Technical Characteristics
Codes: 99 User Codes (1 - 8 digits)
Relays / Outputs: 1 Relay - R1: (2A @ 24v AC/DC)
1 Transistor Output - T1: (Ic max = 800mA, Vceo max = 30v)
Relay / Output Time: 1 - 99 Seconds or latching (00)
IP Rating IP67
Power: 12/24v AC/DC
Current: Standby 20mA / Maximum 70mA
Dimensions
1
EX5

Installation Instructions
2
4.
1.
3.
5.
3 (M4 x 30mm CSK Philips)
6.
1 (M3 x 6mm)
2.
Magnet holder
2 (M4 x 30mm CSK Philips)
Flat surface
Colour
Connections
Tamper
Relay
Mandatory
12/24V
AC/DC
Exit
NO
C
NC
Transistor
G
NO
NC
Do not apply any voltage to the CODIX BUS.
Red
Black
White
Yellow
Grey
Green
Blue
Orange
Brown
Violet
Pink
Dipswitch
DG/WS/0002 IS-01
12/24V
(AC/DC)
(CA/CC)
Terminal Connections
Colour
Connections
GND
Black
Violet
Grey
DATA
+9V

3
EX5
12v / 24v DC Wiring Diagram
DG/WS/0002 IS-01
12/24V
(AC/DC)
(CA/CC)
Black
Red
White
Yellow
Grey
Green
Blue
Orange
Brown
Voilet
Pink
12v / 24v AC Wiring Diagram
IN4002
100nF
PTE
(Normally Open)
12/24 DC
PSU
+
-
12/24 AC
PSU
DG/WS/0002 IS-01
12/24V
(AC/DC)
(CA/CC)
Black
Red
White
Yellow
Grey
Green
Blue
Orange
Brown
Voilet
Pink
PTE
(Normally Open)

4
EX5
Using Transistor Output With a Art.506 Relay (12v dc)
DG/WS/0002 IS-01
12/24V
(AC/DC)
(CA/CC)
Black
Red
White
Yellow
Grey
Green
Blue
Orange
Brown
Voilet
Pink
12 DC
PSU
+
-

Adding a User Code
Enter Master Code
(Factory Default = 000)
Followed by B
Press 0
Enter <user number> (01-99)
(Up to 99 codes may be added)
Enter <new user code> (1-8 digits)
Press 3 + <user number>
Press A
Enter <output number> to be triggered
[1 = Relay] [2 = Transistor] [12 = both]
Press A
Press B to exit programming
Relay/Output Time
Enter <output number> (1 or 2)
Enter <output time> (01-99)
(Enter 00 if latch mode required)
Press A
Press B to exit programming
Delete a User Code
Press 9
Enter <user number> (01-99)
to delete
Press A
Press B to exit programming
Delete All Codes
Press 8
Press A
Press B to exit programming
Press 99
5
EX5
More
codes?
Yes
No
Enter Master Code
(Factory Default = 000)
Followed by B
Enter Master Code
(Factory Default = 000)
Followed by B
More
outputs?
Yes
No
More
codes?
Yes
No
Enter Master Code
(Factory Default = 000)
Followed by B
Yellow LED on
Yellow LED off
Yellow LED on
Yellow LED off
Yellow LED on
Yellow LED on
Yellow LED off
Yellow LED off

6
EX5
Resetting the Master Code
Disconnect power.
Switch on dip switch 1.
Reconnect power.
Beep Beep + Yellow LED blinks
Switch off dip switch 1
Yellow LED switches on + Long beep
Enter the default master code 000
Enter the new master code e.g 2578
Press A followed by Beep Beep
Press B and the yellow LED switches off
000
2578
A
B
Troubleshooting
Keypad does not respond to key presses
1. Check the correct voltage is present on the input terminals (12/24v ac/dc).
Keypad is not accepting default master code 000
1. Perform master code reset.
Keypad no longer accepts user code
1. Check master code has been changed from the default.
2. Check back EMF protection across lock release.
Keypad accepts user code but no longer releases lock
1. Check the correct relay output is assigned to user code.
2. Check all push to exit buttons are normally open.
3. Check for continuity across relay contacts when user code is entered.
4. Check lock wiring for continuity.
5. Check the correct voltage is present on the input terminals (12/24v ac/dc).
Relay triggers and does not return back to its previous state
1. Check relay is not set up to latch

8
EX5
Northern Office
Videx Security Ltd
Unit 4-7 Chillingham ind Est
Newcastle Upon Tyne
NE6 2XX
Tel: 0870 300 1240
Fax: 0191 224 5678
Southern Office
1 Osprey
Trinity Park
Trinity Way
London
E4 8TD
Fax: 0208 523 5825
Technical Support
Tel: 0191 224 3174
Fax: 0191 224 4938
http://www.videx-security.com
tech@videx-security.com