Videx 6400 SERIES, 6478, 6300 Series, 6378 Installation Instructions Manual

Page 1
66251320-EN - V1.5 - 31/10/16
1
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" hands free colour display videophone
PT3PT2
1
2
3
5
4
ON
DSW2
1
2
3
4
ON
SW1
PT1
VR1
DSW1
+VD
+20
V1
V/2V
GNDV
L
LB
AL
DOL
EXTC
SW
SW
12Vo
12Vi
VM
27mm
191mm
111m m
A
B C
D
H
E
G
F
Fig. 1
ART.6478 VX2200 6400 SERIES HANDS FREE VIDEOPHONE FOR SYSTEMS USING COMPOSITE VIDEO SIGNAL COAX OR BALANCED TWISTED PAIR
Surface mount hands free intelligent videophone incorporating a 4.3” Hi-Res full colour active matrix LCD monitor, with “answer/ camera recall”, “door open/concierge call”, “privacy” and one “service” button plus 3 LED’s* indicate the privacy activated , open door and activated functions. Programmable settings: video mode (coax or balanced), privacy duration, melody and number of rings. Adjustments: call tone volume (3 levels), speech volume, pic­ture hue, contrast and brightness.
* The operation of some LED’s and the functions described may require additional cabling
LEGEND
A
Connection terminals
B
8 Way dip switch bank to set videophone address
C
4 Way dip switch bank to set video mode
D
Contrast adjustment trimmer
E
Hue adjustment trimmer
F
Speech volume control
G
Brightness control
H
Call tone volume switch
PUSH BUTTON OPERATION DURING STANDBY FIG. 1
Service button When pressed, shorts terminal “SW “ to “SW “ (max 24Vdc 50mA).
Privacy service
Press to enable the privacy service. The LED “ “ turns on. The service is deactivated by pressing again the same button or when the programmed time expires.
Call the concierge
Press to book a call to the digital concierge if installed on the system.
Camera recall
Press a number of times equal to the ID value of the door panel to switch ON. The LED “ “ turns on. When the connection is made, press again to end the call.
ENG
Page 2
66251320-EN - V1.5 - 31/10/16
2
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" hands free colour display videophone
PUSH BUTTON OPERATION DURING A CALL FIG. 1
Service button When pressed, shorts terminal “SW “ to “SW “ (max 24Vdc 50mA).
Reject the call
During an incoming call, press this button to reject the call. The visitor doesn’t receive any warning of the call rejected.
Open the door
Press to activate the door open relay of the outdoor unit and end the connection. The unit emits 5 “beeps“ and the“ “ LED will ash, then returns to stand-by mode.
Answer a call
Press to answer the call and start the conversation. The“ “ LED turns on.
PUSH BUTTON OPERATIONS DURING A CONVERSATION FIG. 1
Service button When pressed, shorts terminal “SW “ to “SW “ (max 24Vdc 50mA).
Open the door
Press to activate the door open relay of the outdoor unit and end the connection after 10 seconds. The unit emits 5 “beeps“ and the“ “ LED will ash, then returns to stand-by mode.
End conversation
Press to end a call. The“ “ LED turns o.
Simplex button.
Pressing and holding the button for more than 3 seconds will switch the videomonitor into SIMPLEX speech mode. Press and hold the button to speak to the caller ( LED will ash rapidly), release the button to listen (
LED will ash slowly). If the button is not pressed
for 10 seconds the videomonitor will switch o. The videomonitor will revert to duplex speech when another call is made.
LEDS FIG. 1
LED
Privacy on LED
It illuminates when the privacy service is enabled, when pressing the service button or during pro­gramming mode.
LED
Generic use LED
It is controlled from the terminal “DOL”. Normally used to signal the door status (open or closed).
LED
ON LED
It illuminates when the videophone is switched ON or ashes quickly in “Push To Talk“ mode.
CONTROLS FIG. 1
VR1
Speech volume control
(sliding wheel).
SW1
Call tone volume switch
(3 levels).
PT1
Brightness control
(sliding wheel).
PT2
Hue adjustment trimmer
(rotate left to increase or right to decrease).
PT3
Contrast adjustment trimmer*
(rotate left to increase or right to decrease).
*Not available in some LCD versions.
PROGRAMMING
All programming options are available only when the system is in stand-by.
