for concealed cistern 2H, concealed cistern 2L, concealed cistern 2C, concealed cistern Standard 2S
ModelYear built:
8326.1from 01/2011
en_INT
Page 2
Flush plate Visign for Public 12 from 20
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
Intended use6
Areas of use6
Product description7
Overview7
Technical data7
3Handling8
3.1
3.1.1
3.2
3.2.1
3.2.2
3.2.3
3.3
3.3.1
3.4
3.5
3.5.1
3.6
Assembly information8
Required material and tools8
Assembly8
Prepare cistern8
Mount flush actuation14
Mounting the flush plate17
Commissioning19
Setting the flush19
Error, faults and remedy19
Care and maintenance20
Maintenance tips20
Disposal20
Flush plate Visign for Public 13 from 20
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document, further information can be
found at
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Consumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Flush plate Visign for Public 14 from 20
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Flush plate Visign for Public 15 from 20
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
Suitable cisterns
The flush plate is intended for the actuation of flushes on Viega concealed cisterns.
Installation is only possible in the following Viega concealed cisterns:
n Cistern model 2H
n Cistern model 2L
Ascertain which model is installed before mounting. The following information will help you to determine the model of the cistern installed:
Cistern 2H
Product information
The revision shaft of this cistern is found at a height of approx. 1 metre
on the front.
Cistern 2L
The revision shaft of this cistern is either found at a height of approx.
The product exhibits the following technical data:
A flush with the large flush volume is always released via the flush plate.
The flush volume is approx. 6–9 litres.
For the setting of the flush see
on page 19
.
Ä Chapter 3.3.1 „Setting the flush“
Flush plate Visign for Public 17 from 20
Page 8
3Handling
3.1Assembly information
3.1.1Required material and tools
Tool
The following tools are required for mounting:
n flat screwdriver
n Torx screwdriver (T 10)
n knife (cutter)
3.2Assembly
Handling
3.2.1Prepare cistern
The following work stages and diagrams differ depending
on the cistern being used. The relevant steps are marked
accordingly.
Requirements:
n The cistern is fitted into the front wall.
n The front wall is tiled.
Cut into shaft cover.
Flush plate Visign for Public 18 from 20
Page 9
Handling
Remove shaft cover.
Score the revision shaft along the edge of the tiles with a knife.
Angle the knife to do this so that the cut is made flush to the surface
of the wall.
Cut the corners of the revision shaft vertically through to the wall
surface.
Bend out and pull down the sides of the revision shaft.
The edge of the revisions shaft must be flush with the wall surface.
Flush plate Visign for Public 19 from 20
Page 10
Handling
Remove cistern cover.
Remove and keep the threaded bolts from the cistern cover.
Keep cistern casing.
INFO! Only for assembly of the flush plate in cistern 2H or on the
front of cistern 2L.
Press the bow backwards from the mounting of the mechanism.
INFO! Only for assembly of the flush plate on the top of cistern
2L.
Press the bow backwards from the mounting of the mechanism.
Turn the mechanism's lock by 90° in an anti-clockwise direction.
The mechanism is unlocked and can be removed.
ð
Flush plate Visign for Public 110 from 20
Page 11
Flush pipelines (cistern 2H)
Handling
Remove and keep mechanism.
Requirements:
n The revision shaft is shortened in such a way that it is flush with the
surface.
n Mechanism has been removed.
Close corner valve.
Loosen flexible hose on the filling valve (SW 19).
Flush plate Visign for Public 111 from 20
Page 12
Open the corner valve for a few seconds to rinse the pipe.
Re-close corner valve.
Connect the flexible hose onto the filling valve (SW 19).
Handling
Open corner valve.
Flush plate Visign for Public 112 from 20
Page 13
Flush pipelines (cistern 2L)
Handling
Requirements:
n The revision shaft is shortened in such a way that it is flush with the
upper edge of the tiles.
n Mechanism has been removed.
Close corner valve.
Loosen flexible hose on the filling valve (SW 19).
Open the corner valve for a few seconds to rinse the pipe.
Re-close corner valve.
Flush plate Visign for Public 113 from 20
Page 14
Connect the flexible hose onto the filling valve.
Open corner valve.
Handling
3.2.2Mount flush actuation
Mount mechanism (cistern 2H)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 114 from 20
Page 15
Insert mechanism.
The mechanism must sit exactly in the recesses in the cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð
Handling
Mount mechanism (cistern 2L)
Vertical installation (flush plate
on the front of the cistern)
How to install the mechanism depends on whether the flush
plate is to be fitted to the front or top of the cistern.
–
Vertical installation (flush plate on the front of the cistern)
–
Horizontal installation (flush plate on the top of the cistern)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 115 from 20
Page 16
Insert mechanism.
The mechanism must sit exactly in the recesses in the cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð
Handling
Horizontal installation (flush
plate on the top of the cistern)
Hang the mechanism in the bow of the drain valve.
Flush plate Visign for Public 116 from 20
Page 17
Handling
Insert mechanism.
In doing so, ensure that the tracks on the top and bottom edge of
the mechanism are in the indentations in the revision shaft of the
cistern.
Turn the mechanism's lock by 90° in a clockwise direction.
The mechanism is locked.
ð
3.2.3Mounting the flush plate
Requirements:
n The flush actuation has been mounted.
Re-mount cistern casing.
Flush plate Visign for Public 117 from 20
Page 18
Handling
Insert the threaded bolts so deeply that the upper edge of the
threaded bolt sticks out approx. 15 mm behind the upper edge of
the tiles.
Secure threaded bolts with a 90° turn.
Screw actuating rod into the tapped hole.
Set the screw-in depth flush with the upper edge of the tiles with the
help of the template supplied.
Screw on basic panel.
Flush plate Visign for Public 118 from 20
Page 19
Mount holding plates and basic panels.
Mount and screw flush plate tight.
Handling
3.3Commissioning
3.3.1Setting the flush
Set the flush volume on the drain valve of the cistern.
Large flush volume: approx. 6–9 litres
3.4
ErrorCauseRemedy
WC does not flushCistern is not yet completely fullWait until the cistern is sufficiently
Error, faults and remedy
No water in cistern, corner valve is
closed
full
Open corner valve
WC flush runs throughDirty seal in filling valveCheck seal, replace if necessary
Flush plate Visign for Public 119 from 20
Page 20
ErrorCauseRemedy
Dirty seal in drain valveCheck seal, replace if necessary
Handling
WC flush actuation does not workThe mechanism is not connected
to the bow
3.5Care and maintenance
3.5.1Maintenance tips
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the flush plate. Under no circumstances
should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse
the detergent thoroughly with clear water after the prescribed exposure
time. There should be no residue on the components.
3.6Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Hang the mechanism in the bow
Flush plate Visign for Public 120 from 20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.