Videx GSM LITE LTGSM4K Series, GSM LITE LTGSM4KC Series, GSM LITE LTGSM4K-2S, GSM LITE LTGSM4K-2, GSM LITE LTGSM4KC-1, GSM LITE LTGSM4KC-1S, GSM LITE LTGSM4KC-2S, GSM LITE LTGSM4KC-2, GSM LITE LTGSM4K-1, GSM LITE LTGSM4K-1S Technical Manual
We recommend
This equipment is installed by a
Competent Electrician, Security or
Communications Engineer.
4000 Series GSM Lite Audio Intercom
Declaration of Conformity
EU RoHS DECLARATION OF CONFORMITY
2G version
Telit Communications certies that the GL865-QUAD V3 (Quad Band GSM850/EGSM900/DCS1800/PCS1900 GPRS Wireless Module)
is in conformity with Directive 2011/65/EU of the European Parliament and the Council of 8th June 2011 on the restriction of the
use of certain hazardous substances in electrical and electronic equipment. The conformity with the applicable requirements of the
Directive 2011/65/EU has been demonstrated against the following harmonized standard: EN 50581:2012 Technical Documentation
for the assessment of electrical and electronic products with respect to the restriction of hazardous substances.
3G version
Telit Communications certies that the UL865-EUR (Dual Band 2G EGSM900/DCS1800 and Dual Band 3G FDD I/FDD VIII Wireless
Module) is in compliance with the essential requirements and other relevant provisions of European Directive 1999/5/EC (R&TTE).
The conformity with the essential requirements of the Directive 1999/5/EC has been demonstrated against the following harmonized
standards:
Article of Directive 1999/5/ECHarmonized Standard Reference
Health & Safety (R&TTE art. 3.1a)
EMC (R&TTE art. 3.1b)
RF Spectrum use (R&TTE art. 3.2)
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + AC2011
EN 62311:2008
EN 301 489-1 V1.9.2
EN 301 489-7 V1.3.1
EN 301 489-24 V1.5.1
EN 301 511 V9.02
EN 301 908-1 V5.2.1
EN 301 908-2 V5.2.1
To comply with FCC RF exposure requirements, a separation distance of 20cm (7.87”) or more
must be maintained between the antenna of this product and all persons.
Separate FCC approval for this product is not required as it will be classed as a xed installation.
THIS PRODUCT IS NOT DESIGNED TO BE USED AS AN EMERGENCY CALL POINT.
MANUFACTURER
THE POWER TO SECURE
VIDEX ELECTRONICS S.P.A.
Via del Lavoro, 1 - 63846 Monte Gilberto (FM) Italy
Tel: (+39) 0734-631699 - Fax: (+39) 0734-632475
www.videx.it - info@videx.it
The product is CE marked demonstrating its conformity and is for distribution
within all member states of the EU with no restrictions. This product follows
the provisions of the European Directives 2014/30/EU (EMC); 2014/35/EU
(LVD); 2011/65/EU (RoHS): CE marking 93/68/EEC.
4000 Series GSM Lite Audio Intercom - Technical Manual
System Components and Available Versions ..................................................................................................................................6
Art. 4811 Technical Information .................................................................................................................................................... 10
Art. 4901 Technical Information .................................................................................................................................................... 12
General Directions for Installation ................................................................................................................................................ 22
Fitting the SIM & Connecting Power ............................................................................................................................................. 25
4000 Series Back Box Installation ................................................................................................................................................. 27
Programming the GSM Intercom .................................................................................................................................................. 29
The GSM Mobile App ...................................................................................................................................................................... 41
System Operation ........................................................................................................................................................................... 42
User Commands .............................................................................................................................................................................. 43
Additional User Information .......................................................................................................................................................... 44
User Management .......................................................................................................................................................................... 46
General Information ....................................................................................................................................................................... 49
4000 Series GSM Lite Audio Intercom - Technical Manual
- 3 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Introduction
MANUAL INTRODUCTION
The information in this manual is intended as an installation and commissioning guide for the 4000 series GSM LITE audio intercom
system. This manual should be read carefully before the installation commences. Any damage caused to the equipment due to faulty
installation where the information in this manual has not been followed is not the responsibility of Videx Security Ltd.
It is recommended that the GSM audio intercom is installed by a competent electrician, security or communications engineer.
For UK customers Videx run free training courses for engineers who are unfamiliar or who have not installed this system before.
Technical help is also available for UK customers on tel: 0191 224 3174 during oce hours (8:30am - 5:00pm MON to FRI) or via e-mail:
tech@videxuk.com and for all overseas customers on tel: +39 0734 631669 or via e-mail: technical@videx.it.
A copy of this Technical Manual can also be downloaded from the Videx websites: For UK customers www.videxuk.com and for
overseas customers www.videx.it.
SYSTEM INTRODUCTION
The system is designed to work on the same technology as mobile phones. It enables a call to be made from an entry point (door,
gate etc), to any telephone number (mobile or land line). Up to 4 call buttons are available in the door panel, each able to call two
telephone numbers a primary number and a divert number (if the rst is busy or not answered, the call can be diverted to a second
number). The standard GSM LITE intercom works on a 2G network. A 3G variant is also available (sux /3G to the part number e.g.
Art.4811-1/3G, Art.4811-2/3G etc.). Features of the system include:
• A dry contact relay output and push to exit input;
• A single open collector auxiliary output (AO1) and two auxiliary inputs;
• Dial to Open facility (this feature enables up to 100 stored numbers to dial the GSM LITE intercom, the intercom panel will
not answer these calls, but will activate the door/gate relay without being charged for the call);
• Program both primary and divert number in a single text message;
• Program up to 5 dial to open (DTO) numbers in a single text;
• Delete a dial to open (DTO) number without knowing it’s stored location;
• Up to 5 possible auxiliary output modes (AOM);
• Programming carried out via SMS text messages or limited programming features using the GSM mobile app, the Videx SMS Wizard.
SIM CARD SELECTION
A SIM card is required for this product but not supplied by Videx. The GSM Lite intercom can only accept a standard size SIM card
(refer to the following SIM card size chart below), both a micro-SIM and nano-SIM are not suitable. It is recommended to choose the
SIM card which has the best coverage for the area in which the intercom panel will be installed. Both contract and ‘Pay as you go’
SIM cards can be used, however if using a ‘Pay as you go’ we would recommend setting up an automatic top up to avoid running
short on credit and losing the use of the intercom panel. Alternatively if you already have a contract mobile phone it should be
possible to get a second SIM card and telephone number on the existing account. For more information contact the SIM card
provider or visit their website, as this service is not provided by Videx.
Standard SIMMicro-SIMNano-SIM
25mm
15mm
15mm
12mm
12.3mm
8.8mm
;
NETWORK PROVIDER SELECTION
It is imperative that for the reliable operation of the system that the best network provider for the area is selected. Problems such as
network disconnection can occur if the provider has signal or interference problems for that area. We would recommend using a GSM
signal strength meter to survey the intended antenna location. Contact Videx for more information on where to purchase a tester.
For UK customers, as an initial check we also recommend visiting the ofcom website www.ofcom.org.uk and follow the onsite links to
their online mobile coverage tool (ofcom broadband and mobile checker app). This tool will advise on the best coverage for the main
network providers and other general queries that you may have about the service provider. For all overseas customers we suggest
consulting the website of the network provider that will be used to check the coverage in your area.
4000 Series GSM Lite Audio Intercom - Technical Manual
:
- 4 -
:
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Introduction
The antenna should always be mounted vertically at the highest point possible. Metal structures and sources of interference such as
power cables, control panels etc. can aect signals and so the antenna should be mounted away from these.
When registering a new SIM you may be asked for the IMEI number. This is the unique serial number of the GSM intercom. This
number is located internally on the main hardware chip inside the GSM LITE module. To obtain the IMEI number from the GSM
module refer to the programming notes obtain the GSM’s IMEI number on page 39.
PRECAUTIONARY ADVICE
• When mounting the GSM antenna, choose a location which is away from human interaction and away from the intercom panel.
Route the GSM antenna cable from the intercom panel so that it is separate from the power supply cables and microphone wire.
• Always ensure the power is switched OFF to the intercom panel before inserting or removing the SIM card.
• New SIM cards will need registering with the network service provider before they can be used. Full details of how this is done
can normally be found in the SIM card pack. It will normally require that the SIM card is inserted into a mobile phone, a number
dialled and instructions followed. While the SIM is in the mobile phone it would be a good time to disable any PIN codes, call
diverts, ring back and disable features such as voicemail and text alerts. Details of how to do this can be found on the SIM
card provider’s website or by calling their customer services. Recommended SIM card providers are: Vodafone, T-Mobile, O2
or Orange/EE. The 3 network can only be used on our 3G devices (Art.4811-1/3G, Art.4811-2/3G etc.), also refer to page 6.
• To be able to receive text messages from the intercom panel, the SIM card will require an SMS service centre number. This is
normally pre-installed on new SIM cards but if you are having trouble receiving SMS messages you will need to conrm this by
inserting the SIM card into a mobile phone and using the phones menu options to check it. If a number is not programmed then
it should be programmed while in the phone (the number can be obtained from the network service provider).
• Voicemail and text alerts must be switched OFF on the SIM card when using the dial in to release the door/gate feature. For
Vodafone and O2 this can be done while the SIM card is in the intercom panel. For Orange/EE, T-Mobile and other providers the
SIM card must be removed from the intercom panel, inserted into a mobile phone and the mobile phone menu instructions
followed. This procedure may vary from provider to provider of dierent countires, we suggest contacting your provider for
information.
• When storing the intercom panel’s telephone number in your own mobile phone avoid using an obvious name such as ‘Front
Door’, or ‘My Gate’ as this would make it easy to decipher if your phone was lost or stolen.
• The PIN request feature must be disabled on the SIM card before using it in the Intercom panel. It is likely on a new SIM card that
it will not be enabled but if it is, it will prevent the system from working at all.
• This product may not be suitable for installation in hospitals, health care facilities or in the presence of ammable gases or
liquids. Seek advice and authorisation before installing this product in these locations. This product is not designed to be used
as an emergency call point.
Network provider and services conguration codes mentioned in this manual are specic for the UK. For overseas customers please contact
the network provider of your country for the corresponding codes, however Videx oers no guarantee that any additional codes will work.
IMPORTANT NOTE ABOUT THE SIM
When using a pay monthly SIM card you can ask the service provider to put a spend limit (credit limit) on the account (Vodafone
call this service ‘spend checker’). This is to safeguard against possible problems which could result in a large phone bill at the end
of the month. Most network providers oer this service. You will need to either ring or e-mail them to set this up. Automatic top
ups should also have a monthly limit. We would suggest a limit of £50.00 which should be more than enough. This service is not
provided by Videx.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 5 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
System Components and Available Versions
DESCRIPTION
A system comprises of an intercom panel, power supply, SIM card (SIM card not provided by Videx) and antenna. The intercom panel
is part of the Videx 4000 series modular design allowing it to be customised to the installation requirements for example including
coded access or including the correct number of call buttons (up to 4 call buttons in total, all of which are internally wired in the
GSM LITE module).
ART. 4811 GSM LITE INTERCOM AVAILABLE VERSIONS
The intercom panel can include any of the following modules from the 4000 series range and uses the standard 4000 series surface
and ush mounting frames. The GSM LITE module is however essential and includes all the GSM communication electronics, SIM
card (supplied separately) and connections. The intercom module is available in a 1 button, 2 button and 4 button conguration
(with all onboard buttons internally wired), as shown in Fig.1 along with their part numbers.
24
13
Art. 4811-1
Art. 4811-1/3G
Fig. 1
4000 SERIES BACK BOXES AND MOUNTING FRAMES
Both surface and ush back boxes and mounting frames are available. The size of the frame will depend on the number of modules
that make up the LTGSM4K/LTGSM4KC kit. The last digit of the frame code indicates the number of modules it will take. Frames are
available in gun metal grey nish. The 4000 series mounting frames available GSM LITE kits are shown in Fig.2 (ush) and Fig.3
(surface) with the following tables showing the back box dimensions including the part numbers and dimensions for optional ush
and surface 4000 series rainshields.
Art. 4811-2
Art. 4811-2/3G
Art. 4811-1D
Art. 4811-1D/3G
Art. 4811-2D
Art. 4811-2D/3G
13
Flush Back Boxes and Mounting Frames
Art. 4851Art. 4852
Fig. 2
Flush Back Box Dimensions (inc. optional ush rainshields)
Part No.Housed ModulesFront Frame (W x H x D) mmBack Box (W x H x D) mm
Art.48511135 x 160 x 15.7120 x 143 x 46
Art.48522135 x 280.2 x 15.7120 x 263.2 x 46
Part No.Module SizeRainshield Dimensions (W x H x D) mm
Art.48711140 x 163 x 35
Art.48722140 x 283 x 35
4000 Series GSM Lite Audio Intercom - Technical Manual
- 6 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
System Components and Available Versions
Surface Back Boxes and Mounting Frames
Art. 4851Art. 4852
Fig. 3
Surface Back Box Dimensions (inc. optional surface rainshields)
Part No.Housed ModulesNo. of ColumnsBack Box (W x H x D) mm
Art.488111135 x 160 x 43
Art.488221135 x 280.2 x 43
Part No.Module SizeRainshield Dimensions (W x H x D) mm
Art.48911140 x 163 x 62
Art.48922140 x 283 x 62
12VDC 2A POWER SUPPLY HDR1512
The Art. 4811 GSM LITE intercom is designed to work with power supplies in
the range of 12Vdc and should be capable of supplying a constant current of
no less than 1A. Both the LTGSM4K and LTGSM4KC kits are supplied with a slim
line HDR-15-12, 12Vdc 1.25A power supply (refer to Fig.4).
Fig. 4
4000 Series GSM Lite Audio Intercom - Technical Manual
- 7 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
System Components and Available Versions
ART. 432 GSM ANTENNA
The Art.432 GSM antenna connects to the SMA female bulkhead connection on the
rear of the Art.4811 GSM LITE module. A GSM antenna with an SMA male connector
should be used (refer to Fig.5).
Antenna Parts
1. GSM antenna with magnetic base.
2. Self-threading screw (Ø3.5mm x 9.5mm).
3. Aluminium L bracket for mounting.
4. SMA male connector (cable length 2.5m).
5. Expansion type wall plugs (Ø6mm).
6. Self-threading screw (Ø4mm x 30mm).
7. Right angled SMA adapter.
IMPORTANT NOTE: An antenna must always be tted for the GSM module to
work. Always route the GSM antenna cable away from the microphone wires
and the power supply wires to avoid interference on the speech channels.
In instances where there is a tight tting space for the SMA male connector on
the antenna cable the right angled SMA adapter
7
can be used to help reroute
the cable down the back side of the GSM module.
SMA female bulkhead
connection on rear of
Art.4810 GSM PRO module
ART. 4901 CODELOCK
The Art.4901 codelock module with blue backlit buttons and is included as
part of the LTGSM4KC kits, see Fig.6, can be powered from 12-24V AC or DC
and includes three dry contact relay outputs and two switched 0V push to exit
inputs which can be used to trigger relay 1 & 2.
