Viega 4980.60 Instructions For Use Manual

Page 1
for bonded sealing (tiled shower) with sealing mat Model Year built:
4980.60 from 01/2012
en_INT
Advantix Advantix bath drain 62 mm, (recon­struction model)
Instructions for Use
Page 2
Advantix Advantix bath drain 62 mm, (reconstruction model) 2 from 21
Page 3
Table of contents
1 About these instructions for use 4
1.1
Target groups 4
1.2
Labelling of notes 4
1.3
About this translated version 5
2 Product information 6
2.1
Standards and regulations 6
2.2
Intended use 7
2.2.1
Areas of use 7
2.2.2
Media 7
2.2.3
Drainage capacity 8
2.3
Product description 8
2.3.1
Overview 8
2.3.2
Technical data 8
2.4
Information for use 9
2.4.1
Installation variations 9
2.4.2
Sealing 10
2.4.3
Fire protection 12
2.5
Required accessories 12
3 Handling 14
3.1
Assembly information 14
3.1.1
Important note 14
3.1.2
Installation dimensions 15
3.1.3
Tools and materials 15
3.2
Assembly 15
3.2.1
Connecting the drain 15
3.2.2
Prepare for subsequent work 16
3.2.3
Sealing the drain 18
3.2.4
Mounting the top 19
3.3
Care 20
3.3.1
Care tips 20
3.3.2
Cleaning the drain 20
3.4
Disposal 21
Table of contents
Advantix Advantix bath drain 62 mm, (reconstruction model) 3 from 21
Page 4
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Tilers n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Advantix Advantix bath drain 62 mm, (reconstruction model) 4 from 21
Page 5
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Advantix Advantix bath drain 62 mm, (reconstruction model) 5 from 21
Page 6
2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
viega.com/standards
.
Regulations from section: Sealing
Scope / Notice Regulations applicable in Ger-
many
Stress class of the underground, as well as suitable bonded sealing
ZDB-Merkblatt 8/2012
Stress class of the underground, as well as suitable bonded sealing
Leitfaden zur Abdichtung im Ver­bund (AIV)
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A and AO
ETAG 022 T1
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A, B and C
DIBt-Bauregelliste A, Teil 2 des DIBt und Prüfgrundsätze für Abdichtungen im Verbund (PG AIV-F)
Permitted bonded sealings EN 14891
Regulations from section: Fields of application
Scope / Notice Regulations applicable in Ger-
many
Specifications not met due to water seal level and small drainage capacity.
EN 1253-1
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
many
Typical domestic wastewater DIN 1986-3
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 6 from 21
Page 7
2.2 Intended use
2.2.1 Areas of use
The drain is designed for small to medium volumes of water, which occur in e. g. residential building.
Technical information, see
Ä Chapter 2.3.2 „Technical data“ on page 8
.
The drain is a reconstruction model, which due to its low height can also be integrated into a very low floor construction without having to make a drill hole. For this reason, mounting always takes place on the raw con­crete floor.
The water seal level of 25 mm and the small drainage capacity do not meet the specifications pursuant to the standards and regulations. See Ä „Regulations from sec­tion: Fields of application“ on page 6.
Check if the drainage capacity is sufficient before mounting!
2.2.2 Media
The drain is intended for draining of household-type wastewater in con­stant operation, see
Ä „Regulations from section: Media“ on page 6
.
n
The short-term temperature of the wastewater may reach up to 95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
2.2.3 Drainage capacity
Drainage capacity at an accumulation height of 10 mm above the grate:
0.5 l/s Drainage capacity at an accumulation height of 20 mm above the grate:
0.55 l/s
10
20
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 7 from 21
Page 8
The values are dependent on the total height (H) of the drain unit.
