Viega 8133.3 Instructions For Use Manual

Page 1
Washbasin module
Instructions for Use
for barrier-free washbasins Model Year built:
8133.3 from 03/2009
en_INT
Page 2
Washbasin module 2 from 13
Page 3

Table of contents

Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.2
2.2.1
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.4
Standards and regulations 6 Intended use 6 Areas of use 6 Product description 7 Overview 7 Compatible components 7 Sound protection 7 Technical data 8 Accessories and spare parts 8
3 Handling 9
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.3
Assembly information 9 Mounting conditions 9 Installation dimensions 9 Required tools 9 Assembly 10 Mounting module 10 Rounding off jobs 13 Disposal 13
Washbasin module 3 from 13
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Drywall builder
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Washbasin module 4 from 13
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Washbasin module 5 from 13
Page 6

2 Product information

2.1 Standards and regulations

The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
Regulations from section: Fields of application / Mounting conditions
Scope / Notice Regulations applicable in Ger-
suitable masonry walls EN 1996-1-1
suitable concreted walls DIN 1045
viega.com/standards
Product information
.
many

2.2 Intended use

2.2.1 Areas of use

suitable support profiles DIN 18183
Regulations from section: Sound protection
Scope / Notice Regulations applicable in Ger-
many
Fulfilled noise protection require­ments
Fulfilled noise protection require­ments
Fulfilled noise protection require­ments
The Viega washbasin module is suitable for mounting on wall construc­tions pursuant to the regulations in section
Fields of application / Mounting conditions“ on page 6
for use in a Steptec pre-wall construction.
DIN 4109
DIN 4109 (additional sheet 2)
VDI 4100 SSt I-SSt II
Ä „Regulations from section:
and is intended
Washbasin module 6 from 13
Page 7

2.3 Product description

2.3.1 Overview

Product information
Fig. 1: Components and scope of delivery
1 - washbasin module 2 - threaded bolt 3 - connections for wall plates 4 - concealed siphon

2.3.2 Compatible components

The module is compatible with all common washbasin ceramics, even with larger projection (barrier-free).
2.3.3
Sound protection
The washbasin module complies with the noise insulation requirements specified in section
on page 6
Ä „Regulations from section: Sound protection“
.
Washbasin module 7 from 13
Page 8

2.3.4 Technical data

The product has the following technical data:
drain elbow DN 40 / 50
Rubber nipple DN 40 / 30

2.4 Accessories and spare parts

Required accessories
The fixing set model 8173 is required to secure.
Product information
For Keramag washbasin models
You require a concealed odour trap. Available models
n Model 5633.1 (chrome-plated cover plate) n Model 5633.2 (white cover plate)
The suitable drain for the following washbasin models must be ordered from Keramag.
Keramag wash­basin model
Keramag model No.
Paracelsus Vitalis Dejuna
521 323 521 323 521 423
Washbasin module 8 from 13
Page 9

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

Suitable walls
For this, observe the Steptec system instructions for use.
Construction height
With the construction height, the marked height of the upper edge of the finished floor must be observed.
Handling

3.1.2 Installation dimensions

Fig. 2: Dimensions
A - adjustable height

3.1.3 Required tools

The following tools are required for mounting the washbasin module:
Washbasin module 9 from 13
Page 10

3.2 Assembly

3.2.1 Mounting module

Mounting in Steptec
Securing module
Handling
n ratchet with sockets: 13 mm / 17 mm n fork or ring spanner: 17 mm / 19 mm n Phillips-tip screwdriver
The two vertical rails, which surround the module, must be open towards the module and be at an interval of 430 mm.
Secure the module onto the open Steptec rail with the slot nuts sup­plied:
Insert the slot nut into the opening of the module.
Push the slot nut in slightly. Turn by 90°.
The slot nut is secured in the Steptec rail.
ð
Washbasin module 10 from 13
Page 11
Align the height of the module. Tighten the slot nut with a ring spanner (SW 17).
Tighten the other slot nuts in the same way.
The module is secured on the rail framework.
ð
Handling
Set desired height of the module (X). When doing so, observe the upper edge of the finished floor.
Attach the concealed siphon with the screws attached.
Washbasin module 11 from 13
Page 12
Handling
Set height of fitting connection panel. To do this, loosen the lateral screws and choose the desired height. Re-tighten screws.
Remove the site protection. Check pipe position and, if necessary, set the required sizes. Subsequent adjustment is possible. Replace the site protection.
Attach bracket for threaded bolts: Insert bracket horizontally and turn clockwise by 90°. The distance between the brackets may only be a maximum of
390 mm. Screw in threaded bolt and tighten with a ring spanner (SW 17).
Set the connections for wall plates. The interval between the con­nections bolts can be set to 226 or 306 mm.
Washbasin module 12 from 13
Page 13
Fig. 3: Installation dimensions, concealed siphon with ceramic

3.2.2 Rounding off jobs

Handling
Observe highest and lowest sizes. Observe the ceramic manufacturer's instructions for additional
sizes.
3.3
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge. Grout the abutting edges and joints with a suitable filler. Observe the instruction manual for the cladding panels for more
information.
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Washbasin module 13 from 13