One code per relay can be programmed into the device. Codes can be between
4 - 8 digits long.
The relay time can be 01 - 99 seconds or set for latching (00). When in latching
mode, enter the code followed by ENTER
followed by CLEAR
to unlatch the relay.
to latch the relay and the code
Fig. 5
Fig. 6
4000 Series GSM Lite Audio Intercom - Technical Manual
1 Outdoor station composed of:
1 Art.4811-2: 2 button GSM (lite) unit
1 Art.4851: Flush mounting box
1 GSM antenna
Art.432
1 GSM antenna
Art.432
1 GSM antenna
Art.432
1 Power supply
HDR-15-12
12Vdc 1.25A
1 Power supply
HDR-15-12
12Vdc 1.25A
1 Power supply
HDR-15-12
12Vdc 1.25A
LTGSM4K-2S - surface mounting
1 Outdoor station composed of:
1 Art.4811-2: 2 button GSM (lite) unit
TWO WAY VERSIONS
LTGSM4KC-1 - ush mounting
LTGSM4KC-1S - surface mounting
ONE WAY VERSIONS
LTGSM4KC-2 - ush mounting
1 Art.4881: Surface mounting box
1 Outdoor station composed of:
1 Art.4811-1: 1 button GSM (lite) unit
1 Art.4901: 4000 series codelock
1 Art.4852: Flush mounting box
1 Outdoor station composed of:
1 Art. 4811-1: 1 button GSM (lite) unit
1 Art.4901: 4000 series codelock
1 Art.4882: Surface mounting box
1 Outdoor station composed of:
1 Art.4811-2: 2 button GSM (lite) unit
1 Art.4901: 4000 series codelock
1 Art.4852: Flush mounting box
1 GSM antenna
Art.432
1 GSM antenna
Art.432
1 GSM antenna
Art.432
1 GSM antenna
Art.432
1 Power supply
HDR-15-12
12Vdc 1.25A
1 Power supply
HDR-15-12
12Vdc 1.25A
1 Power supply
HDR-15-12
12Vdc 1.25A
1 Power supply
HDR-15-12
12Vdc 1.25A
LTGSM4KC-2S - surface mounting
1 Outdoor station composed of:
1 Art.4811-2: 2 button GSM (lite) unit
TWO WAY VERSIONS
IMPORTANT NOTE: The GSM audio kits listed above work on a 2G network. For the 3G variant remember to sux the kit part
no. with /3G, e.g. LTGSM4K-1/3G, LTGSM4KC-2S/3G etc.
All GSM audio kits are supplied with a HDR-15-12 12Vdc, 1.25A slim line power supply and Art.432 antenna.
4000 Series GSM Lite Audio Intercom - Technical Manual
1 Art.4901: 4000 series codelock
1 Art.4882: Surface mounting box
1 GSM antenna
Art.432
- 9 -
1 Power supply
HDR-15-12
12Vdc 1.25A
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Art. 4811 Technical Information
ART. 4811 GSM LITE MODULE
103mm
120mm
Internal jumper JP2
Nameplate LED illumination adjustment
There are 2 dip-switches located on the back of the GSM module next to the
antenna connection, see Fig.7,
. They can be used to adjust the volume from
the door intercom speaker (see table below). Additionally, the volume can also
be adjusted during a call electronically via the telephone keypad (refer to user
command table on page 43).
Internal nameplate LED jumper (JP2)
Nameplate window
Call button
Intercom speaker
Current rmware version (GSMLT X.X.X)
Dip-Switch
ON
12
ON
12
ON
12
ON
12
Dip-Switch Status
Dip No.1Dip No.2
ONON6
ONOFF12
OFFON18
OFFOFF23.5
Gain (dB)
Power input and auxiliary terminal AO1
GSM function terminals (g, 1 - 8)
Relay output (C, NC and NO)
Antenna connection
SIM card holder
Speaker volume dip-switches
NAMEPLATE ILLUMINATION JUMPER JP2
The nameplate LED illumination jumper JP2 is located behind the GSM module’s
front facia, shown in Fig.7,
. To access the jumper the facia must be removed
and the jumper can be adjusted as required. When JP2 is set in position A (upper
2 pins) the LED is set for bright illumination, when JP2 is set in position B (lower
2 pins) the LED is set for low illumination and if JP2 is completely removed this
will disable the nameplate LED’s, see Fig.8.
JP2JP2JP2
4000 Series GSM Lite Audio Intercom - Technical Manual
- 10 -
Fig. 8
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Art. 4811 Technical Information
TERMINAL CONNECTIONS
TerminalDescription
+12V12 - 24Vdc or ac power.
0V0V ground power.
AO1Auxiliary output (open collector, 150mA max.).
CCommon relay contact.
NCNormally closed relay contact.
NONormally open relay contact.
gGSM function terminals: Resets, PTE and auxiliary inputs.
Auxiliary input 2, connects across g-4 (sends an SMS message to the master number, also see Fig.22, page 21).
Auxiliary input 1, connects across g-5 (activates AO1 when A1M set to mode 01, also see Fig.17, page 18).
1 - 8
JP2Nameplate window LED illumination adjustment. JP2 position A = LED bright,
TECHNICAL SPECIFICATION
Working Voltage:12 - 24Vdc or ac +/- 10%
Standby Current:approx. 60mA
Max. Current:approx. 500mA (max.)
Call Buttons:up to 4 (max.)
Telephone Numbers per Button: 2 telephone numbers (1 primary, 1 divert)
Dial to Open Numbers:up to 100 (max.)
Programming Method:SMS messaging or the Videx SMS Wizard app
Push to Exit Input:1 (push-to-make, across terminals g-6)
Auxiliary Inputs:2 (A1 = across terminals g-5, A2 = across terminals g-4)
Auxiliary Output:1, AO1 (open collector output, switched 0V, 150mA max.)
Dry Contact Relay:C, NC and NO, 3A @ 24Vdc, 3A @ 120Vac
Working Temperature:-10 +50
PTE input, push-to-make (switched 0V), connects across g-6 (also see Fig.14, page 16).
4 digit master code (1111) reset, connects across g-7 (also see Fig.37, page 26).
Full reset, connects across g-8 (also see Fig.40, page 26).
JP2 position B = LED low, JP2 removed = LED disabled.
o
C
Relay contacts:
3A@24Vdc
3A@120Vac
4000 Series GSM Lite Audio Intercom - Technical Manual
- 11 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Art. 4901 Technical Information
ART. 4901 CODELOCK MODULE
103mm
120mm
4901
STEEL
ALI
HIGH BRASS
MATTE
Note: Remove MOV
jumper completely
when using a relay to
trigger a gate controller.
MOV
NO3NC3
NO2NC2
NO1NC1
Fig. 9
DESCRIPTIONLEGEND
The codelock module, Fig.9, features 12 stainless steel buttons, backlit in blue
(keys 0 - 9, ENTER
and CLEAR ), 2 LED’s for progress information during
use and programming. With three integral relays (RLY1, RLY2 and RLY3) each
with C, NO and NC connections and two switched 0V push to exit inputs (SW1
and SW2) to enable the external triggering of relays 1 and 2 only.
Key presses are signalled both acoustically and visually, while each button press
has a tactile feel. Entering the correct code followed by ENTER
will activate
the relevant relay. Programming is carried out through the same keypad
following a simple programming menu (refer to programming owchart on
Accept LED (green)
Key buttons (0 - 9, ENTER and CLEAR)
Program/error LED (red)
Backlight adjustment jumper (JPL)
PTE terminals (SW1 and SW2)
Relay terminals (RLY1, RLY2 and RLY3)
Power input terminals (+ / -)
Back EMF protection jumpers
page 14).
RELAY BUILTIN BACK EMF PROTECTION JUMPERS
The codelock includes selectable back EMF protection (metal oxide varistors)
jumpers for each relay (marked MOV) and are used to select the protection type.
When using a fail secure lock with connections C & NO the jumper should be in
the NO position for the selected relay (RLY1, RLY3 or RLY3).
When using a fail open (safe) lock with connections C & NC the jumper should
be in the NC position for the selected relay (RLY1, RLY3 or RLY3).
When using the codelock to trigger a gate controller or another third party
controller the respective jumper should be removed completely (this disables
the protection on the relay), as shown in Fig.10
NO position for fail
secure lock release
Fig. 10
NC position for fail
safe lock release
removed for
gate controls
PROGRAMMING THE KEYPAD
All programming is carried out using the keypad. The programming menu is protected by an ENGINEER’S CODE, the factory default
of which is 6x1 (“111111”). This code can be changed to any 4 to 8 digit ENGINEER’S CODE during the programming and is used to
gain entry to the programming menu only.
Each relay (RLY1, RLY2 and RLY3) can be programmed with a 4 - 8 digit access code (one code per relay) and will activate the
respective relay for the programmed relay time (01 - 99 seconds or 00 for latching). The access code programmed is stored in the
keypads internal memory.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 12 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Art. 4901 Technical Information
BACK LIGHT ADJUSTMENT JUMPER JPL
The jumper JPL (Fig.9,
brightness settings for the backlit buttons and two programming modes (mode 1 and 2) for the jumper.
The two modes that can be programmed change the functionality of the jumper JPL. The table below indicates the programming
mode, the position of the jumper and the operation of the backlit buttons.
Jumper PositionBack light Operation
A
Mode 1
B
(default)
A or B
Mode 2
JPL removed in
either Mode
) is used to adjust the brightness and determine the operation of the backlit buttons. There are four
A
Back light OFF in standby. Full brightness when any buttons are pressed.
B
A
Back light on low brightness in standby. Full brightness when any buttons are pressed.
B
A
B
or
A
Back light on full brightness all of the time.
B
A
No back light, the back light is completely disabled.
B
PROGRAMMING MODE 1 DEFAULT MODE, JPL = B
Follow the steps below to set the codelock to mode 1:
1. Disconnect the power from the Art.4901 codelock;
2. Short out terminals - and SW2;
3. Press and hold down button 1
and keep it pressed down
while the power is switched back ON;
4. When power is restored to the codelock wait for the module
to emit a single beep and the red program LED (Fig.9,
ash once;
5. Listen for the conrmation tone and wait for the red program
LED (Fig.9,
6. Release button 1
) to ash once again;
and remove the short between terminals
- and SW2;
7. Set the jumper JPL to the desired position.
PROGRAMMING MODE 2
Follow the steps below to set the codelock to mode 2:
1. Disconnect the power from the Art.4901 codelock;
2. Short out terminals - and SW2;
3. Press and hold down button 2
and keep it pressed down
while the power is switched back ON;
4. When power is restored to the codelock wait for the module
) to
to emit a double beep and the red program LED (Fig.9,
to ash once;
5. Listen for the conrmation tone and wait for the red program
LED (Fig.9,
6. Release button 2
) to ash once again;
and remove the short between terminals
- and SW2;
7. Set the jumper JPL to the desired position.
BACK LIGHT AND BUTTON OPERATION
If the back light programming mode is set to mode 1 (with jumper JPL in either the A or B position) when a button is pressed on the
keypad the back light will switch to full brightness for approximately 10 seconds.
After this time the back light will either switch OFF or switch back to low brightness (depending on the jumper position) unless
another button has been pressed within the 10 second period in which case the back light will stay on full brightness for a further
10 seconds.
The exception to this is if the back light programming mode is set to mode 2, i.e. the back light will be on full brightness all of the
time or if the jumper is removed the back light will be disabled.
OPERATION
• Type in the programmed access code and press ENTER to conrm;
• If the access code is correct, the green accept LED (Fig.9,
) will illuminate for approx. 2 seconds and the relay that is relevant to
the code will operate for the programmed relay time;
• If an incorrect access code is entered, a continuous melody will sound for 4 or more seconds, according to the number of mistakes
and the red program/error LED (Fig.9,
) will illuminate.
OPERATION NOTES
• To operate the relays together, set the same code for each relay;
• If an incorrect code is entered, the system will lock out for 5 seconds which will increase each time an incorrect code is entered.
The system will only operate when the correct code is entered.
)
4000 Series GSM Lite Audio Intercom - Technical Manual
- 13 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Art. 4901 Technical Information
PROGRAMMING GUIDE
• Enter the ENGINEER’S CODE: rst time type six times 1 (111111
factory default) and press ENTER(the red LED will illuminate);
• Conrm ENGINEER’S CODE: re-type the same code again or
type a new code (4 to 8 digits) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 1 then press ENTER (melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 2 then press ENTER (melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 3 then press ENTER (melody);
• Enter the RELAY 3 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• The system is ready to use (the red LED will switch OFF).
PROGRAMMING NOTES
• Pressing the ENTER button twice during the programming
process, without changing any parameters, will exit from the
programming menu.
• When entering a relay code it must be dierent from the
ENGINEER'S CODE.
• To latch the relay type in the access code then press ENTER
to conrm. To unlatch the relay type in the same access code
again then press CLEAR to conrm.
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
• Turn OFF the power to the codelock;
• Keep the ENTER button pressed while the power is turned
back ON;
• Release the ENTER button;
• The ENGINEER’s CODE is now reset back to 6x1 (“111111”).
Press ENTER
(red LED ON)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
ENTER THE
“ENGINEER’S CODE”
CONFIRM
OR CHANGE
“ENGINEER’S CODE”
ENTER
“ACCESS 1 CODE”
ENTER
“ACCESS 1 TIME”
ENTER
“ACCESS 2 CODE”
ENTER
“ACCESS 2 TIME”
ENTER
“ACCESS 3 CODE”
ENTER
“ACCESS 3 TIME”
SYSTEM
READY TO USE
Press 1 six times
“111111”
(factory default)
Press 1 six times
“111111” again or
type new engineer’s
code (4 to 8 digits)
Type code to enable
relay 1 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Type code to enable
relay 2 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Type code to enable
relay 3 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
red LED OFF
TERMINAL CONNECTIONSTECHNICAL SPECIFICATION
ConnectionDescriptionWorking voltage:12V - 24Vac/dc +/- 10%
+12-24V AC or DC power inputCurrent consumption:20mA (standby); 70mA (max.)
-0V power inputNumber of relays:3, RLY1, RLY2 & RLY3 (C, NC and NO)
C1Relay 1 common connection
NO1Relay 1 normally open connectionPush to exit inputs:2, SW1 and SW2 (switched 0V)
NC1Relay 1 normally closed connectionBack EMF protection:Yes, 3x MOV jumpers
3A @ 4Vac⁄dc (max)
Relay contacts:
Relay current ⁄ voltage: 3A @ 24Vac/dc (max.)
C2Relay 2 common connectionNumber of codes:3 codes (1 code per relay)
NO2Relay 2 normally open connectionProgramming:Via keypad
NC2Relay 2 normally closed connectionWorking Temperature:-10 +50
o
C
C3Relay 3 common connection
NO3Relay 3 normally open connection
NC3Relay 3 normally closed connection
SW1Switched 0V PTE input to trigger relay 1
SW2Switched 0V PTE input to trigger relay 2
4000 Series GSM Lite Audio Intercom - Technical Manual
- 14 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Wiring Diagrams
LTGSM4K CONNECTIONS
Fig.11 shows the wiring connections for a LTGSM4K-1/LTGSM4K-1S audiokit with a fail secure lock release.
