Viega 8310.76 Instructions For Use Manual

Page 1
Filling valve set
Instructions for Use
for wall-mounted cisterns by various manufacturers Model Year built:
8310.76 from 04/2017
en_INT
Page 2
Filling valve set 2 from 12
Page 3

Table of contents

Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.2
Area of application 6 Product description 6
3 Handling 7
3.1
3.1.1
3.1.2
3.2
Assembly 7 Mounting the filling valve set 7 Cleaning / replacing the membrane valve 9 Disposal 12
Filling valve set 3 from 12
Page 4
About these instructions for use

1 About these instructions for use

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.

1.2 Labelling of notes

Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Filling valve set 4 from 12
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Filling valve set 5 from 12
Page 6

2 Product information

1
2
3
4
5
6

2.1 Area of application

The filling valve set is intended for filling a flush-mounted cistern.

2.2 Product description

Product information
Fig. 1: Filling valve set
1 filling valve 2 union nut 3 nipples 4 Clamp connector 5 cistern fastening (3-pc.) 6 spacer
Filling valve set 6 from 12
Page 7

3 Handling

3.1 Assembly

3.1.1 Mounting the filling valve set

Push the nipple through the union nut. Place the spacer on.
Handling
Mounting on the left side
Insert the group (consisting of union nut and spacer) in the filling valve.
Hand-tighten the union nut.
Push the filling valve with the nipple through the opening of the cis­tern and fasten it.
Mounting on the right side
Filling valve set 7 from 12
Page 8
Handling
Push the filling valve with the nipple through the opening of the cis­tern and fasten it.
Fasten the nipple from the outside at the cistern.
Connect the nipple with union nut / flexible hose or Cu pipe / clamp connector.
Filling valve set 8 from 12
Page 9

3.1.2 Cleaning / replacing the membrane valve

Dismantle the filling valve.
Fold up the catches on the cover.
Handling
Remove the cover upwards.
Filling valve set 9 from 12
Page 10
Bend up the holder for the float.
Slide the holder downwards.
Handling
Use snipe nose pliers to release the fixing rim by rotating through 45° in anti-clockwise direction.
Remove the closing piece.
Filling valve set 10 from 12
Page 11
Remove the membrane valve.
NOTICE! Do not dismantle the membrane valve into its compo­nents to avoid damage.
Handling
If necessary, clean the membrane valve by holding it under running water.
Mount the membrane valve, checking for correct seating.
Filling valve set 11 from 12
Page 12
Handling
Tighten the fixing rim by rotating through 45° in clockwise direction.
Re-mount the holder of the float on the closing piece.
3.2
Disposal
Mount the cover.
Mount the valve in the cistern, see
filling valve set“ on page 7
Check the function.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
.
Ä Chapter 3.1.1 „Mounting the
Filling valve set 12 from 12
Loading...