VX2300 2 Wire Video Digital System
PrtCode:VX2300_2_9.doc – Pag.10 08/03/2011 Rev.2.9
SIGNALS ON SYSTEM CONNECTION TERMINALS
Terminal Description Terminal Description
1 Common terminal for addresses 1..8 (switch 6 = OFF) or
65..72 (switch 6 = ON)
E
Addresses 5,13,21,29,37,45,53, 61 (switch 6 = OFF)
Addresses 69,77,85,93,101,109,117, 125 (switch 6 = ON)
2 Common terminal for addresses 9..16 (switch 6 = OF F) or
73..80 (switch 6 = ON)
F
Addresses 6,14,22,30,38,46,54, 62 (switch 6 = OFF)
Addresses 70,78,86,94,102,110,118, 126 (switch 6 = ON)
3 Common terminal for addresses 17..24 (switch 6 = OFF) or
81..88 (switch 6 = ON)
G
Addresses 7,15,23,31,39,47,55, 63 (switch 6 = OFF)
Addresses 71,79,87,95,103,111,119, 127 (switch 6 = ON)
4 Common terminal for addresses 25..32 (switch 6 = OFF) or
89..96 (switch 6 = ON)
H
Addresses 8,16,24,32,40,48,56, 64 (switch 6 = OFF)
Addresses 72,80,88,96,104,112,120, 128 (switch 6 = ON)
5 Common terminal for addresses 33..40 (switch 6 = OFF) or
97..104 (switch 6 = ON)
BUS
BUS Connection terminals
6 Common terminal for addresses 41..48 (switch 6 = OFF) or
105..112 (switch 6 = ON)
BUS
7 Common terminal for addresses 49..56 (switch 6 = OFF) or
113..120 (switch 6 = ON)
PTE Active low input push to exit signal
8 Common terminal for addresses 57..64 (switch 6 = OFF) or
121..128 (switch 6 = ON)
GND Ground
A
Addresses 1,9,17,25,33,41,49, 57 (switch 6 = OFF)
C Door open relay common contact
Addresses 65,73,81,89,97,105,113, 121 (switch 6 = ON)
B
Addresses 2,10,18,26,34,42,50, 58 (switch 6 = OFF)
NC Door open relay normally closed contact
Addresses 66,74,82,90,98,106,114, 122 (switch 6 = ON)
C
Addresses 3,11,19,27,35,43,51, 59 (switch 6 = OFF)
NO Door open relay normally open contact
Addresses 67,75,83,91,99,107,115, 123 (switch 6 = ON)
D
Addresses 4,12,20,28,36,44,52, 60 (switch 6 = OFF)
VAUX
35Vdc power supply input (if used, the module is powered
locally and not from the BUS)
Addresses 68,76,84,92,100,108,116, 124 (switch 6 = ON)
BUTTONS MATRIX
The button, when pressed, will generate a call to a specific address according to the terminals to which the button is connected: i.e. a button connected between terminals “2” and “B”, when pressed will generate a call to the address 10 if the dip-switch 6= OFF or a call to the address 74 if the
switch 6=ON.
SW6
OFF
1 2 3 4 5 6 7 8
A 1 9 17 25 33 41 49 57
B 2 10 18 26 34 42 50 58
C 3 11 19 27 35 43 51 59
D 4 12 20 28 36 44 52 60
E 5 13 21 29 37 45 53 61
F 6 14 22 30 38 46 54 62
G 7 15 23 31 39 47 55 63
H 8 16 24 32 40 48 56 64
SW6
ON
1 2 3 4 5 6 7 8
A 65 73 81 89 97 105 113 121
B 66 74 82 90 98 106 114 122
C 67 75 83 91 99 107 115 123
D 68 76 84 92 100 108 116 124
E 69 77 85 93 101 109 117 125
F 70 78 86 94 102 110 118 126
G 71 79 87 95 103 111 119 127
H 72 80 88 96 104 112 120 128
UNIT SPECIFICATION
Housing/Mounting
One 4000 Series Module / 4000 Series Modular System
Push Buttons
Yes, from 0 to 2 call buttons according to the model
Programming
Yes, carried out by the 8 way dip-switch located on the rear of the module
Controls
Microphone and Loudspeaker volume trimmers plus balance trimmer
Front plate Finishes
Mirror stainless steel (standard) and Anodized aluminium (add /a after the product code)
Power Supply
Supplied by the BUS line
Working Temperature
-10 +50ºC
CUSTOMER SUPPORT INFORMATION
All Countries Customers UK Customers
VIDEX Electronics S.p.A.
www.videx.it – technical@videx.it
Tel.+39 0734 631669
Fax +39 0734 632475
VIDEX Security LTD
www.videx-security.com
Tech Line 0191 224 3174
Fax 0191 224 1559
The product is CE marked demonstrating its conformity and is for distribution within all
member states of the EU with no restrictions.
This product follows the provisions of the European Directives
89/336/EEC & 92/31/EEC (EMC),
73/23/EEC (LVD) and 93/68/EEC (CE marking).
Il prodotto è marchiato CE a dimostrazione della sua conformità e può essere distribuito liberamente all’interno dei paesi membri dell’unione europea EU.
Questo prodotto è conforme alle direttive Europee
89/336/EEC & 92/31/EEC (EMC),
73/23/EEC (LVD) e 93/68/EEC (Marcatura CE).