Trade mark rights exist for this document, further information can be
found at
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Consumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Viega Eco Plus sink basin element4 from 14
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Viega Eco Plus sink basin element5 from 14
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
Regulations from section: Fields of application / Mounting conditions
Scope / NoticeRegulations applicable in Ger-
suitable masonry wallsEN 1996-1-1
suitable concreted wallsDIN 1045
viega.com/standards
Product information
.
many
2.2Intended use
2.2.1Areas of use
suitable support profilesDIN 18183
Regulations from section: Sound protection
Scope / NoticeRegulations applicable in Ger-
many
Fulfilled noise protection requirements
Fulfilled noise protection requirements
Fulfilled noise protection requirements
The Viega Eco Plus sink basin element is suitable for mounting on
masonry wall constructions and support profiles pursuant to the regulations in section
Mounting conditions“ on page 6
Ä „Regulations from section: Fields of application /
DIN 4109
DIN 4109 (additional sheet 2)
VDI 4100 SSt I-SSt II
.
Viega Eco Plus sink basin element6 from 14
Page 7
2.3Product description
2
4
3
5
1
6
2.3.1Overview
Product information
Fig. 1: Components
1 - Viega Eco Plus element
2 - connections for wall plates
3 - mounting panel
4 - mounting bracket for drain elbow
5 - drain elbow
6 - adjustable feet
2.3.2Compatible components
The element is compatible with all common sink basins.
2.3.3
Sound protection
The sink basin element complies with the noise insulation requirements
specified in section
on page 6
Ä „Regulations from section: Sound protection“
.
Viega Eco Plus sink basin element7 from 14
Page 8
2.3.4Technical data
Product information
The product has the following technical data:
drain elbowDN 50
2.4Accessories
Required accessories
Hole diameter for fixing in wooden
frame construction
Construction height1300 mm
The fixing set model 8173 is required to secure.
11 mm
Viega Eco Plus sink basin element8 from 14
Page 9
3Handling
3.1Assembly information
3.1.1Mounting conditions
Suitable walls
The element is suitable for mounting on masonry wall constructions and
support profiles pursuant to the regulations in section
from section: Fields of application / Mounting conditions“ on page 6
The element may only be mounted on even wall surfaces.
Construction height
With the construction height, the marked height of the upper edge of
the finished floor must be observed.
Handling
Ä „Regulations
.
3.1.2Installation dimensions
Fig. 2: Dimensions
3.1.3Required tools
The following tools are required for mounting the sink basin element:
Viega Eco Plus sink basin element9 from 14
Page 10
3.2Assembly
X3
0-200
X1
X2
0
Ø10
560638_B2
13
3.2.1Mounting the element
Masonry wall
Handling
n drill with 10 mm drill bit
n ratchet with sockets: 13 mm / 17 mm
n fork or ring spanner: 13 mm / 17 mm
Masonry and concreted walls
You should use a support bracket (model 8165) when
mounting multiple sink basin elements with an interval of
> 490 mm. Observe the instructions for use of the support
bracket when mounting.
Determine and mark fixing points.
n X1: 390 mm (model 8180.73)
n X2: 440 mm (model 8173)
n X3: 1280 mm
Drill holes.
Mount the fixing set with the fork spanner (size 13).
Viega Eco Plus sink basin element10 from 14
Page 11
0-200
0
1000
17
0-200
0
X
17
0-200
0
X
Ø10
Handling
Align height of element.
Whilst doing so, observe the markings on the element.
Determine construction height in accordance with the on-site
marking of the upper edge of the finished floor.
INFO! The construction height must be determined exactly.
There are only limited possibilities available to remedy errors
made during this assembly step,
on page 9
.
Ä „Construction height“
Set height of the crossbeam.
The crossbeam aids the installation of the wall-mounted fitting.
Set the installation depth of the element with the fork spanner
(size 17).
Remove WC element and drill floor holes.
Viega Eco Plus sink basin element11 from 14
Page 12
13
click
50 - 100
0-200
0
Handling
Attach element to the floor using the fork spanner (size 13) and the
screws and dowels supplied.
Mount drain elbow in mounting bracket.
Secure with a bracket.
Set height of the drain elbow (50–100 mm).
Set connections for wall plates.
Observe the instructions of the fitting manufacturer.
Make water connections.
Double-clad element (2 x 12.5 mm).
Mounting in on-site support profile
The element can be inserted into the 50 mm and 75 mm support profiles.
Determine the fixing points.
Align element.
Mount drain elbow.
Set connections for wall plates.
Viega Eco Plus sink basin element12 from 14
Page 13
Ø10
13
90°
50
75
0-200
0
1000
0-200
0
X
Handling
If necessary, adjust the pre-mounted foot depth from 75 mm to
50 mm: Pull out foot and turn by 90°.
Attach element to the floor using the fork spanner (size 13) and the
screws and dowels supplied.
Determine construction height in accordance with the on-site
marking of the upper edge of the finished floor.
Align height of element.
Whilst doing so, observe the markings on the element.
INFO! The construction height must be determined exactly.
There are only limited possibilities available to remedy errors
made during this assembly step,
on page 9
.
Ä „Construction height“
Set height of the crossbeam.
The crossbeam aids the installation of the wall-mounted fitting.
Viega Eco Plus sink basin element13 from 14
Page 14
Screw element together laterally with the support profiles.
8x
Make water connections.
Double-clad element (2 x 12.5 mm).
Handling
3.3Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.