Before installing and using this unit, please read this
manual carefully. Be sure to keep it handy for later
reference.
1.1 Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the
power supply before proceeding with any
operation, unless indicated otherwise.
WARNING!
Medium level hazard.
This operation is very important for the
system to function properly. Please read
the procedure described very carefully and
carry it out as instructed.
INFO
Description of system specications.
We recommend reading this part carefully
in order to understand the subsequent
stages.
2 Notes on copyright and
information on trademarks
The quoted names of products or companies are
trademarks or registered trademarks.
3 Safety rules
The manufacturer declines all responsibility
for any damage caused by an improper use
of the appliances mentioned in this manual.
Furthermore, the manufacturer reserves
the right to modify its contents without any
prior notice. The documentation contained
in this manual has been collected with great
care, the manufacturer, however, cannot
take any liability for its use. The same thing
can be said for any person or company
involved in the creation and production of
this manual.
• The device must be installed only and exclusively
by qualied technical personnel.
• Before any technical work on the appliance,
disconnect the power supply.
• Do not use power supply cables that seem worn
or old.
• Never, under any circumstances, make any
changes or connections that are not shown in
this handbook: improper use of the appliance
can cause serious hazards, risking the safety of
personnel and of the installation.
• Use only original spare parts. Non-original spare
parts could cause re, electrical discharge or other
hazards.
• Before proceeding with installation check the
supplied material to make sure it corresponds
to the order specication by examining the
identication labels (4.2 Product markings, page 2).
4 Identification
4.1 Product description and type
designation
5l (1.3gal) o 23l (6gal) tank. Dierent pumps are
available for delivery up to 5m (16ft), 11m (36ft) or
30m (98ft). Available voltages in 230Vac, 24Vac or
120Vac. Pumps with 30m (98ft) delivery are available
only in 230Vac or 120Vac.
In the 30m (98ft) delivery version the lack of liquid in
the tank is signalled following the automatic stop of
the pump.
EN - English - Instructions manual
4.2 Product markings
See the label attached to the outside of the package.
5 Preparing the product for
use
Any change that is not expressly approved
by the manufacturer will invalidate the
guarantee.
5.1 Safety precautions before use
In the 115/230Vac powered conguration
it is necessary to insert a 1 0 unipolar main
switch (open contact distance d>3mm).
This switch should be used to disconnect
the power supply before carrying out any
maintenance operation or before opening
the procuct.
5.2 Unpacking and contents
5.2.1 Unpacking
When the product is delivered, make sure that the
package is intact and that there are no signs that it
has been dropped or scratched.
If there are obvious signs of damage, contact the
supplier immediately.
Keep the packaging in case you need to send the
product for repairs.
5.2.2 Contents
Check the contents to make sure they correspond
with the list of materials as below:
• Washer kit
• Clamp
• Silicon sheath
• Washer pipe
• Instructions manual
5.3 Safely disposing of packaging
material
The packaging material can all be recycled. The
installer technician will be responsible for separating
the material for disposal, and in any case for
compliance with the legislation in force where the
device is to be used.
When returning a faulty product we recommend
using the original packaging for shipping.
6 Assembling and installing
Only specialised personnel should be
allowed to assemble and install the device.
Before starting any operation, make sure
the power supply is disconnected.
2
6.1 Installation
6.1.1 Installing the pump tank
If using the pump at temperatures below
3°C (37.4°F) add some antifreeze liquid to
the water.
The antifreeze liquid will cause irreparable
damage to the germanium glasses. For
pan & tilts tted with germanium glasses,
do not use antifreeze liquid but add ethyl
alcohol in 20% solution.
Attach the metal cage (01) rmly to a wall using the
holes provided for this (02).
01
02
Fig.1Water tank 5l (1.3gal), 5m (16ft) delivery.
Instructions manual - English - EN
01
02
Fig.3Water tank 23l (6gal), 30m (98ft) delivery.
Take the plug out of the tank, along with any pumps
and level gauges. Remove the tank from the metal
cage.
6.1.2 Choose the power supply line
Depending on the version, the device can be
provided with dierent power supply voltages. Their
value is shown on the product identication label.
Always make the electrical connections
with the power supply disconnected and
the circuit-breaker open.
01
02
Fig. 2 Water tank 23l (6gal), 5m (16ft) or 11m (36ft) delivery.
When commencing installation make sure
that the specications for the power supply
for the installation correspond with those
required by the device.
Make sure that the power source and
connecting cables are suitable for the
power consumption of the system.
3
6.1.3 Open the box
Operation valid for pump with 5m (16ft) or
11m (36ft) delivery.
Open the cover of the water-proof box and connect
as described below.
6.1.4.1 Installing the fuse
Move the fuse into the correct fuse holder
according to the input voltage.
230V
120V
24V
EN - English - Instructions manual
Fig. 4
6.1.4 Connection of the board
Operation valid for pump with 5m (16ft) or
11m (36ft) delivery.
Find the position of the following on the pump
control board: fuses (01), power supply terminal
J5(02) and pump connector J3(03).
FUS1
Fig. 6
FUS2
FUS3
The pump is supplied with the fuse in position FUS1
(for a 230Vac power supply).
If the power supply is dierent position the fuse
correctly referring to the following table.
INSTALLING THE FUSE
VoltageFuse holder
230VacFuse in FUS1
120VacFuse in FUS2
24VacFuse in FUS3
Tab. 1
6.1.4.2 Connection of the power supply line
The power supply cable should also be
covered by the silicone sheath (01) supplied
for this purpose, and fastened with the
corresponding tie (02).
