Viega 4966.10 User guide

Page 1
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length con‐ tinuously, 70 mm (reconstruction model)
Instructions for Use
for bonded sealing (tiled shower) with sealing mat
Model Year built:
4966.10 from 01/2012
en_INT
Page 2
Page 3

Table of contents

1 About these instructions for use 5
Table of contents
1.1
1.2
1.3
Target groups 5
Labelling of notes 5
About this translated version 6
2 Product information 7
2.1
2.2
2.2.1
2.2.2
2.2.3
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.4
2.4.1
2.4.2
2.5
Standards and regulations 7
Intended use 8
Areas of use 8
Media 8
Drainage capacity 8
Product description 9
Installation variations 9
Overview of the components 13
Technical data 15
Sound protection 15
Information for use 15
Sealing 15
Fire protection 17
Required accessories 17
3 Handling 18
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.2.9
Assembly information 18
Important note 18
Tools and materials 18
Installation dimensions 19
Recommended procedure 21
Assembly 21
Calculating the profile length in niche installation 21
Shortening the profile 23
Mounting the closing caps on base unit 25
Pre-mounting extending parts 25
Determine height 29
Mounting feet and drain socket 29
Aligning and connecting 33
Preparing for further work 37
Sealing the shower channel 38
Page 4
Table of contents
3.2.10
3.2.11
3.3
3.3.1
3.3.2
3.4
Inserting the sieve 44
Mounting the standing grate 44
Care 47
Care tips 47
Cleaning 48
Disposal 49
Page 5
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document; for further information, go to viega.com/legal.

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Tilers n Consumers
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
1.2
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns of possible life-threatening injury.
WARNING! This symbol warns of possible serious injury.
CAUTION! This symbol warns of possible injury.
NOTICE! This symbol warns of possible damage to property.
This symbol gives additional information and hints.
Page 6

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand‐ ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Page 7

2 Product information

2.1 Standards and regulations

The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards.
Regulations from section: Sealing
Scope / Notice Regulations applicable in Ger‐
Product information
many
Stress class of the underground, as well as suitable bonded sealing
Stress class of the underground, as well as suitable bonded sealing
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A and AO
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A, B and C
Permitted bonded sealings EN 14891
Regulations from section: Media
Scope / Notice Regulations applicable in Ger‐
Typical domestic wastewater DIN 1986-3
ZDB-Merkblatt 8/2012
Leitfaden zur Abdichtung im Ver‐ bund (AIV)
ETAG 022 T1
DIBt-Bauregelliste A, Teil 2 des DIBt und Prüfgrundsätze für Abdichtungen im Verbund (PG AIV-F)
many
Regulations from section: Sound protection
Scope / Notice Regulations applicable in Ger‐
many
Fulfilled noise protection require‐ ments
Fulfilled noise protection require‐ ments
DIN 4109
VDI 4100
Page 8

2.2 Intended use

2.2.1 Areas of use

Product information
Regulations from section: Important notes
Scope / Notice Regulations applicable in Ger‐
many
Dimensions of slots and recesses EN 1996
The shower channel is used in the bathroom as a drain for a floor-level shower. It is designed for small to medium volumes of water, which occur in e. g. residential building.

2.2.2 Media

2.2.3
Drainage capacity
Technical information, see Ä Chapter 2.3.3 „Technical data“ on page 15.
Due to its flat installation height, the shower channel is especially suit‐ able for the refurbishment of old buildings with a low floor thickness.
The shower channel is intended for draining of household-type waste‐ water in constant operation, see Ä „Regulations from section: Media“ on page 7.
n The short-term temperature of the wastewater may reach up to
95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
When two drains are combined using a collector line and a drainage capacity of > 0.8 l/s is expected, the dimensioning of the drainpipe must be DN 70.
The maximum drainage capacity is 1.6 l/s.
For assembly with one drain, with sieve insert
Accumulation height Installation height 70 mm Installation height 95 mm
10 mm 0.55 l/s 0.55 l/s
20 mm 0.6 l/s 0.6 l/s
Page 9

