Vidikron VP-5000 User Manual

Page 1
OWNER’S OPERATING MANUAL
HIGH DEFINITION PLASMA DISPLAYS
Models VP-5000 and VP-5000a
Page 2
Page 3
For Plasma Displays
Congratulations on your purchase of a Vidikron video product and welcome to the Vidikron family! With proper installation, setup and care, you should enjoy many years of unparalleled video performance.
This is a LIMITED WARRANTY as defined in the Magnuson-Moss Warranty Act. Please read it carefully and retain it with your other important documents.
WHAT IS COVERED UNDER THE TERMS OF THIS LIMITED WARRANTY:
SERVICE LABOR: Vidikron will pay for service labor by a Vidikron Authorized Service Center when needed as a result of a manufacturing defect for a period of three (3) years from the effective date of delivery to the end user (excluding the plasma glass panel).
PARTS (not including plasma glass panel): Vidikron will provide new or rebuilt replacement parts for the parts that fail due to defects in materials or workmanship for a period of three (3) years from the effective date of delivery to the end user. Such replacement parts are then subsequently warranted for the remaining portion (if any) of the original warranty period.
PLASMA GLASS PANEL: Vidikron will pay for service labor by a Vidikron Authorized Service Center when needed as a result of a manufacturing defect for a period of one (1) year from the effective date of delivery to the end user. In addition, Vidikron will provide new or rebuilt replacement parts for the parts that fail due to defects in materials or workmanship for a period of one (1) year from the effective date of delivery to the end user. Such replacement parts are then subsequently warranted for the remaining portion (if any) of the original warranty period.
Y
WHAT IS NOT COVERED UNDER THE TERMS OF THIS LIMITED WARRANTY:
Image burn-in on plasma display panels is specifically excluded from coverage under this Limited Warranty. Image burn-in is the result of misuse of the product and therefore cannot be repaired under the terms of this Limited Warranty.
Normal viewing material such as television/satellite broadcasts, videotape or DVDs (not put into pause for extended periods of time) will not cause damage to your display under normal conditions. Many DVD players are also equipped with screen savers for this reason.
TO AVOID IMAGE RETENTION (Burn-in): Please ensure that still images are left on your plasma display panel for no more than a few minutes. Also ensure that images displayed in the 4:3 aspect ratio mode (black or gray stripes, but no picture information is present on the left and right edges of the screen) are used as infrequently as possible. This will prevent permanent image burns on your plasma display panel, which can be seen permanently under certain conditions once burn-in has occurred.
The types of images to avoid include video games, still images and computer screens with stationary tool bars and icons. (This is why computers are equipped with screen savers – to prevent still images from burning into the monitor’s phosphors after being displayed continuously for an extended period of time).
This Limited Warranty only covers failure due to defects in materials and workmanship that occur during normal use and does not cover normal maintenance. This Limited Warranty does not cover cabinets or any appearance items; failure resulting from accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper installation or setup adjustments; improper maintenance, alteration, improper use of any input signal; damage due to lightning or power line surges, spikes and brownouts; damage that occurs during shipping or transit; or damage that is attributed to acts of God. In the case of remote control units, damage resulting from leaking, old, damaged or improper batteries is also excluded from coverage under this Limited Warranty.
PRE
IMINAR
L
Vidikron PlasmaView Owner’s Operating Manual iii
Page 4
CAUTION: THIS LIMITED WARRANTY ONLY COVERS VIDIKRON PRODUCTS PURCHASED FROM VIDIKRON AUTHORIZED DEALERS. ALL OTHER PRODUCTS ARE SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS WARRANTY. MOREOVER, DAMAGE RESULTING DIRECTLY OR INDIRECTLY FROM IMPROPER INSTALLATION OR SETUP IS SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED WARRANTY. IT IS IMPERATIVE THAT INSTALLATION AND SETUP WORK BE PERFORMED ONLY BY AN AUTHORIZED VIDIKRON DEALER TO PROTECT YOUR RIGHTS UNDER THIS WARRANTY. THIS WILL ALSO ENSURE THAT YOU ENJOY THE FINE PERFORMANCE OF WHICH YOUR VIDIKRON PRODUCT IS CAPABLE WHEN INSTALLED AND CALIBRATED BY VIDIKRON AUTHORIZED PERSONNEL.
RIGHTS, LIMITS AND EXCLUSIONS:
Vidikron limits its obligations under any implied warranties under state laws to a period not to exceed the warranty period. There are no express warranties. Vidikron also excludes any obligation on its part for incidental or consequential damages related to the failure of this product to function properly. Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. So the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
EFFECTIVE WARRANTY DATE:
This warranty begins on the effective date of delivery to the end user. For your convenience, keep the original bill of sale as evidence of the purchase date.
IMPORTANT – WARRANTY REGISTRATION:
Y
Please fill out and mail your warranty registration card. It is imperative that Vidikron knows how to reach you promptly if we should discover a safety problem or product update for which you must be notified.
IMINAR
L
CONTACT A VIDIKRON AUTHORIZED SERVICE CENTER TO OBTAIN SERVICE:
Repairs made under the terms of this Limited Warranty covering your Vidikron video product will be performed at the location of the product, during usual working hours, providing location of product is within normal operating distance from a Vidikron Authorized Service Center. In some instances it may be necessary for the product to be returned to the Vidikron factory for repairs. If, solely in Vidikron’s judgment, location of product to be repaired is beyond normal operating distance of the closest Vidikron Authorized Service Center, or the repair requires the unit be returned to the Vidikron factory, it is the owner’s responsibility to arrange for shipment of the product for repair. These arrangements must be made through the selling Vidikron Dealer. If this is not possible, contact Vidikron directly for a Return Authorization number and shipping instructions. Vidikron will return product transportation prepaid in the United States, unless no product defect is discovered. In that instance, shipping costs will be the responsibility of the owner.
COPYRIGHT AND TRADEMARKS:
© Copyright 2007 Vidikron, a Runco International Company. This document contains proprietary information protected by copyright, trademark and other intellectual property laws. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic or other means, in any form, without prior written permission of the manufacturer.
Vidikron, Vision, DVSI, Imagix, CineWide, AutoScope, V2 Aperture Control, CSMS and IntelliWide are trademarks of Runco, LLC. All other trademarks and registered trademarks used in this document are the property of their respective owners.
PRE
Vidikron products are manufactured under one or more of the following patents: US. Patent 6755540 and Other Patents Pending.
iv Vidikron PlasmaView Owner’s Operating Manual
Page 5
ADDITIONAL INFORMATION:
To locate the name and address of the nearest Vidikron Authorized Service Center, or for additional information about this Limited Warranty, please call or write:
VIDIKRON
Attn: Customer Service Department
2900 Faber Street
Union City, CA 94587
Ph: (510) 324-5900
Fax: (510) 324-5905
Toll Free: (888) 4VIDIKRON
VIDIKRON PRODUCT INFORMATION
RETAIN THIS INFORMATION FOR YOUR RECORDS
Y
IMINAR
_________________________________________________________ ________________________________________
L
Model Purchased Date
____________________________________________________________________________________________________________
Serial Number
____________________________________________________________________________________________________________
Vidikron Authorized Dealer Name
____________________________________________________________________________________________________________
PRE
Address
____________________________________________ __________________ ________________________
City State/Province Postal Code
____________________________________________ _______________________________________________________
Phone Fax
Vidikron PlasmaView Owner’s Operating Manual v
Page 6

Safety Precautions

Thank you for your purchase of this quality Vidikron video product! It has been designed to provide you with the quality of video that is expected in a home theater. For the best performance, please read this manual carefully as it is your guide through the menus and operation.
WAR NING
CAUTION
RISK OFELECTRIC SHOCK
DO NOTOPEN
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
CAUTION
To turn off main power, be sure to remove the plugs from power outlets. The power outlet socket should be installed as near to the equipment as possible, and should be easily accessible.
WAR NIN G
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO DO NOT USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS, UNLESS THE PRONGS CAN BE FULLY INSERTED. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH-VOLTAGE COMPONENTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WAR NIN G
CAUTION:
SERVICE PERSONNEL.
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Y
IMINAR
L
This equipment has been tested and found to comply with the limits for a Class ‘B’ digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation Manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the user will be required to correct the interference at his own expense.
DOC Compliance Notice
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Please read and follow the safety precautions listed below to ensure the equipment is free from damage, and to ensure that no injury will occur as a result of improper use.
• Do not insert any object, especially metal or liquids, into the plasma display.
• Do not place any objects containing water or any other liquid on top of the plasma display.
• Do not place the units in direct sunlight, near heaters or in extremely dusty or humid locations.
• Do not install this system outdoors or otherwise exposed to the elements.
• Do not place heavy objects on top of the plasma display.
• If the power cord is damaged or frayed in any way, electrical shock and/or fire may result. Do not place objects on the power cord, and keep the cord away from heat-emitting devices. Should the power cord become damaged in any way, please contact your Vidikron Dealer for a replacement cord.
• Do not remove the cover of the plasma display for any reason. If any problems arise with the unit, please contact a Vidikron Dealer or Vidikron for service. Removing the covers will void the warranty.
PRE
vi Vidikron PlasmaView Owner’s Operating Manual
Page 7
1Table of Contents
THREE YEAR LIMITED WARRANTY .......................................................................................... iii
Safety Precautions ................................................................................................................... vi
1. Introduction ........................................................................................................................ 1
About This Manual ............................................................................................................................................ 1
Target Audience......................................................................................................................................... 1
If You Have Comments About This Manual... .................................................................................. 1
Textual and Graphic Conventions ....................................................................................................... 1
Using This Manual ............................................................................................................................................. 2
Description, Features and Benefits ............................................................................................................. 3
Key Features and Benefits....................................................................................................................... 3
Parts List ....................................................................................................................................................... 4
2. Controls and Functions ...................................................................................................... 5
PlasmaView at a Glance .................................................................................................................................. 5
Controls and Indicators ........................................................................................................................... 5
Connectors .................................................................................................................................................. 6
IMINAR
Y
PlasmaView Remote Control ......................................................................................................................... 8
3. Installation ........................................................................................................................ 11
Remote Control ................................................................................................................................................ 11
PRE
Quick Setup ....................................................................................................................................................... 13
Installation Considerations ..........................................................................................................................14
Connections to the PlasmaView ................................................................................................................17
L
Notes on Batteries ................................................................................................................................... 11
Notes on Remote Control Operation................................................................................................ 11
High-Altitude Operation .......................................................................................................................14
Mounting the PlasmaView on a Wall or Table Stand.................................................................. 14
Ambient Light ........................................................................................................................................... 15
Ventilation .................................................................................................................................................. 15
Other Considerations ............................................................................................................................. 16
Connecting the PlasmaView to Source Components ................................................................ 17
Audio Connections..................................................................................................................................18
RS-232 Controller Connection ............................................................................................................ 19
Cable Management.................................................................................................................................20
Vidikron PlasmaView Owner’s Operating Manual vii
Page 8
Table of Contents
4. Operation .......................................................................................................................... 21
Turning on the Power ....................................................................................................................................21
Setting the PC Display Properties ..............................................................................................................22
Using the On-Screen Menus ........................................................................................................................23
Main Menu ................................................................................................................................................25
Picture Adjust ............................................................................................................................................25
Audio Setup ...............................................................................................................................................32
Image Options .......................................................................................................................................... 32
Install ............................................................................................................................................................ 35
Function ...................................................................................................................................................... 37
Signal Info ..................................................................................................................................................41
5. Maintenance and Troubleshooting ................................................................................ 43
Troubleshooting Tips .....................................................................................................................................43
6. Serial Communications ....................................................................................................45
Y
RS-232 Connection and Port Configuration ..........................................................................................45
Serial Command/Response Messages .....................................................................................................45
Example....................................................................................................................................................... 45
Command List...........................................................................................................................................46
7. Specifications .................................................................................................................... 55
PlasmaView Specifications ........................................................................................................................... 55
PlasmaView Dimensions ............................................................................................................................... 56
Computer/Video Signal Compatibility ....................................................................................................57
IMINAR
L
PRE
viii Vidikron PlasmaView Owner’s Operating Manual
Page 9
1List of Figures
2-1. PlasmaView Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2-2. PlasmaView Connector Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2-3. PlasmaView Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3-1. Available Range of the Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3-2. Ventilation Requirements for Enclosure Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3-3. PlasmaView Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3-4. RS-232 Control System Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3-5. Installing the Cable Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4-1. Attaching the Ferrite Cores to the Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4-2. PlasmaView OSD Menu Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4-3. Typical PLUGE Pattern for Adjusting Brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4-4. Typical Gray Bar Pattern for Adjusting Contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4-5. Typical Color Bar Pattern for Adjusting Color Saturation and Tint . . . . . . . . . . . . . . . . . . . . . . . . 27
4-6. Typical Test Pattern for Adjusting Sharpness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4-7. Zoom Navigation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4-8. Image Freeze Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7-1. PlasmaView Model VP-5000/VP-5000a Dimensions (with Table Stand) . . . . . . . . . . . . . . . . . . . 56
IMINAR
L
Y
PRE
Vidikron PlasmaView Owner’s Operating Manual ix
Page 10
List of Figures
Notes:
Y
IMINAR
L
PRE
x Vidikron PlasmaView Owner’s Operating Manual
Page 11

