2 Product information 6
2.1
Standards and regulations 6
2.2
Intended use 6
2.2.1
Areas of use 6
2.2.2
Media 6
2.2.3
Drainage capacity 7
2.3
Product description 7
2.3.1
Overview 7
2.3.2
Technical data 8
3 Handling 9
3.1
Assembly information 9
3.1.1
Important note 9
3.1.2
Installation dimensions 9
3.2
Assembly 10
3.2.1
Cutting the drain to size 10
3.2.2
Mounting the odour trap 11
3.3
Disposal 16
Table of contents
Advantix odour trap 3 from 16
Page 4
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Advantix odour trap 4 from 16
Page 5
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Advantix odour trap 5 from 16
Page 6
2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
viega.com/standards
.
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
many
Typical domestic wastewater DIN 1986-3
2.2 Intended use
2.2.1 Areas of use
The Advantix odour trap is suitable for use in ViegaAdvantix shower channels base unit model 4982.10 and model 4982.20.
The drain is designed for small to medium volumes of water, which occur in e. g. residential building.
Technical information, see
Ä Chapter 2.3.2 „Technical data“ on page 8
.
The drain is suitable for horizontal connection to the drainpipe.
2.2.2 Media
The drain is intended for draining of household-type wastewater in con­stant operation, see
Ä „Regulations from section: Media“ on page 6
.
n
The short-term temperature of the wastewater may reach up to 95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
Product information
Advantix odour trap 6 from 16
Page 7
2.2.3 Drainage capacity
The drainage capacity at an accumulation height of 10 mm above the grate is 0.5 l/s
The drainage capacity at an accumulation height of 20 mm above the grate is 0.55 l/s
2.3 Product description
2.3.1 Overview
1
2
3
4
5
1 - Odour trap immersion pipe 2 - Odour trap insert 3 - O-ring 4 - Casing 5 - Adapter DN50
10
20
Product information
Advantix odour trap 7 from 16
Page 8
2.3.2 Technical data
Nominal width [DN] (drain socket)
DN40 / DN50
Drainage capacity
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Dimensions and installa­tion height
Ä Chapter 3.1.2 „Installation dimen­sions“ on page 9
Water seal level 50 mm
Load class K = 300 kg
Product information
Advantix odour trap 8 from 16
Page 9
3 Handling
3.1 Assembly information
3.1.1 Important note
Observe the instructions for use of the base unit when mounting.
Before assembly:
n Check if the drainage capacity of the drain is sufficient for the arising
water volume
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
.
n Check if the installation height of the drain corresponds with the
planned floor construction.
n Ensure that the required connection line is installed with the neces-
sary incline to the planned installation location.
During assembly:
n Observe installation dimensions.
3.1.2 Installation dimensions
Fig. 1: Dimensional drawing for model 4982.92
Dimensional drawing
Handling
Advantix odour trap 9 from 16
Page 10
95-155
95
Fig. 2: Installation height for model 4982.92
3.2 Assembly
3.2.1 Cutting the drain to size
Requirements:
n You want to cut the odour trap to the size of the reconstruction
model.
Cut the casing at the sawing groove provided for this purpose.
Cut the odour trap insert at the sawing groove provided for this pur­pose.
Installation height
Handling
Advantix odour trap 10 from 16
Page 11
Cut the odour trap immersion pipe at the sawing groove provided for this purpose.
ð
You have cut the odour trap to the size of the reconstruction model.
3.2.2 Mounting the odour trap
Check the connection element for soiling, clean if necessary.
Determine the screed height.
H
Handling
Advantix odour trap 11 from 16
Page 12
Mount the sealing element. Check the sealing element for firm seat.
Press the drain into the connection element until it snaps home.
With mounting heights of max. 70 mm, align the base unit in the mortar bed.
Provide mortar bedding to secure the drain against slipping.
Handling
Advantix odour trap 12 from 16
Page 13
Check whether grounding is required.
Set the base unit to the upper edge of the screed. Align it horizontally in all directions.
INFO! The drain is 180° rotatable.
Connect the drain DN40 or the adapter element DN50 to the drainage system.
The wastewater pipe can also be laid under the shower channel base unit.
Put in the odour trap insert.
Handling
Advantix odour trap 13 from 16
Page 14
The odour trap in installed condition.
Turn the odour trap 90° to the right.
Mount and grease the sealing element. Insert the odour trap immersion pipe.
ð
The odour trap insert has been fastened.
Check the base unit including the drain and the connection line for leak tightness.
Handling
Advantix odour trap 14 from 16
Page 15
Insert the hard foam block.
Mount the first part of the site protection.
Remove the lower protective foil and stick the adhesive points on.
Shorten the second part of the site protection if applicable, and mount it.
Remove the top protective foil of the adhesive point.
Handling
Advantix odour trap 15 from 16
Page 16
Line the shower channel incl. the drain up to the upper edge of the flange with screed.
3.3 Disposal