PRIVACY SERVICE DURATION
1. Press and keep pressed “
“ button for 10 seconds to enter privacy service duration programming mode: the “ “ LED turns on
and the unit emits a “beep“;
2. Press “ “ button as many times as required. Each press is equal to 15 minutes: the unit emits a “beep“ every time the button is
pressed. I.E.: press 4 times for 1 hour, 12 for 3 hours. Default: innite. Max value: 20 hours. To program innite privacy time don’t press any buttons;
3. Wait for some seconds: the “ “ LED turns o and the unit emits a “beep“ that conrms the new setting is properly stored;
4. The unit returns to stand-by mode.
MELODY TYPE
1. Press and keep pressed “
“ button for 10 seconds to enter melody type programming mode: the unit plays the current melody
and then a “beep“;
2. After the “beep” press “ “ buttons to select the next melody: a new melody will play for some seconds then the unit emits a
“beep“. There are 9 melodies available. Note: press “ “ buttons only after the melody is over and the unit emits the “beep“;
3. When desired melody is playing, wait for some seconds: the unit completes the melody and emits a “beep”, then the unit emits a dou­ble “beep“ that conrms the new setting is properly stored;
4. The unit returns to stand-by mode.
Note: To set the melody it is required that the videophone is connected in a system where the +20Vdc voltage from Art.893N1 is always enabled.
Page 3
66251320-EN - V1.5 - 31/10/16
3
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" hands free colour display videophone
NUMBERS OF RINGS
1. Press and keep pressed “
“ button for 10 seconds to enter numbers of rings programming mode: the “ “ LED turns on and the
unit emits a “beep“;
2. Press “ “ button as many rings as required: the unit emits a “beep“ every time the button is pressed. I.E.: press 3 times for 3 rings. Default value: 6 rings. Max value: 9 rings;
3. Wait for some seconds: the “ “ LED turns o and the unit emits a “beep“ that conrms the new setting is properly stored;
4. The unit returns to stand-by mode.
VIDEO MODE SW2
The video mode setup is carried out by the 4 way Dip-Switch accessible from the rear side of the videophone.
Switches 3 and 4 adjust the video signal impedance. When using more than one videomonitor in parallel (without a video splitter) put both switches in the OFF position on all but the last videomonitor (end of line).
VIDEO MODE
Switches 1,2 Mode
Coax
Balanced
75 OHM VIDEO TERMINATION
Switches 3,4 Termination
Enabled
Disabled
VIDEOMONITOR/INTERCOM ADDRESS, VIDEO MODE AND TERMINATION SETUP DSW1
Each intercom is addressed in binary (PHONE ID) using the 8 way dipswitches located on the rear of the unit. Each switch corre­sponds to one bit which can have a value 0 (OFF) or 1 (ON). Each bit corresponds to a decimal weight depending on the position: Switch 1 = decimal 1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. I.E. to set the address 37, put switches 1, 3 and 6 on (1+4+32=37).
SWITCHES DECIMAL WEIGHT ADDRESS
8 7 6 5 4 3 2 1 128 64 32 16 8 4 2 1
OFF OFF OFF OFF OFF OFF OFF ON 0 0 0 0 0 0 0 1 1 OFF OFF OFF OFF OFF OFF ON OFF 0 0 0 0 0 0 1 0 2 OFF OFF OFF OFF OFF OFF ON ON 0 0 0 0 0 0 1 1 3 OFF OFF OFF OFF OFF ON OFF OFF 0 0 0 0 0 1 0 0 4
OFF OFF ON OFF OFF ON OFF ON 0 0 1 0 0 1 0 1 37
ON OFF ON ON OFF ON OFF OFF 1 0 1 1 0 1 0 0 180
CABLING 6478 USING CAT.5 CABLE* Connections:
• One pair must be used to double up the BUS line “L”;
• One pair must be used to double up the power supply ground. The bus ground
must be connected with power supply ground (“GNDV” & “–”);
• One pair must be used to double up the positive power supply +20V;
• One pair must be used for the video signals “V1” and “V/V2”;
• A link is required between “12Vo” & “12Vi”;
• An additional PSU Art.893N1 is required every 50 videomonitors installed in the system.
Max Distance**: 70 metres. System type: Audio/video door entry systems.