1Introduction

This Owner’s Manual describes how to install, set up and operate the Vidikron PlasmaView High-Definition Plasma Display (Model VP-5000 or VP-5000a). Throughout this manual, the Vidikron PlasmaView High-Definition Plasma Display is referred to simply as the “PlasmaView.” Except where noted, the information in this manual applies to both PlasmaView models.
most out of the PlasmaView.
Vidikron has made every effort to ensure that this manual is accurate as of the date it was printed. However, because of ongoing product improvements and customer feedback, it may require updating from time to time. You can always find the latest version of this and other Vidikron product manuals on-line, at www.Vidikron.com.
Vidikron welcomes your comments about this manual. Send them to info@Vidikron.com.
Text Conventions: The following conventions are used in this manual, in order to clarify the information and instructions provided:
• Remote control button identifiers are set in upper-case bold type; for example, “Press EXIT to return to the previous menu.”
• Computer input (commands you type) and output (responses that appear on-screen) is shown in monospace (fixed-width) type; for example: “To change the aspect ratio to 16:9, send the command DF 80 60 51 01 05 16.”
• All keys with functional names are initial-capped, set in bold type and enclosed in angle brackets. These keys are the following: <Enter>, <Spacebar>, <Control>, <Esc> and <Tab>.
<Enter> indicates that you may press either the RETURN or ENTER key on your keyboard if it has both keys.
PRE
IMINAR
L
Y

1.1 About This Manual

Target AudienceVidikron has prepared this manual to help home theater installers and end users get the

If You Have Comments About This Manual...

Textual and Graphic Conventions

In addition to these conventions, underlining, boldface and/or italics are occasionally used to highlight important information, as in this example:
WARNING
Vidikron PlasmaView Owner’s Operating Manual 1
To prevent image retention (burn-in) on your display, ALWAYS use a screen saver and set it to the shortest possible time.
Page 12
Introduction
Graphic Conventions: These symbols appear in numerous places throughout the manual, to emphasize points that you must keep in mind to avoid problems with your equipment or injury:
1.2

Using This Manual

Tip
Note
Caution
TIPS highlight time-saving short cuts and helpful guidelines for using certain features.
NOTES emphasize text with unusual importance or special significance. They also provide supplemental information.
CAUTIONS alert users that a given action or omitted action can degrade performance or cause a malfunction.
Y
WARNING
DANGER!
Use the following table to locate the specific information you need in this manual.
WARNINGS appear when a given action or omitted action can result in damage to the equipment, or possible non-fatal injury to the user.
DANGER appears when a given action can cause severe injury or death.
IMINAR
If you need... ... Turn to page:
Information about obtaining service iv
L
General information about the PlasmaView High-Definition Plasma Display
Installation instructions 11
First-time configuration instructions 23
PRE
Advanced configuration instructions 35
Troubleshooting tips 43
Specifications for the PlasmaView High-Definition Plasma Display
3
55
2 Vidikron PlasmaView Owner’s Operating Manual
Page 13
Introduction
Vidikron’s PlasmaView High-Definition Plasma Display is perfect for high-definition viewing. Advanced engineering and design features and state-of-the-art performance make the PlasmaView the ideal choice for those wanting true high definition capability with a resolution of up to 1365 x 768.
The PlasmaView handles all HDTV signals with ease, in addition to standard television. A 16:9 native resolution display panel with advanced engineering innovations gives you the brightest, clearest images possible. Vidikron’s superior video processing with 3:2 film detection circuitry is built into the monitor and provides exceptional detail and artifact-free video enhancement, elevating even standard NTSC material to near-HD quality.
Multiple aspect ratio control includes Vidikron’s IntelliWide™ mode, offering the ability to view standard video formats in widescreen without loss of image quality. IR and discrete RS-232 controls facilitate glitch-free custom installation, while Dynamic Pixel Protection™ helps to protect the plasma panel from stationary image burn.
A generous number of inputs and the sleekest styling around make this flat-panel display monitor a great value and the ideal choice for discerning viewers.
For high-altitude installations, Vidikron also offers the VP-5000a with industry-leading high-altitude compliance to over 9000 feet (2,740 meters) mean sea level (MSL). The VP-5000a shares all other features and specifications with the VP-5000.
• 16:9 Native Resolution: 1365 x 768
• Screen Size (diagonal): 50 inches
• Multiple Aspect Ratios with IntelliWide™ Mode
• Less than 5 inches deep
• Dual HDMI Inputs with High-bandwidth Digital Content Protection (HDCP)
•HDTV Compatible
• Exceptional detail and artifact-free video enhancement
• Superior video processing with 3:2 film detection circuitry
IMINAR
L
Y
PRE

1.3 Description, Features and Benefits

Key Features and BenefitsThe PlasmaView offers these key features and benefits:

Vidikron PlasmaView Owner’s Operating Manual 3
Page 14
Introduction

Parts List Your PlasmaView is shipped with the following items. If any items are missing or damaged,

please contact your Vidikron dealer or Vidikron Customer Service at (888) 4VIDIKRON.
• PlasmaView High-Definition Plasma Display
• AC Power Cord
• Remote Control Unit and two (2), AAA-size batteries
• Warranty information and registration card
• Vidikron PlasmaView Owner’s Operating Manual (this document)
•Ferrite cores (2)
• Cable Clamps
• Wall Mount Kit (part number VIHK-000200)
or
Table Stand (part number VIHK-000250)
• Safety metal fittings
• Screws for safety metal fittings
Note
Use the safety fittings to fasten the PlasmaView to a wall when using the optional tablestand. This prevents tipping due to external shock. Use the supplied screws to fasten the safety fittings to the holes in the back of the plasma.
Y
IMINAR
L
PRE
4 Vidikron PlasmaView Owner’s Operating Manual
Page 15

2Controls and Functions

Figure 2-1 and Figure 2-2 show the locations of the PlasmaView controls, indicators and connectors.
IMINAR

2.1 PlasmaView at a Glance

Controls and Indicators

Y
L
MENU / ENTER
Located on bottom of Plasma
VOLUME
DOWN UP LEFT/- RIGHT/+ /EXIT
INPUT SELECT
Located on bottom of Plasma
PRE
7
Figure 2-1. PlasmaView Controls and Indicators
1. POWER BUTTON
Turns the monitor’s power on and off.
2. REMOTE CONTROL SENSOR
Receives the signals from the remote control.
3. POWER/STANDBY INDICATOR
- Lights red to indicate that the PlasmaView is in standby mode;
- Lights green to indicate normal operation;
- Flashes red to indicate that the internal temperature is too high.
4. INPUT SELECT/EXIT
Press this button to switch inputs, or exit the current menu if an On-Screen Display (OSD) menu is visible.
6
5
4
1
2
3
Vidikron PlasmaView Owner’s Operating Manual 5
Page 16
Controls and Functions
5. LEFT/– and RIGHT/+ These enlarge or reduce the image and function as CURSOR ( / ) buttons in OSD mode.
6. VOLUME DOWN and UP These adjust the volume and function as CURSOR ( / ) buttons in OSD mode.
7. MENU/ENTER Press this button to access the On-Screen Display (OSD) controls. Press this button during the display of the main menu to go to a submenu. Also used to select a highlighted menu item or confirm a changed setting.
The Power on/off switch does not disconnect the plasma display
WARNING
completely from the supply mains.
Y

Connectors

PRE
VIDEO AUDIO
1
2
L
RIGHT
LEFT
+ -
- +
2
4
1
DVD/HD
R
L
(
)
MONO
IMINAR
DVD/HD3DVD/HD
4
AUDIO
3
R
HDMI HDMI
L
(
)
MONO
AUDIO
R
L
EXTERNAL CONTROL
DVD/HD3DVD/HD
3
(
)
MONO
REMOTE
D-SUB
IN OUT
HDMI HDMI
4
1
Y Cb/Pb Cr/Pr
AUDIO
R
L
( MONO
VIDEO AUDIO
1
R
1
L
(
)
2
MONO
2
)
AUDIO
2
DVD/HD
1
R
Y Cb/Pb Cr/Pr
L
(
)
MONO
DVD/HD
2
YCb/PbCr/Pr
DVD/HD
YCb/Pb
PC/RGB
2
D-SUB
Cr/Pr
PC/RGB
D-SUB
EXTERNAL CONTROL
D-SUB
AC IN
1
10
REMOTE
IN OUT
3
5678
Figure 2-2. PlasmaView Connector Panel
6 Vidikron PlasmaView Owner’s Operating Manual
9
Page 17
1. POWER INPUT (100 to 240 VAC) Connect the PlasmaView to power here, using the included power cord.
2. EXTERNAL SPEAKER OUTPUTS Connect optional, external speakers here. Maintain the correct polarity. Connect the (positive) and (negative) speaker wires to the EXT SPEAKER terminals on both the LEFT and RIGHT channels. Please refer to the owner’s manual for your speakers.
3. VIDEO1, 2 (RCA, S-Video) Standard, Composite video and S-Video inputs for connecting a DVD player, satellite receiver, camcorder, laser disc player or Super VHS (S-VHS) VCR.
4. AUDIO1, AUDIO2, AUDIO3 Stereo, RCA-type audio inputs. You can associate each audio input with any video input
-- that is, specify which audio input becomes active when a given video source is selected. For more information, refer to
5. DVD/HD1
DVD/HD2
Standard-definition (480i/576i) or high-definition (720p/1080i), YPrPb component inputs for connecting a DVD player or high-definition TV source.
Audio Setup on page 32.
Controls and Functions
Y
Tip
6. PC/RGB (15-pin D-Sub) Connect an analog RGB signal from a computer or DTV decoder here.
7. DVD/HD3, DVD/HD4 (HDMI) HDCP-compliant digital video input for connecting a DVD player, personal computer or HD tuner with a DVI or HDMI output.
8. EXTERNAL CONTROL (9-pin, male D-Sub) A male, 9-pin D-sub connector for interfacing with a PC or home theater automation/control system.
9. REMOTE IN (3.5-mm mini phone jack, tip/ring/sleeve) Wired input from an external remote control or infrared (IR) receiver.
10. REMOTE OUT (3.5-mm mini phone jack, tip/ring/sleeve) Wired output to the REMOTE IN jack of another device; allows you to control both the PlasmaView and the other device using the same wired remote control.
For best results, do not run your DVD player in progressive mode.
IMINAR
L
PRE
Vidikron PlasmaView Owner’s Operating Manual 7
Page 18
Controls and Functions
2.2

PlasmaView Remote Control

Figure 2-3 shows the PlasmaView remote control, and the paragraphs that follow describe its functionality.
2
1
Y
3
4
6
IMINAR
5
7
8
9
L
12
13
PRE

Figure 2-3. PlasmaView Remote Control

10
11
14
8 Vidikron PlasmaView Owner’s Operating Manual
Page 19
1. IR OUTPUT INDICATOR Lights when a button is pressed to indicate that an IR signal is being transmitted.
2. POWER ON/OFF Use these buttons to turn the PlasmaView on or off. (This does not operate when the POWER/STANDBY indicator of the main unit is off.)
3. CURSOR ( , , , ) Use these buttons to select items or settings, adjust settings or switch display patterns.
4. EXIT Press this button to exit the OSD controls in the main menu. Press this button during the display of a submenu to return to the previous menu.
5. MENU Press this button to access the On-Screen Display (OSD) controls. Press this button during the display of the main menu to go to a submenu. Also used to select a highlighted menu item or confirm a changed setting.
6. VID 1-2 Press this button to select VIDEO 1 as the source. Press it again to select VIDEO 2.
7. DVD-HD 1-4 Press this button repeatedly to select a DVD/HD source.
8. RGB Press this button to select the PC/RGB input as the source.
Controls and Functions
Y
9. ASPECT Press this button to select an aspect ratio. (Not active for all signals.)
10. MUTE Press to mute the audio output. Press it again to restore the sound.
11. VOLUME (+/–) Use these buttons to adjust the audio volume.
12. AUTO OFF Press this button to set the sleep timer. Press it repeatedly to scroll through the available options (30, 60, 90 or 120 minutes; or, select 0 to turn the timer off).
13. DISPLAY Displays the currently-selected aspect ratio and input on the screen.
14. LIGHT Press to illuminate the buttons.
PRE
IMINAR
L
Vidikron PlasmaView Owner’s Operating Manual 9
Page 20
Controls and Functions
Notes:
Y
IMINAR
L
PRE
10 Vidikron PlasmaView Owner’s Operating Manual
Page 21

3Installation

To install batteries in the remote control:
1. Remove the battery cover from the remote control.
2. Insert the two (2), AAA-size batteries included with the remote control. Ensure that the polarities correctly match the markings inside the battery compartment.
3. Replace the battery cover.
and
IMINAR
• Do not mix an old battery with a new one or different types of batteries.
• If you will not use the remote control for a long time, remove the batteries to avoid
damage from battery leakage.
L

3.1 Remote Control

Y

Notes on Batteries• When installing batteries, make sure that the battery polarities are correct.

