Vido.at AU-G60 Series, AU-G65 Series, AU-G70 Series User Manual

AU-G60,G65 and G70
Series
User Manual English
v2.33
High Speed dome Camera Series
®
CONTENTS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERTANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGSON THE EQUIPMENT.
FCC COMPLIANCE STATEMENT
CE COMPLIANCE STATEMENT
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE EQUIPMENT.
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGHEND TO PROVIDE REASONABLE PROTECTION AGAINST HAMRFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENGERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIREDTO CORRECT THE INTERFERENCEAT HIS OWN EXPENSE.
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.
CAUTION: TO REDUCETHE RISK
OF ELECTRICSHOCK, DO NOT
REMOVE COVER( OR BACK).NO
USER SERVICEABLEPARTS
INSIDE. REFERSERVICING TO
QUALIFIED SERVICE
PERSONNEL
This symbolindicates that dangerous voltage constitutinga risk ofelectric shock ispresent within thisunit.
This symbolindicates that thereare important operatingand maintenance instructions inthe literature accompanying thisunit.
WARNING
CAUTION: BEFORE ATTEMPTING TO CONECT OR OPERATE THIS PRODUCT, PLEASE READ THE LABEL ON THE BOTTOMAND USER'S MANUAL CAREFULLY
Technical specification are subjects to change without prior notice. Manual may contain mistake or print error. All trademarks mentioned belong to their respective owners.
ENGLISH
1. Precaution...................................................... 1
2. Features......................................................... 2
3. Packing list..................................................... 3
4. Installation..................................................... 4
5. Operation....................................................... 11
6. OSD............................................................... 12
Map................................................................ 13
System Setting................................................ 14
Motion, Clear, Password.................................. 15
Camera Setting............................................... 16
Preset, Scan................................................... 17
Platterns, Tours............................................... 18
Zones and Privacy Mask................................... 19
Alarm Setting................................................... 20
7. Protocol Setting............................................... 21
8. Address ID...................................................... 23
9. Specifications................................................. 27
1.PRECAUTION
Refer all work related to the installaion of this product to qualified service
personnel or system installers.
Do not attemp to disassemble the appliance
Handle the appliance with Care
Do not use strong or abrasive detergents when cleaning the appliance body and
transparent cover.
Do not operate the apliance beyond its specified temperature, humidity or power source ratings.
indoor models
Do not point the camera lens directly to sunlight or any strong light source.
Read this user's manual carefully before operating the appliance.
Do not install the camera in other orientation as designed.
Do not touch the Cover with bare hands or any object.
To prevent electric shock,do not remove screws or cover. There are no user­serviceable parts inside. Contact qualified service personnel for maintenance
Do not strike or shake, as this may damage the appliance. It should be protected against extreme pressure, vibration and humidity during transportation and storage. Damages caused by improper transportation avoid the warranty.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent and wipe gently.
Do not use the dome camera in an extreme environment where high temperature or high humidity exists. Use the within -10°C to +50°C(14°F to 122°F) and a humidity below 90%. The input power source is 24VAC, 50/60Hz and requires 1000mA.
Take immediate action whenthe indoor speed dome becomes wet. Turn off the power and refer servicing to qulified service personnel. Moisture may damage the appliance and cause eletric shock.
This will cause permanent damage to the camera and avoids the warranty.
Make sure that local electric safty standard are followed when using or installing the appliance
And do not bend or squeez the sturctiure, as this may damage the mechanic sturcture
of the appliance and avoids the warranty.
These will scratch the serface and affect the image qulaity.
Use the within -20°C to +60°C(-4°F to 140°F) and a humidity below 90%. The input power source is 24VAC, 50/60Hz and requires 2500mA.
outdoor models
Do not expose the indoor model of dome camera to water or moisture, not try to operate it in wet areas.
2.FEATURES
The high speed dome camera series are designed for in- and outdoor video surveillance application. The integrated, motorized pan-tilt mechanic allows user to point the camera to any position( 360° horizontal and 180° vertical). Both series can be equipped with digital zoom camera modules, which provide zooming functon from 18 to 36 times (optical) and advanced image features.
- 360° Pan and 180° Tilt range (90° with auto-image-flip)
- Support most well-known camera modules
- 128 preset points memory (80 can be used for auto tour function)
- 4 pattern tours
-4Scantour
- Basic setup directly from Keyboard.
- Advanced setup through OSD (On Screen Display) menu.
- up to 24 privacy masking zones ( despends on camera module)
- 7 alarm input & 2 output(4input&1outputpre-wired)
- Multi-Protocol through RS485 or coaxial cable.