GSM
INTERCOM
Art.4811
12Vdc
FAIL SECURE
LOCK RELEASE
Fig. 11
Fig.12 shows the wiring connections for a LTGSM4K-1/LTGSM4K-1S audiokit with a fail safe lock release and Fig.13 shows volt free
wiring connections for a set of gate controls using the Art.120 pcb (supplied with the GSM LITE audiokits).
GSM
INTERCOM
Art.4811
To Antenna
GSM
INTERCOM
Art.4811
To Antenna
VOLT FREE CONTACTS
12Vdc
TO GATE CONTROLS
FAIL SAFE
LOCK RELEASE
Fig. 12 Fig. 13
4000 Series GSM Lite Audio Intercom - Technical Manual
- 15 -
WHENEVER VOLT FREE CONTACTS ARE
REQUIRED TO OPERATE A SE T OF GATE
CONTROLS THE ART.120 PCB (SUPPLIED
WITH THE LTGSM4K/LTGSM4KC KIT)
SHOULD BE USED.
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Wiring Diagrams
CONNECTING A PUSH TO EXIT BUTTON AND A BREAK GLASS UNIT
The push to exit button must be congured as a “push-to-make” switch and connected across terminals g & 6 on the Art.4811 GSM
LITE module. The break glass unit, congured as a “push-to-break”, would only be used when connecting a fail safe/fail open lock
release (e.g. a mag lock) and would connect in series with the GSM’s relay connections C and NC, as shown in Fig.14.
When the exit button is pressed the GSM relay will trigger for the programmed relay time. When the break glass unit is activated it
will break the power to the mag lock.
EMERGENCY
GSM
INTERCOM
Art.4811
DOOR RELEASE
Emergency Break Glass
12Vdc
MAG LOCK
14-20V
MOV
Fig. 14
IMPORTANT NOTE: In instances where the current draw of the lock (fail secure or fail safe) exceeds the current rating of the
HDR15-12 (1.25A) power supply a separate power supply with a sucient current rating will be required to power the lock.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 16 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Wiring Diagrams
LTGSM4KC CONNECTIONS
Fig.15 shows the wiring connections for a LTGSM4KC-1/LTGSM4KC-1S audiokit with a fail secure lock release wired through the relay
contacts (RLY1) of the Art.4901 codelock. Also shown is the wiring conguration for a fail safe lock and volt free connections for a set
of gate controls using relay 1 (RLY1) of the Art.4901 codelock.
MOV jumper for RLY1
moved to NC position
switched 0V through C/NO
from GSM’s relay to SW1
on codelock.
12Vdc FAIL SAFE
LOCK RELEASE
Art.4901
GSM
INTERCOM
Art.4811
0V from PSU
+12Vdc from PSU
MOV jumper for RLY1 removed
switched 0V through C/NO
from GSM’s relay to SW1
on codelock.
VOLT FREE CONTACTS
TO GATE CONTROLS
Art.4901
0V from PSU
+12Vdc from PSU
Art.4901
MOV jumper for RLY1
moved to NO position
Fig. 15
4000 Series GSM Lite Audio Intercom - Technical Manual
- 17 -
MOV
NO3NC3
NO2NC2
12Vdc
NO1NC1
FAIL SECURE
LOCK RELEASE
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Auxiliary Inputs/Outputs
AUXILIARY OUTPUT AO1
The auxiliary output AO1 has six modes 00 - 05 and is set using the A1M command (refer to page nn for full list of A1M programming
modes). It is an open collector output (switched low, 150mA max.) and depending on the mode it is set to will determine how the
AO1 output behaves. The following examples show how the AO1 output can be connected.
AO1 SET TO MODE 00, ‘CALL ACTIVATED’
When set to mode 00 auxiliary output AO1 will activate when the call begins and deactivate when the call ends, as shown in Fig.16.
GSM
INTERCOM
Art.4811
AO1 output will activate
for the duration of the call
Fig. 16
AO1 SET TO MODE 01, ‘USER ACTIVATED’
When set to mode 01 auxiliary output AO1 will activate when the terminals g & 5 are shorted together on the GSM LITE module or
by pressing 6 on the telephone during a call, as shown in Fig.17. Auxiliary output AO1 will only activate for the programmed time.
To Antenna
Fig. 17
GSM
INTERCOM
Art.4811
To Antenna
OR
AO1 output will activate
for the programmed time
4000 Series GSM Lite Audio Intercom - Technical Manual
- 18 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Auxiliary Inputs/Outputs
AO1 SET TO MODE 02, ‘STATUS INDICATION’
When set to mode 02 auxiliary output AO1 is used exclusively as a monitoring input. For example, checking if a gate/door is open
or closed. Once set the AO1 input status can be interrorgated in two ways:
1. During a call: press 9 on the telephone keypad and listen to the number of beeps in the ear piece. One beep indicates the input
is CLOSED and two beeps indicates the input is OPEN.
2. At anytime: send the SMS message 1111CHK? to the GSM LITE intercom. An SMS message will be returned with IN=OP for
OPEN or with IN=CL for CLOSED.
For this feature an additional relay will be required and the AO1 input must be wired as shown in Fig.18.
To Antenna
GSM
INTERCOM
Art.4811
12
OR
Fig. 18
AO1 SET TO MODE 03, ‘DIVERT CALLS TO MASTER NUMBER’
It is possible to have the GSM LITE call buttons diverted to the master number when auxiliary output AO1 has been set to mode 03
(auxiliary output AO1 is used as a monitoring input). In this instance a switched common and normally open (CO/NO) trigger needs
to be used to enable or disable ‘divert calls to master number’ and the auxiliary output AO1 must be wired as shown in Fig.19. In
either case a master number is required following the STM store master number feature (see STM programming notes on page 36).
If there is no master number stored the GSM LITE intercom will indicate this with a series of beeps and no call will take place.
GSM
INTERCOM
Art.4811
To Antenna
Normally open (NO) switched input to
enable and disable divert to master number
Fig. 19
4000 Series GSM Lite Audio Intercom - Technical Manual
- 19 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Auxiliary Inputs/Outputs
AO1 SET TO MODE 04, ‘CALL ACTIVATED TIMED’
Similar to mode 00, however, when set to mode 04 auxiliary output AO1 will activate when the call begins and deactivate when the
auxiliary output time, A1T, expires, see Fig.20.
The auxiliary output time can be set using the SMS programming code 1111A1Tnn? (where nn = time in seconds, also refer to notes programming the GSM intercom on pages 29 - 40).
GSM
INTERCOM
Art.4811
AO1 output will activate
for the programmed time
Fig. 20
To Antenna
AO1 SET TO MODE 05, ‘ENABLE/DISABLE DIAL TO OPEN NUMBERS’
When the auxiliary output AO1 mode is set to 05 the dial to open numbers (DTO) will only activate the GSM LITE’s relay when a
common and normally open (CO/NO) switch connected across terminals g & AO1, as shown in Fig.21, is open circuit. When the
switch is CLOSED and terminals g & AO1 are short together this will disable the dial to open numbers (DTO).
GSM
INTERCOM
Art.4811
Fig. 21
To Antenna
Normally open (NO) switched input to
activate and deactivate dial to open numbers
IMPORTANT NOTE: When auxiliary output AO1 is set to a particular mode (00 - 05) it cannot be used as an input/output for
anything else.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 20 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Auxiliary Inputs/Outputs
AUXILIARY INPUT 2
Auxiliary input 2 connects across terminals g & 4 on the GSM LITE module. When this input is triggered it will send an SMS message
to the master telephone number, as shown in Fig.22, (to store a master number STM follow the programming notes on page 36.
Once this input is triggered it cannot be triggered again for up to 4 minutes, this is to avoid multiple SMS messages being sent for
the same alarm.
GSM
INTERCOM
Art.4811
Fig. 22
4000 Series GSM Lite Audio Intercom - Technical Manual
- 21 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
General Directions for Installation
CABLE SIZE GUIDE
POWER SUPPLY AND LOCK RELEASE CONNECTIONS
Refer to the table below for the connections for the power supply output to the Art.4811 GSM LITE intercom and the lock release
connections.
Distance 20m50m100m
Cross Sectional Area (CSA)0.5mm
Ideally the power supply should be located as close to the intercom panel as possible for best performance. The maximum
acceptable resistance for the above cables = 3 or less for best possible performance.
IMPORTANT NOTE: Only bare copper (BC) cable should be used (solid or stranded is acceptable). Please be aware that when
selecting a cable the following should NOT be used: Copper Coated Steel (CCS) and Copper Clad Aluminium (CCA). While these
types of cable may oer a low cost solution they will have a higher resistance than pure copper cable and can aect the overall
performance of the system therefore Videx DO NOT recommend these types of cable.
GENERAL INSTALLATION NOTES
• Check that all components are free from damage before installing (do not proceed with installation in the event of damage).
• Keep all packaging away from children (please dispose of any excess waste and packaging responsibly).
• Do not obstruct the ventilation openings or slots on any of the devices.
2
1.0mm
2
1.5mm
2
• All connections to mains voltages must be made to the current national standards (I.E.E. wiring regulations for the UK or the
appropriate standards of your country if installing overseas).
• Install an appropriate fused spur or isolation switch to isolate the mains.
• Isolate the mains before carrying out any maintenance work on the system.
• Avoid water ingress into the rear of the module, always seal the module frame after installation using a suitable silicon based
sealant.
• All intercom and access control cables must be routed separately from the mains (ideally in a separate cable tray or duct).
LOCK RELEASE WIRING AND BACK EMF PROTECTION
When tting an electric lock release back EMF protection will be required. If tting an AC lock release then a 100nF ceramic disc
capacitor should be tted across the terminals of the lock, shown in Fig.23. If tting a DC lock release (fail secure or fail safe) then
a 1N4002 diode should be tted across the terminals on the lock, shown in Fig.24.
+
100nF CAP
1N4002 DIODE
-
Fig. 23Fig. 24
If a 100nF ceramic disc capacitor or a 1N4002 diode are not available then a 14 - 20V MOV (metal oxide varistor) can be tted across
the lock terminals instead (refer to Fig.23 above) and can be tted on both an AC and DC lock. Connection examples can also be
seen on the various wiring diagrams on pages 15 - 17.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 22 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
General Directions for Installation
CONNECTION TO MAINS, SAFETY AND GUIDANCE NOTES
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING WITH THE INSTALLATION.
IMPORTANT: IT IS RECOMMENDED THAT ANY CABLING AND VIDEX PRODUCTS BE INSTALLED BY A COMPETENT
AND QUALIFIED ELECTRICIAN, SECURITY INSTALLATION SPECIALIST OR COMMUNICATIONS ENGINEER.
• DO NOT install any Videx product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or ammable gases, liquids or vapours.
• Possible obstructions which would prevent or hinder the access and/or removal of the Videx product.
MAINS CONNECTION
The system MUST be installed in accordance with the current I.E.E. regulations (in particular I.E.E. Wiring regulations BS7671 for the
UK), or the appropriate standards of your country if installing overseas, in particular Videx recommends:
• Connecting the system to the mains through an all-pole
circuit breaker (refer to Fig.25) which shall have contact
separation of at least 3mm in each pole and shall disconnect
all poles simultaneously.
N
• That the all-pole circuit breaker shall be placed in such a
way to allow for easy access and the switch shall remain
readily operable.
• Ensuring that the mains supply (Voltage, Frequency and
Phase) complies with the product rating label (this is usually
located on the topside of the power supply).
• Isolating the mains before carrying out any maintenance
work on the system.
POWER SUPPLY INSTALLATION
Follow the steps below when tting the HDR-15-12 (12Vdc 1.25A) power supply.
• Fix the power supply to a DIN rail (following Fig.26, Fig.27 and Fig.28).
• Switch OFF the mains using the circuit breaker (mentioned previously) and then make the connections as required shown on
the various wiring diagrams throughout this manual.
• Check the connections and secure the wires into the terminals ensuring that the low voltage (signal) cables are routed separately
from the high voltage (mains) cables.
• If applicable replace the terminal covers and x them back into place using the relevant screws.
• When all connections are made restore the mains supply.
SUPPLY
(220 - 240Vac,
50/60Hz)
Fig. 25
1 PHASE
FUSE
L
SWITCHED
FUSE SPUR
Fig. 26 Fig. 27 Fig. 28
4000 Series GSM Lite Audio Intercom - Technical Manual
- 23 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
General Directions for Installation
PANEL CARE
The door panel’s facia is either a stainless steel mirror or matt nish, or matt nish aluminium.
It is important that the facia is cleaned on regular occasions to prevent dirt build up and
tarnishing of the metal.
A clean and soft cloth can be used with moderate warm water or non-aggressive cleansers.
Additional care should be taken to follow the grain of the metalwork when polishing panels
with a matt nish and always only polish in one direction to avoid light scratching of the
plate, see Fig29. Also try to avoid any polish build up around the panel’s buttons which may
prevent the buttons from operating correctly.
DO NOT USE ANY OF THE FOLLOWING:
• Abrasive liquids;
• Chlorine-based liquids;
• Metal cleaning products (including Sidol stainless steel cleaner as this can aect the
etching and/or engraving);
• Hydrochloride bleaches.
IMPORTANT NOTE: IT IS IMPORTANT TO REGULARLY MAINTAIN THE “UP KEEP” OF THE GSM LITE PANEL CLEANING
AND GENERAL MAINTENANCE ETC. ANY FAULT OR DAMAGE THAT MAY OCCUR TO THE GSM LITE PANEL DUE TO
THE LACK OF CLEANING AND MAINTENANCE IS NOT THE RESPONSIBILITY OF VIDEX.
Fig. 29
4000 Series GSM Lite Audio Intercom - Technical Manual
- 24 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Fitting the SIM & Connecting Power
FITTING THE SIM CARD AND CONNECTING THE POWER TO THE GSM INTERCOM
After connecting the power supply, antenna, lock output and any auxiliary devices as shown in this manual and before powering up,
a SIM card must be installed (the SIM must already be registered with the network provider). The SIM holder can be found on the back
of the module under the SMA antenna connection. A SIM card from most network providers can be used (remember a network 3 SIM will only work with the 3G version of the GSM LITE intercom). Follow the steps below to insert the SIM card.
FITTING THE SIM
1. On the back of the Art.4811 GSM LITE module slide the
SIM holder to the left until it ‘clicks’, as shown in Fig.30.
2. The SIM holder is hinged and will open out to the left,
see Fig.31.
3. Place the SIM card into the holder (it will only t one way,
see Fig.32) and fold the holder back down, see Fig.33.
4. Slide the SIM holder back to the right until it ‘clicks’, see
Fig.34.
5. Once the SIM is in place connect the Art.432 GSM antenna
and then connect the 12Vdc power supply but DO NOT
power up the system yet.