The remote control can be used to control the PlasmaView within the ranges shown in Figure 3-1.
PRE
Approx.
23 ft (7m)
Figure 3-1. Available Range of the Remote Control
Vidikron PlasmaView Owner’s Operating Manual 11

Notes on Remote Control Operation

Page 22
Installation
• Do not drop the remote control or expose it to moisture or high temperature.
• The remote control may malfunction under a fluorescent lamp. If that occurs, move the plasma display away from the fluorescent lamp.
• Make sure that there is nothing obstructing the infrared beam between the remote control and the IR receiver on the plasma display.
The signal from the remote control can be reflected by walls or other
Note
• If the effective range of the remote control decreases, or it stops working, replace the batteries with new ones.
• Ambient conditions may possibly impede the operation of the remote control. If this happens, point the remote control at the plasma display and repeat the operation.
surfaces.
Y
IMINAR
L
PRE
12 Vidikron PlasmaView Owner’s Operating Manual
Page 23
Installation
Table 3-1 gives a quick overview of the PlasmaView installation process. The sections following this one provide detailed instructions.
Note

Table 3-1. Installation Overview

Step Procedure
1 Mount the PlasmaView on a wall or table stand 14
2 Connect signal sources to the PlasmaView 17
3 Connect external controller to RS-232 port (optional) 19
4 Apply power to the PlasmaView 21
5 If using the PlasmaView with a PC, adjust PC display
properties
6 Display calibration: adjust the following for each input; save
settings when finished:
• Aspect ratio
• Brightness
• Contrast
• Color level
• Tint
• Sharpness
Installation should be performed by a qualified custom video installation specialist.
For Details, refer to
page...
22
25 through 31
IMINAR
L

3.2 Quick Setup

Y
7 Configure audio inputs 32
PRE
Vidikron PlasmaView Owner’s Operating Manual 13
Page 24
Installation

3.3 Installation Considerations

High-Altitude Operation Due to the design of all plasma glass panels made by every manufacturer, and the interaction

Mounting the PlasmaView on
a Wall or
Table Stand
Proper installation of your PlasmaView will ensure the highest possible picture quality. Whether you are installing the PlasmaView temporarily or permanently, you should take the following into account to ensure that it performs optimally.
between ambient air pressure and the plasma gases contained inside of the panel, reliable operation of your plasma display cannot be assured during operation at certain high-altitude locations.
Vidikron has found the VP-5000 to operate reliably at altitudes of up to 6000 MSL (mean sea level). The VP-5000a has been found to operate reliably at altitudes of up to 9000 MSL.
At higher elevations, each panel may react differently, depending upon the altitude, air pressure, humidity and other meteorological factors. If you are planning to use this product at a location above 9000 feet, please contact Vidikron technical support for further information.
To install the PlasmaView, you will need either an optional table stand or wall-mounting kit.
The PlasmaView cannot be installed on its own.
If you do decide to wall-mount the PlasmaView, ensure that the wall-mount bracket is installed according to the instructions included with it. The wall must be capable of supporting a redundant weight factor three (3) times the weight of the display, or be reinforced.
Vidikron recommends that this be done by a custom installation specialist.
Y
IMINAR
Note
L
Use only a Vidikron-approved wall-mount kit or table stand that is specifically designed for your display.
You can attach your optional mounts or stand to the PlasmaView in either of two ways:
• While it is upright.
PRE
14 Vidikron PlasmaView Owner’s Operating Manual
Page 25
• As it lies flat with the screen face down. Place the protective sheet, which was wrapped around the plasma monitor when it was packaged, between the screen and your work surface to avoid scratching or otherwise damaging the screen surface.
images will be noticeably reduced if light directly strikes the display, such as when a shaft of light from a window or floodlight falls on the image. Images may then appear washed out and less vibrant.
on all sides between it and surrounding objects, as shown in disperse, maintaining the proper operating temperature.
Figure 3-2. This allows heat to
Y
Installation

Ambient LightIn general, minimize or eliminate light sources directed at the display. Contrast ratio in your

VentilationIf you are mounting the PlasmaView in an enclosure, leave at least 2 inches (50 mm) of space

Wall
50mm (2")
50mm (2")
(2")
mm
Wall
IMINAR
L
PRE
(2") 50
mm
50
Figure 3-2. Ventilation Requirements for Enclosure Mounting
50mm (2")
Vidikron PlasmaView Owner’s Operating Manual 15
Page 26
Installation

Other Considerations Other considerations and tips that can help improve your installation, avoid damage and

prolong operating life:
• Keep the ambient temperature constant and below 35°C (95°F). Keep the display away from heating and/or air conditioning vents. Changes in temperature may cause drifts in the display circuitry, which may affect performance.
• Keep the PlasmaView away from devices that radiate electromagnetic energy such as motors and transformers. Common sources of these include slide projectors, speakers, power amplifiers and elevators.
• Handle the unit carefully when installing it. When carrying it, use the built-in handles; DO NOT touch or hold the screen face.
• Set the unit away from heat, excessive dust, and direct sunlight.
• Protect the inside of the unit from liquids and small metal objects. In case of accident, unplug the power cord and have it serviced by an authorized Service Center.
• Do not hit or scratch the panel surface as this causes flaws on the surface of the screen.
• For correct installation and mounting it is strongly recommended to use a trained, authorized dealer.
• To avoid sulfurization, it is strongly recommended not to place the unit in a dressing room in a public bath or hot spring bath.
Y
IMINAR
L
PRE
16 Vidikron PlasmaView Owner’s Operating Manual
Page 27
Installation
Proceed as follows to connect the PlasmaView to your video sources, external controller(s) – if present – and AC power.
When connecting your equipment:
• Turn off all equipment before making any connections.
• Use the correct signal cables for each source.
• Ensure that the cables are securely connected. Tighten the thumbscrews on connectors that have them.
• Use the left audio input when connecting mono audio sources.
Connect your video sources to the PlasmaView as shown in Figure 3-3 and described in the sections that follow.
VIDEO 1 / VIDEO 2
AUDIO 1 L/R
DVD/HD1
AUDIO 2 L/R
DVD/HD2
VCR or Laser Disc Player
IMINAR
DVD Player
IBM VGA or
Compatibles
Y
L

3.4 Connections to the PlasmaView

Connecting the PlasmaView to Source Components

PC/RGB
PRE
AUDIO 3 L/R
DVD/HD3
DVD/HD4
EXTERNAL CONTROL (RS-232)
REMOTE IN
REMOTE OUT
Figure 3-3. PlasmaView Connection Diagram
Macintosh or Compatibles
(Desktop type)
Monitor adapter for Macintosh
HD Set Top Box or DVD Player
with HDMI or DVI Output
PC or Automation/Control System
Wired Remote Control
Wired IR Input of Other Equipment
Vidikron PlasmaView Owner’s Operating Manual 17
Page 28
Installation
HDMI Connections: The PlasmaView has two HDMI inputs for connecting a DVD player, DTV decoder or any other device with a DVI or HDMI output. Connect such devices to the DVD/HD3 and DVD/HD4 inputs.
Tip
RGB-HD Connection: Connect your personal computer or DTV decoder with an RGB output to the PC/RGB input on the PlasmaView.
Note
Component Video Connections: If you have a DVD player or DTV decoder with a component (YPbPr) output, connect it to the DVD/HD1 or DVD/HD2 input of the PlasmaView.
Composite/S-Video Connections: The PlasmaView has S-Video (VIDEO2) and Composite (VIDEO1) video inputs for connecting a VCR, camcorder, laser disc player or DVD player.
Use the HDMI inputs whenever possible. This ensures the highest video quality because the signal is carried in the digital domain throughout the entire signal path, from source component output into the display.
1. Refer to Computer/Video Signal Compatibility on page 50 for a list of computer signals compatible with the PlasmaView. Use with signals other than those listed may cause some functions not to work.
2. Some Macintosh computers may require a Macintosh video adapter. Contact your nearest authorized service center or dealer.
3. This PlasmaView may not be able to display images from notebook computers in simultaneous (CRT/LCD) mode. Should this occur, switch the notebook computer to “CRT only” mode. If you are unsure how to do this, refer to your notebook computer’s user manual.
Y
IMINAR
L

Audio Connections Audio Inputs: The PlasmaView has three (3), stereo audio inputs. Connect the audio outputs

from your source components to these inputs.
You can associate each audio input with any video input -- that is, specify which audio input becomes active when a given video source is selected. For more information, refer to Setup on page 32.
PRE
Speakers: The PlasmaView has an internal, 9W per channel stereo amplifier that can drive a pair of stereo speakers. Connect the SPEAKER terminals on both the LEFT and RIGHT channels. Maintain the correct polarity. For more information, refer to the owner’s manual for your speakers.
Audio
(positive) and (negative) speaker wires to the EXT
18 Vidikron PlasmaView Owner’s Operating Manual
Page 29
Installation
Use a 9-pin, “null-modem” (cross-over) RS-232 cable to connect a PC or home theater control/automation system (if present) to the EXTERNAL CONTROL port on the PlasmaView; see
Figure 3-4.
For more information about using this connection, refer to Serial Communications on page 43.
To/From
PC or
Automation/
Control System
(DB-9 or other
connector type,
as required)
3
2
5
8
7
6
4
1, 9
XMT DATA
RCV DATA
SIG GND
CLEAR TO SEND
REQUEST TO SEND
DATA SET READY
DATA TERMINAL READY
NO CONNECTION
* Short 7 and 8 together if the control system does not send RTS.
RCV DATA
XMT DATA
SIG GND
REQUEST TO SEND*
CLEAR TO SEND*
DATA TERMINAL READY
DATA SET READY
1, 9
2
3
5
7*
8*
4
6
DB-9 Female
6
9
Y

RS-232 Controller Connection

1
5
Figure 3-4. RS-232 Control System Connection
PRE
IMINAR
L
Vidikron PlasmaView Owner’s Operating Manual 19
Page 30
Installation

Cable Management To minimize cable clutter, use the cable clamps provided with the PlasmaView to bundle the

video, audio and control cables at the back of the display. Install the clamps as shown in Figure 3-5.
Back of the unit
mounting holes
To attach
1. 2.
clamp
mounting hole
To detach
Y
cables
IMINAR
L
Figure 3-5. Installing the Cable Clamps
PRE
20 Vidikron PlasmaView Owner’s Operating Manual
Page 31

4Operation

1. Turn on your source components.
2. Attach the two ferrite cores supplied with the display to each end of the AC power cable as shown in to a level that conforms to FCC regulations. Use the supplied plastic bands to secure the cores in place.
Power cable

Figure 4-1. Attaching the Ferrite Cores to the Power Cable

3. Plug the female end of the power cord into the AC receptacle on the rear of the PlasmaView (AC 100V ~ 240V). Connect the other end to your AC power source.
4. Press the POWER button on the underside of the PlasmaView (see Figure 2-1). The power indicator lights solid green.
5. After a brief warm-up period (approximately 10 seconds), the PlasmaView will display an image.
Figure 4-1. Doing so will reduce radio frequency interference (RFI) emissions
Y
Ferrite Core
Ferrite Core
IMINAR
L

