Victron energy Blue Power BMV-602 Instruction Manual

Page 1
1
Instructions for the Victron Energy MONITORING PANEL with
DIGITAL MULTI CONTROL PANEL (DMC) and
BATTERY MONITOR BMV-602
This publication or parts thereof, may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission to use this manual for publication in other than the English language, conctat Victron Energy B.V.
Victron Energy B.V. reserves the right to revise and improve its products as it sees fit. This publication describes the state of this product at time of its publication and may not reflect at all times in the future.
Introduction
The MONITORING PANEL with integratet Digital Multi Control Panel and Battery Monitor BMV - 602 is a device that:
Monitors your battery status (battery voltage and current) and calculate the actual state of charge of your battery
Monitors and signals AC voltage of three sources (shore, generator and inverter)
Monitors inverter current to the AC consumer
is a remote panel designed to work with all Multis/Quatro¨s and Multi/Quatro systems.
Operation
Installation
WARNING! Be sure that all AC power sources are switched off or disconnected during installation.
Install the MONITORING PANEL in a dry, well ventilated area. The front of the panel is attached using the four supplied screws. The MONITORING PANEL may be mounted in the wall, using the four holes in the front of the panel.
The input cables from the shore, generator, inverter, digital multi control and battery monitor should be connected according to the the wiring diagram (see figure 1). The correct wire cross section must be applied for a safe installation. Under sized cables can cause overheating of the cables.
Tighten all connections well in order to limit transition resistance as far as possible. Loose connections can cause dangerous overheating of the teminals.
Adjustement of the MONITORING PANEL ist not recommended. After correct instalation the MONITORING PANEL is ready for use.
Page 2
2
The wiring to the AC-inputs and outputs must be protected by fuses or miniature circuits breaker which are suitable for the applied wire cross section. External earth leakage switches( RCD, RCCB) must also be integrated in the wiring
All ground connections of the power sources and power consumers must be connected to the central ground connection of the ship
To connect Digital Multi control panel see user and installation manual
To connect Battery monitor BMV-602 see user and installation manual
Transport and storage
When storing or transporting the product , make certain that mains power and battery leads are disconnected
No liability can be accepted for any transport damage when equipment is shipped in non-original packaging
Store the product in a dry location, storage temperature must be between - 20
°°°°
C and
+ 60
°°°°
C.
Page 3
3
Specifications
VE
MONITORING PANEL
Nominal voltage
200
- 250 V AC
, Single phase
Nominal frequency
50 –
60 Hz
Input 1, Shore voltage
200
- 250 V, AC
Input 2, Generator voltage
200
- 250 V, AC
Input 3, Inverter output voltage
200
- 250 V AC
Current transformer (CT)
50/5 A,
2 VA
Power supply
12 V, DC
GENERAL Operating temperature
-5
°°°°
C to + 60
°°°°
C
Humidity (non condensing)
Max. 95 %
Miniatur circuit breaker (MCB)
Not included
installation dependent
Earth leakage breakers (RCD)
Not included
– installation dependent
ENCLOSURE Protection category
IP 20
Color
RAL 7035
Dimension h x w x d (mm)
213 x
150 x 75
Weight (kg)
0,985
Contents:
- Monitoring panel 1 piece
- Power supply cable, 1,2 m 1 piece
- Current transformer 50/5 A 1 piece
- CT cable, 10 m 1 piece
- Input 1,2, 3, cable, 1,2 m 1 piece
Page 4
4
Electrical and installation diagrams, outline drawings
Page 5
5
MONITORING PANEL wiring with MULTI PLUS
Page 6
6
MONITORING PANEL wiring with QUATTRO
Page 7
7