Viega 4914.11 Instructions For Use Manual

Page 1
Model Year built:
4914.11 from 01/2010
en_INT
Advantix Top bathroom drain
Instructions for Use
Page 2
Advantix Top bathroom drain 2 from 26
Page 3
1 About these instructions for use 4
1.1
Target groups 4
1.2
Labelling of notes 4
1.3
About this translated version 5
2 Product information 6
2.1
Standards and regulations 6
2.2
Intended use 6
2.2.1
Areas of use 6
2.2.2
Media 7
2.2.3
Drainage capacity 7
2.3
Product description 7
2.3.1
Overview 7
2.3.2
Technical data 8
2.4
Information for use 8
2.4.1
Installation variations 8
2.4.2
Sealing 9
2.4.3
Fire protection 13
2.5
Required accessories 13
3 Handling 15
3.1
Assembly information 15
3.1.1
Important note 15
3.1.2
Installation dimensions 15
3.1.3
Tools and materials 15
3.2
Assembly 16
3.2.1
Construction and water seal level 16
3.2.2
Mount base unit 18
3.2.3
Sealing the drain 22
3.2.4
Mounting the top 24
3.3
Care 25
3.3.1
Care tips 25
3.3.2
Cleaning the drain 25
3.4
Disposal 26
Table of contents
Advantix Top bathroom drain 3 from 26
Page 4
1 About these instructions for use
Trade mark rights exist for this document, further information can be found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following groups of people:
n Heating and sanitary professionals and trained personnel n Tilers n Consumers
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
DANGER! This symbol warns against possible life-threatening injury.
WARNING! This symbol warns against possible serious injury.
CAUTION! This symbol warns against possible injury.
NOTICE! This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Advantix Top bathroom drain 4 from 26
Page 5
1.3 About this translated version
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, stand­ards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
About these instructions for use
Advantix Top bathroom drain 5 from 26
Page 6
2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at
viega.com/standards
.
Regulations from section: Sealing
Scope / Notice Regulations applicable in Ger-
many
Stress class of the underground, as well as suitable bonded sealing
ZDB-Merkblatt 8/2012
Stress class of the underground, as well as suitable bonded sealing
Leitfaden zur Abdichtung im Ver­bund (AIV)
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A and AO
ETAG 022 T1
Approved bonded sealings with proof of practicability in keeping with building law for stress classes A, B and C
DIBt-Bauregelliste A, Teil 2 des DIBt und Prüfgrundsätze für Abdichtungen im Verbund (PG AIV-F)
Permitted bonded sealings EN 14891
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
many
Typical domestic wastewater DIN 1986-3
2.2 Intended use
2.2.1 Areas of use
The drain is designed for small to medium volumes of water, which occur in e. g. residential building.
Technical information, see
Ä Chapter 2.3.2 „Technical data“ on page 8
.
Product information
Advantix Top bathroom drain 6 from 26
Page 7
2.2.2 Media
n The short-term temperature of the wastewater may reach up to
95° C. The temperature must be considerably lower in constant operation.
n The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the product material.
2.2.3 Drainage capacity
The drainage capacity is dependent on the chosen installation height. The drainage capacity is 0,95 l/s up to 1 l/s with horizontal DN 50 drain
support..
2.3 Product description
2.3.1 Overview
1
2
3
5
7
4
6
Fig. 1: Scope of delivery model 4914.11
1 - top with grate, can be cut to length 2 - plug-in adapter for top 150 mm 3 - immersion pipe 4 - flange for the application of the conventional sealing
Product information
Advantix Top bathroom drain 7 from 26
Page 8
5 - base unit 6 - floor piece 7 - clamping ring
2.3.2 Technical data
Nominal width [DN] (drain support)
50
Drainage capacity
Ä Chapter 2.2.3 „Drainage capacity“ on page 7
Dimensions and installa­tion height
Ä Chapter 3.1.2 „Installation dimen­sions“ on page 15
Water head seal 35 up to 50 mm
Load class K = 300 kg
2.4 Information for use
2.4.1 Installation variations
The mounting of the drain in a bare concrete floor is as follows:
n
The drain is placed in a floor recess and then cast-in.