4.1 Turning on the Power

PRE
Vidikron PlasmaView Owner’s Operating Manual 21
Page 32
Operation
4.2

Setting the PC Display Properties

To maximize image quality when using the PlasmaView with a personal computer, you may need to adjust the display properties of your PC video card. To do this:
1. Choose Settings from the Windows Start menu and click on “Control Panel.”
2. Double click on the Display icon.
3. Click the Settings tab on the display dialog box.
4. Adjust the resolution to 1024x768 pixels.
PRE
IMINAR
L
Y
5. Click the Advanced button and click the Monitor tab on the dialog box. Set the vertical frequency to 60Hz and click OK.
22 Vidikron PlasmaView Owner’s Operating Manual
Page 33
Operation
Note
WARNING
1. The native resolution of the VP-5000 is 1365 x 768. Other horizontal or vertical resolutions may be scaled upward or downward to fit the display.
2. With most computers, you can get the best picture at 1024 x 768 @ 60Hz.
3. The PlasmaView supports 36-bit color (68.7 billion possible colors).
To prevent image retention (burn-in) on your display, ALWAYS use a screen saver and set it to the shortest possible time.
Y
To use the on-screen menus:
1. Press MENU to display the Main Menu.
2. To select a menu item, use the up- or down-arrow buttons ( , ) on the remote control to highlight it.
3. Press MENU to access that menu.
4. Use the up- or down-arrow buttons ( , ) to select the setting you want to change. Then, press MENU.
5. Press the right- or left-arrow button ( , ) to change that setting. (If you do not do this within five seconds, the slidebar disappears.)
6. To return to the previous menu, press EXIT. If the Main Menu is on-screen, pressing EXIT hides the OSD menu.
The PlasmaView OSD menus are arranged hierarchically, as shown in Figure 4-2.
IMINAR
L

4.3 Using the On-Screen Menus

Note
Depending on the selected input source and signal characteristics, some menu options may not be available.
PRE
Vidikron PlasmaView Owner’s Operating Manual 23
Page 34
Operation
Picture Adjust
Audio Setup
Image Options
Memory Setting
Contrast 0 ... 72
Brightness 0 ... 64
Sharpness 0 ... 32
Color 0 ... 64
Tint (R) 0 ... 64 (G)
Video NR
Color Temp.
Cinema Mode On / Off
Image Preset
Gamma 2.1, 2.2, 2.3 or 2.4
Dither (Model VP-5000 only)
Black Level
ICC
Bass 0 ... 13 ... 26
Treble 0 ... 13 ... 26
Balance
Audio Input 1 Video 1, Video 2,
Audio Input 2
Audio Input 3
DVD/HD3 Input
DVD/HD4 Input
Aspect Ratio
V-Shift -64 ... 0 ...+64
H-Shift -128 ... 0 ...+127
V-Size 0 ... 64
H-Size 0 ... 64
Auto Adjust
Fine Picture (only if Auto Adjust = Off)
Picture Adj. (only if Auto Adjust = Off)
Off, Memory 1, Memory 2 ... Memory 6
Off, Video NR1, Video NR2 or Video NR3
5400, 6500, 8500 or 9300K
ISF Day, ISF Night, Standard, Preset 1, Preset 2, Preset 3, Factory
Mode1 or Mode2
Normal, Step 1 or Step 2
Red (Y) 0 ... 32 ... 64 (M)
Green (C) 0 ... 32 ... 64 (Y)
Blue (M) 0 ... 32 ... 64 (C)
Yellow (G) 0 ... 32 ... 64 (R)
Magenta (R) 0 ... 32 ... 64 (B)
Cyan (B) 0 ... 32 ... 64 (G)
Reset
(L) -22, -21 ... 0 ... +21, +22 (R)
DVD/HD1, DVD/HD2, DVD/HD3, DVD/HD4, RGB
Input 1-3 or HDMI
4:3, 16:9, Letterbox,
PRE
IntelliWide, CinemaFill
On / Off (PC/RGB Input only)
0 ... 64 (PC/RGB Input only)
0 ... 128 (PC/RGB Input only)
Language English
DVD/HD1 Input Component
D-SUB Type RGB
HD Type 540p, 1035i or 1080i
RGB Type Auto
HDMI Blk. Level Low or High
Video Standard
Gain Red
Gain Green
Gain Blue
Red Offset
Green Offset
Blue Offset
Reset
Install
Background Black or Gray
Sidebar Lev. (B) 0, 1, 2 ... 15 (G)
S1/S2 Off or Auto
Display OSD O n / Off
OSD Adjust
Y
ID Remote ALL, 1, 2, 3 or 4
Factory On / Off
Advanced OSD On / Off (Note)
Auto Off On / Off
Input Skip On / Off
Sub. Picture
Zoom Nav
Image Freeze
IMINAR
L
Function
Signal Info
Pixel Protect
CC
CC Contrast Level 1 or Level 2
Pwr. On Select
Protocol Set On / Off
V. Freq.
H. Freq.
H. Polarity
V. Polarity
Mode/Memory
Resolution
Auto, 3.58 NTSC, 4.43 NTSC, PAL, PAL-60, PAL-N, PAL-M or SECAM
1 (Top Left) 2 (Top Center) 3 (Top Right) 4 (Bottom Left) 5 (Bottom Center) 6 (Bottom Right)
Sub. P Detect Auto or Off
Display N ormal or Fade
Sub. P Rate 20%, 30% ... 100%
Off, S by S, Btm Left, Btm Right, Top Right, Top Left
Off, S by S1, S by S2, Btm Left, Btm Right, Top Right, Top Left
Auto
Manual - Lum. Setting
Manual - Orbiter Off, Auto1 or Auto2
Manual - Inverse On, Off or White
Manual - Image Sweep
Manual - Soften Off, 1, 2, 3 or 4
Manual - OSD Orbiter On / Off
Manual - OSD Contrast
Off, Caption1, Caption2, Caption3, Caption4, Text1, Text2, Text3 or Text4
Input Select
Volume 0 ... 42
Auto, Level 1, Level 2 or Level 3
On / Off
Level 1 or Level 2
Last, Video 1, Video 2, DVD/HD 1-4 or RGB
Note: Menu items in italics appear only when Advanced OSD is set to On.

Figure 4-2. PlasmaView OSD Menu Structure

24 Vidikron PlasmaView Owner’s Operating Manual
Page 35

Main Menu The Main Menu is the starting point for accessing all PlasmaView functions.

PLASMAVIEW

PICTURE ADJUST

AUDIO SETUP
IMAGE OPT
INSTALL
FUNCTION
SIGNAL INFO.
Operation
Y
picture quality.
The PlasmaView has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Vidikron video display devices. Accordingly, Vidikron recommends that setup and calibration be performed by an ISF-certified installation technician.
All signal types require separate processing. Therefore, you need to calibrate each input separately.
IMINAR
Note
1. When you change a picture quality setting, save the change to an image memory afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for each input and resolution separately.) For information about saving settings, refer to
2. Only brightness and contrast controls are available on the PC/RGB input.
L
Memory Setting on page 31.
PRE
Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Vidikron recommends using the following calibration tools for best results:
• External test pattern source – Ovation Multimedia, Video Essentials or AVIA test DVD (or equivalent).
• A blue filter (provided with many test DVDs), for color level and tint adjustments.
MENU/ENTER
SEL. OK EXIT
Picture AdjustUse the controls in the Picture Adjust menu to calibrate your PlasmaView for optimum
PICTURE ADJUST
MEMORY SETTING : MEMORY 1
CONTRAST : 58
BRIGHTNESS : 56
SHARPNESS : 52
COLOR : 49
TINT : 50
VIDEO NR : OFF
COLOR TEMP. : 6500K
CINEMA MODE : ON
IMAGE PRESET : ISF DAY
GAMMA : 2.2
DITHER : MODE1
BLACK LEVEL : STEP 1
ICC
SEL. ADJ. RETURN
EXIT
EXIT
Connect your test pattern source to the input that you are calibrating and proceed as follows.
Perform the adjustments in the order listed here.
Vidikron PlasmaView Owner’s Operating Manual 25
Page 36
Operation
A
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) pattern.
Figure 4-3 shows a typical PLUGE
Below Black
bove Black
Figure 4-3. Typical PLUGE Pattern for Adjusting Brightness
PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes.
Select Brightness from the Picture Adjust menu. Using the left- and right-arrow ( ) buttons, adjust the brightness so that:
• The darkest black bars disappear into the background.
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
IMINAR
L
PRE
Y
26 Vidikron PlasmaView Owner’s Operating Manual
Page 37
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in
Figure 4-4.
Y
Figure 4-4. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast from the Picture Adjust menu. Using the left- and right-arrow ( ) buttons, adjust the contrast to a point just below which the white rectangle starts to increase in size.
Operation
Note
Color: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-5.
Brightness and contrast controls are interactive. A change to one may require a subtle change to the other in order to achieve the optimum setting.
IMINAR
L
gray
yellow
cyan
green
PRE
magenta
red
blue
Figure 4-5. Typical Color Bar Pattern for Adjusting Color Saturation and Tint
Vidikron PlasmaView Owner’s Operating Manual 27
Page 38
Operation
Select Color from the Picture Adjust menu. While looking at the color bar pattern through a blue filter, adjust the color saturation level until the outermost (gray and blue) color bars appear to be a single shade of blue:
gray
yellow
cyan
green
red
magenta
blue
Y
Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. When tint is decreased, the image appears redder; when it is increased the image appears greener. To set the tint, select Tint from the Picture Adjust menu. While looking at the color bar pattern through a blue filter, adjust the tint level until the cyan and magenta color bars (on either side of the green bar) appear to be a single shade of blue.
IMINAR
L
Note
Like the brightness and contrast controls, the color and tint controls are interactive. A change to one may require a subtle change to the other in order to achieve the optimum setting.
PRE
28 Vidikron PlasmaView Owner’s Operating Manual
Page 39
Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture Adjust menu and press MENU. On your external test pattern source, select a pattern like the one shown in looking for white edges around the transitions from black to gray and different sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them.
Figure 4-6. Adjust as needed,
Y
Operation
IMINAR
Figure 4-6. Typical Test Pattern for Adjusting Sharpness
L
Video NR: To apply Digital Noise Reduction (DNR) to the input signal, select Video NR from the Picture Adjust menu. Noise reduction is useful for clearing up noisy RGB images such as those from a PC.
Use the left- or right-arrow buttons to select the desired amount of noise reduction, keeping in mind that higher settings (which reduce high frequencies) may also “soften” the image.
Color Temp.: To adjust the color temperature, select Color Temp. from the Picture Adjust menu. (Color temperature defines the “color of gray.”) Use the left- and/or right-arrow buttons to select 5400K, 6500K, 8500K or 9300K. The default setting, 6500K, is appropriate for most situations. Higher settings produce a “bluer” picture; lower ones impart a reddish hue to the image.
White Balance: For each color temperature, you can fine-tune the white balance parameters to remove any trace of color from the white areas of the image. To do this, select a color temperature as described above and press MENU. Then:
•Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red, green or blue, decrease the Gain for that color.
• Offset: Use the Offset controls in the White Balance sub-menu to correct color imbalances in the dark areas of the image. A good way to do this is to use a test pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red, green or blue, decrease the Offset for that color.
PRE
WHITE BALANCE
COLOR TEMP. 6500K
RED GAIN : 40
GREEN GAIN : 40
BLUE GAIN : 40
RED OFFSET : 40
GREEN OFFSET : 40
BLUE OFFSET : 40
RESET : OFF
SEL. ADJ. RETURN
EXIT
Vidikron PlasmaView Owner’s Operating Manual 29
Page 40
Operation
To reset the white balance settings to the factory default values, select Reset. Then, press the right-arrow button to select ON and press MENU.
Note
Cinema Mode: When you enable Cinema Mode, the PlasmaView automatically detects and optimizes the display of interlaced video signals that originated from film. To disable Cinema Mode, set it to OFF.
Image Preset: The PlasmaView provides seven image quality presets per input that allow you to quickly change the image settings to suit the viewing environment and/or source material:
• Select PRESET1 or PRESET2 when watching video in a dark room. These settings provide darker, finer pictures, like the screen in movie theaters. For a darker image, select PRESET2.
• Select STANDARD when watching video in a bright room. This mode provides dynamic pictures with distinct differences between light and dark sections.
• The PRESET3 setting is similar to STANDARD but produces a brighter picture.
• The ISF DAY and ISF NIGHT presets are available only when an ISF-certified installation technician installs and calibrates the PlasmaView. Only an ISF-certified technician can modify the settings associated with these presets.
• To reset all image settings to their factory defaults, select the FACTORY preset.
Gamma: The Gamma control determines how gray shades are displayed between minimum input (black) and maximum input (white) for all signals. A good gamma setting helps to optimize blacks and whites while ensuring smooth transitions for the “in-between” values utilized in other grays.
L
You must set the Advanced OSD option (in the Function menu) to ON in order to access the Gamma, Dither, Black Level and ICC settings. Refer to Advanced OSD on page 37.
Y
IMINAR
Unlike brightness and contrast controls, Gamma allows you to lighten or darken the overall tone of your images without changing the extremes. All images will be more vibrant while still showing good detail in dark areas.
The default Gamma setting of 2.2 is appropriate for most typical home theater environments.
PRE
Dither: Dithering can improve detail in some signals, especially in dark areas of an image. Select Dither from the Picture Adjust menu and choose the dither method that is appropriate to the type of source material (MODE1 or MODE2).
Black Level: This control compensates for incoming elevated black levels present in certain video signals, and ensures that blacks in the display are neither “crushed” (where dark grays appear black) nor excessively elevated (where blacks appear dark gray).
By default, the PlasmaView automatically determines the best setting according to the type of incoming video signal. For some types of video, you may want to override the setting. Generally, if black appears crushed when brightness = 32, choose “NORMAL.” If black appears excessively elevated, use “STEP 1” or “STEP 2.”
30 Vidikron PlasmaView Owner’s Operating Manual
Page 41
ICC: Select ICC from the Picture Adjust menu to adjust the hue and color density for each of the six primary colors: red, green, blue, yellow, magenta and cyan. Changing these settings for a primary color alters the hue of that color and affects the gamut (range) of possible colors. For example, changing the value for red moves the color closer to either yellow or magenta, which in turn affects all displayed colors having a red component.
Memory Setting: Choose Memory Setting from the Picture Adjust menu to store the current input and image quality settings in one of six memory locations. These memory locations are global (that is, shared by all inputs). You can recall these settings at a later time, without manually recreating them.
You should save changes to any of the following settings to a picture memory; otherwise they will be lost when a new input source is selected:
• Contrast/Brightness
• Color saturation/Tint
• Sharpness
•Gamma
• Color temperature and white balance
To store settings to a picture memory:
1. Select Memory Setting from the Picture Adjust menu.
2. Use the left- and/or right-arrow buttons to select a memory location (1 through 6).
3. Press MENU on the remote control. The Picture Memory screen appears.
4. Use the left- and/or right-arrow buttons to select SET, then press MENU.
5. If desired, enter a brief note (up to 15 characters long) describing the stored settings. To do this:
a Use the left- and/or right-arrow buttons to select NOTE, then press MENU.
b Use the up- and/or down-arrow buttons to select the character. Use the left- and/or
right-arrow buttons to change the cursor position. Press EXIT to insert a space or delete a character at the current position.
c When you have finished entering the note, press MENU.
To recall a picture memory setting, perform Steps 1 and 2 above.
PRE
IMINAR
L
Y
Operation
ICC
RED : 32
GREEN : 32
BLUE : 32
YELLOW : 32
MAGENTA : 32
CYAN : 32
RESET : OFF
OK
EXIT
EXIT
RETURN
SEL. ADJ. RETURN
MEMORY SETTING
MEMORY1 SET RESET
INPUT : DVD/HD1 SIGNAL : 480P NOTE : DVD/STAR WARS
MEMORY2
INPUT : — SIGNAL : — NOTE : —
MEMORY3
INPUT : — SIGNAL : — NOTE : —
NEXT PAGE
MENU/ENTER
SEL.
1 / 2
Vidikron PlasmaView Owner’s Operating Manual 31
Page 42
Operation
Audio Setup To adjust the bass, treble and left/right balance, or to assign the PlasmaView audio inputs to