Fig. 30Fig. 31
6. Follow the initialisation process described below.
Fig. 32 Fig. 33
Fig. 34
POWER UP INITIALISATION SEQUENCE
The Art.4811 GSM LITE module requires approximately 30 seconds to initialise properly. We
recommend NOT sending any SMS messages or pressing buttons during this time.
1. First check all the necessary connections have been made correctly, following the wiring
diagrams shown in this manual, and when ready power up the system.
2. Two short beeps will be heard from the GSM LITE module followed by a 15 second delay,
as shown Fig.35.
3. Next a single short beep will be heard every second while the GSM module attempts to
register with the chosen network, as shown in Fig.36, this will continue until the GSM LITE
module has made a connection to the network.
4. Wait for the beeping to stop to indicate that the GSM LITE module has registered with the
network.
5. The GSM LITE intercom is ready to be programmed.
...delay 15 secs...
Fig. 35
...1 sec...
...1 sec...
...registering...
Fig. 36
4000 Series GSM Lite Audio Intercom - Technical Manual
- 25 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Reset Procedure
RESETTING THE GSM MODULE TO FACTORY DEFAULTS
There are two ‘hard-wired’ reset options available. The rst will reset the master code (1111) only and the second will reset everything
and clear all the stored telephone numbers (primary, divert and dial to open) and all settings.
RESETTING THE MASTER CODE TO 1111 4x1
1. Power down the GSM LITE intercom module.
2. Put a short across terminals g & 7 on the back of the GSM
LITE module, as shown in Fig.37.
3. Power up the GSM LITE module, 2 beeps will be heard
followed by a brief delay and then a 3rd beep, as shown in
Fig.38.
4. After the 3rd beep remove the short, as shown in Fig.39.
5. The master code is now reset back to 1111 (4x1).
FULL SYSTEM RESET
1. Power down the GSM LITE intercom module.
2. Put a short across terminals g & 8 on the back of the GSM
LITE module, as shown in Fig.40.
3. Power up the GSM LITE module, 2 beeps will be heard
followed by a brief delay and then a further 2 beeps, as
shown in Fig.41.
Fig. 37
...delay...
Fig. 38
Fig. 39
Fig. 40
4. After the 4th beep remove the short, as shown in Fig.42.
5. All settings on the GSM LITE module are returned to
factory defaults.
...delay...
Fig. 41
Fig. 42
4000 Series GSM Lite Audio Intercom - Technical Manual
- 26 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
4000 Series Back Box Installation
EXAMPLE: INSTALLING A 4000 SERIES FOUR MODULE BACK BOX
C
Fig. 43 Fig. 44 Fig. 45
Y
G
H
B
F
G
Fig. 46 Fig. 47 Fig. 48 Fig. 49
C
A
C
E
D
D
C
W
C
H
M
L
L
H
M
M
Fig. 50 Fig. 51 Fig. 52
Q
P
H
N
PO
N
N
Fig. 53 Fig. 54 Fig. 55 Fig. 56
Fig. 57 Fig. 58 Fig. 59 Fig. 60
4000 Series GSM Lite Audio Intercom - Technical Manual
- 27 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
4000 Series Back Box Installation
INSTALLING A SURFACE MOUNT DOOR STATION
1. Place the surface box against the wall (165-170cm between the top of the box and the oor level as shown in Fig.43), mark the xing
A
holes
2. As shown on Fig.44, drill the xing holes A, insert the wall plugs B and feed the cables E through the surface box opening D,
x surface box C to the wall using the screws F;
3. Apply the
4. Before installation of the module support frame, hook the modules
in Fig.48, t the two anti-tampering locks
5. When you have more than one support frame, hook the support frame to the surface box starting from the left. For convenience we
will describe how to attach the left frame but the same procedure must be carried out for the right frame. As shown in Fig.49, hook the
module support frame
the pivots L (Fig.49) go inside the relevant hinge housing M as shown in Fig.50;
6. As shown on Fig.51, pull back the module support frame
7. As shown in Fig.52, open the module support frame
M
adjusting the settings (through openings
8. Repeat the same steps described above for the second module support frame (or for the third if available);
9. When the system has been tested and is working correctly, move back the module support frames carefully, x them to the surface box
using the screwdriver provided
than is necessary.
INSTALLING A FLUSH MOUNTING DOOR STATION
for the wall plugs B and the hole for the cables E (Fig.44). Observe the orientation of the box with the hinge on the left;
In order to prevent water ingress we highly recommend using a silicon sealant between the wall and the back box
C
, ON THE LEFT, TOP AND RIGHT SIDES ONLY AND AROUND ALL HOLES D. DON’T USE SILICON SEALANT ON THE
BOTTOM SIDE OF THE BACK BOX (Fig.45);
Y
neoprene seal on top of each module G as shown in Fig.46;
G
to the support frame H as shown in Fig.47 then, as shown
W
for each module (do the same for the second module support frame);
H
(complete with modules) to the surface box C moving the frame as suggested from the pointers. Ensure that
H
while moving it slightly to the left as suggested by the pointers;
H
as suggested by the pointer, hook the hinge locks N to the hinge housings
, make the required connections using the screwdriver provided P (at blade end) and make the required adjustments by
O
) and adjust trimmers;
P
(torx end) and the pin machine torx screws Q (Fig.53). Note: do not over tighten the screws more
When ush mounting and the number of modules is greater than 3, the required back boxes need to be linked together (before
embedding them into the wall) as shown on Fig.56, Fig.57 and Fig.58:
• Arrange the back boxes and remove knockouts to allow cables to be fed from one back box to the other;
• Hook the spacers to the rst back box then hook the second back box to obtain the result shown on Fig.58;
1. Protect the module support frame xing holes from dust then embed the back box into the wall (165-170cm between the top of
the box and the oor level as shown on the Fig.43) feeding the cables
E
(Fig.44) through a previously opened hole in the box.
Observe the direction of the box ensuring the hinge is on the left and take care that the box prole is in line with the nished
wall prole;
In order to prevent water ingress we highly recommend using a silicon sealant between the module support frame
H
and the back box C, ON THE LEFT, TOP AND RIGHT SIDES ONLY. DON’T USE SILICON SEALANT ON THE BOTTOM
SIDE OF THE MODULE SUPPORT FRAME (Fig.54);
2. Continue from step 4 of surface mounting instructions, but at step 7 hook the hinge locks N as shown on Fig.55.
Note: if additional holes are made in the surface box, oxidation problems may appear unless the unprotected metal is
coated with a protective paint.
NOTES
• The screwdriver’s blade has two sides, one at and one torx, to select one of them unplug the blade from the screwdriver body
and plug it into the required side.
• The example shows the use of only one back box bottom hole for wires, this is done to keep le drawings clear. Naturally the
installer can use the left hole or the right or both if required.
HOW TO REMOVE THE CARD NAME HOLDER
• To avoid damage to the module front plate, tape the side that will be in contact with the screwdriver blade;
• lnsert the screwdriver (at side) into the card-holder hole as shown in Fig.59;
• Move the screwdriver to the left as shown in Fig.60 to extract the card name holder;
• Edit the card name then replace it inside the holder and ret: insert the holder inside its housing from the left or right side then
push the other side until it clips into place.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 28 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
PROGRAMMING THE GSM INTERCOM
Programming the GSM LITE intercom can be carried out by sending text (SMS) messages to the module.
IMPORTANT NOTE: When you are required to use “ in a text message it is very important to use the correct symbol and not for
example ‘ (or two ‘ single apostrophes side by side which you will see look the same but will be interpreted dierently by the
GSM LITE intercom panel).
PROGRAMMING BY TEXT MESSAGE
Programming by text message is a simple way to customise the settings of the GSM LITE intercom panel and add or delete telephone
numbers. Simply send texts in the following format shown below to the telephone number of the SIM within the GSM LITE intercom
panel:
Store a primary telephone no.STN1111STNnnn”01912243174”nnn = 001 - 004n/a30
Store divert telephone no.STD1111STDnnn”01912241559”nnn = 001 - 004n/a30
Store a primary telephone no.
and divert no in a single text
message
Store a dial to open no. (DTO)
or
Store up to 5 dial to open no’s
(DTO) in a single text message to
the next available locations
Delete a dial to open no. without
knowing it’s location
Set call timeSPT1111SPTnnnn = 01 - 1202 (40s)33
Set relay timeRLT1111RLTnnnn = 00 - 9905 (5s)33
Set auxiliary AO1 output timeA1T1111A1Tnnnn = 00 - 9905 (5s)33
Set auxiliary AO1 out modeA1M1111A1Mnnnn = 00 - 050133 - 34
Keep connection facilityNOD1111NODnnnn = 01 - 990 (disabled)34
Divert to next no. timeDIT1111DITnnnn = 01 - 9915 (15s)34
Check GSM signal strengthSIG1111SIG?n/an/a34
Check software versionVER1111VER?n/an/a34
Dial a numberDLE1111DLE”123”n/an/a34 - 35
Store SMS message for g-4SMS1111SMS”HouseAlarm”n/aAUX TRIG35
Change 4 digit codeCDE1111CDE1234Any 4 digits111135
Trigger the relayRLY1111RLYn/an/a35
Trigger the auxiliary output AO1 A1O1111A1On/an/a35
Store balance check dial stringSDL1111SDL”*#1345#”n/an/a35
Check credit balanceBAL1111BAL?n/an/a35 - 36
Store master telephone no.STM1111STM”07771234567”n/an/a36
Latch the relayRLA1111RLAn/an/a36
Unlatch the relayRUL1111RULn/an/a36
Latch the auxiliary AO1 outputA1L1111A1Ln/an/a36
Unlatch the auxiliary AO1 output A1U1111A1Un/an/a36
Input status check and setCHK1111CHK?n/an/a36 - 37
Silent dialling modeAUE1111AUEnnnn = 00 or 010137
This code prevents unauthorised access to the programmable features of the system. The code must
be four digits long but can be any combination using digits 0 – 9. The default code is 1111 and will
be used for all examples in this manual.
The 3 digit function code identies the programmable feature to be changed. The code must be in
capital letters. The following table lists the available codes.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 29 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
Send tone after answer (But 1)DTP1111DTPnn = 0 - 9 or XX37
Send tone after answer (Div 1)DTD1111DTDnn = 0 - 9 or XX37
Send DTMF tone delayDTT1111DTTnnnn = 01 - 120337
Enable dial 0 on answer function EDZ1111EDZnn?nn = 00 or 010037 - 38
Enable # (hash) functionED#1111ED#nn?nn = 00 or 010038
Find a telephone numberFDT1111FDT” number or ends in”n/an/a38
End on Last DivertEOD1111EODnn?nn = 00 or 010038
Shutdown and RestartRBT1111RBTn/an/a39
Simulate button press via SMSBUT1111BUTnnnn = 01 - 50n/a39
Initiate a special commandPRG1111PRG(command)AT commandsn/a39
AT command to send at start up AT 11111AT1”ATxxxxxx”?Any AT commandn/a39
AT command to send at start up AT 21111AT2”ATxxxxxx”?Any AT commandn/a39
AT command to send at start up AT 31111AT3”ATxxxxxx”?Any AT commandn/a39
Obtain the GSM’s IMEI numberIME1111IME?n/an/a39
Unlatch prevention featureLLA1111LLAnn?nn = 00 or 010040
OPTIONAL DATA
OPTIONAL ?
When sending text messages there may be a delay from when you send the message to when it is received by the GSM LITE
depending on how congested the network is. If you are at the intercom panel when sending the message you will hear a single
beep from the GSM LITE intercom to indicate it has received the message.
STORING THE CALL BUTTON TELEPHONE NUMBERS STN AND STD
Telephone numbers can be stored for the 4 available call buttons. Each call button can call two telephone numbers, if the rst
number is busy or not answered in a certain time it can call a second number if the divert facility is setup. The STN code stores the
rst number called (primary number) when the button is pressed, while the STD code stores the second number to be called (divert
number) if the rst is busy or not answered. The messages to store/check numbers are as follows (replace STN with STD when
storing/checking divert number).
1111STNnnn”yyyyyyyyyyy”Store the primary telephone number yyyyyyyyyyy in position nnn.
1111STNnnn”yyyyyyyyyyy”?Store the telephone number yyyyyyyyyy in position nnn and send a conrmation text
1111STNnnn?Query the telephone number stored in location nnn. A text message will be sent to the
1111STNnnn””Delete the telephone number stored in location nnn.
1111STNnnn””?Delete the telephone number stored in location nnn. A text message will be sent to the
nnn is a button number between 001 and 004. The telephone number y can be a maximum of 30 digits. For example: to store the
number 01912243174 for button 2 and a divert number (if the rst one is not answered or busy) of 01912241558, the two SMS
messages would be sent to the GSM intercom:
IMPORTANT NOTE: When sending the command 1111STNnnn? to query the telephone number stored for the call button the
GSM LITE will reply with the list of all the numbers stored for that call button i.e. the primary number and the divert number as
shown in the example below *.
STORING THE PRIMARY AND DIVERT NUMBER IN A SINGLE TEXT MESSAGE USING STN
It is also possible to program the primary telephone number and the divert number for a particular call button in a single text
message instead of using the individual programming codes STN and STD for the numbers. Expanding on the STN programming
command the text messages used to store/check the primary number and divert number are as follows.
The optional data will vary depending on the command used. It may be a telephone number, a time
setting or may not be used at all. For more information refer to the following command settings.
Most of the commands support the ? feature. When this is added to the end of the text message, a
conrmation text message will be sent back to the sender indicating the new data has been received
and stored.
message to conrm storage of new number.
sender with the stored number for that location.
sender with the delete conrmation for that location.
Using the same telephone numbers from the previous example: to store the primary number 01912243174 (pn) for button 1 and
the divert number of 01912241558 (dn), the following single text message would be sent to the GSM intercom instead of sending
two individual text messages:
1111STN001”01912243174”,”01912241558”
Remember an optional ? can be included at the end of the message to receive conrmation of the stored numbers, like so:
1111STN001”01912243174”,”01912241558”?
* The following reply will be received from the GSM LITE:
MEM 001 = 01912243174
MEM (DIVERT 1) 001 = 01912241558
OK VIDEX GSM
Remember to include “ and , where appropriate.
STORING A DIAL TO OPEN NUMBER STR
Dial in door release or dial to open (DTO) allows users to release the door/gate simply by dialling the telephone number of the SIM
in the GSM LITE intercom panel. The intercom panel will check the callers ID when it receives a call and if it matches the list of stored
numbers, it will clear the call down (avoiding the caller being charged for the call) and will activate the relay for the programmed
time. Up to 100 numbers can be stored (000 - 099). The messages to check, store or delete numbers are as follows.
1111STRnnn”yyyyyyyyyyy”Store the telephone number yyyyyyyyyyy in position nnn, where nnn = 000 - 099.
1111STRnnn”yyyyyyyyyyy”?Store the telephone number yyyyyyyyyy in position nnn, where nnn = 000 - 099, and send
a conrmation text message to conrm storage of new number.
