Made by RSI VIDEO T ECHNOLOGIES
IMV Indoor Motion Viewer - Install sheet Ed05EN
1/5
Product Summary
The MotionViewer IMV is a wireless, indoor motion activated camera
designed for use in a Videofied™ security system. The camera
includes the following features:
Lithium batteries for long life
Color day / B&W night
Wide angle lens
Infrared LEDs for night illumination
Standard motion coverage lens (30 ft./9 m distance)
Dual tamper function provides detection of both wall and cover
tamper.
Transmits check-in/status signal every 8 minutes
Installation Guidelines
For easier installation, programming and RF testing should be done to
check for good communication between the control panel and all
system devices before mounting.
Install the detector and other system devices in the following order:
Programming / RF Testing: program detector and all other devices
into the control panel and test RF communication at each
intended device location to the control panel.
Mounting: mount detector at the tested location.
Mounting rules
Use proper tools and hardware.
Mount indoors in a temperature controlled environment.
Mount camera 2.1 to 2.3 m (6.9 to 7.5 ft.) from the floor.
Respect Top and Bottom side of the Motion Viewer
When possible, mount in a wall corner in order to aim at a complete room
Mount detector on an outside wall, aimed at area to protect.
Do not aim detector at windows, especially those that let in direct sunlight, or at heat sources such as lamps, fireplaces,
radiators, and heating vents.
Do not aim detector at moving objects such as curtains, fans or animals.
Do not cover the Fresnel lens
Corner Mounting
Use only 2x screws on the same side (left or right) to mount the casing on the
corner
IMV Indoor Motion Viewer - Install sheet Ed05EN
2/5
Programming / RF testing / Mounting
The following provides summarized steps for device
programming, testing and mounting. For complete details,
refer to the control panel installation manual.
1
1
Loosen bottom screw ① (if present),
separate base from IMV ②.
2
2
Install 2 SAFT LS14500 3.6V lithium batteries, observing
correct polarity.
Check that LED flashes before staying red.
3
3
Put control panel into programming/configuration mode.
4
4
Using a programmed alphanumeric keypad, proceed
through menus until the display shows ADD A NEW
DEVICE.
5
5
Press Yes. The display shows PRESS PROGRAM BUTTON
OF DEVICE.
6
6
Press and release program button on IMV using
your finger or a screw driver ①.
The IMV LED flashes red ②.
Wait for keypad display to show CAMERA (1 - 24)
PROGRAMMED.
7
7
Press Yes. The display shows RADIO RANGE TEST?
Press Yes again. The IMV LED starts flashing and keypad
display shows TEST IN PROGRESS.
8
8
Move the IMV to the intended mounting location and
make sure you receive a 5/5 or 9/9 indicating good
communication with the control panel.
9
9
Press YES to end radio range test, then press Esc/No.
110
0
The display shows AREA ALLOCATION AREA: 1. Press
either arrow button repeatedly until desired AREA
number appears, then press Yes. By default all devices in
area 1 will be subject to the entry and exit delays.
111
1
The display shows NAME + LOCATION.
Enter appropriate device name (up to 16 characters). The
name of the device should describe its intended
mounting location or zone. Then press Yes. The display
will show the device number and name for your
verification.
112
2
Mount the IMV on the wall:
- Follow the mounting rules on page 1
- Hold the IMV base against the mounting surface and
mark the appropriate mounting holes.
- Drill pilot holes and install anchors where needed.
- Place base on mounting surface so that the pilot line
up and secure base with appropriate screws.
- Attach camera to base and secure with screw if
required.
113
3
Press Yes. The display shows FUNCTIONAL DEVICE TEST?
Press Yes again and verify IMV operation. For example,
wave your hand in front of the sensor to activate the LED
which indicates detection.
114
4
Press Yes to end detection verification.
115
5
The display shows ADD A NEW DEVICE? Repeat steps 1 –
14 for remaining MotionViewers.
116
6
When finished, exit from configuration mode by pressing
and holding the ESC/NO for 5 seconds..