern.
Extension cable (model 8352.690)
2 metre cable for the extension of the power supply.
Use a maximum of two extension cables with the power pack (4.75 meter total length).
Connection cable (model 8570.55)
3-meter cable for external flush actuation with on-site with commercially available buttons with closing function or potential-free contact (closing period 350 ms)
WC flush plate for Prevista Visign for More 204 electronic 11 from 25
Page 12
Product information
Y-cable (model 8580.49)
For connection of a radio receiver.
Battery compartment (model 8570.56)
The battery compartment can be connected for a redundant power supply using the adapter. The battery compartment is included in the adapter's scope of delivery.
WC remote actuation (models 8640.1 and 8641.1)
For electronic remote actuation at Prevista concealed cisterns.
WC flush plate for Prevista Visign for More 204 electronic 12 from 25
Page 13

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

External sensors (optional)
If external sensors are to be connected to the control, their connection cables or empty pipes must be laid in the cistern before tiling is begun, see Ä Chapter 2.3.5 „System expansions“ on page 10.

3.1.2 Required material and tools

Material
The following material is required for mounting:
Handling
Tool

3.2 Assembly

3.2.1 Prepare cistern

n if necessary, accessories for the extension of the system Ä Chapter
2.3.5 „System expansions“ on page 10
The following tools are required for mounting:
n cutting knife
Requirements:
n The accessory set electronic (model 8655.11) is mounted. n The cistern is fitted into the pre-wall. n The pre-wall is tiled.
Remove the shaft cover.
WC flush plate for Prevista Visign for More 204 electronic 13 from 25
Page 14

3.2.2 Mounting the flush plate

Y
Handling
Cut into the corners of the revision shaft.
Fold the sides of the revision shaft outwards up to the tile level and snap them off.
Turn the cover plate lock 90° in anti-clockwise direction.
Remove the cover plate.
WC flush plate for Prevista Visign for More 204 electronic 14 from 25
Page 15
Close the corner valve.
Loosen the flexible hose at the filling valve.
Handling
Open the corner valve for a few seconds to flush the pipe.
Close the corner valve.
WC flush plate for Prevista Visign for More 204 electronic 15 from 25
Page 16
Connect the flexible hose to the filling valve.
Re-open the corner valve.
INFO! Check the corner valve and the filling valve for leak tight‐ ness.
Handling
Set the desired flush volume, see Ä Chapter 3.3.1 „Setting the flush“ on page 22.
Insert the cover plate into the cistern.
WC flush plate for Prevista Visign for More 204 electronic 16 from 25
Page 17
Turn the cover plate lock by 90° in a clockwise direction.
Put on the installation frame.
Handling
Insert the retaining bolts.
Turn the retaining bolts by 90° in a clockwise direction.
WC flush plate for Prevista Visign for More 204 electronic 17 from 25
Page 18
NN
)
NN
-
9
Handling
Align the installation frame.
To fix the retaining bolts, turn safety rings in a clockwise direction.
If you are not sure which cistern is installed, identify it by means of the following dimensions.
n 3H concealed cistern
n concealed cistern 3L
INFO! For installation from the front into the concealed cisterns 3H, and 3L.
Determine the distance for the actuating rod.
WC flush plate for Prevista Visign for More 204 electronic 18 from 25
Page 19
INFO! Cistern 3H and 3L.
9
If necessary, cut the actuating rod to length.
n 0: 75–50 mm n 1: 50–25 mm n 2: 25–10 mm
INFO! For installation from above into concealed cistern 3L.
Determine the distance for the actuating rod.
Handling
If necessary, cut the actuating rod to length.
n 0: 60–45 mm n 1: 45–25 mm n 2: 25–10 mm
Push the actuating rod through the left opening of the installation frame as far as it will go.
WC flush plate for Prevista Visign for More 204 electronic 19 from 25
Page 20
Align the actuating rod.

d
Turn the actuating rod clockwise by 90°.
Apply the silicon grease to the electronic connections.
Connect the control line to the flush plate.
Handling
If required, additional external sensors can be connected to the con‐ trol. See Ä Chapter 3.2.3 „Connecting external sensors“ on page 21.
Mount the flush plate.
The flush plate is mounted.
ð
WC flush plate for Prevista Visign for More 204 electronic 20 from 25
Page 21