1111STRnnn?Query the telephone number stored in location nnn, where nnn = 000 - 099. A text
message will be sent to the sender with the stored number for that location.
1111STRnnn””Delete the telephone number stored in location nnn, where nnn = 000 - 099.
1111STRnnn””?Delete and conrm deletion of a telephone number in location nnn, where nnn = 000 -
099.
IMPORTANT NOTE: It is important to switch OFF voicemail and automatic SMS features on the SIM card in the GSM intercom
when using this feature (see the ‘Forced Dial’ section for more details). Also note that it will not be possible to use the dial in to
speak facility from a number stored to release the door/gate when dialling in (door release takes priority).
Please also note it is important that the number stored, when dialling in to release the door/gate, must have any “caller ID” or
“withhold or witheld number” function switched OFF on the telephone/mobile that is making the call to the GSM intercom. If
this feature is not switched OFF the GSM intercom will not recognise the caller’s number and no further action will take place.
STORING UP TO 5 DIAL TO OPEN NUMBERS IN A SINGLE TEXT MESSAGE TO THE NEXT AVAILABLE LOCATIONS STR
It is also possible to program up to a maximum of 5 dial to open numbers (DTO) at a time to the next available memory locations
and in a single text message instead of programming them individually. Expanding on the existing STR programming command
the text messages used to store/check the dial to open numbers are as follows.
Store the primary number and divert number in position nnn, (where pn
= primary no, dn = divert no and nnn = call button 001 - 004), also send
conrmation of stored numbers for that location.
For example to store the following 5 dial to open numbers (DTO): 01912243174 (n1), 01912241558 (n2), 07771234567 (n3),
01912241559 (n4) and 07897123456 (n5) respectively to start from the next available memory location, the following single text
message would be sent to the GSM intercom instead of sending 5 individual text messages:
Similarly if only 3 dial to open numbers (DTO) n1, n2 and n3 were required, the following message would be sent:
4000 Series GSM Lite Audio Intercom - Technical Manual
Store the dial to open numbers (DTO) to the next available memory location(s),
where n1 = 1st DTO number, n2 = 2nd DTO number, n3 = 3rd DTO number, n4
= 4th DTO number, n5 = 5th DTO number.
Store the dial to open numbers (DTO) to the next available memory location(s),
where n1 = 1st DTO number, n2 = 2nd DTO number, n3 = 3rd DTO number, n4
= 4th DTO number, n5 = 5th DTO number, also send conrmation text of DTO
numbers and locations of where they are stored.
- 31 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
1111STR”01912243174”,”01912241558”,”07771234567”
Remember an optional ? can be included at the end of the message to receive conrmation of the stored numbers, like so:
The following reply will be received from the GSM LITE:
MEM OPEN 003 = 01912243174
MEM OPEN 004 = 01912241558
MEM OPEN 005 = 07771234567
MEM OPEN 006 = 01912241559
MEM OPEN 007 = 07897123456
OK VIDEX GSM
Remember to include “ and , where appropriate. In the example above if locations 001 and 002 already had numbers programmed
then the dial to open numbers (DTO) n1, n2, n3, n4 and n5 would be stored in the GSM LITE starting from location 003 up to 007.
IMPORTANT NOTE: It should be noted that when programming multiple dial to open numbers (DTO) using this command the
GSM LITE starts checking for free memory locations from 001 to see if there is enough available space to store them. So if the
number of DTO numbers being programmed is greater than the number of available locations the GSM LITE will skip to nd the
next available location that has enough space to store the numbers.
For example: the DTO locations from 001 to 003 and locations
from 006 to 008 may be occupied with DTO numbers, location
004, location 005 are available and locations from 009 onwards
are available (refer to table on the right). If the intention is to
store three DTO numbers: 01912243174 (n1), 01912241558 (n2),
07771234567 (n3). The following text message would be sent to
the GSM LITE:
In the example above although the DTO locations 004 and 005 are available the programming command sent to the GSM LITE is to
store three DTO numbers. As the quantity of DTO numbers to be stored is greater than the number of memory locations available
from location 004 the GSM LITE will look for the next set of free locations that is able to accommodate the three DTO numbers. So
in this example the GSM LITE will bypass locations 004 and 005 as there isn’t sucient space to store the three DTO numbers, it will
also bypass locations 006, 007 and 008 as these locations are already occupied. However the locations from 009 onwards are free
to use so the GSM LITE will store the rst DTO number (n1) in location 009 and then the next DTO number (n2) in location 010 and
so on.
IMPORTANT NOTE: It is also possible that when storing multiple DTO numbers using the STR code a start location, nnn, can be
included in the programming command i.e. 1111STRnnn”n1”,”n2”,”n3”,”n4”,”n5”. However when a start location is included in the
command, while the GSM LITE will store the DTO numbers from this location, any memory location after it that already has a DTO
number stored will be overwritten with the new DTO number.
Using the same details from the previous example: The DTO locations from 001 to 003 and 006 to 008 are already occupied with DTO
numbers, location 004 and 005 are available. Locations from 009 onwards are also available (refer to previous table). If the intention
is to store the following three DTO numbers: 01912243174 (n1), 01912241558 (n2), 07771234567 (n3) starting from location 004. The
following text message would be sent to the GSM LITE:
MEM OPEN 004 = 01912243174
MEM OPEN 005 = 01912241558
MEM OPEN 006 = 07771234567
OK VIDEX GSM
In this example the 1st and 2nd DTO numbers 01912243174 (n1) and 01912241558 (n2) would be stored in the available locations
004 and 005 as expected, however the 3rd DTO number 07771234567 (n3) would overwrite the number that was already stored in
location 006.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 32 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
DELETE A DIAL TO OPEN NUMBER WITHOUT KNOWING IT’S LOCATION DET
Although a dial to open number (DTO) can be deleted from the GSM LITE using the programming command 1111STRnnn””? , it
is also possible to delete a dial to open number if the location is not known. The following messages can be used to delete and
conrm a dial to open number has been deleted from the GSM LITE.
1111DET”yyyyyyyyyyy”Delete the dial to open number yyyyyyyyyyy (where yyyyyyyyyyy DTO number).
1111DET”yyyyyyyyyyy”?Delete the dial to open number yyyyyyyyyyy (where yyyyyyyyyyy DTO number). Also
send a conrmation text back to the sender.
Note that when using this command the full telephone number will be required otherwise the GSM LITE will respond with:
NOT FOUND
OK VIDEX GSM
SET CALL TIME SPT
The call time is the maximum time in seconds that a call will last before the GSM LITE intercom automatically clears the call down.
The time can be set from 20 seconds up to 240 seconds (4 minutes) and begins from when the call button is rst pressed. The default
time is set to 40 seconds. The following messages can be used to set/check the maximum call time.
1111SPTnnStore the time nn x 20 seconds (e.g. nn = 03, time = 60 seconds).
1111SPTnn?Store the time nn x 20 seconds (e.g. nn = 02, time = 40 seconds, refer to table below), also
send a conrmation text back to the sender.
1111SPT?Query the current stored time. A text message will be sent back to the sender showing the
stored time (remember to multiply the number in the received text by 20 seconds).
nn multiplier:nn = 01, time = 20 secsnn = 02, time = 40 secsnn = 03, time = 60 secs
nn = 04, time = 80 secsnn = 05, time = 100 secsnn = 06, time = 120 secs
nn = 07, time = 140 secsnn = 08, time = 160 secsnn = 09, time = 180 secs
nn = 10, time = 200 secsnn = 11, time = 220 secsnn = 12, time = 240 secs
SET RELAY TIME RLT
The relay time can be from 01 – 99 seconds or latching (set the relay time to 00 for latched mode. In latch mode, the relay will stay
energised until the command is sent again).
1111RLTnnStore the relay time nn = time in seconds (e.g. nn = 05, time = 5 seconds).
1111RLTnn?Store the relay time nn = time in seconds. Also send a conrmation text back to the sender.
1111RLT?Query the current stored relay time. A text message will be sent back to the sender
showing the stored relay time.
SET AUXILIARY OUTPUT AO1 TIME A1T, FOR A1M = 01 ONLY
The auxiliary output AO1 time can be set from 01 - 99 seconds or latching (set the AO1 output time to 00 for latched mode. In latch
mode the AO1 output will stay triggered until the relevant command is sent again to unlatch the AO1 output. This option is only
available when the AO1 output mode, A1M, is set to mode 01. Please refer to the A1M commands below for more details).
1111A1TnnStore the AO1 time nn = time in seconds (e.g. nn = 05, time = 5 seconds).
1111A1Tnn?Store the AO1 time nn = time in seconds. Also send a conrmation text back to the sender.
1111A1T?Query the current stored AO1 time. A text message will be sent back to the sender showing
the stored AO1 time.
SET AUXILIARY OUTPUT AO1 MODE A1M, MODES 00 05
The auxiliary output AO1 has up to six modes that can be set:
Call Activated: nn = 00
AO1 output will activate when a call begins and deactivate when a call ends. See example, Fig.16, on page 18.
User Activated: nn = 01
To activate the AO1 output either short terminals g to 5 (auxiliary 1 input) on the GSM LITE intercom or press 6 on the telephone
during a call. See example, Fig.17, on page 18.
Used for Status Indication: nn = 02
When in this mode, the AO1 terminal is used exclusively for monitoring the status of an input. For example, checking if a gate/door
is open or closed. See example, Fig.18, on page 19.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 33 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
Divert Calls to Master Number: nn = 03
When in this mode, the AO1 terminal is used exclusively for monitoring the status of a switched input to decide if calls should be
diverted to the master number or not. See example, Fig.19, on page 19.
Call Activate (Timed): nn = 04
AO1 output will activate when a call begins and deactivate when the auxiliary 1 output time (A1T) expires. See example, Fig.20, on
page 20.
Enable/Disable “Dial to Open”: nn = 05
When in this mode, the AO1 terminal is used to enable/disable the dial to open feature via an external C/NO switched input across
terminals AO1 & g, (for example the C/NO relay contacts on a timeclock could be connected across terminals AO1 & g on the GSM
LITE intercom. When the timeclock relay is ON then no dial to open numbers are allowed. The GSM LITE answers the call and awaits
the master code to be entered. When the timeclock relay is OFF all dial to open numbers will operate as normal). See example,
Fig.21, on page 20.
1111A1MnnStore the AO1 mode nn = 00 - 05.
1111A1Mnn?Store the AO1 mode nn = 00 - 05. Also send a conrmation text back to the sender.
1111A1M?Query the current stored AO1 mode. A text message will be sent back to the sender
showing the stored A1O mode.
SET DAYS TO WAIT BEFORE MAKING A CALL NOD
In the event the GSM LITE intercom panel is not used for long periods of time it could be possible that the network disconnects it. To
prevent this from happening it is possible to program a time period (from 01 – 99 days or disabled 00) to wait before the intercom
panel makes a short call to refresh the connection to the network. This time period is reset after each call made on the system and
will only happen if the full time period elapses without any incoming or outgoing calls.
1111NODnnStore the time nn = time in days (e.g. nn = 07, time = 7 days).
1111NODnn?Store the time nn = time in days. Also send a conrmation text back to the sender.
1111NOD?Query the current stored time. A text message will be sent back to the sender showing
the stored time.
DIVERT TIME DIT
The divert time is the number of seconds to wait for a call to be answered before diverting to the second number. The default time
is 15 seconds (the count down begins from when the call button is pressed, but is refreshed when the telephone begins to ring)
and can be set from 01 – 99 seconds.
1111DITnnStore the divert time nn = time in seconds (e.g. nn = 15, time = 15 seconds).
1111DITnn?Store the divert time nn = time in seconds. Also send a conrmation text back to the
sender.
1111DIT?Query the current stored divert time. A text message will be sent back to the sender
showing the stored divert time.
CHECK SIGNAL STRENGTH SIG
At any time the signal strength of the GSM LITE can be checked (also see notes understanding the signal strength on page 44). It
is advisable that when the GSM is rst setup and before any other programming is carried out to check the signal strength of the
GSM LITE intercom. If the signal strength is too low the GSM intercom may not operate properly and therefore the GSM antenna will
need to be repositioned to increase the signal strength. Use the following command to check the signal strength.
1111SIG?Check the signal strength of the GSM LITE intercom and send a conrmation text back to
the sender.
CHECK SOFTWARE VERSION VER
It is possible to check the current version of software in the GSM LITE module. This may be necessary to see if an update is required for
any additional features or updates on the GSM LITE intercom which may be included on later versions. Use the following command
to check the software version.
1111VER?Check the software version of the GSM LITE intercom and send a conrmation text back
to the sender.
FORCED DIAL/DIAL A NUMBER DLE
A useful feature of the GSM LITE intercom is its ability to call a number sent to it in a text message. This feature can be used when
setting up the SIM card. For example, disabling the voicemail facility or disabling automatic SMS messages or missed calls. Any
4000 Series GSM Lite Audio Intercom - Technical Manual
- 34 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
number up to 15 digits can be called and the call will last for a maximum of 40 seconds. The example below would switch OFF
voicemail on a Vodafone SIM card. Substitute the Vodafone number for other service providers.
1111DLE”1210”Dial 1210 for the intercom panel.
Other useful numbers which can be used with this feature are as follows. Please also check the network service provider’s web sites
for other useful codes.
VodafoneO
DISABLE VOICEMAIL12101760
DISABLE TEXT ALERTS#148#1760
IMPORTANT NOTE: Disabling voicemail and text alerts is very important as there is no way to retrieve either of these services
from a GSM intercom panel. Disabling these features will also prevent the intercom panel switching to voicemail or sending a
text when dialling in from another phone.
STORE SMS AUXILIARY MESSAGE SMS, WHEN AUXILIARY INPUT 2 IS TRIGGERED
When terminals g & 4 (auxiliary input 2) are triggered on the GSM LITE intercom, a text message will be sent to the master telephone
number. The text message can be customised using the following command.
1111SMS”HouseAlarm”Change SMS message to HouseAlarm.
Please also note that the message can be a maximum of 32 characters long and cannot include spaces or “ as part of the message.
See an example of this feature, Fig.22, on page 21.
CHANGE THE FOUR DIGIT CODE CDE
The four digit code can be any combination of numbers between 0-9 but must be 4 digits long. The code allows access to the
programming menu in dial in mode and must be used when sending text messages to the GSM intercom panel. Use the following
message to change the code.
2
1111CDEnnnnChange the 4 digit code to nnnn (where nnnn = new 4 digit code).
TRIGGER THE RELAY RLY
There are a few ways to trigger the GSM’s relay. The rst is to press button 3 on the telephone during a call and the relay will operate
for the programmed time. Another way is to send the following text message.
1111RLYOperate the GSM relay (for the programmed time).
1111RLY?Operate the GSM relay (for the programmed time) and send a conrmation text back to
the sender.
