Art.5178N Hands free intercom
164,00
24,50
1 2 3 4 5 6 7 8 9
!
10
Fig. 1
DESCRIPTION
Voice switched hands free intercom with buttons to control “answer/end conversation/recall/simplex conversation”, “door open”, “privacy on/o” (programmable duration) and “service” button. In addition there are 4 LED’s* to indicate the status of “answer/ end conversation”, “door open/closed”, “privacy on/ o” and auxiliary “service” status. Call tone and loudspeaker volume controls, through assigned buttons, are also incorporated on this model. It is possible to program the melody (9 available), the number of rings (max 9) and the privacy service duration (max 20 hours). Surface wall mount installation.
* The operation of some LED’s and the functions described may require additional cabling
PUSH BUTTONSAND CONTROLS
Service Push Button.
When pressed, shorts internally terminal 1 (“Sb”) and 8 (“Sa”).
Answer / simplex communicaiton / Camera Recall / End Call push button.
• Pressing this button during an incoming call will open the speech in duplex mode allowing free speech with the caller in both directions (The LED next to this button will illuminate)
• Pressing and holding this button will allow the user to answer a call from a visitor at the door station in SIMPLEX speech mode (The LED next to the button will ash rapidly): releasing the button will allow the user to listen to the visitor (The LED next to the button will ash slowly). Press and hold the button when you talk to the visitor and release the button when you listen to the visitor.
• When the system is in standby, (No calls on the system) operation of this button will open the speech to the door station. The LED next to the button will illuminate.
• During a conversation, momentary operation of this button will end the call. The LED next to the button will switch o. The system will automatically switch o when the conversation time expires.
Privacy on/o Push Button.
This button Enables / Disables the privacy function. When privacy is enabled calls will not be received and the LED next to the button will be illuminated. The duration of the privacy time is set when in the programming mode, pri­vacy can be disabled at any time by operation of this Push Button.
Door Open Push Button.
During a call, operation of this button will release the door from where the call originated. This will be conrmed by an acoustic tone. If terminal 10 (LD1) is connected, the “door open” LED next to the button will also be illuminated.
Speech line volume control. Adjust during a conversation. Press the right button to increase or the left button to decrease.
Melody volume control. Adjust when the intercom is in standby. Press the right button to increase or the left button to decrease.
66250730-EN - V2.0 - 09/10/15
2
5000 Series Eclipse Range
Art.5178N - Installation instructions
PROGRAMMING MELODIES PROGRAMMING FACTORY PRESET MELODY 1
• Press and hold the two melody buttons
(for approx 10 seconds) until the unit plays the current stored melody and emits a beep.
• Press the melody button again (left or right) to listen to the available melodies (maximum 9).
• When the chosen melody has been reached, do not press any buttons wait 3 seconds for the exit beep.
• The new melody is now stored.
NUMBER OF RINGS PROGRAMMING FACTORY PRESET = 6 RINGS
• Press and hold the
button (for approx 10 seconds) until the unit emits a beep.
• Press the
button as many times as the number of rings required (i.e. 6 presses = 6 rings with a maximum of 9 rings)
• Once the number of rings required has been reached, wait 3 seconds for the exit beep.
• The new value is now stored.
PRIVACY DURATION PROGRAMMING FACTORY PRESET = WITHOUT TIME OUT
• Press and hold the
button (for approx 10 seconds) until the unit emits a beep.
• Press the
button again to set the privacy duration. Each time the button is pressed, it will increase the privacy duration by 15 minutes (starting from 0 up to a maximum of 20 hours i.e. pressing the button 8 times = 2 hours up to a maximum of 80 presses for 20 hours). Once the required privacy duration has been reached, wait 3 seconds for the exit beep.To set the privacy with no
time out Press and hold the
button (for approx 10 seconds) until the unit emits a beep do not press any other button wait
3 seconds for the exit beep.
• The new value is now stored.
RESTORE TO FACTORY PRESET
• Power on the intercom keeping pressed the
;
• The intercom will emit a beep to conrm the operation;
• Release the
button.
ENABLE DOOR PANEL AUDIO RECALL FUNCTION FACTORY PRESET = DISABLED
• Remove the intercom cover and disconnect it from the BUS
• Keeping pressed the
button reconnect the intercom to the BUS
• When the privacy LED ashes once to conrm that the function is enabled, release the button.
INTERCOM ADDRESS SETUP
Each intercom address is binary (PHONE ID) using the 8 way dipswitches located on the rear of the unit. Each switch correspond to one bit which can have a value 0 (OFF) or 1 (ON). Each bit corresponds to a decimal weight depending on the position: Switch 1 = decimal 1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. I.E. to set the address 37, put switches 1, 3 and 6 on (1+4+32=37).
SWITCHES DECIMAL WEIGHT ADDRESS
8 7 6 5 4 3 2 1 128 64 32 16 8 4 2 1
OFF OFF OFF OFF OFF OFF OFF ON 0 0 0 0 0 0 0 1 1 OFF OFF OFF OFF OFF OFF ON OFF 0 0 0 0 0 0 1 0 2 OFF OFF OFF OFF OFF OFF ON ON 0 0 0 0 0 0 1 1 3 OFF OFF OFF OFF OFF ON OFF OFF 0 0 0 0 0 1 0 0 4
OFF OFF ON OFF OFF ON OFF ON 0 0 1 0 0 1 0 1 37
ON OFF ON ON OFF ON OFF OFF 1 0 1 1 0 1 0 0 180
Art.5178N Hands free intercom
66250730-EN - V2.0 - 09/10/15
3
5000 Series Eclipse Range
Art.5178N - Installation instructions
Art.5178N Hands free intercom
INTERCOM CONNECTION BOARD
A
B
JP1
1 2 3 4 5 6 7 8 9
10
Fig. 2
SIGNALS ON CONNECTION TERMINALS
Terminal Signal Description
1 Sb
button terminal 1
2 –LD “Aux” and “Door Open” LEDs ground 3 +12V +12Vdc power supply input 4 GND “Bus” line ground 5 L “Bus” line data 6 LB Local bell input 7 AL Active low alarm input
8 Sa
button terminal 2
9 AUL “Aux” LED power supply input +12Vdc
10 DOL
“Door Open” LED power supply input +12Vdc
TECHNICAL SPECIFICATION
Housing/Mounting: 5000 Series Intercoms / direct wall mount Push buttons: Yes, 4 Programming: Yes, carried out by the dip-switches located on the rear of the videophone Controls: Loudspeaker and call tone volume Power Supply: Supplied by the BUS line Power consumption: Stand-by: 7mA
Max: 100mA Working Temperature: -10 +50 °C