AUDIO SETUP

BASS : 0
TREBLE : 0
BALANCE : 0
AUDIO INPUT1 : VIDEO 1
AUDIO INPUT2 : DVD/HD 1
AUDIO INPUT3 : RGB
DVD/HD3 INPUT : HDMI
DVD/HD4 INPUT : HDMI
SEL. ADJ. RETURN
EXIT
the video inputs, select Audio Setup from the Main Menu and press MENU.
Bass: To adjust the low-frequency response, select Bass from the Audio Menu and use the
left- and/or right-arrow buttons to adjust the amount of bass in the audio signal.
Treble: To adjust the high-frequency response, select Treble from the Audio Menu and use the left- and/or right-arrow buttons to adjust the amount of treble in the audio signal.
Balance: To adjust the left/right speaker balance, select Balance from the Audio Menu and use the left- and/or right-arrow buttons to make one channel louder than the other.
Audio Input 1/2/3: This menu lets you assign each audio input on the PlasmaView to a video input. Doing so causes that audio signal to be heard through the speakers when the associated video input is selected.
For example, if a DVD player’s video output is connected to the DVD/HD1 input on the PlasmaView and its audio output is connected to audio input 2, select AUDIO INPUT 2 from the Audio menu. Then, use the left- and right-arrow buttons to assign it to DVD/HD1.
DVD/HD3 Input / DVD/HD4 Input: If you are using these inputs to connect an HDMI-capable component, select HDMI to route the HDMI (digital) audio signal to the speakers when DVD/HD3 or DVD/HD4 is selected.
Select INPUT 1-3 if the HDMI component’s analog audio out is connected to INPUT 1, INPUT 2 or INPUT 3.
Y
Image Options Use the controls in the Image Options menu to perform advanced image quality adjustments

IMAGE OPTIONS

ASPECT RATIO : 16:9
V SHIFT : 0
H SHIFT : 0
V-SIZE : 0
H-SIZE : 0
AUTO ADJUST : OFF
FINE PICTURE : 0
PICTURE ADJ : 0
SEL. ADJ. RETURN
EXIT
PRE
Note
You cannot assign two or more audio inputs to the same video input.
IMINAR
L
and access various other PlasmaView features.
Aspect Ratio: To change the aspect ratio (size and shape) of the projected image, select Aspect Ratio from the Image Options Menu and press MENU. Select the appropriate aspect ratio for the type of program material being viewed; refer to Table 4-1.
32 Vidikron PlasmaView Owner’s Operating Manual
Page 43
Table 4-1. Aspect Ratio Settings
Aspect Ratio Description
16:9 Select 16:9 to view 16:9 DVDs and HDTV
programs in their native aspect ratio.
16:9 Image on
16:9 Screen (Display)
4:3 images are stretched horizontally to fit a 16:9 screen.
Operation
4:3 Image, stretched to fill
16:9 Screen (Display)
4:3 4:3 scales the input signal to fit in the
center of the 16:9 screen. 4:3 is the aspect
4:3 Image on
16:9 Screen (Display)
ratio used by computer monitors, standard television programming and most VHS video cassettes.
IMINAR
Letterbox Letterbox mode scales (zooms in on) a 4:3
4:3 Image on
16:9 Display
(Letterbox aspect ratio)
IntelliWide IntelliWide scales a 4:3 image NON-linearly
PRE
4:3 Image on
16:9 Screen (Display)
L
image linearly (by the same amount on all sides) to fill a 16:9 display. Letterbox is best suited for viewing LaserDisc movies or non-anamorphic DVDs on a 16:9 screen.
(more on the sides than in the center) to fit a 16:9 screen.
Y
4:3 Image on
16:9 Screen
with IntelliWide
Vidikron PlasmaView Owner’s Operating Manual 33
Page 44
Operation
Table 4-1. Aspect Ratio Settings (continued)
Aspect Ratio Description
CinemaFill CinemaFill scales (zooms in on) a 2.35:1
image linearly (by the same amount on all
2.35:1 Image on 16:9 Display
2.35:1 Image on
16:9 Display with
Cinema Fill
sides) to fill a 16:9 display.
This eliminates the black bars above and below the active image area. However, some picture information on the sides is
Y
lost.
V Shift: Use the up- or down-arrow buttons ( , ) to highlight V Position. Then, use the right-arrow button ( ) to shift the image up; use the left-arrow button ( ) to shift the image down.
H Shift: Use the up- or down-arrow buttons ( , ) to highlight H Position. Then, use the right-arrow button ( ) to shift the image to the right; use the left-arrow button ( ) to shift the image to the left.
V Size: Use the up- or down-arrow buttons ( , ) to highlight V Size. Then, use the right-arrow button ( ) to increase the height; use the left-arrow button ( ) to decrease it.
H Size: Use the up- or down-arrow buttons ( , ) to highlight H Size. Then, use the right-arrow button ( ) to increase the width; use the left-arrow button ( ) to decrease it.
Auto Adjust (available only on PC/RGB Input): To have the PlasmaView automatically
PRE
adjust the size, position, and quality of RGB computer images, select Image Options menu and set it to ON. To make these adjustments manually, set Auto Adjust to OFF.
Fine Picture (available only on PC/RGB Input): Use the Fine Picture control to reduce or eliminate flickering in the image.
Picture Adjust (available only on PC/RGB Input): Use the Picture Adjust control to remove striped patterns from the displayed image.
Note
IMINAR
L
Auto Adjust from the
Fine Picture and Picture Adjust are adjustable only when Auto Adjust is set to OFF.
34 Vidikron PlasmaView Owner’s Operating Manual
Page 45
Note
Language: Select Language from the Install Menu, then press or to highlight the desired language and press MENU. The change takes effect immediately.
DVD/HD1 Input: Select DVD/HD1 Input from the Install menu to specify the signal format on the DVD/HD1 input. Currently, the only option is COMPONENT.
D-SUB Type: Select D-SUB TYPE from the Install menu to specify the signal format on the PC/RGB input. Currently, the only option is RGB.
HD Type: Select HD Type from the Install menu to specify the resolution (number of vertical lines) of the incoming high definition signal, if necessary.
• Choose 1080i for standard digital broadcasts.
• Choose 1035i for Japanese “High Vision” TV broadcasts.
• Choose 540p for compatibility with certain HDTV receivers.
You must set the Advanced OSD option (in the Function menu) to ON in order to see all of the items in the Install menu. If you do not, only the Language and Factory menu items are available. Refer to
OSD on page 37.
Advanced
Y
Operation

Install

INSTALL
LANGUAGE : ENGLISH
DVD/HD1 INPUT : COMPONENT
D-SUB TYPE : RGB
HD TYPE : 1080i
RGB TYPE : AUTO
HDMI BLK. LEVEL : LOW
VIDEO STANDARD : 3.58 NTSC
BACKGROUND : GRAY
SIDEBAR LEV. : 3
S1/S2 : ON
DISPLAY OSD : ON
OSD ADJUST : 3
ID REMOTE : 1
FACTORY : ON
SEL. ADJ. RETURN
EXIT
These are the only resolutions that the PlasmaView does not detect automatically.
RGB Type: RGB Type refers to the incoming RGB signal type. Currently, the only option is AUTO.
HDMI Blk. Level: Select HDMI from the Install menu to adjust the black level of the displayed HDMI signal. Set it to LOW if blacks appear elevated (dark gray). If blacks appear “crushed” (too dark), set it to HIGH.
IMINAR
L
PRE
Vidikron PlasmaView Owner’s Operating Manual 35
Page 46
Operation
Video Standard: Select Video Standard from the Install menu to specify the color system for composite video (VIDEO 1) or S-Video (VIDEO 2) input signals.
Different countries use different formats for video signals. Select the appropriate color system for your country:
•AUTO: The color systems are automatically identified and the format is set accordingly.
•PAL: This is the standard format used mainly in the United Kingdom and Germany.
•SECAM: This is the standard format used mainly in France and Russia.
• 4.43 NTSC, PAL60: This format is used for videos in countries using PAL and SECAM video
signals.
•3.58 NTSC: This is the standard format used mainly in the United States and Japan.
•PAL-M: This is the standard format used mainly in Brazil.
•PAL-N: This is the standard format used mainly in Argentina.
Background: Select Background from the Install menu to choose the color (BLACK or GRAY)
that is displayed when no input signal is present.
Y
Tip
Sidebar Lev.: Select Sidebar Level from the Install menu to adjust the gray level for the sides of the screen when the Aspect Ratio is set to 4:3 (refer to (black) to 15 (light gray). The default setting is 3 (dark gray).
IMINAR
S1/S2 (S-Video signals only): If an incoming S-video signal contains screen size information, the PlasmaView can use that information to automatically adjust the image size to fit the screen. To enable this feature, select S1/S2 from the Install menu and set it to AUTO. To disable it, set it to OFF.
Display OSD: When you select an aspect ratio or input with the remote control, the PlasmaView displays your selection on-screen. When you adjust the volume, a slidebar appears as a visual indicator of the level. When you press DISPLAY on the remote control,
PRE
the PlasmaView displays the currently-selected aspect ratio and input on-screen.
To prevent the display of these items, select Display OSD from the Install menu and set it to OFF.
OSD Adjust: To adjust the position of the on-screen menus, select OSD Adjust from the Install menu. The range is from 1 (top left) to 6 (bottom right).
ID Remote: This menu item is reserved for future use.
Factory: To restore the PlasmaView to its factory-default state, select Factory from the Install
menu and set it to ON. “CONFIRM” appears on the screen during the reset, then disappears when the reset is complete.
L
Setting Background to GRAY makes it easier to see whether the display is turned off, or turned on and not receiving a signal.
Table 4-1). The range is from 0
All PlasmaView settings revert to their default values, with the following exceptions:
•Image Options: Aspect Ratio, Computer
• Install: Language, HD Type, HDMI, Color System
36 Vidikron PlasmaView Owner’s Operating Manual
Page 47
power management, pixel protection, closed captioning and others.
Operation
FunctionSelect Function from the Main menu to configure advanced PlasmaView features such as
Note
Advanced OSD: To have access to all PlasmaView menus and settings, select Advanced OSD from the Function menu and set it to ON.
Once the PlasmaView has been installed and calibrated, you may wish to have it display only a subset of its menus, for the sake of simplicity. If so, set the PlasmaView hides the menu items shown in italics in Figure 4-2.
Auto Off: When using the PlasmaView with a computer, select Auto Off from the Function menu and set it to ON. The Auto Off (power management) function automatically reduces the monitor’s power consumption after a period of no input from the keyboard or mouse.
Note
The POWER/STANDBY LED at the front of the PlasmaView indicates the status of the power management function, as described in
You must set the Advanced OSD option to ON to see all of the options in the Function menu.
Advanced OSD to OFF. When you do,
Y
1. If the computer is turned off or not properly connected to the PlasmaView, the system is set to the off state.
2. For instructions on using the computer's power management features, refer to the instructions for your computer.
Table 4-2.
IMINAR
Table 4-2. Power Management Indications
L
Power
management
mode
POWER/
STANDBY
Indicator
Power management
operating status
Description
Turning the picture
back on