Installing in a bare concrete floor
Fig. 2: General installation example – Floor recess
Product information
Advantix Top bathroom drain 8 from 26
Page 9
During the mounting on the floor, the drain is integrated into the floor construction. At the same time, it can e. g. be integrated into the level­ling screed or heat insulation. If necessary, a vertical drainpipe can be led through a drill hole in the floor at the same time.
NOTICE! The creation of a floor recess must be agreed with the fol­lowing people:
– a structural engineer – the on-site fire protection inspector or the specialist
engineer for fire protection
If necessary, proof of compliance with building code or an expert's report must exist.
2.4.2 Sealing
The drain can be sealed both conventionally as well as with bonded sealing.
Depending on the type of sealing, you will require the relevant equip­ment set
Ä Chapter 2.5 „Required accessories“ on page 13
.
Mounting on a floor
Fig. 3: General mounting example – Mounting on the floor
Product information
Advantix Top bathroom drain 9 from 26
Page 10
The flange of the drain is intended for conventional sealing. To be able to seal the drain conventionally, you require a suitable sealing collar and a clamping ring with which the cuff is secured
Ä Chapter 2.5 „Required
accessories“ on page 13
.
Fig. 4: Construction diagram of a conventional sealing
NOTICE! Not suitable for floor-level showers
Conventional sealing is not recommended with floor-level showers, because dampness can enter the screed and damp proof layer.
The bonded sealing should be used in the case of floor­level showers.
Principle Traditionally, sealing is made using bitumen or EPDM sealing collars.
The sealing collars are laid directly onto the raw concrete or heat insula­tion. This process has proved itself to be particularly effective for sealing balconies, patios, floor installation panels and cellar floors. In addition, sealing collars are often used as an additional second sealing layer below the bonded seal.
The following components are required for the installation of a drain with conventional sealing:
n
Drain
n Clamping ring with sealing collar for EPDM and bitumen sealing
lanes Information for processing The sealing collar is coated with EPDM on the one side and with
bitumen on the other side Place the sealing collar on the drain and fasten it with the flange. It
depends on the sealing collar used which material layer of the sealing collar is placed facing up. You can find more information in the mounting instructions of the sealing flange.
Conventional sealing
Product information
Advantix Top bathroom drain 10 from 26
Page 11
To protect against moisture penetration, apply sealing foils, which are to be processed in liquid state, directly below the tiles on screed and walls. The determination of the stress class and the underground as well as the selection of the suitable bonded sealing must be carried out in compliance with the valid standards and regulations, see: linktarget [Normen
EWT] doesn't exist but @y.link.required='true'.
Bonded sealing can be carried out with the help of a suitable stacking element. You have the possibility to double seal, using conventional and bonded sealing or only using bonded sealing.
Fig. 5: Diagram of a bonded seal with stacking element
Bonded sealing
Product information
Advantix Top bathroom drain 11 from 26
Page 12
Careful planning is required for professional sealing. In addition, depending on the individual dampness wear class and the type of foun­dation, a suitable BS system with a building regulations certificate of suitability must be chosen.
Furthermore, the following factors should be taken into account:
n Drain or shower channel must be equipped with a special flange,
which has an adhesive surface and a width of at least 30 mm.
n For bridging the material change from drain to screed, either a suit-
able sealing collar or sealing tape designed for overlapping with the
BS over a width of at least 50 mm must be used.
n The screed must be laid at a minimum incline of 1–2 %. n The installation must be carried out properly in acc. with the
mounting instructions and the manufacturer's information.
1
9 8 7 6
2 3 4 5
Fig. 6: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 - Grate 2 - Top piece with adhesive flange 3 - Tile 4 - Tile cement 5 - Bonded sealing 6 - Screed 7 - Sealing collar 8 - Mat 9 - Adhesive flange
In connection with suitable drains, only approved bonded sealings with proof of practicability in keeping with building law may be used. See link-
target [Normen EWT] doesn't exist but @y.link.required='true'.
Information regarding the procedure can be found in the instructions for use of the corresponding product.