TRIGGER AUXILIARY OUTPUT AO1 A1O
It is possible to trigger the auxiliary output AO1 for the programmed AO1 output time (please note that this method of triggering
auxiliary output AO1 is only possible when the A1M mode has been set to mode 01: user activated, also refer to A1M notes on page
33 and the example on page 18, Fig.17). This can be done by shorting terminals g & 5 on the GSM LITE intercom, pressing button 6
on the telephone during a call or by sending the following message to the GSM intercom.
1111A1OTrigger auxiliary output AO1 (for the programmed time).
1111A1O?Trigger auxiliary output AO1 (for the programmed time) and send a conrmation text
back to the sender.
STORE BALANCE CHECK DIAL STRING SDL
Several network providers oer the facility to check available balance on their pay as you go taris. For example, on Vodafone the
string is *#1345# and on O2 the string is *#10#. Other networks may also have this feature. Because the intercom will not know the
details of the network provider’s SIM card which you have inserted it will be necessary to store the correct string in order to use the
credit balance check features.
1111SDL”*#1345#”Store the balance check string for a Vodafone pay as you go.
1111SDL”*#10#”Store the balance check string for an O
2
pay as you go.
IMPORTANT NOTE: Videx are only aware of the balance check dial string codes for the network providers mentioned above.
Check dial string codes for other networks are currently unavailable at this time. Please also note that this programming
function is only applicable for pay as you go SIM cards.
CHECK CREDIT BALANCE BAL
The balance can only be checked if the correct balance check string has previously been stored using the SDL code explained
above. At any point the user will be able to send the following text message and the GSM LITE intercom will reply with the current
balance stored on the SIM card.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 35 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
1111BAL?Check current balance of the SIM in the GSM LITE intercom and send a conrmation text
back to the sender.
In addition to this feature the GSM LITE intercom also has the facility to monitor the available credit and then text the user to inform
them when the credit has fallen below £5.00, €5.00 or $5.00. It will then remind the user with another text after every 5 calls until
the credit has either increased or if it runs out. To use this feature, the following settings must rst be made:
• A Pay As You Go SIM card from a provider that oers this service (Vodafone, O2) must be used.
• The correct balance check string must be stored using the SDL code (see store balance check dial string).
• A mobile phone number that is to receive the ‘balance low’ text must be stored in the master telephone number location
using the STM code (refer to ‘store master telephone number’ feature below).
STORE THE MASTER TELEPHONE NUMBER STM
The master telephone number is the number which will receive automatic balance updates when the balance gets low (if this
feature is setup) and will receive the SMS message if auxiliary input 2 is triggered (also refer to example on page 21, Fig.22). To store
a master telephone number the following programming texts can be sent to the GSM LITE intercom.
1111STM”yyyyyyyyyyy”Store the telephone number yyyyyyyyyyy.
1111STM”yyyyyyyyyyy”?Store the telephone number yyyyyyyyyyy and send a conrmation text back to the sender.
1111STM?Query the master telephone number stored. A text message will be sent to the sender with the
stored number for that location.
1111STM””Delete the master telephone number stored.
1111STM””?Delete the master telephone number stored and send a conrmation text back to the
sender.
LATCH THE RELAY RLA
It is also possible to latch the GSM intercom relay closed. This function is particularly useful if the GSM intercom relay is connected
to a gate controller (via an Art.120 pcb, refer to Fig.13, page 15) and the user wishes to ‘hold open’ the gate. The following text
message can be sent to the GSM LITE intercom.
1111RLALatch the GSM LITE relay to the C/NO position.
1111RLA?Latch the GSM LITE relay to the C/NO position and send a conrmation text back to the
sender.
UNLATCH THE RELAY RUL
If the GSM LITE’s relay has been latched it is possible to unlatch the relay with the following text message.
1111RULUnlatch the GSM LITE relay back to the C/NC position.
1111RUL?Latch the GSM LITE relay to the C/NC position and send a conrmation text back to the
sender.
IMPORTANT NOTE: The GSM LITE’s relay can also be unlatched by pressing 3 on the telephone during a call, unless the LLA
feature has been enabled (also see LLA program notes on page 41).
LATCH AUXILIARY OUTPUT AO1 A1L
Auxiliary output AO1, like the onboard relay, can be latched. To latch auxiliary output AO1 the following text message can be sent
to the GSM LITE intercom.
1111A1LLatch auxiliary output AO1.
1111A1L?Latch auxiliary output AO1 and send a conrmation text back to the sender.
UNLATCH AUXILIARY OUTPUT AO1 A1U
Auxiliary output AO1 can also be unlatched. To unlatch auxiliary output AO1 the following text message can be sent to the GSM
LITE intercom.
1111A1UUnlatch auxiliary output AO1.
1111A1U?Unlatch auxiliary output AO1 and send a conrmation text back to the sender.
CHECK INPUT STATUS CHK
IMPORTANT NOTE: This feature is only applicable when auxiliary output AO1 mode has been set to mode 02. If auxiliary output
AO1 is set to any other mode then this feature will not work (also refer to Fig.18 on page 19 and setting auxiliary output AO1
mode, A1M, on page 33).
If the auxiliary output A1M mode has been set to mode 02 then the status of this mode can be checked by sending the following
text to the GSM LITE intercom.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 36 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
1111CHK?Check the current status of auxiliary output AO1 and send a conrmation text back to the
sender.
Example:Check the current status of auxiliary output AO1, the following text can be sent to the GSM LITE intercom:
1111CHK?
The GSM intercom will reply with either of the following texts:
IN = OP
OK VIDEX GSM
(status open)
SILENT DIALLING MODE AUE
When the GSM LITE intercom is calling the telephone number stored there is a choice of either hearing the ringing noise from the
intercom panel or just hearing beeps to indicate a call is in progress.
• Ringing heard during calling: nn = 01
• Beeps heard during calling: nn = 00
The following text messages can be sent to the GSM to enable (00), disable (01) or query the setting of the silent dialling feature.
1111AUEnnSet the silent dialling mode nn: 01 or 00.
1111AUEnn?Set the silent dialling mode nn: 01 or 00 and send a conrmation text back to the sender.
1111AUE?Query the current mode stored. A text message will be sent back to the sender conrming
which silent dialling mode has been set.
or
IN = CL
OK VIDEX GSM
(status closed)
SEND DTMF TONE AFTER CALL ANSWERED FOR CALL BUTTON 1DTP, DTD AND DTT
It is possible to set the GSM LITE intercom to send a DTMF tone after a call is answered. This option is only available for both the
primary number and the divert number for button 1. This feature is useful if the intercom is dialling into a telephone system where
an automated menu is present and a DTMF tone is required to select a particular option from the menu. This feature is disabled by
default. The following programming text messages allow the user to setup the DTMF tone(s) required.
• The DTP command sets the DTMF tone required (from 0 - 9) after a call is answered for button 1.
• The DTD command sets the DTMF tone required (from 0 - 9) after the diverted call is answered for button 1.
• The DTT command sets the delay time from when the call is answered to when the DTMF is sent.
SET DTMF TONE REQUIRED FOR BUTTON 1 PRIMARY CALL
1111DTPnSet DTMF tone required, where n = 0 - 9 for DTMF tones 0 - 9 or X to disable this feature
(for button 1).
1111DTPn?Set DTMF tone required, where n = 0 - 9 for DTMF tones 0 - 9 or X to disable this feature.
Also send a conrmation text back to the sender with the stored DTMF tone setting (for
button 1).
SET DTMF TONE REQUIRED FOR BUTTON 1 DIVERT CALL
1111DTDnSet DTMF tone required, where n = 0 - 9 for DTMF tones 0 - 9 or X to disable this feature
(for divert 1).
1111DTDn?Set DTMF tone required, where n = 0 - 9 for DTMF tones 0 - 9 or X to disable this feature.
Also send a conrmation text back to the sender with the stored DTMF tone setting (for
divert 1).
SET THE DELAY TIME FROM WHEN THE CALL IS ANSWERED TO WHEN THE DTMF TONE IS SENT
1111DTTnnSet the time nn, where nn = 01 - 12 seconds.
1111DTTnn?Set the time nn, where nn = 01 - 12 seconds and also send a conrmation text back to the
sender of the time stored.
QUERY THE SETTINGS
1111DTP?Query the DTMF tone set, replies TP = n, where n = 0 - 9 or X.
1111DTD?Query the DTMF tone set, replies TD = n, where n = 0 - 9 or X.
1111DTT?Query the delay time set, replies TT = nn, where nn = 01 - 12 seconds.
ENABLE THE DIAL ‘0’ ON ANSWER FUNCTION EDZ
When enabled this feature allows an incoming call to be diverted to the programmed divert telephone number if the ‘0’ button on
the telephone has not been pressed after answering the call. This can be useful if the user’s number has an answerphone service (or
answer machine) and they do not want the call to be answered by this service or if the primary number (mobile no.) is switched o.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 37 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
The default for this function is disabled (set to 00). The following texts can be used to enable or disable this function.
1111EDZnnSet the dial ‘0’ function nn: 01 or 00 (01 = enable, 00 = disabled).
1111EDZnn?Set the dial ‘0’ function nn: 01 or 00 (01 = enable, 00 = disabled) also send a conrmation
text back to the sender.
1111EDZ?Query the dial ‘0’ mode set.
When this feature is set the user answering the call must press ‘0’ on their phone to accept the call otherwise the call will be diverted
to the second (divert) number.
ENABLE THE # HASH FUNCTION ED#
Once enabled the end user must press the # button on their phone before pressing any other button (also refer to the user command
table on page 43) with the exception of when the user needs to enter the 4 digit programming code “1111”.
The user will have up to 3 seconds to press the user command button (e.g. button 3 to activate the relay), if the user doesn’t press
the next button within the 3 second window they will have to press the # button again.
By default this function is disabled (set to 00). The following texts can be used to enable or disable this function.
1111ED#nnSet the # function nn: 01 or 00 (01 = enable, 00 = disabled).
1111ED#nn?Set the # function nn: 01 or 00 (01 = enable, 00 = disabled) also send a conrmation text
back to the sender.
1111ED#?Query the # mode set.
FIND A TELEPHONE NUMBER FDT
The nd a telephone number feature allows the user to nd the dial to open location (between 000 - 099) of where a particular
telephone number is stored in the GSM LITE intercom. It can locate the number either from using the full telephone number or a
minimum of the last 4 digits of a number (see following examples). The following text messages can be used.
1111FDT”yyyyyyyyyyy”?Find dial to open location of telephone number yyyyyyyyyyy stored, where yyyyyyyyyyy
= telephone number (minimum of 4 digits).
Example 1: Find dial to open location of the telephone number using the full number 01234567890, the following text can be
sent to the GSM LITE intercom:
1111FDT”01234567890”?
The GSM intercom will reply with the following text:
STORED IN nnn
OK VIDEX GSM
where nnn = the dial to open location of where the number is stored.
Example 2: Find dial to open location of the telephone number using the last 4 digits of the number 4567, the following text
can be sent to the GSM LITE intercom:
1111FDT”4567”?
The GSM intercom will reply with the following text:
STORED IN nnn
OK VIDEX GSM
where nnn = the dial to open location of where the number is stored.
END ON LAST DIVERT EOD
The end on last divert feature allows the GSM intercom to ring the programmed divert number as usual and if the divert number is
not answered within the divert time it will then end the call. It will also end the call if there is no divert number stored in the GSM
intercom.
By default this feature is disabled (set to 00), but can be enabled (set to 01). The following programming commands can be used to
set/check the end on divert function.
1111EODnnSet end on last divert to nn, where nn = 00 (disabled) or 01 (enabled).
1111EODnn?Set end on last divert to nn, where nn = 00 (disabled) or 01 (enabled). Also send a
conrmation text back to the sender.
1111EOD?Query the end on last divert status stored in the GSM module.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 38 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
SHUTDOWN AND RESTART RBT
This command feature allows the GSM LITE intercom to be remotely shutdown and then rebooted again. The following command
can be sent to the GSM module.
1111RBTShutdown and restart the GSM module.
IMPORTANT NOTE: This feature should not be confused with the ‘hard-wired’ reset (described on page 26). The RBT function
simply powers down the GSM module and then powers it back up again.
SIMULATE A BUTTON PRESS VIA SMS MESSAGE FOR BUTTONS 0104 BUT
It is possible to simulate a button press (for the call button range 01 - 04) on the intercom by sending the following programming
command, shown below, to the GSM LITE intercom. This feature can be useful if there is suspected fault with a call button or if there
is an issue with the wiring for the buttons into the GSM’s button matrix.
1111BUTnnSimulate a button press for button number nn, where nn = button number 01 - 04.
The following commands are reserved for the technical department for interrorgating the GSM LITE module when testing and
applying specic additional features that are not covered in this technical manual. For the application of these commands please
contact Videx Technical on tel: 0191 224 3174 for UK based customers and Videx customer support on tel: +39 0734 631699 for
overseas customers.
PROGRAM BY ‘AT’ COMMANDS PRG
This is an advanced feature of the system which can allow an ‘AT’ format command to be sent to the OEM GSM module.
1111PRG(command)Send an ‘AT’ command to the OEM module.
AT COMMAND SEND AT START UP AT1, AT2 AND AT3
The AT commands AT 1 , AT 2 and AT3 are advanced commands of the GSM LITE that allows additional features to be incorprated into
the module for testing purposes and include additional features for a specic application that is not already covered in this manual.
The following commands can be sent to the GSM module.
1111AT1”ATxxxxxx”?Include any AT command for AT1.
1111AT2”ATxxxxxx”?Include any AT command for AT2.
1111AT3”ATxxxxxx”?Include any AT command for AT3.
OBTAIN THE GSM’S IMEI NUMBER IME
If the IMEI number (unique 15 digit number of the main internal hardware chip) of the GSM LITE intercom is required the following
text message can be sent to obtain the number.
1111IME?Query IMEI number of the GSM module, also send conrmation to the sender.
Example:Obtain IMEI number of the GSM module, the following message can be sent to the GSM intercom:
1111IME?
The GSM LITE intercom will reply with the following text:
IMEI-357803045065535
OK VIDEX GSM
IMPORTANT NOTE: If installing the GSM LITE for the rst
IMEI number
time, when registering the SIM card with the chosen network
provider they may ask for the IMEI number of the GSM module.
As the programming command described above will only work
GL865-DUAL V3
IMEI: 357803045065535
UL865-EUR
IMEI: 355856050228416
with a SIM card that has already been registered with a network
the command will not work.
Instead to obtain the GSM’s IMEI number, which is located on
the main hardware chip internally, the GSM module will have
to be opened. The IMEI number is printed on the Telit chip label
just below the model number, as shown in Fig.61.
Fig. 61
It is recommended that you contact Videx Technical on tel: 0191 224 3174 for UK based customers and Videx Customer Support:
+39 0734 631669 for overseas customers for advise on how to do this.
Alternatively use a SIM that is already registered with another network provider and t it into the GSM LITE intercom (following
the procedure on page 25 for initialisation), then use the programming command above 1111IME? to obtain the GSM LITE’s
IMEI number so that when registering the actual SIM that will be used with the GSM LITE with the chosen network you will have
the appropriate IMEI number to hand.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 39 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Programming the GSM Intercom
UNLATCH PREVENTION FEATURE LLA
The unlatch prevention command LLA, when enabled, will prevent a programmed latched output (the GSM’s relay or the auxiliary
output) from being inadvertently unlatched by a DTO number or by pressing the relevant button (3) on the phone during a call.
