Door open time 22 X X = 0 to 9 (0 = 1 second, 1 - 9 multiplied by 2, i.e. if X = 3 then time =
6 seconds; if X = 4 then time = 8 seconds).
3 14
Door open key 23 X X = 0, 8 or 9. 0 14
Divert call/ dial in time 24 X X = 0 to 9 (X multiplied by 30 seconds = time, i.e. if X = 2 then time =
60 seconds; if X = 4 then time = 120 seconds).
2 15
Dial in answer after a
number of rings
25 X X = 0 to 9 (0 = 10 rings, 1 - 9 = number of rings before automatically
answering).
5 15
Tone detection 26 X X = 1 or 0 (1 to enable tone detection and 0 to disable tone detection). 1 17
Speech volume towards
the entrance panel
27 X X = 1 to 9 (1 = lowest volume and 9 = maximum volume). 5 17
A1 auxiliary output
control
28 X X = 1 or 0 (1 for momentary trigger and 0 for latching trigger). 1 14
A2 auxiliary output
control
29 X X = 1 or 0 (1 for momentary trigger and 0 for latching trigger). 1 14
At home control 30 X X = 1 or 0 (1 to disable home control and 0 to activate home control). 1 17
Access code 31 XXXX X = 4 digit access code (note that this code must begin with either
1, 2, 3 or 4).
no code 16
Divert phone number 321 n # n = telephone number (e.g. to program the number 0123 456789
would be 321 0123456789#, always conrm the number with the #
key at the end. A minimum of 3 digits can be used for the number).
N/A 15
Revert to default settings
(reset)
33 1111 Resets all settings back to factory default. N/A 13
Reassurance tone at the
door panel
34 X X = 1 or 0 (1 to activate the reassurance tone and 0 to deactivate the
reassurance tone).
0 17
Divert to number after n
seconds
35 X X = 0 to 9 (0 to disable the divert and 1 - 9 multiplied by 4 = time, i.e.
if X = 3 then time = 12 seconds before automatic divert).
0 15
Divert mode audio
automatically ON/OFF
36 X X = 1 or 0 (1 to manually open the speech by pressing 2 after
answering the call and 0 to enable the speech automatically).
0 16
PROGRAMMING AND USER FUNCTIONS EXPLAINED
INITIAL SETUP AND RESET
Begin by resetting the Art.380N/UK to the factory defaults using the programming command: ** 371 33 1111.
IMPORTANT NOTE: If you are unable to reset using this process because an access code has been enabled but you are not sure
what it is then follow the manual reset procedure:
1. Switch OFF the mains power to the Art.380N/UK;
2. Short out the terminals - and SK, see Fig.17;
3. Switch ON the mains power to the Art.380N/UK;
4. Remove the short between terminals - and SK, see
Fig.18;
5. The Art.380N/UK has now been reset to the factory
default settings.
This method will also switch the Art.380N/UK into PABX mode
so unless this mode is required in order to revert the unit back
to normal mode, pickup the handset and type ** 371 14 0 and
listen for the line tone to change to the normal dial tone.
Fig. 17
Fig. 18
Programming the Art.380N/UK