Viega 6161.52 Instructions For Use Manual

Page 1
Multiplex Trio drain/overflow functional unit
Instructions for Use
for water inlet through the overflow unit Model Year built:
6161.52 from 06/2015
en_INT
Page 2
Multiplex Trio drain/overflow functional unit 2 from 20
Page 3

Table of contents

Table of contents
1.1
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.1.1
2.2
2.2.1
2.2.2
2.3
Intended use 6 Areas of use 6 Product description 6 Overview 6 Technical data 7 Accessories 8
3 Handling 11
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.3
3.4
3.5
Assembly information 11 Mounting conditions 11 Installation dimensions 12 Required tools and materials 12 Assembly 12 Mounting overflow 12 Mounting the drain 14 Connecting overflow and drain 14 Connecting the wastewater system 15 Connecting the inlet 16 Mounting equipment set 17 Leakage test 18 Demounting rotatable rosette 18 Control 19 Maintenance 20 Disposal 20
Multiplex Trio drain/overflow functional unit 3 from 20
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Operators n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Multiplex Trio drain/overflow functional unit 4 from 20
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, stand­ards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
About these instructions for use
Multiplex Trio drain/overflow functional unit 5 from 20
Page 6

2 Product information

2.1 Intended use

2.1.1 Areas of use

NOTICE! Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following liquids:
– Liquids with a pH-value higher than 4 – typical household water with a maximum temperature of
95 °C
Product information
2.2
Product description

2.2.1 Overview

The Multiplex Trio drain°/overflow is a combined inlet, drain and over­flow with odour trap for bathtubs with a 52 mm drain hole. The inlet flows through the overflow opening.
The drain / overflow is suitable for standard bathtubs with the drain on the head end.
Detailed information regarding all bathtub models and the corre­sponding Viega drains / overflows can be found in the catalogue or on the Internet.
An equipment set with rotatable rosette and valve cone must be pur­chased separately.
The following components are included in the scope of delivery of the Multiplex Trio drain / overflow:
Multiplex Trio drain/overflow functional unit 6 from 20
Page 7
1 2
3
46 57811 1012 7659
13 14 15 16 17 18
Product information

2.2.2 Technical data

Fig. 1: Component overview
1 - fixing screw 2 - valve top 3 - double seal 4 - drain elbow 5 - union nut 6 - sliding ring 7 - seal 8 - odour trap 9 - overflow pipe 10 - Bowden cable 11 - sleeve 12 - inlet adapter 13 - overflow unit 14 - profile seal 15 - additional seal (for steel bathtubs) 16 - supply flange 17 - fixing screw 18 - mounting aid
Drainage capacity (at an accumu-
0.87 l/s
lation height of 300 mm)
Overflow capacity (at an accumu-
0.63 l/s
lation height of 60 mm)
Multiplex Trio drain/overflow functional unit 7 from 20
Page 8
Product information

2.3 Accessories

Inlet capacity (at 0.25 MPa (2.5 bar))
Diameter of bathtub drain hole 52 mm
DN (nominal diameter) drain sup­port
Length of Bowden cable 560 mm
Length 100–260 mm
Height 180–400 mm
Dimensions and installation depth
20 l/min
40 / 50 mm
Ä Chapter 3.1.2 „Installation dimensions“ on page 12
Water head seal 50 mm
The accessories shown here are not included in the scope of delivery. If required, it must be purchased separately.
Required accessories
pipe interrupter To ensure that no bath water flows back into the drinking water system,
a pipe interrupter must be installed, e. g. the connection set with con­cealed pipe interrupter DN 20 in acc. DIN EN 1717, model 6161.86.
Equipment sets As this product is a the functional unit (without rotatable rosette and
valve cone), you require an equipment set to enable complete mounting. Equipment sets contain a rotatable rosette for the overflow and a valve cone for the drain of the functional unit. You can find a choice of dif­ferent models in various designs in the catalogue.
Multiplex Trio drain/overflow functional unit 8 from 20
Page 9
Equipment set Multiplex Trio Visign MT3: Model 6161.13
Equipment set Multiplex Trio Visign MT5: Model 6161.01
Product information
Optional accessories
Equipment set with water level increase The water level of the overflow can be increased by 5 cm with the
equipment set. The equipment set contains a rotatable rosette, a fixing flange, a valve cone, a fixing screw, a flange cover and a mounting aid for the drain of the functional unit.
Equipment set Multiplex Trio Visign MT9: Model 6170.0
Multiplex Trio drain/overflow functional unit 9 from 20
Page 10
Product information
Multiplex extension set It is possible to extend the odour trap below the bathtub in the case of
bathtubs with a very thick floor. The extension set, model 6161.7, is available for such cases.
Multiplex Trio drain/overflow functional unit 10 from 20
Page 11