Important note
Permitted bonded seals
Product information
Advantix Top bathroom drain 12 from 26
Page 13
2.4.3 Fire protection
Advantix shower channels and drains can both be fitted to be fire proof. The R120 pipe lead-in can be used for this purpose in the floor con­struction. In this way, a fire resistance time of up to 120 minutes can be achieved.
Fig. 7: Example: fire protection pipe lead-in
Mounting instruction of the R120 pipe lead-in see model 4923.5, Art.-No. 491 673.
2.5
Required accessories
Advantix tops are available in a number of sizes and variations. You can also only buy an Advantix top frame and then purchase a suitable designer grate separately (see catalogue).
Top
Product information
Advantix Top bathroom drain 13 from 26
Page 14
The drain can be fitted with a sieve insert (model 4923.1) to collect dirt.
If a conventional sealing is to be made, a suitable sealing collar and a clamping ring will be required.
You will find a corresponding set in the catalogue (model 4998.3).
If a bonded sealing is to be applied, a suitable stacking element with sealing collar is required.
You will find a corresponding set in the catalogue (model 4994).
Sieve insert
Accessories for the conventional sealing
Accessories for the bonded sealing
Product information
Advantix Top bathroom drain 14 from 26
Page 15
3 Handling
3.1 Assembly information
3.1.1 Important note
Before assembly:
n Check if the drainage capacity of the drain is sufficient for the arising
water volume linktarget [Ablaufleistung] doesn't exist but @y.link.required='true'.
n Check if the installation height of the drain corresponds with the
planned floor construction.
n Ensure that the required connection line is installed with the neces-
sary incline to the planned installation location.
n If necessary, supply the required accessories
Ä Chapter 2.5
„Required accessories“ on page 13
.
During assembly:
n Observe installation dimensions. n Decide whether or not a backflow seal is required in the insertion
part of the top. After assembly:
n The drain flange must be fully lined with mortar.
3.1.2 Installation dimensions
Fig. 8: Dimensional drawing model 4914.11
3.1.3 Tools and materials
n if necessary, sealing collar, clamping ring, fitting screws n Top with grate, if not included in scope of delivery n if necessary, stacking element for bonded sealing model 4944 n Material for securing the drain
Required material
Handling
Advantix Top bathroom drain 15 from 26
Page 16
3.2 Assembly
3.2.1 Construction and water seal level
Determine screed height.
At a desired installation height of ≥ 110 mm upper edge sealing flange the floor piece remains in the delivery condi­tion.
The water seal level is 50 mm and the immersion pipe length 48 mm.
Loosen clamping ring with screwdriver.
Remove clamping ring and push floor piece in by one ring (1 x 10 mm).
Installation height 101–110 mm
Handling
Advantix Top bathroom drain 16 from 26
Page 17
Align the floor in such a way that the arrows point towards the drain pipe.
Secure floor with clamping ring. Tighten the screw of the clamping ring with max. 2.5 Nm ±0.2 Nm.
Alternatively, tighten the end of the clamping ring up to or between the markings.
ð
The water seal level is 40 mm and the immersion pipe length 38 mm.
Loosen clamping ring with screwdriver.
Installation height 90–100 mm
Handling
Advantix Top bathroom drain 17 from 26
Page 18
Remove clamping ring and push floor piece in by two rings (2 x 10 mm).
Align the floor in such a way that the arrows point towards the drain pipe.
Secure floor with clamping ring. Tighten the screw of the clamping ring with max. 2.5 Nm ±0.2 Nm.
Alternatively, tighten the end of the clamping ring up to or between the markings.
ð
The water seal level is 35 mm and the immersion pipe length 33 mm.
3.2.2 Mount base unit
A few points must be observed to integrate the drain into the floor con­struction properly. For this reason, proceed as follows to prepare the drain for subsequent work:
Handling
Advantix Top bathroom drain 18 from 26
Page 19
Requirements
n A pipe to the planned drainage position is already in place for the
connection to the waste water system.
n The drain pipe has an internal sealing lip.
Position the drain in the floor and align horizontally. Insert yellow protective plug.
Push the drain support into the drain pipe completely.
Secure the drain in such a way that it cannot shift when the subse­quent works are applied.
