Viega 8127.3 Instructions For Use Manual

Page 1
Urinal module
Instructions for Use
for "Joly" and "Visit" (Keramag) urinal, connection of the Visign equipment set (manual and touchless flush actuation)
Model Year built:
8127.3 from 03/2009
en_INT
Page 2
Urinal module 2 from 15
Page 3
1 About these instructions for use 4
Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.2
2.2.1
2.3
2.3.1
2.3.2
2.3.3
2.3.4
Standards and regulations 6 Intended use 6 Areas of use 6 Product description 7 Overview 7 Compatible components 7 Sound protection 8 Technical data 8
3 Handling 9
3.1
3.1.1
3.1.2
3.2
3.2.1
3.2.2
3.3
Assembly information 9 Mounting conditions 9 Required tools 9 Assembly 9 Mounting module 9 Rounding off jobs 15 Disposal 15
Urinal module 3 from 15
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Urinal module 4 from 15
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Urinal module 5 from 15
Page 6

2 Product information

2.1 Standards and regulations

The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
Regulations from section: Sound protection
Scope / Notice Regulations applicable in Ger-
viega.com/standards
Product information
.
many

2.2 Intended use

2.2.1 Areas of use

Fulfilled noise protection require­ments
Fulfilled noise protection require­ments
Fulfilled noise protection require­ments
The urinal module is designed for mounting in a Steptec pre-wall con­struction.
DIN 4109
DIN 4109 (additional sheet 2)
VDI 4100 SSt I-SSt II
Urinal module 6 from 15
Page 7

2.3 Product description

2.3.1 Overview

Product information
Fig. 1: Components
1 - urinal installation set 2 - suction moulded piece 3 - connection for Keramag "Joly" and "Visit"

2.3.2 Compatible components

The urinal module is compatible with the urinals "Joly" and "Visit" by Keramag.
Compatible flush plates
Product
Visign for Style Flush plate Visign for
Name Model
8315.2
Style 10
Flush plate Visign for
8331.2
Style 11
Flush plate Visign for
8332.2
Style 12
Urinal module 7 from 15
Page 8
Product Name Model
Product information
Flush plate Visign for Style 13
Flush plate Visign for Style 14
Visign for More Flush plate Visign for
More 100
Flush plate Visign for More 102
Flush plate Visign for More 103
Flush plate Visign for More 104
Visign for Public Flush plate Visign for
Public
Remote actuation Visign for Public
Remote actuation Visign for Public
Cover plate Visign for Public
8333.2
8334.2
8352.2
8353.2
8355.2
8354.2
8326.2
8326.55
8326.65
8326.7

2.3.3 Sound protection

2.3.4 Technical data

The urinal module complies with the noise insulation requirements specified in section
on page 6
The product has the following technical data:
drain elbow
Fitting connection Rp ½
Maximum height of urinal inlet from upper edge of the finished floor
.
Ä „Regulations from section: Sound protection“
DN 50
n with basic element construc-
tion height 1130 = 880 mm
n with basic element construc-
tion height 1370 = 1120 mm
Urinal module 8 from 15
Page 9

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

Construction height
With the construction height, the marked height of the upper edge of the finished floor must be observed.
Actuation
The actuation takes place via manual flush actuation, connection of the Visign equipment set.
Handling

3.1.2 Required tools

3.2 Assembly

3.2.1 Mounting module

Mounting in Steptec
Securing module
The following tools are required for mounting the urinal module:
n fork or ring spanner: 17 mm / 19 mm n Phillips-tip screwdriver
The two vertical rails, which surround the module, must be open towards the module and be at an interval of 430 mm.
Secure the module onto the open Steptec rail with the slot nuts sup­plied:
Insert the slot nut into the opening of the module.
Urinal module 9 from 15
Page 10
Push the slot nut in slightly. Turn by 90°.
The slot nut is secured in the Steptec rail.
ð
Align the height of the module. Tighten the slot nut with a ring spanner (SW 17).
Handling
Tighten the other slot nuts in the same way.
The module is secured on the rail framework.
ð
Set desired height for the bracket of the drain elbow (X). When doing so, observe the upper edge of the finished floor.
Urinal module 10 from 15
Page 11
Make water connection.
Check height settings. In addition, observe the following details.
Handling
Keramag 'Joly'
Urinal module 11 from 15
Page 12
Handling
A - The size results from
Urinal module 12 from 15
Page 13
Handling
Keramag 'Visit'
A - The size results from
Urinal module 13 from 15
Page 14
Handling
A - The size results from
Urinal module 14 from 15
Page 15
Handling

3.2.2 Rounding off jobs

3.3
Disposal
A - The size results from
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge. Grout the abutting edges and joints with a suitable filler. Observe the instruction manual for the cladding panels for more
information.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Urinal module 15 from 15
Loading...