Even when this feature is enabled if either the GSM’s relay or the auxiliary output have been setup to latch they can still be unlatched
using the relevant 1111RUL or 1111A1U programming command.
By default this feature is disabled (set to 00), but can be enabled (set to 01). The following programming commands can be used to
enable/disable and check the unlatch prevention feature.
1111LLAnnSet the unlatch prevention feature to nn, where nn = 00 (disabled) or 01 (enabled).
1111LLAnn?Set the unlatch prevention feature to nn, where nn = 00 (disabled) or 01 (enabled). Also
send a conrmation text back to the sender.
1111LLA?Query the status of the unlatch prevention feature stored in the GSM module.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 40 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
The GSM Mobile App
THE VIDEX SMS WIZARD
In addition to programming by direct text messages it is also possible to program the GSM LITE intercom
using the GSM mobile app, the Videx SMS Wizard.
The SMS wizard can be used to simplify the programming of the GSM intercom using SMS messages.
The SMS wizard generates the text message required to communicate with the GSM intercom. Depending on the model of the
GSM (digital GSM, GSM PRO, GSM Lite, GSMVRK and 2270 GSM module) text messages can be generated to program features such
as access codes, proximity access fobs/cards, dial to open (DTO) telephone numbers, assign pre-existing access levels, free access
periods and call button/apartment telephone numbers.
Other features are also included to simplify the programming setup process. Additionally it is also possible for users to control their
gate or door via the dial to open (DTO) or text message features.
WHERE TO DOWNLOAD THE SMS WIZARD AND GETTING STARTED
The SMS wizard is available for both Android smart devices (mobile smartphones and tablets) and also Apple iOS (iPhones and
iPads) and can be downloaded for free from the Google Play Store (for Android devices) and the App Store (for iOS devices).
Before using the SMS wizard the following details will be required for initial setup:
• Model of the GSM intercom module - e.g. Art.4811 (GSM LITE), Art.4812 or Art.4812R (digital GSM) etc.
• Firmware level of the GSM intercom - e.g. for the Art.4811 GSM LITE the rmware might be LT3.0.4 (the rmware
version of the GSM module can usually be found on the label on the back of the GSM intercom or by sending the text
message 1111VER? to obtain the rmware version, also refer to notes on page 34).
• Telephone number of the GSM intercom - i.e. the mobile number of the SIM card being used in the GSM module.
• Master code of the GSM intercom - i.e. the 4 digit code used for programming, by default this is set to '1111'. In the
event that this code has been forgotten or lost please refer to 'change the 4 digit master code (CDE)' notes on page 35
or 'resetting the master code to 1111' notes on page 26 to reset the code back to factory default if required.
Once downloaded and installed it is recommended that you rst tap on the help icon
homescreen and then follow the 'TO GET STARTED' quick guide.
It should also be noted when navigating between the app's menu to the required programming screens the help icon
located in the top right corner of each screen, can be used to oer additional guidance on how to use the current programming
screen.
SMS WIZARD APP COMPATIBILITY
The SMS wizard is compatible with the latest GSM intercoms and modules available. It is also compatible with the older Art.4810N
model from rmware version 1.0.4 onwards.
?
in the top right corner of the app's
?
, always
4000 Series GSM Lite Audio Intercom - Technical Manual
- 41 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
System Operation
MAKING A CALL AND CANCELLING A CALL FROM THE GSM LITE INTERCOM TO THE PHONE
Press the required call button. Two beeps will be heard from the GSM LITE intercom to indicate the call has been placed.
If a mistake is made, simply press any other button to cancel the call, a long beep will be heard to conrm the call has been cancelled.
IMPORTANT NOTE: If the silent dialling mode AUE has been left on default (i.e. silent dialling mode disabled) a normal telephone
dial tone will be heard through the GSM’s speaker after the call button has been pressed to indicate that the number is being
called. If the same button is pressed again after ve seconds of placing the initial call this will also cancel the call. Pressing the
same button before the ve seconds is up will do nothing.
ANSWERING AND ENDING A CALL FROM THE GSM LITE INTERCOM
After answering the call the speech will be open and a conversation can take place. While the speech is open the user can:
• release the door/gate (see notes below).
• latch the door/gate (see notes below).
• activate the auxiliary output AO1 (depending on auxiliary mode setup, also see programming notes).
• adjust speech volumes to and from the GSM LITE.
Also refer to the user command tables on page 43.
To end the call simply hang up the phone.
DIVERTED CALL
First make a call from the GSM intercom, as described above. If a divert number is programmed and the primary number is not
answered the GSM will then dial the divert number after the programmed divert time DIT has elapsed (also refer to STD divert
number programming and DIT divert time setup in the programming section of this manual).
IMPORTANT NOTE: When the GSM LITE intercom diverts to a programmed divert number there will be a brief pause before
the intercom then proceeds to dial the divert number. Also if the silent dialling mode AUE has been left on default (i.e. silent
dialling mode disabled) a normal telephone dial tone will be heard from the GSM’s speaker after the brief pause to indicate that
the divert number is being called.
RELEASING THE DOOR/GATE FROM THE PHONE AFTER A CALL FROM THE GSM LITE INTERCOM INC. LATCH/UNLATCH
Releasing the door/gate is signalled by 1 second interval beeps from the GSM LITE intercom panel.
After the call is answered pressing 3 on the phone releases the door/gate for the programmed relay time.
Pressing 1 followed by 0 will latch the door/gate in the open position (to unlatch press 3 and the door/gate will unlatch or send text
message 1111RUL to the GSM LITE intercom).
Also refer to the user command tables on page 43.
RELEASING THE DOOR/GATE BY DIALLING THE GSM LITE INTERCOM DIAL TO OPEN
Releasing the door/gate by dialling into the GSM LITE using the dial to open DTO number is only possible if the caller’s number has
been stored correctly using the STR programming command (also refer to STR programming notes for correct setup).
Simply dial the mobile number of the SIM in the GSM LITE intercom. The GSM intercom will recognise the stored dial to open
number that’s calling. The GSM will drop the call and open the door/gate for the programmed relay RLT time.
IMPORTANT NOTE: For this function to operate correctly the stored DTO number must have any “caller ID” or “witheld number”
feature switched OFF. If this is not switched OFF on the number making the call to the GSM LITE intercom then the GSM module
will not recognise the caller’s number and simply drop the call and the door/gate will not operate.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 42 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
User Commands
USER COMMAND TABLES
The following user command table shows the user commands that can be carried out during a call. Successful commands are
signalled by two beeps from the telephone, errors are signalled by four beeps.
IMPORTANT NOTE: When the ED# function has been enabled the user must press the # button on their phone before pressing
any of the following user commands (also refer to ED# notes on page 38 for further information).
FUNCTION1st KEY TO PRESS2nd KEY TO PRESS
Latch the relay (unlatch by pressing 3)10
Release the door or gate3n/a
Activate auxiliary output AO1
Adjust door speech volume (GSM speaker)40 - 9 (0 = lowest, 9 = highest)
Adjust phone speech volume (GSM mic)70 - 9 (0 = lowest, 9 = highest)
Status Indication for AO1
Activating auxiliary output AO1 in this way is only possible when A1M mode has been set to mode 01 (also see notes on page
33, set auxiliary output AO1 mode, and Fig.17, on page 18) and will operate for the programmed AO1 time. If the AO1 output
time has been set to latch simply press 6 on the phone to unlatch the output again.
Auxiliary input AO1 status indication is only possible when A1M mode has been set to mode 02 (also see notes on page 33, set
auxiliary output AO1 mode, and Fig.18, on page 19).
1
(when A1M = mode 01)6n/a
2
(when A1M = mode 02)9n/a
The next user command table shows the SMS text messages that can be sent to the GSM LITE intercom while in standby (the
examples shown in the table use the default 4 digit master code 1111).
FUNCTIONMESSAGE TO SEND
Check the signal strength1111SIG?
Check the available balance
3
1111BAL?
Check the software version1111VER?
Release the door/gate1111RLY? (? optional, send if conrmation is required)
Latch the relay1111RLA? (? optional, send if conrmation is required)
Unlatch the relay1111RUL? (? optional, send if conrmation is required)
Activate auxiliary output AO11111A1O? (? optional, send if conrmation is required)
Latch auxiliary output AO11111A1L? (? optional, send if conrmation is required)
Unlatch auxiliary output AO11111A1U? (? optional, send if conrmation is required)
Check Input Status1111CHK? (also see notes on pages 36 - 37)
Find a Dial to Open (DTO) number (000 -
999)
1111FDT”yyyyyyyyyyy”? (where yyyyyyyyyyy = telephone number, minimum of 4
digits, also see notes on page 38)
The balance can only be checked if the correct balance check string has been stored (also see SDL notes on page 35). This feature
is only applicable for pay-as-you-go SIM cards.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 43 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Additional User Information
UNDERSTANDING THE SIGNAL STRENGTH SIG AND BIT ERROR RATE BER
When a request for signal strength message is sent to the GSM LITE intercom it will reply with a two part code.
The rst part of the code is a signal strength code SIG which will be between 0 – 31 or 99. Ideally the signal strength should be as
close to 31 as possible for the best possible performance. The lower the number, the weaker the signal. Signal strengths lower than
10 may cause operational problems such as loss of speech quality (and possibly missing DTMF tones) and/or network loss. A signal
strength of 99 indicates it could not be detected.
The second part of the code is the bit error rate BER. The bit error rate is used in digital telecommunication as a gure of merit for
how eectively the receiver (in this case the GSM LITE intercom) is able to decode transmitted data (the data in this instance are the
various text message commands used to program the GSM LITE intercom, described on pages 29 - 40, speech and DTMF signals
used by the GSM LITE intercom for normal operation). It is the percentage of bits that have errors relative to the total number of bits
received in a transmission. Ideally the BER code should be as close to 0 as possible, the lower the BER the better. High BER codes can
be caused by noise, interference, distortion or bit synchronisation errors over the transmission of data to the GSM LITE intercom and
as a result the problems described above (loss of speech quality, possibly missing DTMF tones and/or network loss etc.) can occur.
The example below shows the ideal reply to expect when the signal strength query 1111SIG? is sent to the GSM LITE intercom:
SIGNAL = 31
BER = 0
OK VIDEX GSM
To achieve the best overall performance from the GSM LITE intercom a high signal strength SIG and low bit error rate BER is required.
In the event that a low signal strength and high bit error rate is recieved it is recommended that the Art.432 antenna is repositioned,
where permissible, at the highest point to achieve the best signal. Where this is not possible an alternative high gain antenna can be
used, in particular Videx recommends using the ANT-GSM-2dB-5M or ANT-GSM-2dB-15M high gain antennas or another suitable
GSM antenna with a standard SMA male connector.
DIALLING INTO THE GSM INTERCOM FROM ANOTHER TELEPHONE
There are three possible outcomes to dialling into the GSM LITE intercom depending on the telephone number you are dialling
in from and the features setup during programming. The three possible outcomes are shown in the table below and are shown
in order of priority. For example, if the number is programmed to automatically activate the relay, this will take priority over the
following two options and if the telephone number is stored as a telephone number called from one of the push buttons, this will
take priority over the last option.
FUNCTIONREQUIREMENTPRIORITY
Dial in to open the Door.
After dialling the GSM number, the relay will activate
and the call will be dropped.
Dial in to activate a call (live speech, activate relay/
auxiliary AO1).
After dialling the GSM number, the call will be
answered and two beeps will be heard. The speech
will then be live.
Dial in to open the speech from a telephone number
not stored in the GSM intercom.
After dialling the GSM number, the call will be
answered and two beeps will be heard. You will then
be required to enter the 4 digit code to open the
speech.
UNDERSTANDING THE BEEPS
Functions and errors are indicated by beeps from the GSM LITE intercom panel. The following table will help you understand the
dierent beeps heard and what, if anything, needs to be done in response to the beeps.
BEEPREASONSOLUTION
Short beeps at 1 second
intervals.
Single short beep while
the system is in standby
and not being used.
Relay or auxiliary output activated.None, this is normal.
A valid text message has been received and
processed.
The telephone number of the telephone dialling in
must be stored in memory location (dial to open
list) STR000 - STR099.
The telephone number of the telephone dialling in
must be stored in memory location:
STN001 - STN004
STD001 - STD004
If neither of the two requirements above are met.
None, this is normal.
1st
2nd
3rd
4000 Series GSM Lite Audio Intercom - Technical Manual
- 44 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Additional User Information
Double beep, a single
short beep followed by a
long beep.
Long beep followed by
short beep while the
system is in standby.
Double beep.Button pressed, GSM LITE dialling stored
Long beep while the
system is in use.
Four long beeps.Not registered with a network provider but still
Six long beeps.Unknown registering problem.Try moving the antenna to a better location.
Single short beep every
10 seconds after power
up.
Short beep, long beep
repeated 3 times.
Button pressed but no number stored.Program a telephone number for the button
pressed.
Invalid text message received.If this has happened when sending one of the
programming text messages then check the
message for errors. These beeps will also be heard
if the 4 digit code in the text message is incorrect.
If you are unsure of the 4 digit code, try resetting
it to 1111.
None, this is normal.
number.
Manually ending/cancelling a call by pressing
another call button.
trying.
Unable to see the SIM card.Check the SIM card is tted correctly. Try removing
Call button pressed and either the call is on divert
to the master number or there is no master number
stored.
None, this conrms the call has been cancelled.
Another call can be placed if required.
Leave it a short while to see if it manages to nd
the network. If the beeps repeat every 30 seconds
then try moving the antenna to a better location
or changing the SIM to another network provider.
Try changing the SIM card to another network
provider.
the SIM card, cleaning and tting again. Try a
dierent SIM card.
This may be the required setup but if it’s not then
either check and store a master number to divert
the calls to or open the switch between AO1 & g
used to switch the calls into divert mode.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 45 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
User Management
RECORD SHEET
In order to manage the GSM LITE intercom more eectively it is recommended that an up to date record sheet is kept for all the
programming and system settings stored in the GSM intercom. This will also be useful if any future changes need to be made. The
following table format can be used to record the GSM’s basic information.
GSM LITE intercom telephone No.
IMEI number
Master code (default 1111)
Master telephone No.
The table format below can be used to record the call button numbers and the divert numbers (from 001 to 004).
It is also recommended that a record sheet of the dial to open DTO (STR) numbers and username is kept (from 000 to 099), following
the table format below:
MEM. LOCATIONTELEPHONE NO.USERNAME
STR000....STR099
4000 Series GSM Lite Audio Intercom - Technical Manual
- 46 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Troubleshooting
SYSTEM CHECKS AND TESTING
The following table can be used to help diagnose any potential issues that may be occur during installation and the system checks
that can be carried out to help resolve them.
