Viega 4956.4 Instructions For Use Manual

Page 1
Kellermeister cellar drain
Instructions for Use
Model Year built:
4956.4 from 01/1998
en_INT
Page 2
Kellermeister cellar drain 2 from 12
Page 3

Table of contents

1 About these instructions for use 4
Table of contents
1.2
1.3
Target groups 4 Labelling of notes 4 About this translated version 5
2 Product information 6
2.1
2.2
2.2.1
2.2.2
2.2.3
2.3
2.3.1
2.3.2
2.4
2.4.1
2.5
Standards and regulations 6 Intended use 6 Areas of use 6 Media 6 Drainage capacity 7 Product description 7 Overview 7 Technical data 8 Information for use 8 Installation variations 8 Accessories 8
3 Handling 9
3.1
3.1.1
3.1.2
3.1.3
3.2
3.2.1
3.3
3.3.1
3.3.2
3.4
Assembly information 9 Important note 9 Installation dimensions 9 Tools and materials 10 Assembly 10 Connecting the drain 10 Care 11 Care tips 11 Cleaning the drain 11 Disposal 12
Kellermeister cellar drain 3 from 12
Page 4
About these instructions for use

1 About these instructions for use

Trade mark rights exist for this document, further information can be found at

1.1 Target groups

The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Tilers n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
viega.com/legal
.

1.2 Labelling of notes

The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Kellermeister cellar drain 4 from 12
Page 5

1.3 About this translated version

This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Kellermeister cellar drain 5 from 12
Page 6

2 Product information

2.1 Standards and regulations

The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
Typical domestic wastewater DIN 1986-3
viega.com/standards
Product information
.
many

2.2 Intended use

2.2.1 Areas of use

2.2.2 Media

The drain is intended for use in floor constructions without sealing – e. g. cellars where wastewater occurs in small quantities at irregular intervals.
Technical information, see
The drain is intended for draining of household-type wastewater in con­stant operation, see
n
The short-term temperature of the wastewater may reach up to 95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
Ä Chapter 2.3.2 „Technical data“ on page 8
Ä „Regulations from section: Media“ on page 6
.
.
Kellermeister cellar drain 6 from 12
Page 7

2.2.3 Drainage capacity

1
2
10
20
Product information

2.3 Product description

2.3.1 Overview

Nominal width [DN] (drain
100
socket)
Drainage capacity at an accumu-
1.6 l/s lation height of 20 mm above the grate
The values are dependent on the total height of the drain unit.
Fig. 1: Components
1 - grate, model 4956-551 2 - base unit
Kellermeister cellar drain 7 from 12
Page 8

2.3.2 Technical data

Product information

2.4 Information for use

2.4.1 Installation variations

Nominal width [DN] (drain socket)
Nominal width [DN] (inlet)
Drainage capacity
100
50 or 70 (only in connection with connecting piece model 4997)
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Water head seal 50 mm
Dimensions and installation height
Load class K = 300 kg
The drain can be mounted in the following way:
n in a drill hole n in a floor recess
Ä Chapter 3.1.2 „Installation dimensions“
on page 9

2.5 Accessories

Optional accessories
Optionally, a connecting piece can be fitted. The connecting piece serves as a possible additional inlet (DN 50 or DN70).
Kellermeister cellar drain 8 from 12
Page 9

3 Handling

3.1 Assembly information

3.1.1 Important note

Before assembly:
n Check if the drainage capacity of the drain is sufficient for the arising
n Check if the installation height of the drain corresponds with the
n Ensure that the required connection line is installed with the neces-
During assembly:
n Observe installation dimensions.
water volume
planned floor construction.
sary incline to the planned installation location.
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Handling
.

3.1.2 Installation dimensions

Fig. 2: Dimensional drawing
Kellermeister cellar drain 9 from 12
Page 10

3.1.3 Tools and materials

Required material
n Material for securing the drain n For the mounting of the connecting piece (optional):

3.2 Assembly

3.2.1 Connecting the drain

Connecting to the wastewater system
The connection to the wastewater system must be completed before the drain can be installed in the floor construction. Proceed as follows:
Requirements:
Handling
compass saw
Mounting the drain
n A pipe to the planned drainage position is already in place for the
connection to the wastewater system.
n The drainpipe has an internal sealing lip.
Push the drain socket into the drainpipe completely.
Position the drain at the desired height at the place of use. If neces­sary, raise or lower in the existing floor using suitable material.
Align drain horizontally using a spirit level.
Kellermeister cellar drain 10 from 12
Page 11
Handling
Secure the drain in such a way that it cannot shift when the subse­quent works are applied.
Most importantly, it must be ensured that the drain does not float when the concrete or screed is poured in.
Work the drain into the screed or floor covering.
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces.

3.3 Care

3.3.1 Care tips

3.3.2 Cleaning the drain

Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the grate and frame. Under no circum­stances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
We recommend using a mild cleaning agent and a washing-up brush for cleaning.
Remove and clean grate.
Kellermeister cellar drain 11 from 12
Page 12
Clean drain.
Re-insert grate.
Handling

3.4 Disposal

Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.