2.3 Product description

1
2 3

2.3.1 Installation variations

Product information
The length and shape of the Advantix Vario shower channel can be variably adapted. Use the shower channel configu‐ rator to calculate the material required for any design avail‐ able: http://advantix-vario.viega.de/
The length of the shower channel can be adapted to suit:
n The base unit can be shortened to a length of 300 mm with milli‐
metre precision.
n The length of the shower channel can be extended up to 2800 mm
by installing accessory parts.
The shower channel can be altered in the following way using the fol‐ lowing accessories:
Fig. 1: Installation possibilities
1 straight version, also possible with two base units 2 L-version 3 U-version
Page 10
1 2
3
a
b
c
d
Extension parts
Product information
The following parts are available for individual shower channel design:
1 end closing piece, 275 mm 2 connection piece, 210 mm 3 connection piece 90°, 290 x 290 mm
end closing piece
Instead of the closing cap, a long element, the so-called "end closing piece" can be mounted onto the base unit. The base unit can therefore be extended accordingly.
Fig. 2: Installation possibilities with end closing piece
a max. 1451 mm b max. 1680 mm c max. 2651 mm d max. 2880 mm
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 10 from 49
Page 11
a
b
d
c
Product information
Connection piece
The connection piece serves the purpose of joining two base units together. In this case, one of the base unit units must be shortened by the length of the connection piece (= 210 mm).
The connection piece may not be shortened.The connection piece may not be used with the L or U
versions.
Fig. 3: Models with connection piece
a min. 831 mm b max. 2422 mm c max. 2651 mm d max. 2880 mm
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 11 from 49
Page 12
1
2
a b
b
a
1
2
a c
a c
b b
Product information
Connection piece 90°
The connection piece 90° enables the mounting shower channels in L­or U-models.
Fig. 4: Installation possibilities with connection pieces 90° for L version
1 with closing caps 2 with end closing pieces a 557–1457 mm b max. 1686 mm
Fig. 5: Installation possibilities with connection pieces 90° for U version
1 with closing caps 2 with end closing pieces a 557–1457 mm b 792–1692 mm c max. 1686 mm
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 12 from 49
Page 13

2.3.2 Overview of the components

1 2
4
5
13
8
7
6
12
9
1415
16
17
18
19
3
10
11
Basic model
Product information
Fig. 6: Components and scope of delivery
1 protective insert made of hard foam 2 standing grate* 3 test adapter 4 grate supports* 5 cover caps* 6 grate holder* 7 screws for adjusting the feet* 8 fixing screws 9 closing cap 10 feet 11 sieve* 12 base unit with drain socket 13 connection elbow 40/50 14 mounting adhesive 15 sealing tape 16 odour trap 17 seal 18 fixing material 19 flange — bag with grease — 1 size 4 bit * not included in scope of delivery
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 13 from 49
Page 14
1
2
3
4
7
6
5
8
9
1
2
3
4
7
6
5
89
Extension parts
Product information
Fig. 7: end closing piece, scope of delivery
1 protective insert made of hard foam 2 protective foil 3 end closing piece 4 Allen key size 4 5 sealing tape 6 foot, height-adjustable 7 fixing material 8 screws 9 spacer
Fig. 8: connection piece 90°, scope of delivery
1 protective insert made of hard foam 2 protective foil 3 sealing tape 4 spacer 5 connection piece 90° 6 screws 7 Allen key size 4 8 foot, height-adjustable
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 14 from 49
9 fixing material
Page 15

2.3.3 Technical data

Product information
Nominal width [DN] 40 / 50
Material Base unit made of plastic

2.3.4 Sound protection

2.4
Information for use

2.4.1 Sealing

Bonded sealing
Drainage capacity
Dimensions and installa‐ tion height
Water seal level 25 mm
Load max. 120 kg load per standing grate
The measured sound level during water drainage is 19 dB(A). For infor‐ mation on sound protection requirements met, see Ä „Regulations from section: Sound protection“ on page 7.
Ä
Chapter 2.2.3 „Drainage capacity“
on page 8
Ä
Chapter 3.1.3 „Installation dimen‐
sions“ on page 19
bracket
To protect against moisture penetration, apply sealing foils, which are to be processed in liquid state, directly below the tiles on screed and walls. The determination of the stress class and the underground as well as the selection of the suitable bonded sealing must be carried out in compliance with the valid standards and regulations, see: Ä „Regula‐
tions from section: Sealing“ on page 7.
Fig. 9: Diagram of a bonded seal
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 15 from 49
Page 16
1-2%
1 2 43 5
8 67
Important note
Product information
Careful planning is required for professional sealing. In addition, depending on the individual dampness wear class and the type of foun‐ dation, a suitable thin bed sealing with a building regulations certificate of suitability must be chosen.
Furthermore, the following factors should be taken into account:
n Drain or shower channel must be equipped with a special flange,
which has an adhesive surface and a width of at least 30 mm.
n For bridging the material change from drain to screed, either a suit‐
able sealing collar or sealing tape designed for overlapping with the thin bed sealing over a width of at least 50 mm must be used.
n The screed must be laid at a minimum incline of 1–2 %. n The installation must be carried out properly in acc. with the
mounting instructions and the manufacturer's information.
Fig. 10: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 Grate 2 Top piece with adhesive flange 3 Tile 4 Tile cement 5 Bonded sealing 6 Screed 7 sealing collar 8 adhesive
Permitted bonded seals
In connection with suitable drains, only approved bonded sealings with proof of practicability in keeping with building law may be used. See
Ä
„Regulations from section: Sealing“ on page 7.
Information regarding the procedure can be found in the instructions for use of the corresponding product.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 16 from 49
Page 17

