PASS-THRU DUAL
TEMPERATURE
REFRIGERATORS/
FREEZERS
FEATURING:
Long Door
RFS-2D-S1-PT
RFSA-2D-S1-PT
Half Door
RFS-2D-S1-PT-HD
RFSA-2D-S1-PT-HD
Secure-Temp 1.0™ is the industry’s first and only full
service temperature monitoring solution for your kitchen.
Secure-Temp 1.0™ is standard on all Victory models and is
HACCP compliant & meets NAFEM’s data protocol.
There are NO software or monthly monitoring fees.
- Equipped with Secure-Temp 1.0™ Technology™
- 3 Year Parts & Labor Warranty Plus an Additional
2 Year Compressor Warranty
- Exclusive 2 Year Warranty on Santoprene Door Gaskets
Optional add on kits are available for additional units.
STANDARD FEATURES
V-TEMP™ Electronic Control System
LED Lighting with Proximity Door Switch, Activates Interior Lighting
Expansion Valve Technology
20 Gauge, Stainless Steel Doors
Dual Speed, Energy Efficient, EC Fan Motors
Santoprene Door Gaskets with Exclusive 2 Year Warranty
Stainless Steel Breakers
High Performance, Balanced, Top-Mounted Refrigeration
R-134a and R-404A Refrigerants
Plasticized Evaporator Fin Coils
Non-Electric Condensate Evaporator
Foamed-in-Place Polyurethane Insulation
Insulated Partition Wall Separates Compartments
Heavy Duty Cylinder Locks
Self-Closing Doors with 120
Cam-Lift Hinges, Guaranteed for Life
Ergonomically Correct Door Handles, Guaranteed for Life
S, SA Series have 6” High, Adjustable Stainless Steel Legs
Hinged Front Shroud Makes Condenser Cleaning Easier
One Piece, Snap-In Magnetic Door Gasket(s)
Anti-Condensate Door Perimeter Heaters
Stainless Steel Interior Door Liner
Energy Saving Thermal Breaker Caps, Guaranteed for Life
Three (3) Epoxy Coated Wire Shelves per Cabinet Section
Cord and Plug (see electrical data for details)
°
Hold Open Feature
RFS-2D-S1-PT
OPTIONS & ACCESSORIES
Full and Half-Size Glass Doors
Remote Models
Correctional Facilities Options
Stainless Steel Shelves
6” Overall Height Casters (set of 4)
Exterior Laminate Décor
Adjustable Tray and Pan Slides
Optional Voltages
FLEXTEMP Performance Mode (Refrigerator only)
3779 Champion Blvd—Winston-Salem, NC 27105
PH: (888) 845-9800 - Fax: (800) 253-5168
sales@victoryrefrigeration.com www.victoryrefrigeration.com
FEATURING:
CABINET CONSTRUCTION
The cabinet front and doors are constructed of heavy gauge, polished stainless steel
to maintain an attractive appearance after years of heavy use. Polyurethane foam
insulation throughout ensures the ultimate in energy efficiency. The front shroud lifts
up for easy access when cleaning the condenser unit.
DOOR CONSTRUCTION
The doors are heavy gauge, polished stainless steel with a stainless steel interior
liner. Each door is provided with a cylinder lock and ergonomically correct vertical
handle. The door hinges are self-closing and have a hold-open feature at 120° which
facilitates product loading. Proximity switches energize the recessed interior incandescent lighting when the door is opened. Humidity control wires around the door
jamb prevent condensation from forming on the front of the cabinet in high humidity
environments. The wires are concealed by a high impact, non-conducting thermal
breaker cap.
REFRIGERATION SYSTEM
High efficiency, air-cooled, self-contained refrigeration systems are provided. The
evap-orator coils for both compartments are ceiling mounted on the single section
model. The two section model has a top mounted system with the evaporator coils
located outside the food storage zone. Environmentally friendly R-134A for the refrig-
erator and R-404A for the freezer are efficiently metered by capillary systems providing a constant, safe operating temperature and quick “recovery” under the most
demanding conditions. The hermetically sealed systems are designed to operate at
38°F and 0°F. Each cooling coil has plasticized fin coils to resist food acids and dualspeed EC fan motor(s) for greater cooling capacity and efficiency. All condensate
water is disposed of automati-cally by the condensate vaporizer on the single section
and disposed of automatically with the non-electric hot gas disposal system on the
two section model.
INTERIOR STORAGE ARRANGEMENTS
Shelves are adjustable in one inch increments. A wide door opening allows for the
use of a variety of optional pan slide configurations including 18” x 26” and 12” x 20”
pans.
V-TEMP™ CONTROL SYSTEM
The easy to use V-TEMP™ Control is standard. This durable, water resistant microprocessor monitors and controls the entire temperature maintenance process. It
includes an ON/OFF switch, manual defrost, interior light switch, LED temperature
indicator in °C or °F, a HI/LO audio/visual temperature alarm, power supply interrup-
tion, door ajar and “clean condenser” alarms. A manager’s “lock-out” feature is pro-
vided to safeguard predetermined control settings. A HAACP Event Indicator/
Memory feature announces and records up to nine (9) alarm events. Unique to the VTEMP™ are two standard modes of operation:
SUPERCOOL - Provides a lower “set-point” refrigeration condition for a set period of
time when food has just been loaded into the refrigerator and needs to be quickly
brought back down to a safe temperature.
ENERGY SAVING - The cabinet automatically reverts to the energy saving mode
when there are no door openings for four hours.
CHARACTERISTICS 2 Section
Net Capacity 21.3
Width, Overall (in.) 52 1/8
Depth, Overall (inc. Handles) 39 1/4
Depth, Door(s) Open 90° 56 3/4
Clear Door Width (in.) 21 1/8
Clear Half-Door Height (in.) 25 3/8
Clear Full-Door Height (in.) 55 1/4
Height Overall (inc. 6” legs) 84 1/4
No. Full Doors 2F, 4H
No. of Shelves 6
ELECTRICAL DATA
Cabinet Voltage 115/60/1
Feed Wires 2
Condensing Unit Voltage 115/60/1
NEMA Plug 5-15P
Total Amperes, Refrigerator 6.7
Total Amperes, Freezer 11.6
NOTE: Plug style, voltage and full load amps may var y dependi ng on certain
options selected such as optional voltages and compressor upgrades.
REFRIGERATION DATA
Condensing Unit Size, Refrigerator 1/4 HP
Condensing Unit Size, Freezer 1/2 HP
Refrigerant , Refrigerator R-134A
Refrigerant, Freezer R-404A
CRATED DIMENSIONS Height Width Depth Cu. Ft. Lbs.
Two Section 84 1/2 59 1/4 43 124.59 550
* Remote units use R-404A refrigerant standard and come with 6” legs
Note: In order to pro vide peak operating per fo rmanc e th e cabinet must have a
2 inch all around clearance and 12 inches above the top of the condensing unit. This
endures an adequate air supply and space for routine maintenance and/or service if
required.
We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for
previously purchased equipment. Dimensional tolerances +/- 1⁄4”. Metric dimensions (MM)
01/17