2.3 Product description
2.3.1 Overview
1
2
3
4
5
1 - grate 2 - top, can be cut to length 3 - removable odour trap 4 - 45° angled drain socket (DN 50) 5 - base unit
2.3.2 Technical data
Nominal width [DN] (drain socket)
40/50
Drainage capacity
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Dimensions and installa­tion height
Ä Chapter 3.1.2 „Installation dimen­sions“ on page 15
Water head seal 25 mm
Load class K = 300 kg
2.4 Information for use
2.4.1 Installation variations
The mounting of the drain in a bare concrete floor is as follows:
Installing in a bare concrete floor
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 8 from 21
Page 9
n The drain is placed in a floor recess and then cast-in.
During the mounting on the floor, the drain is integrated into the floor construction. At the same time, it can e. g. be integrated into the level­ling screed or heat insulation. If necessary, a vertical drainpipe can be led through a drill hole in the floor at the same time.
NOTICE! The creation of a floor recess must be agreed with the fol­lowing people:
– a structural engineer – the on-site fire protection inspector or the specialist
engineer for fire protection
If necessary, proof of compliance with building code or an expert's report must exist.
Fig. 1: General installation example – Floor recess
Mounting on a floor
Fig. 2: General mounting example – Mounting on the floor
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 9 from 21
Page 10
2.4.2 Sealing
To protect against moisture penetration, apply sealing foils, which are to be processed in liquid state, directly below the tiles on screed and walls. The determination of the stress class and the underground as well as the selection of the suitable bonded sealing must be carried out in compliance with the valid standards and regulations, see:
Ä „Regula-
tions from section: Sealing“ on page 6
.
The bonded seal can be applied directly onto the drain flange.
Fig. 3: Diagram of a bonded seal
Bonded sealing
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 10 from 21
Page 11
Careful planning is required for professional sealing. In addition, depending on the individual dampness wear class and the type of foun­dation, a suitable BS system with a building regulations certificate of suitability must be chosen.
Furthermore, the following factors should be taken into account:
n Drain or shower channel must be equipped with a special flange,
which has an adhesive surface and a width of at least 30 mm.
n For bridging the material change from drain to screed, either a suit-
able sealing collar or sealing tape designed for overlapping with the BS over a width of at least 50 mm must be used.
n The screed must be laid at a minimum incline of 1–2 %. n The installation must be carried out properly in acc. with the
mounting instructions and the manufacturer's information.
1
9 8 7 6
2 3 4 5
Fig. 4: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 - Grate 2 - Top piece with adhesive flange 3 - Tile 4 - Tile cement 5 - Bonded sealing 6 - Screed 7 - Sealing collar 8 - Mat 9 - Adhesive flange
In connection with suitable drains, only approved bonded sealings with proof of practicability in keeping with building law may be used. See
Ä „Regulations from section: Sealing“ on page 6
.
Information regarding the procedure can be found in the instructions for use of the corresponding product.
Important note
Permitted bonded seals
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 11 from 21
Page 12
2.4.3 Fire protection
Advantix shower channels and drains can both be fitted to be fire proof. The R120 pipe lead-in can be used for this purpose in the floor con­struction. In this way, a fire resistance time of up to 120 minutes can be achieved.
Fig. 5: Example: fire protection pipe lead-in
Mounting instruction of the R120 pipe lead-in see model 4923.5, Art.-No. 491 673.
2.5
Required accessories
Advantix tops are available in a number of sizes and variations. You can also only buy an Advantix top frame and then purchase a suitable designer grate separately (see catalogue).
Top
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 12 from 21
Page 13
The drain can be fitted with a sieve insert (model 4958) to collect dirt.
Advantix drains can be equipped with an additional odour barrier, which also closes the drain odour-tight, if the water seal in the odour trap has evaporated. Odour nuisance is even avoided with drains that are only seldom used. Odour barriers can be found in the catalogue.