3 Handling

3.1 Assembly information

3.1.1 Mounting conditions

The following requirements exist for the mounting of the drain / over­flow:
n The bathtub is installed. n The drainage line is installed all the way to the bathtub. n The underside of the bathtub is accessible.
Pipe interrupter
Backflow situation: If a negative pressure situation should occur when the bathtub is filled, there is a possibility that bath water may flow back into the drinking water system.
Handling
To ensure that no bath water flows back into the drinking water system, a pipe interrupter must be installed in the pipeline between the shut-off fitting and the bathtub inlet.
The following schematic diagram shows what this should look like:
Fig. 2: Mounting scheme with pipe interrupter
It is important that the pipe interrupter is mounted at least 150 mm above the top edge of the bathtub.
Observe the local standards and regulations. The pipe interrupter is not included in the scope of delivery and must be
ordered separately. Observe the instructions for use of the pipe inter­rupter.
Multiplex Trio drain/overflow functional unit 11 from 20
Page 12

3.1.2 Installation dimensions

Handling
Fig. 3: Dimensional drawing
The following values are valid for L (length) and H (height): L = 100–260
H = 180–400

3.1.3 Required tools and materials

Tool
The following tools are required for mounting:
n fine-toothed saw n mounting aid (included in the scope of delivery) n spanner (SW 26)
Material
The following material must be purchased separately and must be avail­able during mounting:
n pipe interrupter (e. g. the pipe interrupter set for connection of the
inlet)
n Connection set for the connection of the inlet (e. g. the pipe inter-
rupter set)
n equipment set

3.2 Assembly

3.2.1 Mounting overflow

Proceed as follows to the mounting of the overflow:
Multiplex Trio drain/overflow functional unit 12 from 20
Page 13
Handling
Fit profile seal in the overflow unit. If the wall thickness a in steel bathtubs is less than 3 mm, insert
addition seal for steel bathtubs between profile seal and bathtub.
Push the rubber sleeve onto the overflow unit pipe until the lower edge is flush with the edge of the overflow pipe.
Fit inlet flange into the overflow unit.
Screw in fixing screw and tighten hand tight. On the hexagon of the mounting aid, there is a groove, which must
be positioned on the lip of the fixing screw.
Multiplex Trio drain/overflow functional unit 13 from 20
Page 14

3.2.2 Mounting the drain

Handling
Proceed as follows to mount the drain:
Place the double seal onto the drain unit in such a way that the recess is positioned over the connecting pipe.
Pull the edge of the double seal over the edge of the drain.
Hold the drain with double seal onto the drain opening from below. Pull the upper part of the double seal through the drain hole.
Fit the valve top in the double seal.
INFO! The cross-shaped structures of the drain units and the valve top must be positioned parallel on top of each other to ensure the full drainage capacity.
Place the fixing screw in the drain unit and tighten using the mounting aid.