* When this cable is used, in case more videophones are connected in parallel in the same apartment, a local power supply for additional videophones is required. ** By max distance we mean the maximum distance between the door panel and the furthest videophone/intercom
Page 4
66251320-EN - V1.5 - 31/10/16
4
6400 Series
Art.6478 - Installation instructions
ART.6478  SIGNALS
+VD
12Vdc output to supply coax video distributor Art.894N
+20 Video power supply 17÷20Vdc
V1 Balanced video signal V1 sync. (balanced video signal mode)
V/V2
Balanced video signal V2 sync. (balanced video signal mode) Composite video signal (coax video signal mode)
GNDV Video power supply ground reference
L BUS line
BUS line ground reference
LB Local bell input (active low) AL Alarm input (active low)
DOL 12Vdc input to supply Aux LED
EXTC Call tone output for extension sounder (Art.512A)
SW Service button connection
Max 24 Vdc
50mA
SW Service button connection
12Vo +12Vdc stabilized output
12Vi Stand-by +12Vdc power supply input
Power supply ground input / coax video ground
VM
Auxiliary input 200mA 12Vdc for video memory (Art.6478/VM)
TECHNICAL SPECIFICATION Working Voltage: 17÷20Vdc
Power Consumption: Standby: 10mA
During a conversation: 150mA Max: 250mA
Working Temperature: -10°C +50°C
MEMORY BOARD
This device is also available in the version with memory board (Art.6478/VM).
If you have that version, please refer to the “6200, 6300, 6400 and 6700 Series Memory Board” user manual for installation and use. The manual is available for download at the following link:
https://www.dropbox.com/s/492p16btyqhxmpu/66250782-EN.pdf?dl=0
Art.6478 4.3" hands free colour display videophone
Page 5
66251320-EN - V1.5 - 31/10/16
5
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" colour display videophone
ON/OFF
+
13V
ART.521B
115
0
swsw
+B
+12
_
L
BSSLNCCNO
TRD
PTE
V1
V2 / V
GNDV
12T
B.V.
coax
others
316x
GND
Art.4202RV
A
SE
12Vac
ART.893N1
0
Videx Electronics S.p.A.
Via del Lavoro 1, 63846 Monte Giberto (FM)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:Title:
Notes:
Titolo:
Note:
Cod.File:
Foglio
/
07/07/2015
07/07/2015
224kvd119a.dw
g
Marco Rongoni
11
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
1
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
2
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
4
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
3
Art.6478
Page 6
66251320-EN - V1.5 - 31/10/16
6
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" colour display videophone
ON/OFF
+
13V
ART.521B
115
0
swsw
+B
ART.893N1
0
Videx Electronics S.p.A.
Via del Lavoro 1, 63846 Monte Giberto (FM)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:
Title:
Notes:
Titolo:
Note:
Cod.File:
Foglio
/
07/07/2015
06/07/2015
224kvd120a.dw
g
Marco Rongoni
11
1C
Art.4845
SE
12Vac
1
2
3
4
87465321ON109
Unit ID:
1
Art.4283-1
6
5
blu giallo
87465321ON109
Unit ID:
1
Art.4283-1
SE
12Vac
12Vac
Dry Contact Relay
Relè a contatti puliti
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
1
Art.6478/MV
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
2
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
4
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
3
Art.6478
12Vdc
Art.AMR2-12
It is required an additional power supply for videophones with memory board. For Art.6478/MV it is required 1 AMR2-12 each 8 videophones with memory board
Page 7
66251320-EN - V1.5 - 31/10/16
7
6400 Series
Art.6478 - Installation instructions
Art.6478 4.3" colour display videophone
Videx Electronics S.p.A.
Via del Lavoro 1, 63020 Monte Giberto (AP)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:Title:
Notes:
Titolo:
Note:
Cod.File:
Foglio
/
07/07/2015
07/07/2015
228kvd001b.dw
g
Marco Rongoni
11
SE
12Vac
ON
1
b
8203-0
BALANCE
2 1
6
4 3
5
8 7
a
+12 Gnd
SL
L
BS
C
NC
NO
f
d c
e
h g
87342 5 6
Coax
NC
Art.8830
Art.8844
+
13V
ART.521B
115
0
swsw
+B
ART.893N1
0
1
2
3
4
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
1
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
2
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
4
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
3
Art.6478
Page 8
66251320-EN - V1.5 - 31/10/16
8
6400 Series
Art.6478 - Installation instructions
Videx Electronics S.p.A.
Via del Lavoro 1, 63846 Monte Giberto (FM)
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
Autore:
Data modifica:
Data creazione:Title:
Notes:
Titolo:
Note:
Cod.File:
Foglio
/
07/07/2015
07/07/2015
228kvd013c.dw
g
Marco Rongoni
11
sw
ART.521B
1150 sw +
+B
ART.893N1
0
SE
12Vac
BALANCE
Art.8202-8202R
Coax
NC
Art.8830
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
1
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
2
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
4
Art.6478
Address N.
