Videofied DCV601 Installation Sheet

Indoor MotionViewer DCV601
PRODUCT INSTALLATION SHEET
Made by RSI VIDEO TECHNOLOGIES 2220-IMVIS March 2012
Product Summary
The Indoor MotionViewer DCV601 is a wireless, indoor motion activated camera designed for use with Videofied security systems. The camera includes the fol­lowing features:
Lithium batteries for long life.
>
>
Infrared LED for night illumination.
>
Standard motion coverage lens (30 ft./9 m distance).
>
Dual tamper function provides detection of both
>
wall and cover tamper.
Transmits check-in/status signal every 8 minutes.
>
Programming/RF Testing
The following provides summarized steps for device programming and testing. For complete details, refer to the control panel installation manual.
1
Loosen bottom screw, separate base
from camera and install batteries.
2
Re-attach base to secure
tamper switch.
3
Put control panel into
programming/configuration mode.
4
Using a programmed alphanumeric keypad, proceed through menus until the display shows ADD A NEW DEVICE.
5
Press Yes . The display shows PRESS PROGRAM BUTTON OF DEVICE.
6
Press and release program button on camera using a paper clip end. The camera LED flashes. Wait for keypad display to show CAMERA (1 - 25) PROGRAMMED.
7
Press Yes . The display shows RADIO RANGE TEST? Press Yes again. The camera LED starts flashing and keypad display shows TEST IN PROGRESS.
Screw
Program Button
Installation Guidelines
For easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting system devices.
Install the detector and other system devices in the order of the following steps:
Programming/RF Testing - program detector and all other
>
devices into the control panel and test RF communication from each intended device location to the control panel.
Mounting - mount detector at the tested location.
>
8
Take camera to its intended mounting location and make sure LED flashes continuously or you receive a 5/5 or 9/9 indicating good communication with the control panel.
9
Press YES to end radio range test, then press Esc/No.
10
The display shows AREA ALLOCATION AREA: 1. Press either arrow button repeatedly until desired AREA number appears, then press Yes .
11
The display shows NAME + LOCATION. Enter appropriate device name/location (up to 16 characters), then press Yes . The display shows the device number and name for your verification.
12
Press Yes . The display shows FUNCTIONAL DEVICE TEST? Press Ye s again and verify camera operation. For example, wave your hand in front of the sensor to activate its LED indicating detection. (walk test LED)
13
Press Yes to end detection verification.
14
The display shows ADD A NEW DEVICE? Repeat steps 1 – 14 for remaining cameras.
15
When finished, exit from configuration mode.
www.videofied.com
Indoor MotionViewer DCV601
INSTALLATION DATA SHEET
WARNING : Do not cover the Fresnel lens !
Mounting
Use proper tools and hardware.
>
Mount indoors in a temperature-controlled environment.
>
Mount camera 2.1 to 2.3 m (6.9 to 7.5 ft.) from the floor.
>
Mount detector on an outside wall, aimed at area to protect.
>
Do not aim detector at windows, especially those that
>
let in direct sunlight, or at heat sources such as lamps, fireplaces, radiators, and heating vents.
Do not aim detector at moving objects such as curtains,
>
fans or animals.
1
Separate base from camera.
2
Hold camera base against mounting surface and mark the two appropriate mounting holes.
3
Drill pilot holes and install anchors where needed.
4
Place base on mounting surface so holes line up with pilot holes/anchors and secure base with appropriate screws.
5
Install batteries into camera, observing correct polarity.
6
Attach camera to base and secure with screw.
Flat Wall Mounting Holes
Corner Mounting Holes
www.videofied.com
Indoor MotionViewer DCV601
INSTALLATION DATA SHEET
Electrical Data
Panel Compatibility Xl, Visio, XT, XTIP
Power requirements Three 3.6 V Lithium batteries
Nominal Voltage 3V
Low Battery Limit 2.7V
Battery type SAFT AA Lithium, LS14500
Battery life (estimated) Up to 4 years
RF technology S2View
Radio type Spread Spectrum Bidirectional RF
Operating frequency 915 MHz (US) Transmission security AES algorithm encryption
Supervision Panel polls devices every 8 minutes
Antenna Integrated
Tamper detection Wall and cover tampered
Camera sensor type CMOS black and white
Camera resolution 320 x 240 pixels
Camera sensitivity 0.2 lux
Camera lens Wide angle 85°
Camera response less than 100 milliseconds after PIR detection
Video sequence in intrusion 5 frames/s for 10 seconds
Night illumination 2 infrared LEDs
Night illumination switching Automatic
Night illumination distance UP to 14 ft./ 4.5 m
Motion detector technology Passive infrared DSP
Motion detector type Dual element
Motion Lens Fresnel
Motion Detection angle 85°
Motion Detection distance Up to 40 ft./12 m
Motion Detection pattern 24 facets
Operating temperature 14° - 104° F (-10° - 40° C)
Maximum relative humidity 75%, non-condensing
UL Listings FCC Part 15C
1023 (applied for)
®
Physical Data
Material ABS—ULV0
Dimensions (LxWxD): 3-1/2 in. x 2-3/4 in. x 2-3/4 in.
(89 mm x 70 mm x 70 mm)
Weight 5.3 oz./150 g (without batteries)
Installation/Mounting
Camera/Base One screw secures camera to base; two screws secure camera base to mounting surface, flat or corner mount.
Mounting Height 6.9-7.5 Feet (2.1-2.3 meters)
www.videofied.com
Indoor MotionViewer DCV601
PRODUCT INSTALLATION SHEET
FCC Regulatory Information for USA and CANADA
FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment.
FCC Part 15.105 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
EMEA SALES
23, avenue du G énéral Leclerc 92340 BOURG-LA-REINE FRANCE Hotline: +33 (0)820 8 46 620 Fax: +33 (0)1 82 69 80 10
USA SALES
4455 White B ear Parkway, Suite 700 White Bea r Lake, MN 55110 USA Hotline: +1 877 206 58 00 Fax: +1 651 762 4693
www.videofied.com
© 2011 RSI VIDEO TECHNOLOGI ES. VIDEOFIED® is a Registere d Trademark of RSI VID EO TECHNOLOGIES .
S2View® is a registere d trademark of RSI V IDEO TECHNOLOGI ES. Specicat ions subject to ch ange without not ice.
Loading...