1 About this manual

Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference.

1.1 Typographical conventions

DANGER! High level hazard. Risk of electric shock. Disconnect the power supply before proceeding with any operation, unless indicated otherwise.
WARNING! Medium level hazard. This operation is very important for the system to function properly. Please read the procedure described very carefully and carry it out as instructed.
INFO Description of system specications. We recommend reading this part carefully in order to understand the subsequent stages.

2 Notes on copyright and information on trademarks

The quoted names of products or companies are trademarks or registered trademarks.

3 Safety rules

The manufacturer declines all responsibility for any damage caused by an improper use of the appliances mentioned in this manual. Furthermore, the manufacturer reserves the right to modify its contents without any prior notice. The documentation contained in this manual has been collected with great care, the manufacturer, however, cannot take any liability for its use. The same thing can be said for any person or company involved in the creation and production of this manual.
• The device must be installed only and exclusively by qualied technical personnel.
• Before any technical work on the appliance, disconnect the power supply.
• Do not use power supply cables that seem worn or old.
• Never, under any circumstances, make any changes or connections that are not shown in this handbook: improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
• Use only original spare parts. Non-original spare parts could cause re, electrical discharge or other hazards.
• Before proceeding with installation check the supplied material to make sure it corresponds to the order specication by examining the identication labels (4.2 Product markings, page 2).
4 Identification

4.1 Product description and type designation

5l (1.3gal) o 23l (6gal) tank. Dierent pumps are available for delivery up to 5m (16ft), 11m (36ft) or 30m (98ft). Available voltages in 230Vac, 24Vac or 120Vac. Pumps with 30m (98ft) delivery are available only in 230Vac or 120Vac.
In the 30m (98ft) delivery version the lack of liquid in the tank is signalled following the automatic stop of the pump.
EN - English - Instructions manual

4.2 Product markings

See the label attached to the outside of the package.

5 Preparing the product for use

Any change that is not expressly approved by the manufacturer will invalidate the guarantee.

5.1 Safety precautions before use

In the 115/230Vac powered conguration it is necessary to insert a 1 0 unipolar main switch (open contact distance d>3mm). This switch should be used to disconnect the power supply before carrying out any maintenance operation or before opening the procuct.

5.2 Unpacking and contents

5.2.1 Unpacking
When the product is delivered, make sure that the package is intact and that there are no signs that it has been dropped or scratched.
If there are obvious signs of damage, contact the supplier immediately.
Keep the packaging in case you need to send the product for repairs.
5.2.2 Contents
Check the contents to make sure they correspond with the list of materials as below:
• Washer kit
• Clamp
• Silicon sheath
• Washer pipe
• Instructions manual
5.3 Safely disposing of packaging
material
The packaging material can all be recycled. The installer technician will be responsible for separating the material for disposal, and in any case for compliance with the legislation in force where the device is to be used.
When returning a faulty product we recommend using the original packaging for shipping.

6 Assembling and installing

Only specialised personnel should be allowed to assemble and install the device.
Before starting any operation, make sure the power supply is disconnected.
2

