Trade mark rights exist for this document; for further information, go to
viega.com/legal
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
cover plate4 from 15
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
cover plate5 from 15
Page 6
2Product information
2.1Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
Regulations from section: Preparing mounting
Scope / NoticeRegulations applicable in Ger-
Electrical installationVDE 0100
viega.com/standards
Product information
.
many
2.2Intended use
2.2.1Areas of use
This cover plate is only suitable for the Viega Eco Plus universal shower
WC element (model 8161.20).
The cover plate can only be used in combination with the following
shower WC models:
n
Geberit AquaClean 8000 WC complete system (article number
146.182.xx.x)
n Geberit Aqua Clean 8000 plus WC complete system (article number
180.100.xx.x)
n Geberit AquaClean Tuma Comfort WC top (article number
146.270.xx.x)
n Toto Neorest AC (article number TCF996WG#NW1)
n Toto Neorest EW (article number TCF994WG#NW1)
cover plate6 from 15
Page 7
2.3Product description
12
4
3
5
6
7
2.3.1Overview
Product information
Fig. 1: Components cover plate model 8040.18
1cover frame
2seal
3cover plate
4closing cap
5flexible hose ½ inch
6ball valve ½ inch
7mounting bracket for the earthed wall socket
cover plate7 from 15
Page 8
3Handling
3.1Assembly information
3.1.1Installation dimensions
Handling
Fig. 2: Dimensions cover plate model 8040.18
3.1.2Required tools
The following tools are required for mounting:
n
fork or ring spanner: 17 mm / 19 mm
n flat-blade screwdriver
n Spirit level
n Knife (cutter)
n handsaw
cover plate8 from 15
Page 9
3.2Assembly
17
19
3.2.1Preparing mounting
Handling
The locating surface for the cover plate must be mounted
flush with the finished wall surface.
Close water supply pipe to the Viega Eco Plus Universal shower WC
element.
Remove ½ inch plug.
Seal ½ inch flexible hose and then screw into the T-piece.
cover plate9 from 15
Page 10
Screw the ½ inch ball valve onto the flexible hose.
INFO! The earthing contact is not included in the scope of
delivery. Mounting bracket for the earthing socket. We recommend using an earthing socket with a lid.
Handling
Connect both parts of the mounting bracket for the earthed wall
socket with the screws supplied.
Hook the mounting bracket for the earthed wall socket behind the
right-hand fixing bolt for the shower WC and secure with a nut.
DANGER! Risk of electrocution
– Disconnect the electrical connection to the Viega Eco Plus
Universal shower WC from the mains.
– Installation only by companies specialising in electrical work
in compliance with the valid national regulations, see
ulations from section: Preparing mounting“ on page 6
Ä „Reg-
.
Lead the electrical connection for the shower WC into the junction
box.
DANGER! Risk of electrocution
– Disconnect the electrical connection to the Viega Eco Plus
Universal shower WC from the mains.
– Installation only by companies specialising in electrical work
in compliance with the valid national regulations, see
ulations from section: Preparing mounting“ on page 6
Ä „Reg-
.
Connect the earthing socket from the junction box.
cover plate10 from 15
Page 11
Loosen the four nuts on the element (size 17).
17
17
17
Loosen the four front nuts on the sides of the locating surface.
Align all four points flush with the finished wall surface by
unscrewing and screwing the threaded screws.
Check the alignment with spirit level.
Handling
Tighten the rear nuts at all four points (size 17), in the process,
secure the threaded screws with a slotted screwdriver.
Tighten the front nuts at all four points (size 17).
Check to ensure they are flush.
cover plate11 from 15
Page 12
19
Handling
Unscrew the threaded rods for the fixing of the WC element to the
required size and counter with nuts (size 19).
cover plate12 from 15
Page 13
3.2.2Mounting the cover plate
Handling
Insert the seal on the front into the cover frame.
Apply the silicone seal to the rear of the cover frame.
Align the cover frame and attach it to the element by the supplied
Phillips-head screws.
cover plate13 from 15
Page 14
Handling
Place the cover plate on the element.
Lead the flexible hose through the left-hand notch in the cover plate.
Insert the earthing plug of the shower WC through the right-hand
opening of the cover plate and into the earthing socket.
cover plate14 from 15
Page 15
3.2.3Mounting WC ceramic
Handling
Cut flushing and drain pipe to length.
Insert the closing cap into the right-hand opening of the cover plate.
Lead the cable of the earthing plug through the gap of the closing
cap.
Cut the sound insulation panel to size.
NOTICE! Do not use the cover plate as a support!
Mount sound insulation panel and shower WC ceramic.
Mount shower WC ceramic according to the manufacturer's instruc-
tions. Use the connecting material supplied for the water and electrical connection.
Open the water supply pipe to the Viega Eco Plus Universal shower
WC element.
Open the ball valve of the shower WC / shower WC top.
Connect the power supply to the concealed socket of the shower
WC / shower WC top.
Align and fix the shower WC ceramic.
Seal the gap between WC ceramic and cover plate with silicone.
3.3
cover plate15 from 15
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.