Viega 8326.1, 8327.1 Instructions For Use Manual

Page 1
Flush plate Visign for Public 1
Instructions for Use
for concealed cistern 2H, concealed cistern 2L, concealed cis­tern 2C, concealed cistern Standard 2S
Model Year built:
8326.1 from 01/2011
en_INT
Page 2
Flush plate Visign for Public 1 2 from 20
Page 3
1 About these instructions for use 4
Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
2.2.2
Intended use 6 Areas of use 6 Product description 7 Overview 7 Technical data 7
3 Handling 8
3.1
3.1.1
3.2
3.2.1
3.2.2
3.2.3
3.3
3.3.1
3.4
3.5
3.5.1
3.6
Assembly information 8 Required material and tools 8 Assembly 8 Prepare cistern 8 Mount flush actuation 14 Mounting the flush plate 17 Commissioning 19 Setting the flush 19 Error, faults and remedy 19 Care and maintenance 20 Maintenance tips 20 Disposal 20
Flush plate Visign for Public 1 3 from 20
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Flush plate Visign for Public 1 4 from 20
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Flush plate Visign for Public 1 5 from 20
Page 6

2 Product information

2.1 Intended use

2.1.1 Areas of use

Suitable cisterns
The flush plate is intended for the actuation of flushes on Viega con­cealed cisterns.
Installation is only possible in the following Viega concealed cisterns:
n Cistern model 2H n Cistern model 2L
Ascertain which model is installed before mounting. The following infor­mation will help you to determine the model of the cistern installed:
Cistern 2H
Product information
The revision shaft of this cistern is found at a height of approx. 1 metre on the front.
Cistern 2L The revision shaft of this cistern is either found at a height of approx.
75 cm on the front or on the top.
Flush plate Visign for Public 1 6 from 20
Page 7

2.2 Product description

1 2 3 4
5

2.2.1 Overview

Product information

2.2.2 Technical data

Flush volume
Fig. 1: Component overview
1 - basic panel 2 - holding panel 3 - flush plate with fixing screws 4 - actuating rod 5 - threaded bolt
The product exhibits the following technical data:
A flush with the large flush volume is always released via the flush plate. The flush volume is approx. 6–9 litres.
For the setting of the flush see
on page 19
.
Ä Chapter 3.3.1 „Setting the flush“
Flush plate Visign for Public 1 7 from 20
Page 8

3 Handling

3.1 Assembly information

3.1.1 Required material and tools

Tool
The following tools are required for mounting:
n flat screwdriver n Torx screwdriver (T 10) n knife (cutter)

3.2 Assembly

Handling

3.2.1 Prepare cistern

The following work stages and diagrams differ depending on the cistern being used. The relevant steps are marked accordingly.
Requirements:
n The cistern is fitted into the front wall. n The front wall is tiled.
Cut into shaft cover.
Flush plate Visign for Public 1 8 from 20
Page 9
Handling
Remove shaft cover.
Score the revision shaft along the edge of the tiles with a knife. Angle the knife to do this so that the cut is made flush to the surface
of the wall.
Cut the corners of the revision shaft vertically through to the wall surface.
Bend out and pull down the sides of the revision shaft. The edge of the revisions shaft must be flush with the wall surface.
Flush plate Visign for Public 1 9 from 20
Page 10
Handling
Remove cistern cover. Remove and keep the threaded bolts from the cistern cover. Keep cistern casing.
INFO! Only for assembly of the flush plate in cistern 2H or on the front of cistern 2L.
Press the bow backwards from the mounting of the mechanism.
INFO! Only for assembly of the flush plate on the top of cistern 2L.
Press the bow backwards from the mounting of the mechanism.
Turn the mechanism's lock by 90° in an anti-clockwise direction.
The mechanism is unlocked and can be removed.
ð
Flush plate Visign for Public 1 10 from 20
Page 11
Flush pipelines (cistern 2H)
Handling
Remove and keep mechanism.
Requirements:
n The revision shaft is shortened in such a way that it is flush with the
surface.
n Mechanism has been removed.
Close corner valve.
Loosen flexible hose on the filling valve (SW 19).
Flush plate Visign for Public 1 11 from 20
Page 12
Open the corner valve for a few seconds to rinse the pipe. Re-close corner valve.
Connect the flexible hose onto the filling valve (SW 19).
Handling
Open corner valve.
Flush plate Visign for Public 1 12 from 20
Page 13
Flush pipelines (cistern 2L)
Handling
Requirements:
n The revision shaft is shortened in such a way that it is flush with the
upper edge of the tiles.
n Mechanism has been removed.
Close corner valve.
Loosen flexible hose on the filling valve (SW 19).
Open the corner valve for a few seconds to rinse the pipe. Re-close corner valve.
Flush plate Visign for Public 1 13 from 20
Page 14
Connect the flexible hose onto the filling valve.
Open corner valve.
Handling

3.2.2 Mount flush actuation

Mount mechanism (cistern 2H)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 1 14 from 20
Page 15
Insert mechanism. The mechanism must sit exactly in the recesses in the cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð
Handling
Mount mechanism (cistern 2L)
Vertical installation (flush plate on the front of the cistern)
How to install the mechanism depends on whether the flush plate is to be fitted to the front or top of the cistern.
Vertical installation (flush plate on the front of the cistern)
Horizontal installation (flush plate on the top of the cis­tern)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 1 15 from 20
Page 16
Insert mechanism. The mechanism must sit exactly in the recesses in the cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð
Handling
Horizontal installation (flush plate on the top of the cistern)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 1 16 from 20
Page 17
Handling
Insert mechanism. In doing so, ensure that the tracks on the top and bottom edge of
the mechanism are in the indentations in the revision shaft of the cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð

3.2.3 Mounting the flush plate

Requirements:
n The flush actuation has been mounted.
Re-mount cistern casing.
Flush plate Visign for Public 1 17 from 20
Page 18
Handling
Insert the threaded bolts so deeply that the upper edge of the threaded bolt sticks out approx. 15 mm behind the upper edge of the tiles.
Secure threaded bolts with a 90° turn.
Screw actuating rod into the tapped hole.
Set the screw-in depth flush with the upper edge of the tiles with the help of the template supplied.
Screw on basic panel.
Flush plate Visign for Public 1 18 from 20
Page 19
Mount holding plates and basic panels.
Mount and screw flush plate tight.
Handling

3.3 Commissioning

3.3.1 Setting the flush

Set the flush volume on the drain valve of the cistern. Large flush volume: approx. 6–9 litres
3.4
Error Cause Remedy
WC does not flush Cistern is not yet completely full Wait until the cistern is sufficiently
Error, faults and remedy
No water in cistern, corner valve is closed
full
Open corner valve
WC flush runs through Dirty seal in filling valve Check seal, replace if necessary
Flush plate Visign for Public 1 19 from 20
Page 20
Error Cause Remedy
Dirty seal in drain valve Check seal, replace if necessary
Handling
WC flush actuation does not work The mechanism is not connected
to the bow

3.5 Care and maintenance

3.5.1 Maintenance tips

Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the flush plate. Under no circumstances should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.

3.6 Disposal

Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Hang the mechanism in the bow
Flush plate Visign for Public 1 20 from 20