Most importantly, it must be ensured that the drain does not float when the concrete or screed is poured in.
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces.
Installing in a bare concrete floor
Installation on a bare concrete floor
Handling
Advantix Top bathroom drain 19 from 26
Page 20
No building seal with sealing collar is possible with this installation method.
Requirements
n A pipe to the planned drainage position is already in place for the
connection to the waste water system.
n The drain pipe has an internal sealing lip.
Position the drain on the floor and align horizontally. Insert yellow protective plug.
Push the drain support into the drain pipe completely.
Calculate FFL and cut top flush to length. Install plug-in adapter with backflow seal. Insert top.
Handling
Advantix Top bathroom drain 20 from 26
Page 21
Secure the drain in such a way that it cannot shift when the subse­quent works are applied.
Most importantly, it must be ensured that the drain does not float when the concrete or screed is poured in.
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces.
Requirements
n A pipe to the planned drainage position is already in place for the
connection to the waste water system.
n The drain pipe has an internal sealing lip.
Position the drain on the floor and align horizontally. Insert yellow protective plug.
Push the drain support into the drain pipe completely.
Installation in a bare concrete floor with levelling screed or heat insulation
Handling
Advantix Top bathroom drain 21 from 26
Page 22
Secure the drain in such a way that it cannot shift when the subse­quent works are applied.
Most importantly, it must be ensured that the drain does not float when the concrete or screed is poured in.
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully lined and that there must be no hollow spaces.
3.2.3 Sealing the drain
NOTICE! Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks may occur when pressure is applied.
Check the proper completion of the subsequent work.
Screed and floor tiles must be laid at an incline of 1–2 % in the direction of the drain.
Requirements:
n A suitable sealing collar and a clamping ring are available. n The flange is free of heavy soil. n The complete surface of the flange is lined with material and undam-
aged.
If required, clean the flange of coarse soil (e. g. from screed).
Conventional sealing
Handling
Advantix Top bathroom drain 22 from 26
Page 23
Insert sealing ring. The sealing ring must lie in the groove between the flange and the
screw holes.
INFO! The Viega sealing collar has two differently coated sides. One side is coated with bitumen and the other side with EPDM. If the additional sealing takes place with bitumen sealing lanes, the sealing collar must be used with the bitumen side facing upwards. If EPDM sealing lanes are used, the EPDM side must face upwards.
Position the sealing collar on the drain. The screw holes must be visible through the recesses.
Position the sealing flange on the sealing collar in such a way that the screw holes are visible.
Screw the sealing flange together tightly with the drain. The fixing screws of the clamping ring may only be screwed into the
screw holes of the drain.
ð
The drain is sealed and the remaining sealing collars can be laid.
Handling
Advantix Top bathroom drain 23 from 26
Page 24
3.2.4 Mounting the top
A top with the grate must still be mounted to finish off the mounting of the drain. Proceed as follows:
If necessary, insert backflow seal in the lowest notch of the top.
INFO! The backflow seal be must employed when no damp­ness is supposed to flow into the drain from outside of the top but water may seep in from below. Normally, no backflow seal is mounted so that water that occurs around the frame (e. g. due to a leaky silicone joint) can flow away. A backflow seal is mounted in the following cases:
– In the case of the risk of a build-up of water that can soak
through the screed.
– During the mounting of a stacking element for the bonded
sealing (see instructions for use of the stacking element).
Calculate FFL and cut top flush to length. Install plug-in adapter. Insert top.
Calculate FFL and cut top flush to length. Install plug-in adapter with backflow seal. Insert top.
Drain in the bare floor
Drain in levelling screed or heat insulation
Handling
Advantix Top bathroom drain 24 from 26
Page 25
3.3 Care
3.3.1 Care tips
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the grate and frame. Under no circum­stances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components.
3.3.2 Cleaning the drain
We recommend using a mild cleaning agent and a washing-up brush for cleaning.
Remove and clean grate.
Remove and clean immersion pipe.
Handling
Advantix Top bathroom drain 25 from 26
Page 26
Clean drain.
Replace immersion pipe. Re-insert grate.
3.4 Disposal
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Handling
Advantix Top bathroom drain 26 from 26