01
02
01
Neutral (N)
Phase (L)
Fig.5
4
02
Fig.7
Connect the power supply terminal J5 (02) to the
electric network using a suitably sectioned cable
(minimum 1.5mm²) (Fig. 5, page4).
Use an external switch (minimum capacity
4A, 250V) to activate the pump.
6.1.5 Connecting the pump motor
Operation valid for pump with 30m (98ft)
delivery.
To connect the pump use the auxiliary terminal
present in the waterproof box of the pump (01).
Connect the power supply phase cable (L) and
neutral cable (N).
Connect the earth cable to the pump casing (earth
hole) (02).
Phase (L)Neutral (N)
6.1.6 Pump installation
Be very careful not to start the pump when
the tank is empty.
6.1.6.3 Pump with 5m (16ft) or 11m (36ft)
delivery
Fill the tank with water and insert it in the metal cage.
Insert the pump in the tank and tighten the cap.
The system is ready to be powered.
6.1.6.4 Pump with 30m (98ft) delivery
Adjust the position of the level controller and the
weight.
Instructions manual - English - EN
01
Fig. 8
Use an external switch (minimum capacity
4A, 250V) to activate the pump.
220mm
02
Fig.9
Fill the tank with water and insert it in the metal
cage, taking care to insert the male/female hydraulic
coupling (01) correctly. Put the oat inside the tank
and screw the plug on. Check the delivery hose
coupling for the pump (02) to make sure a small
quantity of water comes out.
01
Fig.10
Connect the supply pipe.
The system is ready to be powered.
120mm
02
5
7 Maintaining and cleaning
7.1 Fuses replacement
Operation valid for pump with 5m (16ft) or
11m (36ft) delivery.
If the fuse needs to be replaced the one already
installed has the following characteristics:
Model Number: FUS4ATUL
Brand: OMEGA
Models: GT520240
EN - English - Instructions manual
Alternatively, use a T 4A L type fuse.
8 Disposal of waste
materials
This symbol mark and recycle system
are applied only to EU countries and not
applied to the countries in the other area of
the world.
Your product is designed and manufactured with
high quality materials and components which can be
recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed of
separately from your household waste.
Please dispose of this equipment at your local
Community waste collection or Recycling centre.
In the European Union there are separate collection
systems for used electrical and electronic products.
9 Technical data
WASHER PUMP AND TANK OF 5L 1.3GAL,
DELIVERY HEAD 5M 16FT
Polyethylene tank, stainless steel cage
Dimensions (WxHxL): 217x272x254mm
Reservoir capacity: 5l (1.3gal)
Delivery head: max 5m (16ft)
Tube length: 5m (16ft)
Power supply: IN 230Vac/120Vac/24Vac
Consumption: 18W max
Operating temperature: 60°C
Weatherproof standard: IP56
WASHER PUMP AND TANK OF 23L 6GAL,
DELIVERY HEAD 5M 16FT
Prima di installare e utilizzare questa unità, leggere
attentamente questo manuale. Conservare questo
manuale a portata di mano come riferimento futuro.
1.1 Convenzioni tipograche
PERICOLO!
Pericolosità elevata.
Rischio di scosse elettriche. Prima di
eseguire qualsiasi operazione assicurarsi di
togliere tensione al prodotto, salvo diversa
indicazione.
ATTENZIONE!
Pericolosità media.
L'operazione è molto importante per il
corretto funzionamento del sistema. Si
prega di leggere attentamente la procedura
indicata e di eseguirla secondo le modalità
previste.
INFO
Descrizione delle caratteristiche del
sistema.
Si consiglia di leggere attentamente per
comprendere le fasi successive.
2 Note sul copyright e
informazioni sui marchi
commerciali
I nomi di prodotto o di aziende citati sono marchi
commerciali o marchi commerciali registrati
appartenenti alle rispettive società.
3 Norme di sicurezza
Il produttore declina ogni responsabilità
per eventuali danni derivanti da un
uso improprio delle apparecchiature
menzionate in questo manuale. Si
riserva inoltre il diritto di modicarne il
contenuto senza preavviso. Ogni cura è
stata posta nella raccolta e nella verica
della documentazione contenuta in questo
manuale, tuttavia il produttore non può
assumersi alcuna responsabilità derivante
dall'utilizzo della stessa. Lo stesso dicasi
per ogni persona o società coinvolta nella
creazione e nella produzione di questo
manuale.
• L'installazione e la manutenzione del dispositivo
deve essere eseguita solo da personale tecnico
qualicato.
• Prima di eettuare interventi tecnici
sull'apparecchio togliere l'alimentazione elettrica.
• Non utilizzare cavi di alimentazione con segni di
usura o invecchiamento.
• Non eettuare per nessun motivo alterazioni o
collegamenti non previsti in questo manuale:
l'uso di apparecchi non idonei può portare a
gravi pericoli per la sicurezza del personale e
dell'impianto.
• Utilizzare solo parti di ricambio originali. Pezzi di
ricambio non originali potrebbero causare incendi,
scariche elettriche o altri pericoli.
• Prima di procedere con l'installazione controllare
che il materiale fornito corrisponda alle speciche
richieste esaminando le etichette di marcatura (4.2
Marcatura del prodotto, pagina 2).
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.