Prevista Dry Plus fitting holder for wallmounted fitting, reinforced
Instructions for Use
for wall-mounted fitting
ModelYear built:
8555.31from 01/2019
en_INT
Page 2
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced2 from 10
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.2
2.2.1
2.3
2.3.1
2.3.2
Standards and regulations6
Intended use6
Areas of use6
Product description7
Overview7
Compatible components7
3Handling8
3.1
3.1.1
3.2
3.2.1
3.2.2
3.3
Assembly information8
Installation dimensions8
Assembly8
Mounting module8
Rounding off jobs10
Disposal10
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced3 from 10
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal.
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Consumers
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced4 from 10
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e.g. EN) and/or in Germany
(e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand‐
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced5 from 10
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe and
are provided as a support feature.
Regulations from section: Fields of application / Mounting conditions
Scope / NoticeRegulations applicable in Ger‐
Suitable masonry wallsEN 1996-1-1
Suitable concreted wallsDIN 1045
Product information
many
2.2Intended use
2.2.1Areas of use
The fitting holder is suitable for mounting on wall constructions pursuant
to the regulations in section Ä „Regulations from section: Fields of
application / Mounting conditions“ on page 6 and is intended for use in
a Prevista Dry Plus pre-wall construction.
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced6 from 10
Page 7
2.3Product description
2.3.1Overview
Product information
Fig. 1: Scope of delivery
1Fitting holders
2Screws for fixing in support profile
3slot nuts
4connections for wall plates
2.3.2Compatible components
The fitting holder is intended for use with a wall-mounted fitting.
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced7 from 10
Page 8
3Handling
3.1Assembly information
3.1.1Installation dimensions
Handling
Fig. 2: Installation dimensions
3.2Assembly
3.2.1Mounting module
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced8 from 10
Use the slot nuts supplied to attach the fitting holder to the open
mounting rail.
Insert the slot nut into the opening of the module.
Page 9
Push the slot nut in until it engages.
25 Nm
Set the height of the rail.
Handling
Fasten the slot nut.
Bend the sides of the metal bars of the fitting holder.
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced9 from 10
Page 10
9
İ
Handling
Attach the wall plate fixings and the wall plates.
Set the height of the fitting holder according to the information of
the sanitary item manufacturer.
3.2.2Rounding off jobs
3.3
Disposal
Clad the pre-wall with suitable gypsum cardboard cladding panels.
Make sure that no abutting edges converge.
Grout the abutting edges and joints with a suitable filler.
For more detailed information, observe the mounting instructions for
the gypsum cardboard cladding panels.
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Prevista Dry Plus fitting holder for wall-mounted fitting, reinforced10 from 10