Victory-Raetone VBC-480 User Manual

Remote Roll-In Blast Chiller Extra Wide Combi Size
Large foodservice operations benefit from chilling capacity of 480 and 660 lbs of food product to +38°F in about 90 minutes.
Refrigeration System
Cabinets require single remote condensing unit or equivalent to support operation. A remote indoor/outdoor condensing unit is available from the factory or third party suppliers. Consult price list for selections.
The self-contained top mounted refrigeration system allows for use as a +38°F storage refrigerator. Expansion and solenoid valves standard. An external drain is required near the back of the cabinet for the defrost water.
Controls
Unique E-Z Blast™ 1-2-3 microprocessor control panel initiates blast cycles in three simple steps. Model features built-in alarms and can control the chilling process with the temperature probes or a digital timer, which can be programmed with two preset chilling times for specific food products. The controller supports a la carte style blast chilling.
HACCP Data Logger System records, stores and prints temperature data for up to 7 days in accordance with HACCP guidelines. Its
built-in thermal printer provides simplified documentation and HACCP record keeping.
May be used with optional NAFEM Data Protocol compliant documentation software for HACCP monitoring to transfer data from kitchen to a remote Windows® compatible computer system. Program is available from the factory and many third-party suppliers.
Cabinet
Exterior is heavy gauge stainless steel front, back, sides and door. Galvanized steel top. Interior is heavy gauge stainless steel with radius corners. 3
1
/
2”of environmentally
friendly ODP Zero Polyurethane foam injected insulation throughout the cabinet ensures the ultimate in energy efficiency.
Doors
Door is hinged right and cannot be site reversed. Standard with flush recessed handle, hydraulic closer, magnetic gasket, heater and self-closing hinges with a 90° “stay open” feature.
Construction
Roll-in Blast Chillers are made from walk-in type cam-lock panels and are delivered knocked down for ease of installation. Panel assembly is required on site.
VBC MODELS —
VBC-480 VBC-660
Victory Refrigeration, Inc. I 110 Woodcrest Road I Cherry Hill, NJ 08003 USA I Phone: 856.428.4200 I Fax: 856.428.7299 I E-mail: sales@victory-refrig.com
Victory Refrigeration specification sheets
are available online at
www.victoryrefrigeration.com.
Approvals:
Project:
Location:
Item #:
Quantity:
Roll-In Rack
Stainless steel removable rack guides protect wall panels from damage. Optional racks are available from the factory. Maximum rack size is 34
1
/2” wide x 40” deep x 77” high exterior
dimensions including casters.
Model shown with optional insulated floor and ramp.
Standard Features
• Two Operational Functions:
- Blast Chill Processing Refrigerator
- +38°F Storage Refrigerator
• E-Z Blast™ Microprocessor Control Panel:
- Blast Chill Cycle Controlled Automatically by Either a Food Probe or Digital Timer
•Two (2) Preset Chill Times: 90, 240 Minutes
•Soft Chill and Hard Chill Options
•Three (3) Food Probes with Digital Temperature Indication
- Cabinet Temperature Digital Display
- Food Temperature Digital Display
- Defrost Mode Indicator
- On/Off, Blast Chill Cycle and Cancel Buttons
- Diagnostic Trouble Shooting Capability
• High and Low Temperature Alarm
• Power and Component Failure Alarms
• HACCP Data Logger System Records, Stores and Prints Temperature Data up to 7 Days
- After Termination of Chill Mode
- After Cancellation of Chill Mode
- Daily at Midnight
- Seven (7) Day History on Demand
- Built-In Thermal Printer
• Compartment Accepts Two (2) Roll-in Carts 34
1
/2” Wide x 40” Deep x 77” High
• Complies with FDA, NSF 7 and HACCP Guidelines
• Defrost on Demand or Automatic Defrost
• Environmentally Friendly R-134a Refrigerant
• 3”of Environmentally Friendly ODP Zero Polyurethane Foam Injected Insulation
Optional Features and Accessories
• Reverse Door Hinging
• Roll-thru (Specify Door Hinging)
• Indoor/Outdoor Condensing Units
• Insulated Floors (Adds 3
1
/2” to Height)
• Stainless Steel Floor Ramps
• Stainless Steel Roll-In Rack (Single Section)
• HACCP Monitoring
• Extra Printer Paper
Blast CChill/Storage RRefrigerator
VBC-6660
Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice.
Victory RRefrigeration, IInc. Remote RRoll-IIn BBlast CChiller
CHARACTERISTICS VBC-480 VBC-660
Capacity (lbs./90 mins.) 480 lbs 660 lbs Width, Overall 57.95” 57.95” Depth, Overall 92.7” 92.7” Depth, Door Open 90º 120.25” 120.25” Height with Floor 101.7” 101.7” Height without Floor 98.2” 98.2” Clear Door Width 27.5” 27.5” Clear Door Height 73.8” 73.8” No. of Carts (Optional) 2 2 Cabinet Voltage 208-230/60/3 208-230/60/3 Feed Wires (with Ground) 3 3 Total Amperes 20 20
Note: The self-contained refrigeration system is top mounted for the storage cycle only. This avoids short cycling of the stand alone condensing unit when in the +38°F storage mode. All roll-in models require remote refrigeration.
Crated DDimensions aand WWeights
Height WWidth DDepth WWeight
VBC-480 72” 90.5” 59” 1158 lbs
VBC-660 72” 90.5” 59” 1158 lbs
†Shipped on 2 skids, each of this weight. Add 110 lbs per roll-in rack ordered.
Storage RRefrigeration DData
Refrigerant CCompressor BBTUH* VBC-480 R-134a .75 H.P. 4759 VBC-660 R-134a .75 H.P. 4759
*BTUH @ 100oF. Ambient, +25oF. Evaporator
Remote BBlast CChilling RRefrigeration DData
RReeffrriiggeerraanntt LLiiqquuiidd LLiinnee SSuuccttiioonn LLiinnee BBTTUU//HH**
SSiizzee SSiizzee
VBC-480 R-404a .5 (X2) 1.125 (X2) 60,000 VBC-660 R-404a .5 (X2) 1.125 (X2) 72,000
*BTUH @ 90oF. Ambient, +5oF. Evaporator
Dimensional tolerance ± .25” Metric dimensions (mm)
Top View
Front View Without Insulated Floor
Printed in U.S.A. ©October 2007
VBC480SS/1007/US
NOTE:
If cabinet is located directly against wall and/or under low ceiling, a minimum clearance of 12” is required.
Insulated floor adds 3.5” in height.
We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding replacements for previously purchased equipment.