SYMPTOMTEST / SOLUTION
Interference on the speech.Check the signal strength 1111SIG? (if the signal strength is too low the GSM module increases
it’s power to compensate, causing interference with the speech circuits). Try relocating the
antenna or using a more powerful or directional antenna (e.g. high gain antenna).
Ensure the antenna cables are not running close to the power supply cables or the microphone
wires inside the intercom panel.
Try a dierent SIM card from a dierent service provider as they may have better coverage in
that area.
The intercom panel repeatedly beeps
twice and the back lit name plate of
the module (not additional button
modules) does not illuminate.
Double beep, a single short beep
followed by a long beep.
The intercom panel does not respond
to SMS messages.
The GSM PRO intercom does not
respond to SMS messages, but all
other functions appear to operate ok,
e.g. DTO feature, adjusting speech
volumes, releasing the door/gate
when button 3 pressed on the phone
etc.
The call keeps dropping out.Increase the call time (SPT) in programming (refer to page 33).
Speech echoes and feeds back.Try lowering the speaker volume using the dip-switches on the back of the GSM LITE
ERROR message returned in SMS
when programming or no SMS
returned at all even though a ? was
included at the end of the message
sent.
Check the power supply has adequate voltage as described earlier in this manual (refer to
pages 7 and 23).
Try a full reset (refer to page 26), powering up with terminals g & 8 shorted.
Try a dierent SIM card.
The GSM LITE intercom module may have a fault.
No telephone number programmed for that button. Check the programming.
Check the SIM card is tted correctly (refer to page 25).
Check the SIM card has an SMS service centre number stored. This will require putting the
SIM card into a mobile phone to check. Contact the SIM card provider if you are not sure.
Check the number you are sending the message to is correct (the number of the SIM card in
the GSM LITE intercom panel).
After sending an SMS message to the GSM LITE intercom listen for a single short beep from
the intercom panel. This will indicate that the message was received and understood. If a long
beep followed by a short beep is heard it indicates the message was either not understood or
the 4 digit master code was incorrect.
Try resetting the 4 digit master code to 1111 (refer to page 26), powering up with terminals
g & 7 shorted.
This issue can occur on smartphones where the SMS messaging input method is set to
UNICODE. Smartphones generally have 3 input methods: GSM alphabet, Automatic and
UNICODE. The UNICODE setting is typically used when emoticons/emojis are used in the
message so the GSM will not recognise text messages that are set to this mode.
Check that the SMS messaging input method setting on the smartphone is not set up as
UNICODE and is set to either GSM alphabet or Automatic. This can ususally be done via the
settings icon on the smartphone. If you are unsure of how to do this Videx recommend
consulting with the user’s manual that came with the smartphone or consulting directly
with the manufacturer of the smartphone.
Check the signal strength and if necessary, move or change the antenna or try a dierent
SIM card provider.
intercom (refer to page 10).
Try adjusting the volume using the programmable settings during a call (refer to user
commands on page 43).
Check the microphone is tted correctly in the intercom panel and that the mic hole is not
blocked in any way.
Check over the message sent again and compare it with the examples in this manual.
Common errors include:
1. Using two apostrophe marks side by side instead of “. Note that these look the
same in the message. An easy way to see if this is the problem is to move the cursor
along in the message and if the cursor can get between the two “ then it is not the
correct character used.
2. Lower case letters instead of upper case. For example using stn when STN should be used.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 47 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Troubleshooting
Unable to open the gate/door from
the telephone during a call (DTMF
tones not being recognised)
If the DTMF tone to release the gate/door (or other DTMF tones shown in the rst user
command table on page 43) does not work then check to see if the ED# funtion has been
enabled:
1. Send the following SMS command 1111ED#? to the GSM and wait for a reply
conrming the status of this function.
2. Note: If the 1111EDZ function is set to 01 (enabled) then when answering the call it
will be necessary to rst press 0 to accept the call before 3 can be used to operate the
gate/door.
Further notes on how to eectively use these functions and on the setup of these functions
can be found on pages 37 and 38.
If the DTMF tones are not working reliably then try the following adjustments:
1. Send the following SMS command 1111AT1”AT#DTMFCFG=8,2500,1500”? to the
GSM intercom and wait for a reply.
2. After receiving the reply send the SMS command 1111RBT then wait for the GSM
intercom to reboot.
3. After the GSM intercom has rebooted test the door opening feature from the
telephone during a call.
If the rst option doesn’t resolve the issue then try the following:
1. Send the following SMS command 1111AT1”AT#DTMFCFG=7,2300,1300”? to the
GSM intercom and wait for a reply.
2. After receiving the reply send the SMS command 1111RBT then wait for the GSM
intercom to reboot.
3. After the GSM intercom has rebooted test the door opening feature from the
telephone during a call.
If neither of the above solutions resolve the problem then please contact Videx technical on
tel: 0191 224 3174 for further assistance. For overseas customers contact Videx customer
support on tel: (+39) 0734 631 699 for further assistance.
Further guidance can also be found in the additional user information section of this manual on pages 44 - 45 in the ‘understanding
the beeps’ table.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 48 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
General Information
FIRMWARE REVISION
DATEFIRMWARE VERSIONREVISION
10/05/16LT3.0.0Launch of 4811 GSM LITE.
01/07/16LT3.0.1/2G , LT3.1.1/3GChange to registry beeps. No beeps at automatic restart.
09/11/16LT3.0.2/2G , LT3.1.2/3GFirmware update to include: Added AT commands, up to 3
commands can be programmed using 1111ATn”command”?, where
n = 1 - 3. Bug with D0 xed. Change Telit modules CPCUMODE to
higher speed to overcome DTMF issues in Belgium. Fixed bug with
busy, engaged and No answer, where call’s didn’t end straight away
upon these events.
17/07/17LT3.0.3/2G , LT3.1.3/3GFirmware update to include: ED# function. PTE to work while unit is
still initialising. Moved balance check from ATH routine and placed
in call end routine. Add ATH send for every 8.5 minutes. Change
DTMF settings to improve DTMF decoding.
24/05/19LT3.0.4/2G , LT3.1.4/3GNew major rmware update to include:
• Added SMS commands ready for new app.
• Added SMS force dial button command 1111BUT.
• New commands –
STN for programming both numbers in single SMS.
STR for programming up to 5 dial to opens in a single SMS.
DET for deleting a DTO number without knowing it’s
location.
27/09/19LT3.0.5/2G , LT3.1.5/3GFirmware update to x double = = on SDL SMS reply. Fixed BAL
issue where message wasn’t returned when querying via SMS.
Firmware update to include SMS LLA command to prevent a latched
output being unlatched by a DTO number or pressing lock elease
during a call. SMS unlatch can still be used.
FURTHER READING
Additional information regarding connection to mains supply voltage can be found in the following regulations (for the UK only):
• I.E.E. Wiring Regulations BS7671
For overseas customers it is recommended that you consult with the relevant governing body for the appropriate regulations and
standards of your country.
4000 Series GSM Lite Audio Intercom - Technical Manual
- 49 -
66250756-EN - V2.1 - 05/11/19
4000 Series GSM Lite Audio Intercom
Notes
4000 Series GSM Lite Audio Intercom - Technical Manual
- 50 -
66250756-EN - V2.1 - 05/11/19
DISPOSAL
In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on
waste electrical and electronic equipment (WEEE)”.
The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end
of its lifetime, it must be collected separately from mixed municipal waste. The user must, therefore, dispose of the
equipment at the end of its lifetime in the suitable waste collection centres or bring it to the retailer during the purchase of a new equipment of equivalent type at the ratio of one-to-one. Furthermore, the user is allowed to dispose
of the WEEEs of very small size (domestic appliances without any external dimension exceeding 25 cm (9.84 inches)
for free to the retailers, without any purchase obligation. The correct waste disposal of the WEEEs contributes to their
reuse, recycling and recovery and avoids potential negative eects on the environment and human health due to the
possible presence of dangerous substances within them.
SMALTIMENTO
Ai sensi del Decreto Legislativo 14 marzo 2014, n° 49 “Attuazione della direttiva 2012/19/UE sui riuti di apparecchiature elettriche ed elettroniche (RAEE)”.
Il simbolo del cassonetto barrato riportato sull’apparecchiatura o sulla sua confezione indica che il prodotto alla ne
della propria vita utile deve essere raccolto separatamente dagli altri riuti urbani misti. L’utente dovrà, pertanto, conferire l’apparecchiatura giunta a ne vita presso gli idonei centri di raccolta dierenziata oppure riconsegnarla al rivenditore al momento dell’acquisto di una nuova apparecchiatura di tipo equivalente, in ragione di uno a uno. L’utente ha,
inoltre, la possibilità di conferire gratuitamente presso i distributori, senza alcun obbligo di acquisto, per i RAEE di piccolissime dimensioni (per le apparecchiature di tipo domestico con nessuna dimensione esterna superiore a 25 cm).
L’adeguata raccolta dierenziata dei RAEE contribuisce al loro riutilizzo, riciclaggio e recupero ed evita potenziali effetti negativi sull’ambiente e sulla salute umana dovuti alla eventuale presenza di sostanze pericolose al loro interno.
ÉLIMINATION
Conformément au décret législatif n ° 49 du 14 mars 2014 relatif à l’«Application de la directive 2012/19 / UE relative
aux déchets d’équipements électriques et électroniques (DEEE)».
Le symbole de la poubelle barrée sur l’équipement ou sur son emballage indique que le produit en n de vie utile doit être
collecté séparément des autres déchets municipaux en mélange. L’utilisateur doit donc remettre l’équipement en n de
vie aux centres de collecte appropriés ou le restituer au revendeur lors de l’achat d’un nouveau type d’équipement équivalent, dans le rapport de un à un. De plus, l’utilisateur a la possibilité de conférer gratuitement aux distributeurs, sans aucune
obligation d’achat, de très petits DEEE (pour les appareils ménagers sans dimensions extérieures supérieures à 25 cm).
La collecte séparée adéquate des DEEE contribue à leur réutilisation, leur recyclage et leur valorisation et évite les
éventuels eets négatifs sur l’environnement et la santé humaine en raison de la présence possible de substances
dangereuses dans ceux-ci.
ELIMINACIÓN
De conformidad con el Decreto legislativo n. 49 de 14 de marzo 2014 “Aplicación de la Directiva 2012/19/UE relativa a
residuos de aparatos eléctricos y electrónicos (RAEE)”.
El símbolo del contenedor tachado indicado sobre los aparatos o sobre los embalajes señala que el producto al nal de su vida útil debe ser recogido separadamente de otros residuos municipales mezclados. Por tanto, el usuario
deberà conferir los aparatos al nal de su vida útil en los apropriados centros de recogida selectiva o devolverlos al
revendedor al momento de la compra de nuevos aparatos equivalentes, en una relación de uno a uno. Además, el
usuario tiene la posibilidad de entregar sin cargo a los distribuidores, sin ninguna obligación de compra, los RAEEs
muy pequeños (para electrodomésticos sin dimensiones externas superiores a 25 cm).
La recogida selectiva apropriada de los RAEEs contribuye a su reutilización, reciclaje y valorización y evita potenciales
impactos negativos sobre el medio ambiente y la salud humana debidos a la possible presencia de substancias peligrosas dentro de ellos.
VERWIJDERING
In overeenstemming met het Wetsbesluit nr. 49 van 14 maart 2015 “Implementatie van de Richtlijn 2012/19/EU inzake
afgedankte elektrische en elektronische apparaten (AEEA)”.
Het doorgekruiste vuilnisbaksymbool op het apparaat of de verpakking geeft aan dat het product aan het einde van
zijn levensduur niet samen met het gewone huisvuil weggegooid mag worden. De gebruiker moet het apparaat aan
het einde van zijn levensduur inleveren bij een gepast inzamelpunt of de winkel waar hij een nieuw apparaat van een
gelijksoortig type zal kopen. De gebruiker kan tevens AEEA’s van een zeer klein formaat (huishoudapparaten met een
buitenafmeting kleiner dan 25 cm (9,84 inch)) gratis en zonder enige aankoopverplichting bij handelaars inleveren.
Een juiste verwijdering van AEEA’s draagt bij tot hergebruik, recycling en terugwinning, en voorkomt potentiële negatieve eecten op het milieu en de menselijke gezondheid door de mogelijke aanwezigheid van gevaarlijke stoen.
The product is CE marked demonstrating its conformity and is for distribution
within all member states of the EU with no restrictions. This product follows
the provisions of the European Directives 2014/30/EU (EMC); 2014/35/EU
(LVD); 2011/65/EU (RoHS): CE marking 93/68/EEC.
Le produit est marqué CE à preuve de sa conformité et peut être distribué
librement à l’intérieur des pays membres de l’union européenne EU.
Ce produit est conforme aux directives européennes 2014/30/EU (EMC) ;
2014/35/EU (LVD) ; 2011/65/EU (RoHS): marquage CE 93/68/EEC.
Het product heeft de CE-markering om de conformiteit ervan aan te tonen en
is bestemd voor distributie binnen de lidstaten van de EU zonder beperkingen. Dit product volgt de bepalingen van de Europese Richtlijnen 2014/30/EU
(EMC); 2014/35/EU (LVD); 2011/65/EU (RoHS): CE-markering 93/68/EEG.
Dutch oce:
NESTOR COMPANY BV
Business Center Twente (BCT)
Grotestraat, 64
NL-7622 GM Borne
www.videxintercom.nl
info@videxintercom.nl
Il prodotto è marchiato CE a dimostrazione della sua conformità e può essere
distribuito liberamente all’interno dei paesi membri dell’Unione Europea UE.
Questo prodotto è conforme alle direttive Europee: 2014/30/UE (EMC);
2014/35/UE (LVD); 2011/65/UE (RoHS): marcatura CE 93/68/EEC.
El producto lleva la marca CE que demuestra su conformidad y puede ser
distribuido en todos los estados miembros de la unión europea UE.
Este producto cumple con las Directivas Europeas 2014/30/EU (EMC);
2014/35/EU (LVD); 2011/65/EU (RoHS): marca CE 93/68/EEC.
ΕΎϔλϭϣϟϊϣϪϘϓϭΗέΎϬυϹCEϲ
ΩϭϳϗΔϳϥϭΩΑϲΑϭέϭϷΩΎΣ
EU/2014/30Δϳ
:(RoHS˰˰(EMC); 2014/35/EU (LVD); 2011/65/EU
.CE 93/68/EECΔϳ
ΑϭέϭϷΕΎϬϳΟϭΗϟΕΎΑϠρΗϣϊϳϣΟΞ˴ΗϧϣϟΫϫϲΑϠϳ
˷
˶
ΑϭέϭϷϖϓϭΗϟΔϣϼϋΞ˴ΗϧϣϟϝϣΣϳ
˷
˶
˷
ΗϻϝϭΩΔϓΎϛϲϓϪόϳίϭΗΔϳϧΎϛϣ·ϭΔϠ˶λϟΕΫ
˶
ΑϭέϭϷΕΎϔλϭϣϠϟΔϘΑΎρϣϟΔϣϼϋ
˷
˶
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.