2.4.2 Fire protection

Product information
Advantix shower channels and drains can both be fitted to be fire proof. The R120 pipe lead-in can be used for this purpose in the floor con‐ struction. In this way, a fire resistance time of up to 120 minutes can be achieved.
2.5
Fig. 11: Example: fire protection pipe lead-in
Mounting instruction of the R120 pipe lead-in see model 4923.5, Art.-No. 491 673.
Required accessories
If the basic model of the Vario shower channel is extended by additional components, the following accessories are required for the mounting of these components.
Per installed component one corresponding standing grate set and one accessory set is required. The complete range and the required infor‐ mation can be found in the catalogue.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 17 from 49
Page 18

3 Handling

3.1 Assembly information

3.1.1 Important note

Before assembly:
n Check if the drainage capacity of the model chosen is sufficient for
n In the case of the connection of two or three shower channels:
n An adequate level of floor covering stability must be guaranteed
n The dimensions of slots and recesses must be in compliance with
Handling
the arising water volume Ä Chapter 2.2.3 „Drainage capacity“ on page 8.
Observe the information for dimensioning of collective lines Ä Chapter 2.2.3 „Drainage capacity“ on page 8.
Ä
Chapter 2.3.3 „Technical data“ on page 15. This can be achieved
either through an adequate covering of screed or another alternative solution. Relevant measures must be considered before mounting.
Ä
the regulations from section
notes“ on page 8.
„Regulations from section: Important

3.1.2 Tools and materials

Special tools
During assembly:
n Observe installation dimensions. n For barrier-free showers:
Position the shower channel in such a way that wheelchair wheels can only cross it at right angles. Viega recommends mounting the shower channel as close to the wall as possible.
n Do not use mounting adhesive older than 18 months. n Position the shower channel in such a way that the grate is remov‐
able.
After assembly:
n The shower channel must be fully lined with mortar. n The sealing accessories should be given to the person responsible
for the bonded sealing (e. g. tiler).
n Coordinate all relevant installation details, especially regarding the
bonded sealing, with those responsible for the subsequent work.
n Spanner size 13 n Hand saw (saw blade maximum 1.5 mm) n An Allen key in each of the sizes 2.5 and 3 n Drill, 6 mm n Tool for the removal of the grate (e. g. model 4965.90,
art. no. 689 704)
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 18 from 49
Page 19
60°
60°
20
50
110
3070-95
322 - 1222
1322
50
4
20
20
50
33
Ø40/50
140
270
Mounting adhesive
Fig. 12: Filling date of the mounting adhesive
Handling
Mounting adhesive can be used for a maximum of 18 months.
The filling date is found on the top edge of the cartridge. The first two numbers represent the month, the following number the year.
Example
085... Filling date = August (08) 2015 (5)

3.1.3 Installation dimensions

Shower channel, basic model with one base unit
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 19 from 49
Fig. 13: Dimensions of base unit basic model
Page 20
10
33
110
210
10
33
110
275
10
33
245
290
110
245
290
110
Connection piece
Handling
Fig. 14: Dimensions of connection piece
end closing piece
connection piece 90°
Fig. 15: Dimensions of end closing piece
Fig. 16: Dimensions of connection piece 90°
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 20 from 49
Page 21

3.1.4 Recommended procedure

The variable installation possibilities of the Advantix Vario require careful planning of the assembly steps. Viega generally recommends the fol‐ lowing order:
1. Calculate length and cut profile to length if necessary.
2. Pre-mount all short profile parts.
3. Connect the pre-mounted parts to the desired shape.
4. Calculate height and mount feet.
5. Mount base unit and align shower channel.
6. Line the shower channel with screed and seal.
7. Tile the floor.
8. Mount the standing grate.
Handling
Description of the assembly steps, see on page 21.
3.2
Assembly

