Two Wire Videokit ESVK Series
PrtCode:ESVK_ENG_1.3 – Pag.5/24
23/10/2008 Rev.1.3
FRONT LEDS SIGNALLING DESCRIPTION
Sign Description
When illuminated, indicates that it is not possible to make a call because a call or a conversation is in progress (from the outdoor station from which you are calling or from another outdoor station on systems with multiple entrances). The LED will be
off when the system is in stand-by
If illuminated, indicates that the call from the outdoor station is in progress. The LED will switch OFF when the call is answered or after the programmed number of rings.
If illuminated, indicates that it is possible to speak because the call has been answered. The LED will switch OFF at the end
of a conversation (or at the end of the conversation time).
If illuminated, indicates that the door lock has been operated. It will switch OFF at the end of the programmed “door opening”
time.
PROGRAMMING
The programming consists of the following settings:
- Unit ID (1..8);
- Door Opening Time (3 or 6 seconds);
- Conversation Time (1 or 2 minutes);
The settings are carried out trough the 6 way dip-switch (reference j on figure 2) accessible from the rear side of the module. The switch 6 is not used.
Unit ID
Switches
1 2 3
ID
OFF OFF OFF 1
ON OFF OFF 2
OFF ON OFF 3
ON ON OFF 4
OFF OFF ON 5
ON OFF ON 6
OFF ON ON 7
ON ON ON 8
Door Opening Time
Switches
4
Seconds
OFF 3
ON 6
Conversation Time
Switches
5
Minutes
OFF 1
ON 2
SIGNALS ON SYSTEM CONNECTION TERMINALS
Terminal Description Terminal Description
BUS NO Door open relay normally open contact
BUS
Bus connection terminals
C Door open relay normally closed contact
PTE “Push to exit” active low input +C Electric lock capacitor discharge output
GND Ground
VAUX
35Vdc power supply input (if used, the module is powered
locally and not from the BUS)
GND Ground NC Door open relay normally closed contact
To use the electric lock with capacitor discharge, make a short between “C” and “+C” then connect the electric lock between terminals “NO”
and “GND”.
UNIT SPECIFICATION
Housing/Mounting
One 4000 Series Module / 4000 Series Modular System
Push Buttons
Yes, from 0 to 2 call buttons according to the model
Programming
Yes, carried out by the 6 way dip-switch located on the rear of the module
Controls
Microphone and Loudspeaker volume trimmers plus balance trimmer
Front plate Finishes
Mirror stainless steel (standard) and Anodized aluminium (add /a after the product code)
Power Supply
Supplied by the BUS line
Working Temperature
-10 +50ºC
CUSTOMER SUPPORT INFORMATION
All Countries Customers UK Customers
VIDEX Electronics S.p.A.
www.videx.it
– technical@videx.it
Tel.+39 0734 631669
Fax +39 0734 632475
VIDEX Security LTD
www.videx-security.com
Tech Line 0191 224 3174
Fax 0191 224 1559
The product is CE marked demonstrating its conformity and is for distribution within all
member states of the EU with no restrictions.
This product follows the provisions of the European Directives
89/336/EEC & 92/31/EEC (EMC),
73/23/EEC (LVD) and 93/68/EEC (CE marking).
Il prodotto è marchiato CE a dimostrazione della sua conformità e può essere distribuito liberamente all’interno dei paesi membri dell’unione eu ropea EU.
Questo prodotto è conforme alle direttive Europee
89/336/EEC & 92/31/EEC (EMC),