FUNCTION

ADVANCED OSD : OFF
AUTO OFF : OFF
INPUT SKIP : OFF
SUB. PICTURE
ZOOM NAV : OFF
IMAGE FREEZE : S BY S1
PIXEL PROTECT : AUTO
CC : OFF
CC CONTRAST : LEVEL 1
PWR. ON SELECT
PROTOCOL SET : OFF
SEL. ADJ. RETURN
EXIT
ON Green Not activated. Horizontal and
vertical
PRE
OFF Red Activated. Horizontal and/or
Input Skip: This setting affects the behavior of the INPUT SELECT button on the PlasmaView.
When set to ON, pressing INPUT SELECT allows you to choose only those inputs on which a valid signal is present. The other inputs are skipped.
Vidikron PlasmaView Owner’s Operating Manual 37
synchronizing signals are present from the computer.
vertical synchronizing signals are not present from the computer.
Picture already on.
Press a key on the keyboard or move the mouse. The picture reappears.
Page 48
Operation
Sub. Picture: Select Sub. Picture from the Function menu to change certain behaviors of the Picture-in-Picture, Zoom or Image Freeze features.
Note
• Sub. P Detect (Picture-in-Picture mode): When you set this to AUTO, the PlasmaView removes the black sub-picture frame from the screen approximately three seconds after the sub-picture input signal is lost in Picture-in-Picture mode. When you set this to OFF, the black frame remains on-screen regardless of the presence or absence of an input signal.
• Display: This item controls the manner in which the sub-window appears when you invoke Picture-in-Picture, Zoom or Image Freeze. FADE causes it to fade in gradually; NORMAL causes it to appear right away, with no transition.
• Sub. P Rate: This item controls the opacity of the sub-window when using Zoom, Image Freeze or Picture-in-Picture. Lower settings allow the main image to show through the sub-window (100% = no show-through).
Zoom Nav: Select Zoom Nav from the Function menu to change the position of the small navigation window that appears when you invoke the Zoom feature. Select BTM LEFT, BTM
RIGHT, TOP LEFT, TOP RIGHT or S BY S. Figure 4-8 shows the effect of each of these
settings.
1. The Picture-in-Picture, Zoom and Image Freeze functions are available only via serial commands or a third-party remote control unit that has been programmed to access these functions. For more information, refer to Section Serial Communications, or contact Vidikron Technical Support .
2. The Zoom function is available only when the Aspect Ratio is set to 16:9 or 4:3.
Y
IMINAR
6,
L
Top Left
Bottom
PRE
Left
Figure 4-7. Zoom Navigation Modes
To hide the navigation window, select OFF. When you do, an icon appears in the center of the screen to indicate that you are in Zoom mode.
Top
Right
S BY S
Bottom
Right
38 Vidikron PlasmaView Owner’s Operating Manual
Page 49
Image Freeze: Select Image Freeze from the Function menu to change the position of the still image sub-window that appears when you invoke Image Freeze. Select BTM LEFT, BTM
RIGHT, TOP LEFT, TOP RIGHT, S BY S1 or S BY S2. Figure 4-8 shows the effect of each of
these settings.
Operation
Top Left
Bottom
Left
Figure 4-8. Image Freeze Modes
To disable Image Freeze altogether, select OFF.
Pixel Protect: Select Pixel Protect from the Function menu to configure the image burn-in prevention settings on the PlasmaView.
Set Pixel Protect to AUTO to have the PlasmaView use the following settings:
• Lum. Setting: AUTO
•Orbiter: AUTO1
•Inverse: OFF
• Image Sweep: OFF
• Soften: OFF
• OSD Orbiter: ON
• OSD Contrast: LEVEL 1
To customize these settings, set Pixel Protect to MANUAL and refer to the following paragraphs.
• Lum. Setting: Use this to activate the brightness limiter. When set to AUTO, the brightness of the screen is adjusted automatically to optimize picture quality.
Top
Right
S BY S1 S BY S2
Bottom
Right
IMINAR
L
Y
Select LEVEL 1, LEVEL 2 or LEVEL 3 to set the maximum brightness (black level) to 75%, 50% or 25% respectively of the peak level. (These values are approximate.)
•Orbiter: Select Orbiter from the PDP Protect menu to set the picture shift.
OFF: Orbiter mode does not function. This is the default setting when RGB is input.
AUTO1: The picture moves around the screen intermittently, making the picture
smaller. This is the default setting when a Video or DVD/HD/DTV signal is input. Set to OFF when these signals are not used.
AUTO2: The picture moves around the screen intermittently, making the picture
bigger.
Vidikron PlasmaView Owner’s Operating Manual 39
Note
PRE
When a Video or a DVD/HD/DTV signal is input, the AUTO1 and AUTO2 settings affect only the moving picture and do not change the image size.
Page 50
Operation
•Inverse: Select Inverse from the PDP Protect menu to set the inverse mode or to display a white screen.
OFF: Inverse/white mode does not function.
ON: The picture is displayed alternately between positive image and negative image.
WHITE: The entire screen turns white.
• Image Sweep: When Image Sweep is set to ON, a white vertical bar moves periodically from left to right across the screen, at a constant speed.
•Soften: Select Soften from the PDP Protect menu to reduce edges (color transitions) and soften the image.
OFF: Turns the SOFT FOCUS function off.
1, 2, 3, 4: Activates the SOFT FOCUS setting. Higher numbers create a “softer” image.
Note
•OSD Orbiter: Select OSD Orbiter from the PDP Protect menu to enable OSD menu shift.
ON: The position of the menu is shifted by eight dots each time the OSD is displayed.
OFF: The OSD is always displayed at the same position.
•OSD Contrast: Select OSD Contrast from the PDP Protect menu to reduce the contrast of the OSD menus.
LEVEL 1: Reduced OSD contrast.
LEVEL 2: Normal OSD contrast.
CC: Select CC from the Function menu to control the display of closed captions when watching programs that contain them.
Select one of four captioning modes: CAPTION1, CAPTION2, CAPTION3 or CAPTION4. CAPTION1 usually contains the native-language captions; if a program is captioned in more than one language, those captions are carried on CAPTION2, CAPTION3 or CAPTION4.
The PlasmaView also supports “text mode” captioning; to use this feature, select TEXT1,
PRE
TEXT2, TEXT3 or TEXT4. The text modes, instead of displaying a few lines of captions somewhere on the picture, take over all or half of the screen to display scrolling text information. (The text modes are seldom used today, so most of the time there is no information there to see.) The text field is sometimes used for embedding Internet data (called Interactive TV Links, or ITV Links) in the captions.
IMINAR
L
The Sharpness control (in the Picture Adjust menu) is disabled when you turn on the Soften feature.
Y
To hide the closed captions, set this option to OFF.
CC Contrast: Select CC Contrast from the Function menu to reduce the contrast of the closed captions.
LEVEL 1: Reduced CC contrast.
LEVEL 2: Normal CC contrast.
40 Vidikron PlasmaView Owner’s Operating Manual
Page 51
Pwr. On Select: Select Pwr. On Select from the Function menu to specify which input signal
SEL. OK
is displayed when you turn on the PlasmaView. You can also specify an initial audio volume level.
You can select a specific input or volume level (0 to 42). Or, select LAST to have the PlasmaView set the input and volume to what they were the last time it was turned off.
input signal. (If RGB/PC is the current input, “MODE” is replaced by “MEMORY.”)
Operation
PWR. ON SELECT
INPUT SELECT : RGB
VOLUME : 22
SEL. ADJ. RETURN
Signal Info Select Signal Info from the Main menu to check the frequencies and polarities of the current
EXIT
Press EXIT to return to the Main menu.
Y
IMINAR
L

SIGNAL INFO

H. FREQ : 48.4KHz
V. FREQ : 60.0Hz
H. POLARITY : NEG.
V. POLARITY : POS.
MODE : 480i
RESOLUTION : --
SEL. OK
RETURN
EXIT
Vidikron PlasmaView Owner’s Operating Manual 41
PRE
Page 52
Operation
Notes:
Y
IMINAR
L
PRE
42 Vidikron PlasmaView Owner’s Operating Manual
Page 53

5Maintenance and Troubleshooting

Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the PlasmaView. If the suggested solutions fail to resolve the problem or if you encounter an issue not described here, please contact your Vidikron dealer or Vidikron Technical Support.

Table 5-1. Troubleshooting Chart

Symptom Possible Cause(s) Solution
The display does not turn on after initial installation.
The display is on, but there is no picture or sound.
• The PlasmaView is not plugged in or the AC outlet is not active.
• The remote control batteries have run out.
• Incorrect source selection.
• Source component is not turned on.
• Source component is connected incorrectly or not at all.
IMINAR
• Ensure that the PlasmaView is plugged in and that the AC outlet is active.
• Replace the batteries.
• Select the correct source.
• Turn on the source component.
• Check video and/or audio connections to source component.
L
Picture is okay, but there is no sound.
Image is too bright and/or lacks definition in the bright areas of the image.
• Audio output is muted.
• Volume setting is too low.
• Contrast is set too high. • Lower the contrast setting.
•Press the MUTE button on the remote control.
• Turn up the volume.
PRE
Image appears “washed out” and/or dark areas appear too bright.
• Brightness is set too high. • Lower the brightness setting.