3.2.1 Calculating the profile length in niche installation

When fitting a shower channel in a niche, the correct size of niche is of importance so that it will be possible to remove the grate. The exact profile length must be calculated for this. The base unit without closing caps is taken as the profile length.
Ä
Chapter 3.2 „Assembly“
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 21 from 49
Page 22
322 - 1222
A A
B B
150 150
Handling
Fig. 17: Niche dimensions
A = Minimum width of the niche from plaster to plaster B = Minimum width of the niche from tile to tile
The basis of the calculation for the length of the profile is the shower niche after plastering (see dimension A).
The length of the closing caps is subtracted from this measurement. The result is the profile length.
Example
1030 mm (plastered shower niche)
100 mm (2 closing caps 50 mm each)
=
930 mm (profile length)
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 22 from 49
Page 23

3.2.2 Shortening the profile

150
Handling
If two Vario shower channels are to be joined together,
one of the base units must be shortened by at least 210 mm Ä Chapter 3.2.2 „Shortening the profile“ on page 22.
– End closing pieces, connection pieces and connection
pieces 90° must not be shortened.
Calculate profile length, also see Ä Chapter 3.2.1 „Calculating the profile length in niche installation“ on page 21.
Transfer the length of the profile onto the shower channel.
INFO! Depending on the installation situation, the shower channel can be shortened on one or both sides. The position of the drain may be chosen freely. However, the distance from the middle of the drain to the end of the profile may not be less than 150 mm.
Shorten the profile with a hacksaw.
The saw blade must not be wider than 1.5 mm.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 23 from 49
Page 24
Handling
Carefully deburr all edges.
Particular attention should be paid to surfaces in contact with the seal.
The profile must be lubricated in the area around the seal.
INFO! No lubricant should come into contact with the flange! Optimal adhesion of the sealing material is only ensured on a grease-free flange.
If necessary, clean flange. Use the cleaning cloth supplied or a non­greasing cleaner, e. g. isopropanol.
You now have various possibilities:
n Mount closing caps and base unit. Ä Chapter 3.2.3 „Mounting the
closing caps on base unit“ on page 25
n Mount extending parts. Ä Chapter 3.2.4 „Pre-mounting extending
parts“ on page 25
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 24 from 49
Page 25

3.2.3 Mounting the closing caps on base unit

M 3 Nm
A
Screw the closing cap onto the profile straight.
When using a cordless screwdriver, make the last few turns by hand. Only tighten screws hand-tight!
The closing cap is properly mounted when the seal is pushed
ð
together gently.
Handling
You must now calculate the height and align the shower channel
Ä
Chapter 3.2.5 „Determine height“ on page 29.

3.2.4 Pre-mounting extending parts

To start with, all short profile parts should pre-mounted. Then the pre­mounted units are connected to the base unit.
NOTICE! Risk of breakage when lifting
Do not lift or turn pre-mounted units on one side.
– In the case of L and U designs, lift the sides at the same
time.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 25 from 49
Page 26
Mounting the end closing piece
M 3 Nm
A
4
Screw the end closing piece onto the profile.
When using a cordless screwdriver, make the last few turns by hand. Only tighten screws hand-tight!
The end closing piece is properly mounted when the seal is
ð
pushed together gently.
Handling
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 26 from 49
Page 27
Mounting the connection piece
4
M 3 Nm
A
Screw the connection piece onto the profile straight.
When using a cordless screwdriver, make the last few turns by hand. Only tighten screws hand-tight!
The connection piece is properly mounted when the seal is
ð
pushed together gently.
Handling
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 27 from 49
Page 28
Mounting the connection piece 90°
4
M 3 Nm
A
Screw the connection piece 90° onto the profile straight.
When using a cordless screwdriver, make the last few turns by hand. Only tighten screws hand-tight!
The connection piece 90° is properly mounted when the seal
ð
is pushed together gently.
Handling
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 28 from 49
Page 29

3.2.5 Determine height

min.70
max.95
Handling
Determine screed height (H).
The installation height is variable from 70–95 mm.
At installation height over 70 mm:
Line the odour trap. This prevents the odour trap from slipping off the drain socket.