6.1 Installation

6.1.1 Installing the pump tank
If using the pump at temperatures below 3°C (37.4°F) add some antifreeze liquid to the water.
The antifreeze liquid will cause irreparable damage to the germanium glasses. For pan & tilts tted with germanium glasses, do not use antifreeze liquid but add ethyl alcohol in 20% solution.
Attach the metal cage (01) rmly to a wall using the holes provided for this (02).
01
02
Fig. 1 Water tank 5l (1.3gal), 5m (16ft) delivery.
Instructions manual - English - EN
01
02
Fig. 3 Water tank 23l (6gal), 30m (98ft) delivery.
Take the plug out of the tank, along with any pumps and level gauges. Remove the tank from the metal cage.
6.1.2 Choose the power supply line
Depending on the version, the device can be provided with dierent power supply voltages. Their value is shown on the product identication label.
Always make the electrical connections with the power supply disconnected and the circuit-breaker open.
01
02
Fig. 2 Water tank 23l (6gal), 5m (16ft) or 11m (36ft) delivery.
When commencing installation make sure that the specications for the power supply for the installation correspond with those required by the device.
Make sure that the power source and connecting cables are suitable for the power consumption of the system.
3
6.1.3 Open the box
Operation valid for pump with 5m (16ft) or 11m (36ft) delivery.
Open the cover of the water-proof box and connect as described below.
6.1.4.1 Installing the fuse
Move the fuse into the correct fuse holder according to the input voltage.
230V
120V
24V
EN - English - Instructions manual
Fig. 4
6.1.4 Connection of the board
Operation valid for pump with 5m (16ft) or 11m (36ft) delivery.
Find the position of the following on the pump control board: fuses (01), power supply terminal J5(02) and pump connector J3(03).
FUS1
Fig. 6
FUS2
FUS3
The pump is supplied with the fuse in position FUS1 (for a 230Vac power supply).
If the power supply is dierent position the fuse correctly referring to the following table.
INSTALLING THE FUSE
Voltage Fuse holder
230Vac Fuse in FUS1 120Vac Fuse in FUS2 24Vac Fuse in FUS3
Tab. 1
6.1.4.2 Connection of the power supply line
The power supply cable should also be covered by the silicone sheath (01) supplied for this purpose, and fastened with the corresponding tie (02).
01
02
01
Neutral (N)
Phase (L)
Fig. 5
4
02
Fig. 7
Connect the power supply terminal J5 (02) to the electric network using a suitably sectioned cable (minimum 1.5mm²) (Fig. 5, page4).
Use an external switch (minimum capacity 4A, 250V) to activate the pump.
6.1.5 Connecting the pump motor
Operation valid for pump with 30m (98ft) delivery.
To connect the pump use the auxiliary terminal present in the waterproof box of the pump (01).
Connect the power supply phase cable (L) and neutral cable (N).
Connect the earth cable to the pump casing (earth hole) (02).
Phase (L)Neutral (N)
6.1.6 Pump installation
Be very careful not to start the pump when the tank is empty.
6.1.6.3 Pump with 5m (16ft) or 11m (36ft)
delivery
Fill the tank with water and insert it in the metal cage. Insert the pump in the tank and tighten the cap. The system is ready to be powered.
6.1.6.4 Pump with 30m (98ft) delivery
Adjust the position of the level controller and the weight.
Instructions manual - English - EN
01
Fig. 8
Use an external switch (minimum capacity 4A, 250V) to activate the pump.
220mm
02
Fig. 9
Fill the tank with water and insert it in the metal cage, taking care to insert the male/female hydraulic coupling (01) correctly. Put the oat inside the tank and screw the plug on. Check the delivery hose coupling for the pump (02) to make sure a small quantity of water comes out.
01
Fig. 10
Connect the supply pipe. The system is ready to be powered.
120mm
02
5

7 Maintaining and cleaning

7.1 Fuses replacement

Operation valid for pump with 5m (16ft) or 11m (36ft) delivery.
If the fuse needs to be replaced the one already installed has the following characteristics:
Model Number: FUS4ATUL Brand: OMEGA Models: GT520240
EN - English - Instructions manual
Alternatively, use a T 4A L type fuse.

8 Disposal of waste materials

This symbol mark and recycle system are applied only to EU countries and not applied to the countries in the other area of the world.
Your product is designed and manufactured with high quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
Please dispose of this equipment at your local Community waste collection or Recycling centre.
In the European Union there are separate collection systems for used electrical and electronic products.