5.1 Troubleshooting Tips

Y
Colors in the image are swapped; for example, reds appear blue or vice versa.
RGB-HD images appear “noisy.”
Vidikron PlasmaView Owner’s Operating Manual 43
• The Red/Pr, Green/Y or
Blue/Pb outputs from the source are connected to the wrong inputs on the PlasmaView.
• Clock and Phase (Fine
Picture and Picture Adjust) settings need adjustment.
• Ensure that the source
• Manually adjust Fine
outputs are connected to the correct PlasmaView input.
Picture and Picture Adjust settings, or perform an Auto-Adjust (refer to
Adjust (available only on PC/RGB Input) on page 34).
Auto
Page 54
Maintenance and Troubleshooting
Table 5-1. Troubleshooting Chart (continued)
Symptom Possible Cause(s) Solution
“Out of range” appears on-screen.
The image is too large or too small.
IMINAR
•The resolution and frequency of the video card in the computer are not compatible with the PlasmaView.
• Image size needs adjusting. • Adjust the image size (refer
• Select a compatible resolution and vertical frequency (refer to
Computer/Video Signal Compatibility on page 57).
to Image Options on page 32).
Y
L
PRE
44 Vidikron PlasmaView Owner’s Operating Manual
Page 55

6Serial Communications

To interface the PlasmaView with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in
Configure the RS-232 controller or PC serial port as follows: odd parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate 9600, to match that of the PlasmaView RS-232 port.
Serial command messages to – and response messages from – the PlasmaView are in hexadecimal format. A command/response message consists of the following:
1. The first command or response byte. In responses from the PlasmaView, the second character (lower-order four bits) of this byte is F to indicate a valid command (as in the example below); when the PlasmaView receives an invalid command, the second character is B.
2. Two bytes that identify the sender and receiver respectively of the message. 60 is the PlasmaView; 80 is the personal computer or control system.
3. The second command byte.
4. The amount of command data, in bytes (0 for commands that do not take arguments, such as Power On/Power Off; otherwise, 1 to 7 bytes).
5. The command data.
6. A checksum, calculated by adding all of the bytes in the message. The lower-order (least significant) eight bits – that is, the last two digits – of the result are sent as the checksum.
IMINAR
L
Figure 3-4.
Y

6.1 RS-232 Connection and Port Configuration

6.2 Serial Command/Response Messages

PlasmaView:
Command
(Byte
DF 80 60 47 01 05 0C
Response
(Byte
3F 60 80 47 00 - 66
Vidikron PlasmaView Owner’s Operating Manual 45
1)
1)
PRE
Unit ID
(Sender)
Unit ID
(Sender)
(sum = 166 hex)
Unit ID
(Receiver)
(sum = 20C hex)
Unit ID
(Receiver)
Command
2)
(Byte
Response
2)
(Byte
Command
Data Length (Bytes)
Response
Data Length (Bytes)
Data Checksum
Data Checksum
-

ExampleThis is the command for selecting the DVD/HD1 input and the response from the

Page 56
Serial Communications

Command List Table 6-1 lists the RS-232 command set. Refer to Section 4, Operation, for detailed function

Table 6-1. Serial Commands
Function Command
Power ON 9FH 80H 60H 4EH 00H CDH
OFF 9FH 80H 60H 4FH 00H CEH
Input Select Video1 (RCA) DFH 80H 60H 47H 01H 01H 08H
Video2 (S-Video) DFH 80H 60H 47H 01H 02H 09H
DVD/HD1 (RCA) DFH 80H 60H 47H 01H 05H 0CH
DVD/HD2 (RCA) DFH 80H 60H 47H 01H 06H 0DH
DVD/HD3 (HDMI) DFH 80H 60H 47H 01H 0EH 15H
PC/RGB (DB-15HD) DFH 80H 60H 47H 01H 07H 0EH
DVD/HD4 (HDMI) DFH 80H 60H 47H 01H 1AH 21H
Audio Volume
0 (min) ... 42 (max)
descriptions. If you need further programming assistance, contact your Vidikron dealer or Vidikron Technical Support.
Command
Data
Length
(Bytes)
Data Checksum
Y
DFH 80H 60H 7FH 03H 05H 01H 00H ...
2AH
47H (=0) ...
71H (=42)
Audio Mute ON 9FH 80H 60H 3EH 00H BDH
OFF 9FH 80H 60H 3FH 00H BEH
Contrast 0 (min) ...
72 (max)
Brightness 0 (min) ...
64 (max)
Sharpness 0 (min) ...
32 (max)
Color 0 (min) ...
64 (max)
Tint 0 (min) ...
64 (max)
Video NR OFF DFH 80H 60H C0H 01H 01H 81H
VIDEO NR1 DFH 80H 60H C0H 01H 02H 82H
VIDEO NR2 DFH 80H 60H C0H 01H 03H 83H
VIDEO NR3 DFH 80H 60H C0H 01H 04H 84H
Color Temp. 5400K
8500K 9300K 6500K
PRE
DFH 80H 60H 7FH 03H 01H 07H CCH ...
DFH 80H 60H 7FH 03H 01H 08H E0H ...
DFH 80H 60H 7FH 03H 01H 06H F0H ...
DFH 80H 60H 7FH 03H 01H 04H E0H ...
DFH 80H 60H 7FH 03H 01H 05H E0H ...
DFH 80H 60H 00H 01H 00H
IMINAR
L
01H 02H 03H
14H
20H
10H
20H
20H
15H (=0) ...
5DH (=72)
2AH (=0) ...
6AH (=64)
38H (=0) ...
58H (=32)
26H (=0) ...
66H (=64)
27H (=0) ...
67H (=64)
C0H C1H C2H C3H
Gain/Offset (Red)
0 (min) ... 70 (max)
DFH 80H 60H 7FH 04H 01H 01H D8H ...
1EH
(Gain)
46 Vidikron PlasmaView Owner’s Operating Manual
D8H ...
1EH
(Offset)
F4H (=0/0) ...
80H (=70/70)
Page 57
Table 6-1. Serial Commands (continued)
Function Command
Gain/Offset (Green)
0 (min) ... 70 (max)
DFH 80H 60H 7FH 04H 01H 02H D8H ...
Command
Data
Length
(Bytes)
Serial Communications
Data Checksum
1EH
(Gain)
D8H ...
1EH
(Offset)
F5H (=0/0) ...
81H (=70/70)
Gain/Offset (Blue)
Cinema Mode
Image Preset
Gamma 2.1
Dither MODE1
Black Level NORMAL
ICC (Red) 0 (Y) ... 64 (M) DFH 80H 60H 0DH 07H 00H ... 40H for each color component, followed by 00H.
ICC (Green) 0 (Y) ... 64 (M)
ICC (Blue) 0 (Y) ... 64 (M)
ICC (Yellow) 0 (Y) ... 64 (M)
ICC (Magenta)
0 (min) ... 70 (max)
ON OFF
STANDARD DFH 80H 60H 0AH 01H 01H CBH
PRESET1 DFH 80H 60H 0AH 01H 02H CCH
PRESET2 DFH 80H 60H 0AH 01H 03H CDH
FACTORY DFH 80H 60H 0AH 01H 04H CEH
PRESET3 DFH 80H 60H 0AH 01H 05H CFH
2.2
2.3
2.4
MODE2
STEP1 STEP2
DFH 80H 60H 7FH 04H 01H 03H D8H ...
1EH
(Gain)
DFH 80H 60H C1H 01H 01H
02H
DFH 80H 60H 13H 02H 01H 00H
DFH 80H 60H 0CH 01H 01H
DFH 80H 60H 35H 01H 01H
IMINAR
L
02H
02H 03H
Calculate the checksum as described in Command/Response Messages on page 45.
Y
01H 02H 03H
D8H ...
1EH
(Offset)
F6H (=0/0) ...
82H (=70/70)
82H 83H
D5H D6H D7H D8H
CDH CEH
F6H F7H F8H
Serial
PRE
Example:
20H 20H 20H 20H 20H 20H 00H 93H
0 (Y) ... 64 (M)
(R) (G) (B) (Y) (M) (C)
sets ICC to 32 for all six color components.
ICC (Cyan) 0 (Y) ... 64 (M)
ICC Reset All -- 00H 00H 00H 00H 00H 00H 01H D4H
Bass 0 (min) ...
+26 (max)
Treble 0 (min) ...
+26 (max)
Balance -22 (L) ...
+22 (R)
Vidikron PlasmaView Owner’s Operating Manual 47
DFH 80H 60H 7FH 03H 05H 03H F3H ...
0DH
DFH 80H 60H 7FH 03H 05H 04H F3H ...
0DH
DFH 80H 60H 7FH 03H 05H 02H EAH ...
16H
3CH (=0) ...
56H (=+26)
3DH (=0) ... 57H (=+26)
32H (=-22) ...
5EH (=+22)
Page 58
Serial Communications
Table 6-1. Serial Commands (continued)
Function Command
Audio Setup (video input assign­ments)
Audio Input: AUDIO 1 AUDIO 2 AUDIO 3 DVD/HD3 (HDMI) DVD/HD4 (HDMI)
Video Input: VIDEO1 VIDEO2 DVD/HD1 DVD/HD2 PC/RGB DVD/HD3 DVD/HD4 DVD/HD INPUT (HDMI) DVD/HD INPUT (AUDIO INPUT 1-3)
DFH 80H 60H 70H 02H 01H
Command
Data
Length
(Bytes)
02H 03H 04H 05H
01H
Y
02H 05H 06H 07H 0EH 1AH 20H
21H
Data Checksum
33H (=01/01)
... 57H
(=05/21)
Aspect Ratio INTELLIWIDE DFH 80H 60H 51H 01H 02H 13H
LETTERBOX DFH 80H 60H 51H 01H 03H 14H
IMINAR
4:3 DFH 80H 60H 51H 01H 04H 15H
16:9 DFH 80H 60H 51H 01H 05H 16H
CINEMA FILL DFH 80H 60H 51H 01H 0AH 1BH
V. Shift -64 ...
+64
H. Shift -128 ...
+127
V. Size 0 ...
+64
H. Size 0 ...
+64
Auto Adjust ON
OFF
Fine Picture (Phase)
Picture Adj. (Clock)
0 ... +64
0 ... +128
DFH 80H 60H 7FH 03H 03H 01H C0H ...
DFH 80H 60H 7FH 03H 03H 02H 80H ...
PRE
DFH 80H 60H 7FH 03H 03H 07H 00H ...
DFH 80H 60H 7FH 03H 03H 08H 00H ...
DFH 80H 60H 7FH 03H 03H 09H 00H
DFH 80H 60H 7FH 03H 03H 03H 00H ...
DFH 80H 60H 7FH 03H 03H 04H C0H ...
L
40H
7FH
40H
40H
01H
40H
40H
05H (=-64) ...
85H (=+64)
05H (=-128) ...
85H (=+127)
4BH (=0) ...
8BH (=+64)
4CH (=0) ...
8CH (=+64)
4DH
4EH
47H (=0) ...
87H (=+64)
08H (=0) ...
88H (=+128)
HD Type 1035I
540P 1080I
HDMI Black Level
LOW HIGH
DFH 80H 60H 8AH 01H 01H
02H 03H
DFH 80H 60H 8FH 01H 01H
02H
48 Vidikron PlasmaView Owner’s Operating Manual
4BH 4CH 4DH
50H 51H
Page 59
Table 6-1. Serial Commands (continued)
Function Command
Video Standard
Background BLACK
3.58 NTSC
4.43 NTSC PAL SECAM AUTO PAL60 PAL-M PAL-N
GRAY
DFH 80H 60H 5CH 01H 01H
DFH 80H 60H 36H 01H 01H
Command
Data
Length
(Bytes)
02H 03H 04H 0AH 0BH 0DH
0EH
02H
Serial Communications
Data Checksum
Y
1DH
1EH
1FH 20H 26H 27H 29H 2AH
F7H
F8H
Sidebar Lev. 0 (min) ...
15 (max)
S1/S2 AUTO
OFF
OSD Adjust 1 (TOP L.)
2 (TOP C.) 3 (TOP R.) 4 (BTM. L.) 5 (BTM. C.) 6 (BTM. R.)
ID Remote ALL
1 2 3 4
Factory 1FH 80H 60H 54H 00H 53H
Auto Off ON
OFF
Input Skip ON
OFF
Sub Picture ­Sub P. Detect
OFF AUTO
PRE
DFH 80H 60H C6H 01H 00H ...
0FH
DFH 80H 60H 89H 01H 01H
02H
DFH 80H 60H 1AH 02H 02H 01H
02H 03H 04H 05H
IMINAR
DFH 80H 60H 2BH 01H 00H
DFH 80H 60H 1AH 02H 03H 01H
DFH 80H 60H 61H 01H 01H
DFH 80H 60H 7AH 01H 01H
L
01H 02H 03H 04H
02H
02H
06H
02H
86H ...
95H
4AH 4BH
DEH DFH
E0H
E1H
E2H
E3H
EBH ECH EDH
EEH
EFH
DFH
E0H
22H 23H
3BH 3CH
Sub Picture ­Sub P. Rate
Vidikron PlasmaView Owner’s Operating Manual 49
20% 30% 40% 50% 60% 70% 80% 90% 100%
DFH 80H 60H DAH 02H 01H 00H
01H 02H 03H 04H 05H 06H 07H 08H
9CH 9DH
9EH
9FH A0H A1H A2H A3H A4H
Page 60
Serial Communications
Table 6-1. Serial Commands (continued)
Function Command
Zoom Nav OFF
S BY S BTM LEFT BTM RIGHT TOP LEFT TOP RIGHT
DFH 80H 60H 7BH 01H 01H
Command
Data
Length
(Bytes)
02H 03H 04H 05H 06H
Data Checksum
3CH 3DH
3EH
3FH 40H 41H
Image Freeze (Mode)
Image Freeze On/Off
OFF S BY S1 BTM LEFT BTM RIGHT TOP RIGHT TOP LEFT S BY S2
FREEZE FREEZE OFF
DFH 80H 60H 7CH 01H 01H
DFH 80H 60H 7DH 01H 01H
IMINAR
L
PRE
02H 03H 04H 05H 06H 07H
02H
Y
3DH
3EH
3FH 40H 41H 42H 43H
3EH
3FH
50 Vidikron PlasmaView Owner’s Operating Manual
Page 61
Table 6-1. Serial Commands (continued)
Function Command
Pixel Protect Manual - Lum.
Setting: AUTO LEVEL 1 LEVEL 2 LEVEL 3
Manual - Inverse: OFF INVERSE WHITE
Manual - Orbiter: AUTO 1 OFF AUTO 2
DFH 80H 60H 6BH 03H 01H
DFH 80H 60H 6BH 03H 01H
DFH 80H 60H 6BH 03H 01H
Command
Data
Length
(Bytes)
02H 03H 04H
Y
02H 03H
Serial Communications
Data Checksum
30H
(=01/01/01) ...
37H
(=04/03/03)
02H 03H
Manual - Image Sweep: ON OFF
Manual - Soften: OFF 1 2 3 4
Manual - OSD Orbiter: ON OFF
Manual - OSD Contrast: LEVEL 2 LEVEL 1
CC Mode OFF
CAPTION1 CAPTION2 CAPTION3 CAPTION4 TEXT1 TEXT2 TEXT3 TEXT4
DFH 80H 60H C8H 04H 01H
DFH 80H 60H 65H 01H 01H
IMINAR
L
DFH 80H 60H 5FH 01H 01H
PRE
DFH 80H 60H 37H 01H 01H
DFH 80H 60H 3CH 01H 00H
02H
02H 03H 04H 05H
02H
02H
01H 02H 03H 04H 05H 06H 07H 08H
00H FFH 01H 8CH
8DH
26H 27H 28H 29H 2AH
20H 21H
F8H
F9H
FCH FDH
FEH
FFH 00H 01H 02H 03H 04H
CC Contrast LEVEL2
LEVEL1
Vidikron PlasmaView Owner’s Operating Manual 51
DFH 80H 60H 3DH 01H 01H
02H
FEH
FFH
Page 62
Serial Communications
Table 6-1. Serial Commands (continued)
Function Command
Pwr. On Select (Input)
Pwr. On Select (Volume)
LAST VIDEO1 VIDEO2 DVD/HD1 DVD/HD2 PC/RGB DVD/HD3 DVD/HD4
LAST
0 (min) ... 42 (max)
DFH 80H 60H 63H 04H 00H
DFH 80H 60H 0FH 01H A0H
Command
Data
Length
(Bytes)
01H 02H 05H 06H 07H
0EH
1AH
00H ...
2AH
Data Checksum
00H 01H 00H 27H
28H 29H 2CH 2DH
2EH 35H 41H
Y
6FH
CFH (=0) ...
F9H (=42)
Side-By-Side / Picture­in­Picture
Single Screen DFH 80H 60H 07H 01H 00H C7H
S BY S1 DFH 80H 60H 07H 01H 01H C8H
S BY S2R DFH 80H 60H 07H 01H 02H C9H
IMINAR
L
S BY S2L DFH 80H 60H 07H 01H 05H CCH
PRE
PIP Bottom Left (four sizes)
DFH 80H 60H 07H 01H 03H CAH
DFH 80H 60H 07H 01H 06H CDH
DFH 80H 60H 07H 01H 08H CFH
DFH 80H 60H 07H 01H 0AH D1H
PIP Bottom Right (four sizes)
DFH 80H 60H 07H 01H 04H CBH
DFH 80H 60H 07H 01H 07H CEH
DFH 80H 60H 07H 01H 09H D0H
DFH 80H 60H 07H 01H 0BH D2H
52 Vidikron PlasmaView Owner’s Operating Manual
Page 63
Table 6-1. Serial Commands (continued)
Function Command
Side-By-Side / Picture­in­Picture (cont.)
PIP Top Right (four sizes)
DFH 80H 60H 07H 01H 41H 08H
DFH 80H 60H 07H 01H 42H 09H
DFH 80H 60H 07H 01H 43H 0AH
DFH 80H 60H 07H 01H 44H 0BH
Command
Data
Length
(Bytes)
Serial Communications
Data Checksum
PIP Top Left (four sizes)
S BY S3 DFH 80H 60H 07H 01H 49H 10H
S BY S4R DFH 80H 60H 07H 01H 4AH 11H
DFH 80H 60H 07H 01H 45H 0CH
DFH 80H 60H 07H 01H 46H 0DH
DFH 80H 60H 07H 01H 47H 0EH
DFH 80H 60H 07H 01H 48H 0FH
Y
IMINAR
L
S BY S4L DFH 80H 60H 07H 01H 4BH 12H
PRE
SWAP PIP DISABLE PIP ENABLE S BY S ACTIVE L S BY S ACTIVE R PIP ACTIVE MAIN PIP ACTIVE SUB
DFH 80H 60H 07H 01H 10H
A0H A1H 20H 21H 30H 31H
D7H 67H 68H
E7H
E8H
F7H
F8H
Vidikron PlasmaView Owner’s Operating Manual 53
Page 64
Serial Communications
Table 6-1. Serial Commands (continued)
Function Command
Pwr. On Select (Multi­Screen Mode)
Power On Mode: LAST MULTI
Power On Multi Mode Type: S BY S1 S BY S2R S BY S2L PIP Bottom Left PIP Bottom Right PIP Top Right PIP Top Left
Left or Main Input:
DFH 80H 60H 33H 04H 01H
DFH 80H 60H 33H 04H 01H
Command
Data
Length
(Bytes)
02H
02H 03H
Y
04H 05H 06H 07H
Data Checksum
Calculate the checksum as described in
Serial Command/ Response Messages
on page 45.
VIDEO1 VIDEO2 DVD/HD1 DVD/HD2 PC/RGB DVD/HD3 DVD/HD4
Right or Sub Input:
VIDEO1 VIDEO2 DVD/HD1 DVD/HD2 PC/RGB DVD/HD3 DVD/HD4
PRE
DFH 80H 60H 33H 04H 01H
02H 05H 06H 07H 0EH
IMINAR
1AH
L
DFH 80H 60H 33H 04H 01H
02H 05H 06H 07H 0EH 1AH
54 Vidikron PlasmaView Owner’s Operating Manual
Page 65

