Target groups4
Labelling of notes4
About this translated version5
2Product information6
2.1
2.1.1
2.2
2.2.1
Intended use6
Areas of use6
Product description6
Overview6
3Handling7
3.1
3.1.1
3.1.2
3.2
3.3
Assembly information7
Installation dimensions7
Tools and materials7
Assembly8
Disposal9
Advantix clamping ring3 from 9
Page 4
About these instructions for use
1About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal
1.1Target groups
The information in this instruction manual is directed at the following
groups of people:
n Heating and sanitary professionals and trained personnel
n Tilers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
.
1.2Labelling of notes
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
Advantix clamping ring4 from 9
Page 5
1.3About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Advantix clamping ring5 from 9
Page 6
2Product information
2.1Intended use
2.1.1Areas of use
The Advantix clamping ring is intended for fastening a sealing collar on
an Advantix drain.
2.2Product description
2.2.1Overview
Product information
Fig. 1: Scope of delivery
1fixing screws
2clamping ring, stainless steel
3sealing element
Advantix clamping ring6 from 9
Page 7
3Handling
3.1Assembly information
3.1.1Installation dimensions
Handling
Fig. 2: Dimensional drawing
3.1.2Tools and materials
Required tools
n screwdriver
Required material
n sealing collar
Advantix clamping ring7 from 9
Page 8
3.2Assembly
Handling
Requirements:
n The drain has been mounted.
n A suitable sealing collar is available.
n The flange is free of heavy soil.
n The complete surface of the flange is lined with material and undam-
aged.
If required, clean the flange of coarse soil (e. g. from screed).
Insert sealing ring.
The sealing ring must lie in the groove between the flange and the
screw holes.
INFO! The Viega sealing collar has two differently coated sides.
One side is coated with bitumen and the other side with EPDM. If
the additional sealing takes place with bitumen sealing lanes, the
sealing collar must be used with the bitumen side facing
upwards. If EPDM sealing lanes are used, the EPDM side must
face upwards.
Position the sealing collar in such a way that the screw holes are
visible through the recesses.
Position the clamping ring on the sealing collar in such a way that
the screw holes are visible through the recesses.
Advantix clamping ring8 from 9
Page 9
3.3Disposal
Handling
Screw the clamping ring tightly to the flange.
Thread in the mounting screws in the screw holes only.
The drain is sealed and the remaining sealing collars can be
ð
laid.
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Advantix clamping ring9 from 9