for water inlet through the overflow unit
ModelYear built:
6161.52from 06/2015
en_INT
Page 2
Multiplex Trio drain/overflow functional unit2 from 20
Page 3
Table of contents
1About these instructions for use4
Table of contents
1.1
1.2
1.3
Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use6
Areas of use6
Product description6
Overview6
Technical data7
Accessories8
3Handling11
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.3
3.4
3.5
Assembly information11
Mounting conditions11
Installation dimensions12
Required tools and materials12
Assembly12
Mounting overflow12
Mounting the drain14
Connecting overflow and drain14
Connecting the wastewater system15
Connecting the inlet16
Mounting equipment set17
Leakage test18
Demounting rotatable rosette18
Control19
Maintenance20
Disposal20
Multiplex Trio drain/overflow functional unit3 from 20
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document, further information can be
found at
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Operators
n Consumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
viega.com/legal
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex Trio drain/overflow functional unit4 from 20
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Multiplex Trio drain/overflow functional unit5 from 20
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
NOTICE!
Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following
liquids:
– Liquids with a pH-value higher than 4
– typical household water with a maximum temperature of
95 °C
Product information
2.2
Product description
2.2.1Overview
The Multiplex Trio drain°/overflow is a combined inlet, drain and overflow with odour trap for bathtubs with a 52 mm drain hole. The inlet
flows through the overflow opening.
The drain / overflow is suitable for standard bathtubs with the drain on
the head end.
Detailed information regarding all bathtub models and the corresponding Viega drains / overflows can be found in the catalogue or on
the Internet.
An equipment set with rotatable rosette and valve cone must be purchased separately.
The following components are included in the scope of delivery of the
Multiplex Trio drain / overflow:
Multiplex Trio drain/overflow functional unit6 from 20
Page 7
1
2
3
4657811 10127659
1314 15161718
Product information
2.2.2Technical data
Fig. 1: Component overview
1 - fixing screw
2 - valve top
3 - double seal
4 - drain elbow
5 - union nut
6 - sliding ring
7 - seal
8 - odour trap
9 - overflow pipe
10 - Bowden cable
11 - sleeve
12 - inlet adapter
13 - overflow unit
14 - profile seal
15 - additional seal (for steel bathtubs)
16 - supply flange
17 - fixing screw
18 - mounting aid
Drainage capacity (at an accumu-
0.87 l/s
lation height of 300 mm)
Overflow capacity (at an accumu-
0.63 l/s
lation height of 60 mm)
Multiplex Trio drain/overflow functional unit7 from 20
Page 8
Product information
2.3Accessories
Inlet capacity (at 0.25 MPa
(2.5 bar))
Diameter of bathtub drain hole52 mm
DN (nominal diameter) drain support
Length of Bowden cable560 mm
Length100–260 mm
Height180–400 mm
Dimensions and installation depth
20 l/min
40 / 50 mm
Ä Chapter 3.1.2 „Installation
dimensions“ on page 12
Water head seal50 mm
The accessories shown here are not included in the scope
of delivery. If required, it must be purchased separately.
Required accessories
pipe interrupter
To ensure that no bath water flows back into the drinking water system,
a pipe interrupter must be installed, e. g. the connection set with concealed pipe interrupter DN 20 in acc. DIN EN 1717, model 6161.86.
Equipment sets
As this product is a the functional unit (without rotatable rosette and
valve cone), you require an equipment set to enable complete mounting.
Equipment sets contain a rotatable rosette for the overflow and a valve
cone for the drain of the functional unit. You can find a choice of different models in various designs in the catalogue.
Multiplex Trio drain/overflow functional unit8 from 20
Page 9
Equipment set Multiplex Trio Visign MT3: Model 6161.13
Equipment set Multiplex Trio Visign MT5: Model 6161.01
Product information
Optional accessories
Equipment set with water level increase
The water level of the overflow can be increased by 5 cm with the
equipment set. The equipment set contains a rotatable rosette, a fixing
flange, a valve cone, a fixing screw, a flange cover and a mounting aid
for the drain of the functional unit.
Equipment set Multiplex Trio Visign MT9: Model 6170.0
Multiplex Trio drain/overflow functional unit9 from 20
Page 10
Product information
Multiplex extension set
It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is
available for such cases.
Multiplex Trio drain/overflow functional unit10 from 20
Page 11
3Handling
3.1Assembly information
3.1.1Mounting conditions
The following requirements exist for the mounting of the drain / overflow:
n The bathtub is installed.
n The drainage line is installed all the way to the bathtub.
n The underside of the bathtub is accessible.
Pipe interrupter
Backflow situation: If a negative pressure situation should occur when
the bathtub is filled, there is a possibility that bath water may flow back
into the drinking water system.
Handling
To ensure that no bath water flows back into the drinking water system,
a pipe interrupter must be installed in the pipeline between the shut-off
fitting and the bathtub inlet.
The following schematic diagram shows what this should look like:
Fig. 2: Mounting scheme with pipe interrupter
It is important that the pipe interrupter is mounted at least 150 mm
above the top edge of the bathtub.
Observe the local standards and regulations.
The pipe interrupter is not included in the scope of delivery and must be
ordered separately. Observe the instructions for use of the pipe interrupter.
