Ultra-fast Maximum Power Point Tracking (MPPT)
Advanced Maximum Power Point Detection in case of partial shading conditions
Outstanding conversion efficiency
Flexible charge algorithm
Extensive electronic protection
Internal temperature sensor and optional external battery voltage and temperature sensing
via Bluetooth
VE.Can: the multiple controller solution
Optional: SmartSolar pluggable LCD display
SmartSolar Charge Controllers
SmartSolar Charge Controller
MPPT 150/100-Tr VE.Can
with optional pluggable display
SmartSolar Charge Controller
MPPT 150/100-Tr VE.Can
without display
Bluetooth sensing:
Smart Battery Sense
Bluetooth sensing:
BMV-712 Smart Battery Monitor
SmartSolar pluggable display
MPPT 150/70 VE.Can up to MPPT 150/100 VE.Can
with VE.Can interface
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast
MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers
and by up to 10% compared to slower MPPT controllers.
If partial shading occurs, two or more maximum power points (MPP) may be present on the
power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative SmartSolar algorithm will always maximize energy harvest by locking to the
optimum MPP.
No cooling fan. Maximum efficiency exceeds 98%.
Fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a
rotary switch (see manual for details).
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery
voltage and temperature to one or more SmartSolar Charge Controllers.
Up to 25 units can be synchronised with VE.Can
For a wired data connection to a Color Control GX, other GX products, PC or other devices
To connect for example to a VE.BUS BMS.
Can be programmed to trip on an alarm,
or other events.
Simply remove the rubber seal that protects
the plug on the front of the controller,
and plug-in the display.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
SmartSolar Charge Controller
with VE.Can interface
12/24/48V Auto Select (36V: manual)
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Nominal PV power, 36V 1a,b)
Nominal PV power, 48V 1a,b)
Max. PV short circuit current 2)
50A (max 30A per MC4 conn.)
70A (max 30A per MC4 conn.)
Maximum PV open circuit voltage
150V absolute maximum coldest conditions
145V start-up and operating maximum
Less than 35mA @ 12V / 20mA @ 48V
Default setting: 14,4 / 28,8 / 43,2 / 57,6V
(adjustable with: rotary switch, display, VE.Direct or Bluetooth)
Default setting: 13,8 / 27,6 / 41,4 / 55,2V
(adjustable: rotary switch, display, VE.Direct or Bluetooth)
Charge voltage 'equalization'
Default setting: 16,2V / 32,4V / 48,6V / 64,8V (adjustable)
multi-stage adaptive (eight preprogrammed algorithms) or user defined algorithm
-16 mV / -32 mV / -64 mV / °C
Battery reverse polarity (fuse, not user accessible)
PV reverse polarity / Output short circuit / Over temperature
-30 to +60°C (full rated output up to 40°C)
5000m (full rated output up to 2000m)
VE.Can, VE.Direct and Bluetooth
DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to 60VDC
Yes, parallel synchronised operation with VE.Can
35 mm² / AWG2 (Tr models)
IP43 (electronic components), IP22 (connection area)
Tr models: 185 x 250 x 95 mm
MC4 models: 215 x 250 x 95 mm
Tr models: 216 x 295 x 103
MC4 models: 246 x 295 x 103
EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
Maximum current per MC4 connector: 30A (the MC4 connectors are parallel connected to one MPPT tracker)
With VE.Can up to 25 Charge Controllers can be daisy-chained and connected to a Color Control GX or other GX device
Each Controller can be monitored individually, for example on a Color Control GX and on the VRM website
Charge voltage 'absorption'
Charge voltage 'float'
Protection
150/70 150/85 150/100
PV terminals 3)
Two pairs of MC4 connectors (MC4
35 mm² / AWG2 (Tr models)
Three pairs of MC4 connectors (MC4 models)
Dimensions (h x w x d) in mm
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com