3.2.6 Mounting feet and drain socket

If two Vario-shower channels are connected to one another, one of the base units must be shortened by at least 210 mm
Ä
Chapter 3.2.2 „Shortening the profile“ on page 23.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 29 from 49
Page 30
Calculate the number of feet required using the table.
max. 100 mm
max. 100 mm
Handling
Length of the
Number of feet Spacing
shower channel
30–60 cm 2
60–90 cm 3
60–90 cm 4
90–120 cm 4
90–120 cm 4
The following applies for mounting the feet:
n The maximum permissible distance between two feet is 400 mm. n The maximum permissible distance between a foot and a fixing point
of two parts is 100 mm. A fixing point is the point where two components are screwed
together.
n During the mounting of connection pieces 90°:
An additional foot must be mounted below the corner angle
Fig. 18: distance between fixing point and foot = maximum 100 mm
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 30 from 49
Page 31
Handling
Fig. 19: when using the connection piece 90°, an additional foot must be mounted below the corner
Position the foot and push the profile into place.
Insert the drain socket
WARNING! Risk of breakage when lifting Do not lift or turn the shower channel on one side.
In the case of L and U designs, lift the sides at the same time.
Lubricate seal, inside and outside.
Insert seal.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 31 from 49
Page 32
Handling
Push the shower channel with outlet pipe into the odour trap as far as it will go.
Check whether the shower channel is inserted as far as it will go.
INFO! The odour trap may only be turned in its installed condi‐ tion!
If necessary, adjust the odour trap by turning.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 32 from 49
Page 33

3.2.7 Aligning and connecting

13
6
Aligning and connecting the base unit
Handling
The water that occurs must be discharged properly. If required, multiple drains and suitably dimensioned drain‐ pipes must be installed Ä Chapter 2.2.3 „Drainage capacity“ on page 8.
Align shower channel horizontally.
The water can then drain away well.
Fix the foot height adjustment with lock nuts.
Connect the drain to the wastewater system.
Secure the feet in place with fixing material if necessary.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 33 from 49
Page 34
Aligning the end closing piece
Handling
Align the shower channel and connection piece horizontally to one another.
Insert spacer.
The spacers prevent the shower channel from being deformed when the screed hardens later.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 34 from 49
Page 35
Aligning the connection piece
Handling
Align the shower channel and connection piece horizontally to one another.
Insert spacer.
The spacers prevent the shower channel from being deformed when the screed hardens later.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 35 from 49
Page 36
Aligning the connection piece 90°
90°
Handling
Align shower channel and connection piece 90° both horizontally and perpendicular to one another.
Insert spacer.
The spacers prevent the shower channel from being deformed when the screed hardens later.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 36 from 49
Page 37

3.2.8 Preparing for further work

Handling
Fill shower channel with water.
Check drain casing and pipe for leaks.
Insert the test adapter into the drain opening of the shower channel.
Fill the shower channel up to just below the flange with water.
Check the end closing pieces for leaks.
If necessary, shorten the protective foil and stick onto the flange.
Completely cover the closing caps with protective foil.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 37 from 49
Page 38
Lining with screed
Handling
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the shower channel, leaks may occur when pressure is applied.
Inform the subsequent workers that the shower channel must be fully lined and that there must be no hollow spaces.
Requirements:
n The flange must be coated with protective foil.
INFO! Screed and floor tiles must be laid at an incline of 1–2 % in the direction of the shower channel.

