1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Universal bracket4 from 11
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Universal bracket5 from 11
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
Regulations from section: Fields of application / Mounting conditions
Scope / NoticeRegulations applicable in Ger-
suitable masonry wallsEN 1996-1-1
suitable concreted wallsDIN 1045
viega.com/standards
Product information
.
many
2.2Intended use
2.2.1Areas of use
Regulations from section: Sound protection
Scope / NoticeRegulations applicable in Ger-
many
Fulfilled noise protection requirements
Fulfilled noise protection requirements
Fulfilled noise protection requirements
The model is suitable for mounting on wall constructions pursuant to the
regulations in section
The model complies with the noise insulation requirements specified in
section
Ä „Regulations from section: Sound protection“ on page 6
.
Universal bracket7 from 11
Page 8
3Handling
3.1Assembly information
3.1.1Mounting conditions
Construction height
With the construction height, the marked height of the upper edge of
the finished floor must be observed.
3.1.2Installation dimensions
Handling
Fig. 2: Dimensions
3.1.3Required tools
The following tools are required for mounting:
n
fork or ring spanner: 17 mm / 19 mm
Universal bracket8 from 11
Page 9
3.2Assembly
3.2.1Mounting module
Mounting in Steptec
Handling
The two vertical rails, which surround the module, must be
open towards the module and be at an interval of 430 mm.
Secure the element onto the open Steptec rail with the slot nuts
supplied:
Insert the slot nut into the opening of the module.
Push the slot nut in slightly.
Turn by 90°.
The slot nut is secured in the Steptec rail.
ð
Set the height.
Tighten the slot nut with a ring spanner (SW 17).
Universal bracket9 from 11
Page 10
Handling
Tighten the other slot nuts in the same way.
The module is secured on the rail framework.
ð
Check height and width settings.
Check settings.
When doing so, also observe the equipment manufacturer's instruc-
tions.
Make sure that the fixing ends flush with the rail framework. The
fixing may extend for a maximum of 1.5 mm beyond the rail framework.
Set depth settings.
The depth of the bracket can be set to 70-155 mm.
Carry out before cladding of the installation and fixing of the building
project.
3.2.2Rounding off jobs
Universal bracket10 from 11
Page 11
3.3Disposal
Handling
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide
Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge.
Grout the abutting edges and joints with a suitable filler.
Observe the instruction manual for the cladding panels for more
information.
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Universal bracket11 from 11