7Specifications

Table 7-1 lists the PlasmaView specifications.

Table 7-1. PlasmaView Specifications

Native Resolution: 1365 x 768 WXGA
Screen Size (diagonal): 50 in.
Active Screen Area: 43.5 x 24.5 in. (1106 x 622 mm)
Screen Aspect Ratio: 16:9
Available Aspect Ratios: 4:3, Letterbox, 16:9, IntelliWide™, Cinema Fill
DTV Compatibility: 480i/p, 525i/p, 540p, 625i/p, 720p, 1035i, 1080i/p
ISF Settings: Yes
Data/Graphics Compatibility: Up to 1600 x 1200
Inputs: (1) Composite, (1) S-Video, (2) HD Component,
(2) HDMI 1.1 with HDCP, (1) RGB (15-pin D-sub), (3) Audio (stereo RCA pairs), (1) RS-232, (1) Wired IR (3.5-mm mini jack)
Outputs: (1) Speaker Terminals (stereo pair), Wired IR (loop-through)
Audio System: Internal amplifier
Output Power = 9W RMS x 2
IMINAR
L

7.1 PlasmaView Specifications

Y
Discrete IR Control: Source, power and aspect ratios
Power Requirements: 100 to 240 VAC, 50/60Hz
Power Consumption (typical): 350W
Operating Environment: 40ºF to 95ºF (5ºC to 35ºC);
Dimensions: See Figure 7-1
Weight (with Stand): 97.9 lbs. (44.50 kg)
Regulatory Approvals: Complies with FCC
Limited Warranty: Three (3) years parts and labor from the date of delivery to
Specifications are subject to change without notice.
Vidikron PlasmaView Owner’s Operating Manual 55
PRE
20% to 80% humidity (non-condensing) Altitude -- up to 9,000 feet/2,740m (Model VP-5000a only)
the end user (except for plasma glass panel). Plasma Glass Panel: One (1) year parts and labor from the date of delivery to the end user.
Page 66
Specifications

7.2 PlasmaView Dimensions

Figure 7-1 shows the PlasmaView dimensions (all dimensions are in inches).
24.50
49.98
43.50
26.37
5.50
20.87
Y
2.13
6.51 3.50
3.97
IMINAR
13.98
L
4.83
2.13
PRE
0
13.81
34.68
48.41

Figure 7-1. PlasmaView Model VP-5000/VP-5000a Dimensions (with Table Stand)

0
24.51
29.29
56 Vidikron PlasmaView Owner’s Operating Manual
Page 67
Specifications
The PlasmaView can display video signals from a variety of computer sources via its RGB-HD and HDMI inputs.
Table 7-2 lists the signal types that are compatible with the PlasmaView, and indicates which of those are VESA standards.

Table 7-2. Computer/Video Signal Compatibility Chart

Signal Type
IBM 640x400 70.10 31.50 neg neg
IBM
MAC 66.70 35.00 Sync on Green
VESA 72.80 37.90 neg neg
VESA 75.00 37.50 neg neg
VESA 85.00 43.30 neg neg
IBM 100.40 51.10 neg neg
IBM 120.40 61.30 neg neg
IBM
VESA 85.10 37.90 neg pos
VESA
VESA 60.30 37.90 pos pos
Mode
(Dots x Lines)
640x480
720x400
Vertical
Frequency (Hz)
59.90 31.50 neg neg
70.10 31.50 neg neg
Horizontal
Frequency (kHz)
IMINAR
56.25 35.20 pos pos
L
Sync Polarity
Horiz. Vert.
Y

7.3 Computer/Video Signal Compatibility

VESA 72.20 48.10 pos pos
VESA 75.00 46.90 pos pos
VESA 85.10 53.70 pos pos
IBM 99.80 63.00 pos pos
IBM 120.00 75.70 pos pos
MAC 832x624 74.60 49.70 Sync on Green
IBM 848x480 60.00 31.00 pos pos
IBM 852x480 60.00 31.70 neg neg
Notes:
1. The PlasmaView may not be able to display images from notebook computers in simultaneous (CRT/LCD) mode. Should this occur, switch the notebook computer to “CRT only” mode. If you are unsure how to do this, refer to your notebook computer’s user manual.
2. All modes other than the native resolution (1365x768) are scaled up or down to that resolution.
800x600
PRE
Vidikron PlasmaView Owner’s Operating Manual 57
Page 68
Specifications
Table 7-2. Computer/Video Signal Compatibility Chart (continued)
Signal Type
VESA
SGI 60.00 49.70 -- --
VESA 70.10 56.50 neg neg
MAC 74.90 60.20 Sync on Green
VESA 75.00 60.00 pos pos
VESA 85.00 68.70 pos pos
IBM 100.00 80.50 neg neg
IBM 1280x768 56.20 45.10 pos pos
SGI 1280x1024 60.00 63.90 -- --
IBM 1280x1024 60.00 64.00 pos pos
HP 1280x1024 72.00 81.10 -- --
IBM 1280x1024 75.00 80.00 pos pos
SUN 1280x1024 76.10 81.10 Composite sync
IBM 1280x1024 85.00 91.10 pos pos
IBM 1280x1024 100.10 108.50 pos pos
IBM 1360x768 60.00 47.70 pos pos
Mode
(Dots x Lines)
1024x768
IMINAR
Vertical
Frequency (Hz)
60.00 48.40 neg neg
Horizontal
Frequency (kHz)
Y
Sync Polarity
Horiz. Vert.
L
IBM 1400x1050 60.00 65.30 neg pos
IBM 1400x1050 75.00 82.30 neg pos
IBM 1400x1050 85.00 93.90 neg pos
Notes:
PRE
1. The PlasmaView may not be able to display images from notebook computers in simultaneous (CRT/LCD) mode. Should this occur, switch the notebook computer to “CRT only” mode. If you are unsure how to do this, refer to your notebook computer’s user manual.
2. All modes other than the native resolution (1365x768) are scaled up or down to that resolution.
58 Vidikron PlasmaView Owner’s Operating Manual
Page 69
Page 70
RUMA-011235
rev. 05-11-07 v2.0
Vidikron 2900 Faber Street Union City, CA 94587 510-324-5900 Fax 510-324-5905 1-888-4-VIDIKRON www.vidikron.com
SERIAL NUMBER