Videx 3676 Installation Manual

66251010-EN - V2.1 - 31/05/16
1
3600 Series
Art.3676 - Installation instructions
161
178
62
46
Fig. 1
678
1
2
3
5
4
ON
SW1
1
2
3
4
ON
SW2
1
2
3
ON
SW3
Fig. 2
DESCRIPTION
Intelligent videophone for the VX2200 digital system incorporating a 3,5” full colour active matrix LCD monitor, with “camera recall”, “door open”, “privacy/service” buttons plus 3 LEDs related to the operation of the buttons. Programmable settings: video mode (coax or balanced), melody, number of rings and privacy duration. Adjustments: call tone volume (3 levels), hue and brightness. Connection terminals are compatible with Art.3678.
PUSH BUTTONS AND CONTROLS  OPERATION
Camera recall button.
When the system is in standby, (No calls on the system) operation of this button will open the speech to the door station. The related LED will illuminate. Press as many time as the ID value of the door panel to connect to.
Door-open button.
• During a conversation, operation of this button will release the door from where the call originated. This will be con­rmed by an acoustic tone. If terminal “DL” is connected, the “door open” LED next to the button will also be illuminated.
• When the system is in stand-by, a button press will book a call to the concierge (If available).
Privacy ON-OFF button.
• When the system is in stand-by, press this button to enable the service for the programmed time: the related LED will illuminate to signal the service enabled. During an incoming call, with the service enabled, the device does not emit any acoustic signal. The service is disabled when the programmed time expires or pressing again the button.
• During a conversation, press this button to enable the auxiliary service: by pressing the button terminal “12/SB” is internally linked to ground for 2 seconds.
Adjusts call tone volume (3 levels): low, medium and high.
Adjusts the picture hue: right rotation to increase, left rotation to decrease.
Adjusts the picture brightness: right rotation to increase, left rotation to decrease.
Art.3676 Digital videophone for VX2200 Digital System
66251010-EN - V2.1 - 31/05/16
2
3600 Series
Art.3676 - Installation instructions
PROGRAMMING AND ADJUSTMENTS
The programmable settings are:
• Melody (9 available);
• Number of rings (3 or 6);
• Video mode (coax or balanced);
• Privacy duration (15minutes – 16 hours or unlimited);
• Videophone address (Phone ID).
TO SET MELODY
Press and hold (for approx 10 seconds) the “
” button un­til the unit plays the current programmed melody and emits a beep at the end. Press again the “ ” button to listen to the available melodies (maximum 9). Once the selected melody has been reached, wait 5 seconds for a beep. The new melody will be stored.
TO SET THE NUMBER OF RINGS 6 OR 3
Default setting is 6, to set 3 proceed as follows: a. Turn o the videophone by unplugging the at cable from
the PCB connection board;
b. Make a short between terminals 8 and 9 (signals “GND” and
“LB”) of the PCB connection;
c. Plug the at cable onto the PCB connection board and wait for
a beep before removing the short between terminals 8 and 9;
d. To go back to 6 rings, do the same but two beeps will be emitted.
TO SET THE VIDEO MODE
The videophone can operate with ei­ther composite video signal (coax cable) or balanced video signal (two wires). Switches 1 & 2 of SW2 are used to set vid­eo mode while switches 3 & 4 are for vid­eo termination. When more videophone have a pass through connection for the video signal, you must enable the video termination only for the last videophone.
VIDEO MODE  SW2
Switches 1,2 Mode
Coax
Balanced
75 OHM VIDEO TERMINATION  SW2
Switches 3,4 Termination
Enabled
Disabled
TO SET THE PRIVACY DURATION
The privacy duration is set by the 3 way dip-switch bank SW3.
PRIVACY DURATION  SW3
SW3
Dip-Switch
Duration
1 2 3
o o o Unlimited
on o o 15 min
o on o 30 min
on on o 1 hour
o o on 2 hours
on o on 4 hours
o on on 8 hours
on on on 16 hours
Art.3676 Digital videophone for VX2200 Digital System
66251010-EN - V2.1 - 31/05/16
3
3600 Series
Art.3676 - Installation instructions
VIDEOMONITOR/INTERCOM ADDRESS, VIDEO MODE AND TERMINATION SETUP
Each intercom is addressed in binary (PHONE ID) using the 8 way dipswitches located on the rear of the unit. Each switch corre­sponds to one bit which can have a value 0 (OFF) or 1 (ON). Each bit corresponds to a decimal weight depending on the position: Switch 1 = decimal 1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. I.E. to set the address 37, put switches 1, 3 and 6 on (1+4+32=37).
SWITCHES DECIMAL WEIGHT ADDRESS
8 7 6 5 4 3 2 1 128 64 32 16 8 4 2 1
OFF OFF OFF OFF OFF OFF OFF ON 0 0 0 0 0 0 0 1 1 OFF OFF OFF OFF OFF OFF ON OFF 0 0 0 0 0 0 1 0 2 OFF OFF OFF OFF OFF OFF ON ON 0 0 0 0 0 0 1 1 3 OFF OFF OFF OFF OFF ON OFF OFF 0 0 0 0 0 1 0 0 4
OFF OFF ON OFF OFF ON OFF ON 0 0 1 0 0 1 0 1 37
ON OFF ON ON OFF ON OFF OFF 1 0 1 1 0 1 0 0 180
SIGNALS ON CONNECTION BOARD
+20V 1 Video power supply 17÷20Vdc +20V 2 Video power supply 17÷20Vdc
GND 3 Video power supply ground reference GND 4 Video power supply ground reference
V2/V 5
Balanced video signal V2 sync.(balanced video signal mode) Composite video signal (coax video signal mode)
V1 6 Balanced video signal V1 sync.(balanced video signal mode)
L 7 BUS line
GND 8 BUS line ground reference
LB 9 Local bell input (active low) AL 10 Alarm input (active low)
11
SB 12 Service Push button (close to ground when pressed)
EXTC 13 Call tone output for extension sounder like Art.512A
14 +VD 15 +12Vdc output to supply the video distributor Art.894/Art.894N GND 16 Ground
LDO 19
Auxiliary LED (
button) power supply input
GND 20 Ground
TECHNICAL SPECIFICATION
Working Voltage: 17÷20Vdc Power Consumption: Standby: 12mA
During a conversation: 250mA Max (on 20Vdc)
Working Temperature: -10°C +50°C
Art.3676 Digital videophone for VX2200 Digital System
Loading...