3.2.9 Sealing the shower channel

Remove protective foil.
Screed and floor tiles must be laid at an incline of 1–2 % in the direction of the shower channel.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 38 from 49
Page 39
Handling
When using extension pieces:
Remove spacer.
If necessary, clean flange.
Use the cleaning cloth supplied or a non-greasing cleaner, e. g. iso‐ propanol.
Cut protective insert to size and insert.
Cut the sealing tape strips generously.
The strips should overlap when stuck on.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 39 from 49
Page 40
Check the expiry date on the cartridge, see Ä „Mounting adhe‐
ca. 8 mm
sive“ on page 19.
Open the aluminium cover at the end of the cartridge, and lift.
Fully pierce the membrane in the thread of the cartridge.
Screw the nozzle on.
Cut the nozzle so that the opening is approx. 8 mm wide.
Handling
Apply mounting adhesive in curves.
Observe the shelf life of the mounting adhesive, see Ä „Mounting adhesive“ on page 19.
Distribute the mounting adhesive evenly using a smooth spatula.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 40 from 49
Page 41
Handling
Apply the first layer of bonded sealing generously onto the screed.
Observe the bonded sealing manufacturer's instructions for use.
Press the sealing tape firmly onto the mounting adhesive and bonded sealing.
In doing so, leave approx. 10 mm to the protective insert uncovered.
Position the sealing tape on the flange so that the flange and screed are uniformly covered.
Overlap the corners in the process.
Stick the overlapping strips together at the corners with mounting adhesive.
Rework the sticking points with a roller.
Let the adhesive dry for approx. 4 hours.
Apply the second layer of bonded sealing generously onto the sealing tape and floor screed.
If no cover trim is to be fitted, the floor can be tiled.
Further see Ä „Mounting without cover trim rail“ on page 43.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 41 from 49
Page 42
Mounting with cover trim rail
Handling
Stick the profile in a straight line on the insert.
The rail must be closed with the protective insert at both ends.
Deburr edges that were cut.
Avoid differences in height between different parts of the strip.
You have installed the shower channel.
ð
The floor can now be tiled.
Further see Ä „Mounting without cover trim rail“ on page 43.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 42 from 49
Page 43
Mounting without cover trim rail
Handling
Stick the tiles right up to the protective insert.
Connect the tile edge onto the channel side with tile cement or joint filler.
Thus no water can get under the floor covering during showering.
INFO! To ensure that penetrating dampness in the channel area can dry off, the joint edges must be sealed with tile adhesive or joint filler. This is of particular relevance when there is a large number of joints, e. g. with mosaic tiles.
The shower channel is installed and the tile edge can be pol‐
ð
ished.
CAUTION! Avoid sharp edges in the following places in the barefoot area:
– on tiles – on cover trims – on cover trim profiles
Optionally, you can now insert the sieve, see Ä Chapter 3.2.10 „Inserting the sieve“ on page 44.
Finally, a standing grate must be mounted, see Ä Chapter 3.2.11 „Mounting the standing grate“ on page 44. See the catalogue for suit‐ able standing grates.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 43 from 49
Page 44

3.2.10 Inserting the sieve

Handling
Optionally, a sieve can be inserted. When using the sieve, the drainage capacity drops by 0.05 l/s per drain.
Remove protective insert.
Insert the sieve above the drain in the channel gap.
To finish with, a standing grate must be mounted.

3.2.11 Mounting the standing grate

Note regarding accessories
The total length of the shower channel increases if the basic model of the Vario shower channel is extended with other parts. In this case, the relevant accessory must be mounted for every extra part.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 44 from 49
Page 45
Assembly steps
Handling
With natural stone covering, observe the correct height and use the mounting material from the accessory set for natural stone covering.
Remove protective insert.
Insert screws.
Place the grate holder onto the screw and adjust to tile height.
The maximum height of the standing grate is 20 mm above the flange.
When using the natural stone set, the maximum height of the standing grate is 30 mm above the flange.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 45 from 49
Page 46
Handling
The upper edge of the grate holder must be approx. 1 mm below the upper edge of the tiles.
Determine the length of the standing grate.
INFO! Use the standing grate with a length of 200 mm for end closing pieces and connection pieces 90°.
If required, shorten the standing grate with a handsaw and deburr.
Do not use a circular saw or angle grinder.
INFO! The standing grate with a length of 200 mm must not be shortened!
Secure the grate supports to the standing grate.
Distribute the standing grate supports in such a way that there is a grate support fitted after every one third of the grate.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 46 from 49
Page 47
Insert the standing grate.
Replace cover caps.
Handling
3.3
Care

3.3.1 Care tips

The cover caps can be moved by up to 9 mm (see fig,).
Normal soap or a mild cleaning agent can be used for regular mainte‐ nance and prevention of lime scale on the grate and frame. Use no scouring agent or abrasive objects.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. Rinse the detergent very thor‐ oughly with clear water after the prescribed dwell time. There should be no residue on the components.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 47 from 49
Page 48

3.3.2 Cleaning

Handling
Viega recommends using a mild cleaning agent, a cloth and a washing­up brush for cleaning.
Remove cover caps and standing grate.
If applicable, remove sieve.
Insert cleaning device.
Place the plunger onto the cleaning device and clean the shower channel.
Remove the cleaning device.
Remove the standing grate.
Replace cover caps.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 48 from 49
Page 49

3.4 Disposal

Handling
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Advantix Vario base unit, for Advantix Vario shower channel, can be cut to length continuously, 70 mm (reconstruction model) 49 from 49
Loading...