Trade mark rights exist for this document, further information can be
found at
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Drywall builder
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Washbasin module4 from 13
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Washbasin module5 from 13
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
Regulations from section: Fields of application / Mounting conditions
Scope / NoticeRegulations applicable in Ger-
suitable masonry wallsEN 1996-1-1
suitable concreted wallsDIN 1045
viega.com/standards
Product information
.
many
2.2Intended use
2.2.1Areas of use
suitable support profilesDIN 18183
Regulations from section: Sound protection
Scope / NoticeRegulations applicable in Ger-
many
Fulfilled noise protection requirements
Fulfilled noise protection requirements
Fulfilled noise protection requirements
The Viega washbasin module is suitable for mounting on wall constructions pursuant to the regulations in section
Fields of application / Mounting conditions“ on page 6
The module is compatible with all common washbasin ceramics, even
with larger projection (barrier-free).
2.3.3
Sound protection
The washbasin module complies with the noise insulation requirements
specified in section
on page 6
Ä „Regulations from section: Sound protection“
.
Washbasin module7 from 13
Page 8
2.3.4Technical data
The product has the following technical data:
drain elbowDN 40 / 50
Rubber nippleDN 40 / 30
2.4Accessories and spare parts
Required accessories
The fixing set model 8173 is required to secure.
Product information
For Keramag washbasin models
You require a concealed odour trap.
Available models
n Model 5633.1 (chrome-plated cover plate)
n Model 5633.2 (white cover plate)
The suitable drain for the following washbasin models must be ordered
from Keramag.
Keramag washbasin model
Keramag model
No.
ParacelsusVitalisDejuna
521 323521 323521 423
Washbasin module8 from 13
Page 9
3Handling
3.1Assembly information
3.1.1Mounting conditions
Suitable walls
For this, observe the Steptec system instructions for use.
Construction height
With the construction height, the marked height of the upper edge of
the finished floor must be observed.
Handling
3.1.2Installation dimensions
Fig. 2: Dimensions
A - adjustable height
3.1.3Required tools
The following tools are required for mounting the washbasin module:
Washbasin module9 from 13
Page 10
3.2Assembly
3.2.1Mounting module
Mounting in Steptec
Securing module
Handling
n ratchet with sockets: 13 mm / 17 mm
n fork or ring spanner: 17 mm / 19 mm
n Phillips-tip screwdriver
The two vertical rails, which surround the module, must be
open towards the module and be at an interval of 430 mm.
Secure the module onto the open Steptec rail with the slot nuts supplied:
Insert the slot nut into the opening of the module.
Push the slot nut in slightly.
Turn by 90°.
The slot nut is secured in the Steptec rail.
ð
Washbasin module10 from 13
Page 11
Align the height of the module.
Tighten the slot nut with a ring spanner (SW 17).
Tighten the other slot nuts in the same way.
The module is secured on the rail framework.
ð
Handling
Set desired height of the module (X). When doing so, observe the
upper edge of the finished floor.
Attach the concealed siphon with the screws attached.
Washbasin module11 from 13
Page 12
Handling
Set height of fitting connection panel.
To do this, loosen the lateral screws and choose the desired height.
Re-tighten screws.
Remove the site protection.
Check pipe position and, if necessary, set the required sizes.
Subsequent adjustment is possible.
Replace the site protection.
Attach bracket for threaded bolts:
Insert bracket horizontally and turn clockwise by 90°.
The distance between the brackets may only be a maximum of
390 mm.
Screw in threaded bolt and tighten with a ring spanner (SW 17).
Set the connections for wall plates. The interval between the connections bolts can be set to 226 or 306 mm.
Washbasin module12 from 13
Page 13
Fig. 3: Installation dimensions, concealed
siphon with ceramic
3.2.2Rounding off jobs
Handling
Observe highest and lowest sizes.
Observe the ceramic manufacturer's instructions for additional
sizes.
3.3
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide
Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge.
Grout the abutting edges and joints with a suitable filler.
Observe the instruction manual for the cladding panels for more
information.
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Washbasin module13 from 13