9 Technical data

WASHER PUMP AND TANK OF 5L 1.3GAL, DELIVERY HEAD 5M 16FT
Polyethylene tank, stainless steel cage Dimensions (WxHxL): 217x272x254mm Reservoir capacity: 5l (1.3gal) Delivery head: max 5m (16ft) Tube length: 5m (16ft) Power supply: IN 230Vac/120Vac/24Vac Consumption: 18W max Operating temperature: 60°C Weatherproof standard: IP56
WASHER PUMP AND TANK OF 23L 6GAL, DELIVERY HEAD 5M 16FT
Polyethylene tank, stainless steel cage Dimensions (WxHxL): 301x410x348mm
(11.8x16.1x13.7in) Reservoir capacity: 23l (6gal) Delivery head: max 5m (16ft) Tube length: 5m (16ft) Power supply: IN 230Vac/120Vac/24Vac Consumption: 18W max Operating temperature: 60°C Weatherproof standard: IP56
WASHER PUMP AND TANK OF 23L 6GAL, DELIVERY HEAD 11M 36FT
Polyethylene tank, stainless steel cage Dimensions (WxHxL): 301x410x348mm
(11.8x16.1x13.7in) Reservoir capacity: 23l (6gal) Delivery head: max 11m (36ft) Tube length: 11m (36ft) Power supply: IN 230Vac/120Vac/24Vac Consumption: 60W max Operating temperature: 60°C Weatherproof standard: IP56
WASHER PUMP AND TANK OF 23L 6GAL, DELIVERY HEAD 30M 98FT
Polyethylene tank, stainless steel cage Dimensions (WxHxL): 301x635x269mm
(11.8x25x10.6in) Reservoir capacity: 23l (6gal) Delivery head: max 30m (98ft) Tube length: 30m (98ft) Power supply: IN 230Vac/120Vac Consumption: 450W max Operating temperature: 60°C Weatherproof standard: IP45
6

10 Technical drawings

The dimensions of the drawings are in millimetres.
177
272
235
Fig. 11 Water tank 5l (1.3gal), 5m (16ft) delivery.
269
272
15074
Ø 8
217 110254
Instructions manual - English - EN
88
Ø 8
301348
200
15066
410
Fig. 12 Water tank 23l (6gal), 5m (16ft) or 11m (36ft) delivery.
152
136
7
410
635
225
Fig. 13 Water tank 23l (6gal), 30m (98ft) delivery.
301
200269
Ø 8
152136
Headquarters Italy Videotec S.p.A.
Via Friuli, 6 - I-36015 - Schio (VI) Italy Tel. +39 0445 697411 - Fax +39 0445 697414 Email: info@videotec.com
www.videotec.com
MNVKWAS_1227_EN
WAS
Pompa lavavetro e tanica da 5 o 23 litri

1 Informazioni sul presente manuale

Prima di installare e utilizzare questa unità, leggere attentamente questo manuale. Conservare questo manuale a portata di mano come riferimento futuro.
1.1 Convenzioni tipograche
PERICOLO! Pericolosità elevata. Rischio di scosse elettriche. Prima di eseguire qualsiasi operazione assicurarsi di togliere tensione al prodotto, salvo diversa indicazione.
ATTENZIONE! Pericolosità media. L'operazione è molto importante per il corretto funzionamento del sistema. Si prega di leggere attentamente la procedura indicata e di eseguirla secondo le modalità previste.
INFO Descrizione delle caratteristiche del sistema. Si consiglia di leggere attentamente per comprendere le fasi successive.

2 Note sul copyright e informazioni sui marchi commerciali

I nomi di prodotto o di aziende citati sono marchi commerciali o marchi commerciali registrati appartenenti alle rispettive società.

3 Norme di sicurezza

Il produttore declina ogni responsabilità per eventuali danni derivanti da un uso improprio delle apparecchiature menzionate in questo manuale. Si riserva inoltre il diritto di modicarne il contenuto senza preavviso. Ogni cura è stata posta nella raccolta e nella verica della documentazione contenuta in questo manuale, tuttavia il produttore non può assumersi alcuna responsabilità derivante dall'utilizzo della stessa. Lo stesso dicasi per ogni persona o società coinvolta nella creazione e nella produzione di questo manuale.
• L'installazione e la manutenzione del dispositivo deve essere eseguita solo da personale tecnico qualicato.
• Prima di eettuare interventi tecnici sull'apparecchio togliere l'alimentazione elettrica.
• Non utilizzare cavi di alimentazione con segni di usura o invecchiamento.
• Non eettuare per nessun motivo alterazioni o collegamenti non previsti in questo manuale: l'uso di apparecchi non idonei può portare a gravi pericoli per la sicurezza del personale e dell'impianto.
• Utilizzare solo parti di ricambio originali. Pezzi di ricambio non originali potrebbero causare incendi, scariche elettriche o altri pericoli.
• Prima di procedere con l'installazione controllare che il materiale fornito corrisponda alle speciche richieste esaminando le etichette di marcatura (4.2 Marcatura del prodotto, pagina 2).