- Direction Indicator on screen
- Aluminum Alloy structure with high intensity and heat-sinking
- High-precision step-motor for flicker-less image during movement.
-HighResolution with 520TVL and Wide-Dynamic*
- Auto-Focus
- Auto-Iris
- Auto- Brightness control,
- Auto-Balance
- IR cutter control, Day-Night mode switching.
- Auto Slow-Shutter
depends on camera module type.
G60-G70 series
- Alarm notification will be displayed once the inner temperature exceeds the limit
- In low temperature area, the dome camera will only start after the operation temperature is reached.
- Cooling fan activity is managed by the CPU ( extends the duration)
- Proportional pan for Focus / Speed on different zoom factor.
- Auto-resuming user-defined action, such as tour, pattern or scan after selectable idle
time.
- Power-up Action activates tour or pattern by default.
Key features:
Camera Features:
*
Temperature monitoring and protection
Other features:
12
ENGLISH
Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details Some productsmay not beavailable in yourcountry, please contact ourdistributor for moredetails
3.PACKING LIST
Safety Instructions before starting
- Do not install and operate this appliance in a flammable and explosive environment.
- Make sure that the installation is done according to the local electricity safety regulation of your country.
.
- Before installation and mentainence, make sure that the appliance is disconnected from the power source.
- Do not use any power source other than 24V AC, in order to prevent damages to this device. For details, please refer to the section "Precaution" in previous chapter for more details.
- Handle the device during the installation carfully. Falls or extreme vibration may cause irrepairable damages and avoid the warranty.
- Do not install or operate the appliance near any high-voltage devices or high-voltage cable. The safety distance should remain at least 50 m.
- To archive best image quality, its recommanded to use underground cable shielded with steel tube. Do not install the cable without any protection.
- In a thunderstorm area or region with high inductive voltage, such as high voltage transformer stations, it is necessary to use additional lighning-proof equipments or lightning rob for protection.
- For outdoor installation, lightning-proof and grounding of the device should be considered. Please refer to the industrial saftey regulation and request of your country
.
- Grounding of the appliance should consider anti-interference and fulfill the saftey requirements. Do not connect the ground with short-circuited or other high-voltage electric network.
- The resistance of down conductor should not exceed 4 Ohm, and its thickness should be at least 25mm²
- This appliance has the lightning-proof function which can prevent damages caused by high-voltage pulse, such as lightning strike below 1500.
- This appliance meets the Ip66 standard for water and dust proof. Do not install the in­door model for out-door application which is not designed with water protection. Make sure that the installation is protected from long-time water-drop or spatter, which may damage the appliance.
- Make sure that the enviroment of installation meets the requirement of the appliance, such as holding the weight, enough spaces for bracket and power supply.
4.INSTALLATION
WARNING: The transparent cover part is sensitive and should
be handledwith care. Donot touch orrub the surfacein any way with theprotection foil.Inproper cleaningmethod will cause permanent scratcheson the coverand cause unclearimage or focusing errorof the camera.For Cleaning thecover, please replace theoriginal first withthe spare cover, and wash it by diving intowarm water withnon-corrosive cleaning solution.
34
ENGLISH
G60-S Indoor
Instruction and operation manual 1 piece
AU-G65 AU-G70
USER'S
M
ANUAL
HighSpeeddome
CameraSeries
www.vido-europe.com
G60 Core Unit 1 Piece
Indoor Roof-Mount base platte 1 piece
G65-S Indoor
G65 Core Unit 1 Piece
Indoor Roof-Mount base platte 1 piece
Instruction and operation manual 1 piece
G70-W Outdoor
G70 Core Unit 1 Piece
Out-Door housing with sun.shieldand
cover
1 piece
Spare dome
cover1 piece
Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details
G60-W Outdoor
Out-Door housing with sun.shieldand
cover
1 piece
G60 Core Unit 1 Piece
Instruction and operation manual 1 piece
AU-G65 AU-G70
USER'S
M
ANUAL
HighS
peeddome
CameraSeries
www.vido-europe.com
AU-G65
AU-G70
USER'S
M
ANUAL
HighSpeed
d
ome
CameraSeries
www.vido-europe.com
Instruction and operation manual 1 piece
AU-G65 AU-G70
USER'S
M
ANUAL
High
S
peed
d
ome
CameraSeries
www.vido-europe.com
4.INSTALLATION
Connector description
The wiring cable of provides connectors for power supply, video and I/O interface
G60-G70 series
Power Connector
RS 485 Connector RJ-11
Video output BNC
Alarm I/O
RED : AC 24V BLACK : AC 24V
To power supply
YELLOW : RS485 ­GREEN : Rs485 +
To keyboard or DVR devices for telemetric control
RED : Alarm input 1 PINK : Alarm input 2 YELLOW : GREEN : BLACK : COM GRAY : N.A WHITE : Alarm output - N.O BLUE : Alarm output - N.C
Alarm input 3 Alarm input 4
I/O interface to additional alarm sensor or control devices
Inner Conn : Signal + Outer Conn : Ground
Video Output to monitor or DVR
Using optional accessories
The G60-G70 series speed dome cameras can be connected to various optional accessories through the standard connector types, which simplifiy the cable handling and avoids possible mistakes. All accessories are tested for max. compatibility and best performance.