3.2.3 Connecting overflow and drain

After the overflow and the drain have been mounted, you must connect them both using the overflow pipe. Proceed as follows:
Multiplex Trio drain/overflow functional unit 14 from 20
Page 15
Handling
Requirements:
n The overflow is mounted in the overflow opening. n The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far enough into each other become leaky. For this reason, maintain a minimum insertion depth of 15 mm for every connection.
Hold the pipe of the overflow unit parallel to the overflow pipe and mark the positions where the drain and the overflow should be con­nected.
Maintain an insertion depth of at least 15 mm! Cut the overflow pipe to the marked length and, if necessary,
deburr.
Push the top end of the overflow pipe into the rubber sleeve. Maintain an insertion depth of at least 15 mm! Push the union nut, sliding ring and seal onto the bottom end of the
drain elbow. Screw the union nut on the drain unit.

3.2.4 Connecting the wastewater system

Proceed as follows to connect the drain/overflow to the wastewater system:
Multiplex Trio drain/overflow functional unit 15 from 20
Page 16
Requirements:
n The overflow and drain units are installed on the bathtub. n The connection between overflow and drain has been made.
If the wastewater pipe only has a diameter of 40 mm, cut off drain elbow.
Handling
Push union nut, sliding ring and seal onto the drain elbow. Screw the union nut on the drain unit.
Align the odour trap in such a way that the drain elbow can be con­nected to the wastewater pipe.
Turn the drain at the joints until the required position has been reached.
Push wastewater pipe in the drain elbow.

3.2.5 Connecting the inlet

Proceed as follows to connect the water inlet to the overflow unit:
Requirements:
n A connection set (e. g. the pipe interrupter set) is available. n A pipe interrupter is installed in the supply pipeline. n Overflow and drain are mounted.
Multiplex Trio drain/overflow functional unit 16 from 20
Page 17
n Overflow and drain are connected. n The connection to the waste water system has been made.
Push union nut and clamping ring (parts of the connection set) onto the water-carrying pipe.
Push the narrow end of the screw fitting (part of the connection set) into the pipe as far as it will go.
Push the free end of the screw fitting into the inlet adapter. Screw in the pipe tight with the union nut onto the inlet adapter.
Insert the inlet adapter into the overflow unit.
Handling

3.2.6 Mounting equipment set

To avoid damage to the rosette and valve cone, only mount the equip­ment set after finishing all other work on the building site. Proceed as follows:
The inlet adapter must click into place in the overflow unit with a noticeable clicking sound.
The equipment set is not included in the scope of delivery and must be purchased separately.
Place the flange cover onto the supply flange with the straight side facing downwards and affix.
Align and fit rotatable rosette. Fit valve cone.
Multiplex Trio drain/overflow functional unit 17 from 20
Page 18
Handling
Turn rotatable rosette to check function and alignment. The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter with union nut.

3.2.7 Leakage test

The leakage test is only carried out as a visual inspection. Check the points marked in the following drawing with particular care:
Check drain fitting for visible leaks.

3.2.8 Demounting rotatable rosette

If the rotatable rosette on the overflow is to be removed, proceed as fol­lows to prevent damaging the rosette and the flange cover:
Remove the rotatable rosette in the axial direction.
Multiplex Trio drain/overflow functional unit 18 from 20
Page 19

3.3 Control

Handling
Remove the flange cover at the marked points. Remove flange cover.
The drain / overflow are controlled via rotatable rosette on the overflow. Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
The drain closes itself.
ð
Turn rotatable rosette to the right.
The drain opens itself.
ð
Setting the water inlet direction
There is a regulator for the water jet on the underside of the rotatable rosette. Proceed as follows to adjust the water jet:
Multiplex Trio drain/overflow functional unit 19 from 20
Page 20

3.4 Maintenance

Handling
Push the flow control backwards or forwards with your finger. The water flows closer or further away from the side of the bathtub depending on the direction set.
NOTICE! Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated surfaces and therefore may not be used:
3.5
– scouring agent – abrasive sponges – lime, plaster or cement dissolver – solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone. Under no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Multiplex Trio drain/overflow functional unit 20 from 20
Loading...