Multiplex Trio drain/overflow functional unit11 from 20
Page 12
3.1.2Installation dimensions
Handling
Fig. 3: Dimensional drawing
The following values are valid for L (length) and H (height):
L = 100–260
H = 180–400
3.1.3Required tools and materials
Tool
The following tools are required for mounting:
n fine-toothed saw
n mounting aid (included in the scope of delivery)
n spanner (SW 26)
Material
The following material must be purchased separately and must be available during mounting:
n pipe interrupter (e. g. the pipe interrupter set for connection of the
inlet)
n Connection set for the connection of the inlet (e. g. the pipe inter-
rupter set)
n equipment set
3.2Assembly
3.2.1Mounting overflow
Proceed as follows to the mounting of the overflow:
Multiplex Trio drain/overflow functional unit12 from 20
Page 13
Handling
Fit profile seal in the overflow unit.
If the wall thickness a in steel bathtubs is less than 3 mm, insert
addition seal for steel bathtubs between profile seal and bathtub.
Push the rubber sleeve onto the overflow unit pipe until the lower
edge is flush with the edge of the overflow pipe.
Fit inlet flange into the overflow unit.
Screw in fixing screw and tighten hand tight.
On the hexagon of the mounting aid, there is a groove, which must
be positioned on the lip of the fixing screw.
Multiplex Trio drain/overflow functional unit13 from 20
Page 14
3.2.2Mounting the drain
Handling
Proceed as follows to mount the drain:
Place the double seal onto the drain unit in such a way that the
recess is positioned over the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below.
Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
INFO! The cross-shaped structures of the drain units and the
valve top must be positioned parallel on top of each other to
ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using the
mounting aid.
3.2.3Connecting overflow and drain
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Multiplex Trio drain/overflow functional unit14 from 20
Page 15
Handling
Requirements:
n The overflow is mounted in the overflow opening.
n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.
Hold the pipe of the overflow unit parallel to the overflow pipe and
mark the positions where the drain and the overflow should be connected.
Maintain an insertion depth of at least 15 mm!
Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve.
Maintain an insertion depth of at least 15 mm!
Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow.
Screw the union nut on the drain unit.
3.2.4Connecting the wastewater system
Proceed as follows to connect the drain/overflow to the wastewater
system:
Multiplex Trio drain/overflow functional unit15 from 20
Page 16
Requirements:
n The overflow and drain units are installed on the bathtub.
n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain
elbow.
Handling
Push union nut, sliding ring and seal onto the drain elbow.
Screw the union nut on the drain unit.
Align the odour trap in such a way that the drain elbow can be connected to the wastewater pipe.
Turn the drain at the joints until the required position has been
reached.
Push wastewater pipe in the drain elbow.
3.2.5Connecting the inlet
Proceed as follows to connect the water inlet to the overflow unit:
Requirements:
n A connection set (e. g. the pipe interrupter set) is available.
n A pipe interrupter is installed in the supply pipeline.
n Overflow and drain are mounted.
Multiplex Trio drain/overflow functional unit16 from 20
Page 17
n Overflow and drain are connected.
n The connection to the waste water system has been made.
Push union nut and clamping ring (parts of the connection set) onto
the water-carrying pipe.
Push the narrow end of the screw fitting (part of the connection set)
into the pipe as far as it will go.
Push the free end of the screw fitting into the inlet adapter.
Screw in the pipe tight with the union nut onto the inlet adapter.
Insert the inlet adapter into the overflow unit.
Handling
3.2.6Mounting equipment set
To avoid damage to the rosette and valve cone, only mount the equipment set after finishing all other work on the building site. Proceed as
follows:
The inlet adapter must click into place in the overflow unit with a
noticeable clicking sound.
The equipment set is not included in the scope of delivery
and must be purchased separately.
Place the flange cover onto the supply flange with the straight side
facing downwards and affix.
Align and fit rotatable rosette.
Fit valve cone.
Multiplex Trio drain/overflow functional unit17 from 20
Page 18
Handling
Turn rotatable rosette to check function and alignment.
The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve
cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter
with union nut.
3.2.7Leakage test
The leakage test is only carried out as a visual inspection.
Check the points marked in the following drawing with particular care:
Check drain fitting for visible leaks.
3.2.8Demounting rotatable rosette
If the rotatable rosette on the overflow is to be removed, proceed as follows to prevent damaging the rosette and the flange cover:
Remove the rotatable rosette in the axial direction.
Multiplex Trio drain/overflow functional unit18 from 20
Page 19
3.3Control
Handling
Remove the flange cover at the marked points.
Remove flange cover.
The drain / overflow are controlled via rotatable rosette on the overflow.
Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
The drain closes itself.
ð
Turn rotatable rosette to the right.
The drain opens itself.
ð
Setting the water inlet direction
There is a regulator for the water jet on the underside of the rotatable
rosette. Proceed as follows to adjust the water jet:
Multiplex Trio drain/overflow functional unit19 from 20
Page 20
3.4Maintenance
Handling
Push the flow control backwards or forwards with your finger. The
water flows closer or further away from the side of the bathtub
depending on the direction set.
NOTICE!
Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated
surfaces and therefore may not be used:
3.5
– scouring agent
– abrasive sponges
– lime, plaster or cement dissolver
– solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the rotatable rosette and valve cone. Under
no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be
removed using typical household cleaner. It should be noted that the
cleaning agent should be rinsed off after the prescribed soaking time.
There should be no residue on the components.
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Multiplex Trio drain/overflow functional unit20 from 20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.