for tile-level installation of the WC flush plate, natural stone covering supplied by others
ModelYear built:
8332.3from 06/2009
en_INT
Page 2
Functional unit2 from 15
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
Intended use6
Areas of use6
Product description6
Overview6
Technical data6
3Handling7
3.1
3.1.1
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.3
3.3.1
3.4
3.5
Assembly information7
Required material and tools7
Assembly8
Mounting the functional unit8
Prepare cistern10
Mount flush actuation12
Mounting the flush plate13
Commissioning14
Setting the flush14
Error, faults and remedy15
Disposal15
Functional unit3 from 15
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document, further information can be
found at
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Functional unit4 from 15
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Functional unit5 from 15
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
The functional unit for natural stone panels is suitable for the tile-level
installation of flush plates with individually laid natural stone supplied
on-site.
The functional unit is suitable for concealed cisterns of the following
pre-wall systems:
n Viega Steptec
n Viegaswift
n Viega Eco Plus
Product information
2.2Product description
2.2.1Overview
Fig. 1: Component overview
2.2.2Technical data
The product has the following technical data:
Functional unit6 from 15
Page 7
3Handling
3.1Assembly information
3.1.1Required material and tools
Material
The following material is required for mounting:
n Pactan cleaning agent 14
n Pactan silicone adhesive 7043
n Natural stone panel
Handling
Functional unit7 from 15
Page 8
3.2Assembly
3.2.1Mounting the functional unit
Mark the internal contour (280 x 150 mm) of the installation frame on
the cladding panel.
Use a keyhole saw to cut the cladding panel out along the dimension line.
Clad the remaining pre-wall according to the Viega specifications.
Dispose of the cover of the revision shaft.
Handling
Align the installation frame centrally over the revision shaft.
A length of double-faced adhesive tape is provided at one side of
the installation frame.
Stick the installation frame onto the cladding panel.
Adjust the chrome-plated internal frame to the respective wall covering.
The upper edge of the chrome-plated internal frame must be flush
with the wall tile.
Setting range 5–18 mm.
INFO! Make allowance for the thickness of the tile adhesive!
Functional unit8 from 15
Page 9
Handling
Shorten revision shaft flush with the chrome-plated internal frame.
INFO!
– First, cut the corners of the revision shaft.
– Then fold the sides.
Mount the cover onto the internal frame.
Have the tiler tile the pre-wall.
Functional unit9 from 15
Page 10
Handling
3.2.2
Fig. 2: Dimensional drawing 8332.3
Cut the natural stone coverings according to the dimensional
drawing.
Take the tolerance and thickness of the covering into consideration.
Ensure that the plastic surfaces are clean, dry, and free of grease.
Apply Pactan adhesive cleaner 14 to the plastic surfaces to which
you will attach the stone coverings – do not apply to the stone!
If applied correctly, the adhesive cleaner leaves a thin film on the
plastic surface.
Use Pactan silicone adhesive 7043 to glue the natural stone cov-
ering into the recess of the flush plate.
Allow the adhesive to cure completely.
Place the functional unit onto the basic panel.
Prepare cistern
The following work stages and diagrams differ depending
on the cistern being used. The relevant steps are marked
accordingly.
Functional unit10 from 15
Page 11
Requirements:
n The cistern is fitted into the pre-wall.
n The pre-wall is tiled.
Remove cistern cover.
Remove and keep the threaded bolts from the cistern cover.
Handling
INFO! Only for assembly of the flush plate in cistern 2H or on the
front of cistern 2L.
Press the bow backwards from the mounting of the mechanism.
INFO! Only for assembly of the flush plate on the top of cistern
2L.
Press the bow backwards from the mounting of the mechanism.
Functional unit11 from 15
Page 12
Handling
Turn the mechanism's lock by 90° in an anti-clockwise direction.
The mechanism is unlocked and can be removed.
ð
Remove and dispose of mechanism.
3.2.3Mount flush actuation
Mount Bowden cable unit
INFO! Only with the cistern 2H.
Remove and keep spacer.
Functional unit12 from 15
Page 13
Push the Bowden cable unit onto the drain valve from the left.
The Bowden cable unit must be felt to click into place on the drain
valve.
INFO! Only with the cistern 2H.
Re-insert the spacer.
Handling
3.2.4Mounting the flush plate
Requirements:
n The flush actuation has been mounted.
Insert the threaded bolts left and right into the holders.
The threaded anchors must be positioned to the top and bottom.
Functional unit13 from 15
Page 14
20
Handling
Insert the threaded bolts so deeply that the upper edge of the
threaded bolt sticks out approx. 20 mm behind the upper edge of
the tiles.
Fasten threaded bolts with a 90° turn.
Mount Bowden cable unit onto the rear side of the basic panel.
INFO! Observe the colour of the adapter!
3.3
Commissioning
3.3.1Setting the flush
Screw on basic panel.
Functional unit14 from 15
Page 15
Set the flush volume on the drain valve of the cistern.
3.4Error, faults and remedy
ErrorCauseRemedy
Handling
WC does not flushCistern is not yet completely fullWait until the cistern is sufficiently
full
No water in cistern, corner valve is
closed
WC flush runs throughDirty seal in filling valveCheck seal, replace if necessary
Dirty seal in drain valveCheck seal, replace if necessary
WC flush actuation does not workThe mechanism is not connected
to the bow
Bowden cable unit not properly
mounted on drain valve or basic
panel.
Open corner valve
Hang the mechanism in the bow
Check the position of the Bowden
cable unit.
3.5Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.