Sieve insert
Odour barrier
Product information
Advantix Advantix bath drain 62 mm, (reconstruction model) 13 from 21
Page 14
3 Handling
3.1 Assembly information
3.1.1 Important note
Before assembly:
n Check if the drainage capacity of the drain is sufficient for the arising
water volume
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
.
n Check if the installation height of the drain corresponds with the
planned floor construction.
n Ensure that the required connection line is installed with the neces-
sary incline to the planned installation location.
n If necessary, supply the required accessories
Ä Chapter 2.5
„Required accessories“ on page 12
.
During assembly:
n Observe installation dimensions.
After assembly:
n The drain flange must be fully lined with mortar.
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 14 from 21
Page 15
3.1.2 Installation dimensions
Fig. 6: Dimensional drawing model 4980.60
3.1.3 Tools and materials
n Top with grate, if not included in scope of delivery
Ä Chapter 2.3.1
„Overview“ on page 8
n Material for securing the drain
3.2 Assembly
3.2.1 Connecting the drain
The connection to the wastewater system must be completed before the drain can be installed in the floor construction. Proceed as follows:
Requirements:
n A pipe to the planned drainage position is already in place for the
connection to the wastewater system.
n The drainpipe has an internal sealing lip.
Required material
Connecting to the wastewater system
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 15 from 21
Page 16
Saw drain elbow, if the wastewater pipe only has a diameter of 40 mm.
Push union nut, sliding ring and sealing onto the connection elbow. Screw the union nut onto the odour trap. Align the connection elbow on the joint. Push the drain socket into the drainpipe completely.
3.2.2 Prepare for subsequent work
A few points must be observed to integrate the drain into the floor con­struction properly. For this reason, proceed as follows to prepare the drain for subsequent work:
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 16 from 21
Page 17
Requirements:
n The drain is connected. n The protective foil and the yellow protective plugs are to be found,
undamaged, on the drain.
Position odour trap onto the bare concrete ceiling.
Check the correct seating of both O-rings on the flange. Push the flange into the drain unit as far as it will go. Position the drain at the desired height at the place of use.
Depending on planning, the drain can be integrated into concrete, screed or a heat insulation layer, for example. It is important that the upper edge of the drain flange is flush with the upper edge of the sealing layer. If necessary, raise or lower the drain in the existing floor using suitable material.
Align drain horizontally using a spirit level.
Secure the drain in such a way that it cannot shift when the subse­quent works are applied.
Most importantly, it must be ensured that the drain does not float when the concrete or screed is poured in.
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 17 from 21
Page 18
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces.
3.2.3 Sealing the drain
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Check the proper completion of the subsequent work.
Screed and floor tiles must be laid at an incline of 1–2 % in the direction of the drain.
Requirements:
n The flange is free of heavy soil. n The complete surface of the flange is lined with material and undam-
aged.
Remove protective foil.
Bonded sealing
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 18 from 21
Page 19
Apply the bonded sealing on the dry screed and spread to the inner edge of the flange fleece.
NOTICE! Observe the bonded sealing manufacturer's instructions for use.
Lay the sealing collar into the bonded sealing.
Apply a second layer of bonded sealing onto the sealing collar and, if necessary, onto the floor.
3.2.4 Mounting the top
The top with the grate must still be mounted to finish off the mounting of the drain. Proceed as follows:
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 19 from 21
Page 20
Calculate the height of the floor construction from the edge in the inside of the drain up to the upper edge of the tiles.
Starting with the upper edge, transfer the measured height onto the top.
Cut the top to the marked height.
INFO! No backflow seal may be fitted so that any seepage that may occur can drain off without hindrance!
Remove yellow protective plug.
Place the top into the drain and align according to the tiles. Work the top into the screed or the floor covering.
3.3
Care
3.3.1 Care tips
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the grate and frame. Under no circum­stances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
3.3.2
Cleaning the drain
We recommend using a mild cleaning agent and a washing-up brush for cleaning.
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 20 from 21
Page 21
Remove and clean grate.
Remove and clean immersion pipe.
Clean drain.
Replace immersion pipe. Re-insert grate.
3.4
Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Handling
Advantix Advantix bath drain 62 mm, (reconstruction model) 21 from 21