BALANCED
+VD
+20
V1
V/V2
GNDV
-
LB
DOL
EXTC
SW
SW
12Vo
AL
L
12Vi
-
VM
3
Art.6478
Art.6478 4.3" colour display videophone
Page 9
66251320-EN - V1.5 - 31/10/16
9
6400 Series
Art.6478 - Installation instructions
1. In order to install the videophone, it is necessary to remove the cover, which contains all the electronics, from the base: press
lightly on the right part of the videophone and simultaneously pulling outwards the left part as shown in Fig. 1.
2. Put the base of the unit on the wall at approx 135cm from the nished oor to match the points for the xing holes “A” (Fig. 2) remembering that the wires “D” (Fig. 3) must be fed through the large hole “E” (Fig. 3). If you use the ush mounting box 503, embed it into the wall vertically at approx. 140cm from the nished oor and the base.
3. Following Fig. 3, make the holes “A”, insert the wall plugs “B” and x the base with the screws “C” feeding the wires “D” through the hole “E”. If you have used the box 503, x the base to the wall through the holes “F” using the screws “C”.
4. As shown in Fig. 4, connect the wires to the removable terminals following the provided installation diagram. Connect the terminal blocks to the electronics contained in the cover as shown in Fig. 5. Test system before closing. Contrast and hue trimmers can be adjusted only if the videophone is open. To activate the display and see changes use the “Camera Recall” function by pressing
button.
Note: while testing the system, it is advisable to hold the cover with your hand.
5. Once testing is complete and all the necessary adjustments are made, close the unit as shown in Fig. 6: rst hook in the right part and then the left part until you hear a click.
1
2
Fig. 1
Fig. 4
135cm
Fig. 2
Fig. 5
C
E
C
A
A
B
D
B
F
F
Fig. 3
2
1
Fig. 6
6400 Series Wall mounting instructions
Page 10
66251320-EN - V1.5 - 31/10/16
10
6400 Series
Art.6478 - Installation instructions
Note
Page 11
66251320-EN - V1.5 - 31/10/16
11
6400 Series
Art.6478 - Installation instructions
Note
Page 12
MANUFACTURER
VIDEX ELECTRONICS S.P.A.
Via del Lavoro, 1 - 63846 Monte Giberto (FM) Italy Tel (+39) 0734 631669 - Fax (+39) 0734 632475 www.videx.it - info@videx.it
CUSTOMER SUPPORT
All Countries:
VIDEX ELECTRONICS S.P.A.
www.videx.it - technical@videx.it Tel: +39 0734-631669 - Fax: +39 0734-632475
UK Customers:
VIDEX SECURITY LTD
www.videx-security.com Tech Line: 0191 224 3174 - Fax: 0191 224 1559
The product is CE marked demonstrating its conformity and is for distribution
within all member states of the EU with no restrictions. This product follows the provisions of the European Directives 2014/30/EU (EMC); 2014/35/EU (LVD); 2011/65/EU (RoHS): CE marking 93/68/EEC.
Main UK oce:
VIDEX SECURITY LTD
1 Osprey Trinity Park Trinity Way LONDON E4 8TD Phone: (+44) 0870 300 1240 Fax: (+44) 020 8523 5825 www.videx-security.com marketing@videx-security.com
Northern UK oce:
VIDEX SECURITY LTD
Unit 4-7 Chillingham Industrial Estate Chapman Street NEWCASTLE UPON TYNE - NE6 2XX Tech Line: (+44) 0191 224 3174 Phone: (+44) 0870 300 1240 Fax: (+44) 0191 224 1559
Greece oce:
VIDEX HELLAS Electronics
48 Filolaou Str. 11633 ATHENS Phone: (+30) 210 7521028 (+30) 210 7521998 Fax: (+30) 210 7560712 www.videx.gr videx@videx.gr
Danish oce:
VIDEX DANMARK
Hammershusgade 15 DK-2100 COPENHAGEN Phone: (+45) 39 29 80 00 Fax: (+45) 39 27 77 75 www.videx.dk videx@videx.dk
Benelux oce:
NESTOR COMPANY NV
E3 laan, 93 B-9800 Deinze Phone: (+32) 9 380 40 20 Fax: (+32) 9 380 40 25 www.videx.be info@videx.be
Dutch oce:
NESTOR COMPANY BV
Business Center Twente (BCT) Grotestraat, 64 NL-7622 GM Borne www.videxintercom.nl info@videxintercom.nl
Loading...