AU-WP20
Outdoor poweradaptor box AC 230Vto AC 24V
AC 24Power
supply
RS 485
Alarm I/O
AC 230V Power input
AU-S20
Indoor poweradaptor AC 230Vto AC 24V
AU­S20
AC 230V
Power input
AC 24Power supply
AU-KB3N
3-Axis keyboard
controller
RS 485
Telemetriccontrol camera setup
AU-JD2028
21”High Res. security Monitor.
AU-DVRH-16/400
Professional Real-time 16 ChannelDVR
Video signal
RS485 cable
The telemetric control of the appliance uses RS485 serial communication with half­duplex transmission technology.
Depends on the cable typeand baud rate, the transmission distance could vary.The following table shows max. distances based on cable with 0,56mm (24AWG) twisted pair:
2400 bps
1100 m
700m
4oom
4800 bps
1700m
9600 bps
19200 bps
Baud Rate
Max. Distance
Due theenvironmental interferences, suchas eletromagnetic andinduction fields, ornumber of connected applianceon the RS485bus, the transmission rangemay be less,e.g with cablethinner than than 24AWG.
4.INSTALLATION
56
ENGLISH
KB3N
Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details Some productsmay not beavailable in yourcountry, please contact ourdistributor for moredetails
4.INSTALLATION
4.INSTALLATION
Video Cable
Coaxial cable with 75 impedance with copper conductor at center conductor, and shielded with 95% copper.The following table shows different cable type and its maximum length:
Ω
The values are for reference only. Depends on the cable quality and environmental condition, the transmission distance might be less.
RG6/U
Cable standard
RG 11 /U
229m /750 ft
Max. Distance (m /ft)
305m/ 1000ft
457m /1500 ft
RG 59/U
G60-G70 series speed domes provide integrated termination switch. It should be turned on when the dome is installed as the last device. If the controller keyboard is used such as AU-KB3N, you need also to turn on the termination on it. please refer to the keyboard’s manual for details.
RS485Termination
Devices using RS485 control are usually connected in daisy-chain. which reqiuers termination with 120 resistor on both ends. Following picture illustrates the connection methods. please note that a daisy-chain connection type shall not exceed 7 meters.
Ω
120
Ω
Resistor
Device 2 Device 3Device 1
120
Ω
Resistor
RS 485+
RS 485-
HowtoturnonterminationonG60
The termination switch is located on the rear side of the connection board.
Star-Connection
The star-form connection is mostly used. it enables the connection of different dome cameras in longer distance. It is recommended to use RS485 distributor (e.g AU-VC­MC2088) to ensure the telemetric data transmission:
The advantage of star-connection is that every channel can work independently and take a cable length up to 1000 meters( depends on cable quality). In case more dome camera are installed, the star­connection can be extended with additional RS485 distributors.
Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details Some productsmay not beavailable in yourcountry, pleasecontact our distributorfor more details
7
8
ENGLISH
KB3N
12345678910
ON
ID address
When No. 10 bit if the Dip is set to “ON”, the 120 termination resistor is connected. The No. 10 bit if the Dip should be set to “ON” for the last speed dome connected to RS485 communication line.
W
RS 485+
RS 485-
Terminationon
Termination on
Termination off
Termination off
AU-KB3N
KB3N
Terminationon
AU-KB3N
AU-MC2088
RS-485 Distributor
RS485 cable up to1000m per channel
Termination activated on every end.
HowtoturnonterminationonG65andG70
The termination switch is located on the rear side of the connection board. For switching on, you need to open the
123
Term.Off ( default)
Term.On
123
ON
ON OFF
OFF
ON
ON
Jumper
Termination Jumper
rear side
How to open the connector board
The connector board can be easily opened by holding the metal clip and pull.
Press the metal clip in and pull the board on this direction.
Metal Clip holder
Loading...
+ 12 hidden pages