3.2.3 Connecting external sensors

Requirements:
n Button with locking function or potential-free contact (closure time at
least 350 ms) available
n Connection cable available
Connect the contact to actuate the small flush volume between the green (1) and yellow cable (3).
Handling
NOTICE! Damage to property due to excess voltage
If you apply voltage to the connection cable for the external button, you will damage the control.
– Do not apply any external voltage!
Fig. 3: WC flush plate, terminal assignment for external sensors
Fig. 4: WC flush plate, terminal assignment for external sensors
Connect the contact to actuate the large flush volume between the green (1) and white cable (2).
Strip the end of the brown cable (e.g., with a lustre terminal).
WC flush plate for Prevista Visign for More 204 electronic 21 from 25
Page 22

3.3 Commissioning

1 2 3 4 5 6 7 8

"#$

3.3.1 Setting the flush

Handling
The smallest possible flush volume must be set at the drain valve in the cistern.
The flush volume is set via the DIP switches of the control.
A Setting of the flush volume B Interval of the Viega Hygiene+ function
WC flush plate for Prevista Visign for More 204 electronic 22 from 25
C Setting the flush volume of the Viega Hygiene+ function 0 DIP switch position: OFF 1 DIP switch position: ON
The assignment of the DIP switches:
n Switches 1-4 define the flush volume. n Switches 5-7 define the interval of the Viega Hygiene+ function. n Switch 8 defines the flush volume of the Viega Hygiene+ function.
Page 23
NOTICE! Damage due to moisture
Risk of damage to the control if moisture penetrates.
– Do not remove the protective cover of the DIP switches.
Setting the flush volumes (A)
Handling
Program no. Large flush
volume (in litres)
Program 0
6 3 0 0 0 0
Small flush volume (in litres)
Position of the switches 1—4
1 2 3 4
(factory set‐ ting)
Program 1 3.5 2 0 0 0 1
Program 2 4.5 2 0 0 1 0
Program 3 6 2 0 0 1 1
Program 4 7.5 2 0 1 0 0
Program 5 3.5 3 0 1 0 1
Program 6 4.5 3 0 1 1 0
Program 7 7.5 3 0 1 1 1
Program 8 4.5 4 1 0 0 0
Program 9 6 4 1 0 0 1
Program 10 7.5 4 1 0 1 0
Viega Enabling the Hygiene+ function and setting the intervals (B)
Interval (in hours) Position of switches 5—7
5 6 7
Switched off 0 0 0
1 0 0 1
12 0 1 0
24 0 1 1
72 1 0 0
168 1 0 1
WC flush plate for Prevista Visign for More 204 electronic 23 from 25
Page 24
Setting the flush volume of the Viega Hygiene+ function (C)
Flush volume (in litres) Position of switch 8
3 0
7.5 1

3.4 Errors, faults and remedy

Error Cause Remedy
The WC does not flush. The supply voltage has failed. Check the power supply.
Handling
The cistern is not yet completely full.
There is no water in the cistern. The corner valve is closed.
The control is defective. Replace the control.
The plugs of control and flush plate have not been connected.
The WC flush runs through. The seal at the filling valve is dirty
or damaged.
The seal at the drain valve is dirty or damaged.

3.5 Care and maintenance

3.5.1 Care tips

Use normal soap or a mild cleaning agent for regular care and preven‐ tion of lime scale on the flush plate. Under no circumstances should scouring agent or scratching objects be used.
Wait until the cistern is sufficiently full.
Open the corner valve.
Establish the plug connection.
Ä
Chapter 3.2.2 „Mounting the
flush plate“ on page 14
Check the seal, replace if neces‐ sary.
Check the seal, replace if neces‐ sary.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.
WC flush plate for Prevista Visign for More 204 electronic 24 from 25
Page 25

3.6 Disposal

Handling
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Electronic components and batteries must not be put in the domestic waste but must be disposed of appropriately in conformity with the WEEE guideline 2012/19/EU.
WC flush plate for Prevista Visign for More 204 electronic 25 from 25
Loading...