Victor VC60B+ Instruction Manual

- 1 -
INSULATION TESTER
INSTUCTION MANUAL
一、GENERAL
This instrument adopts the DC Voltage convertor of low consumption and high converter ratio inductance energy storage, to change the 9V Voltage to 250V/500V/1000V DC Voltage. It uses digital bridge to make the insulation resistance measurement had the features of user-friendly, high extent range, backlight display, data hold and auto power off. The whole instrument is stylish and superior grade in appearance and high stable in performance, it can be operated by both hands through using a shoulder strap. It is most suitable for the needs of insulation resistance check, such as electric, cable, electrical and mechanical equipment, telecommunication equipment and electrical facilities.
二、FRONT PANEL DESCRIPTION
1、2、3、4、Voltage selection switch(AC750V/500V/250V/1000V). 5Resistance Range selection switchRANGE. 6Power switchauto-lock power switchPOWER. 7High voltage indicatorLED display. 8、Measurement button. 9LCD displayDisplay the measured data and units
10Instrument model.
11、L: Terminal for connecting the measured circuit. 12GTerminal for protection, connect the electrode wire of
protection loop to “G” terminal when the measured
object is required to add the protection loop to eliminate the leakage effect.
13ACV: Input terminal of AC Voltage measurement. 14、E:Terminal for connecting the ground of the measured
object.
15Terminal of AC adaptor )。
三、TECHNIC PROPERTY 1General Property
(1)Display:84.8×59.8mm LCD display, max.“1999”。 (2)Over range indicator:display“1”。 (3)Power:5# battery LR6 (1.5V) ×6 (or external AC
adaptor), no battery indicator Auto power off (approx. 15miutes after turning on)
4Power consumption:consumption is less than 300mw
at unload measurement.
5Operation environmentTemperature 0°C 40°C.
Relative humidity 30%RH85RH.
6Dimension:175(L) ×110(W) ×70(D) mm。 7Weight:630 g (including batteries).
2Technical property
Measured
voltage
250V±10%
500V±10%
1000V±10%
RANGE
0.1MΩ— 20MΩ
0.1MΩ— 50MΩ
0.1MΩ—
100
20MΩ—
500MΩ
50MΩ— 1000MΩ
100MΩ—
2000MΩ
Accuracy
±(4% of reading ± 2 digits
Shot current
1.8mA
1.8mA
1.6mA
Median
resistance
2 MΩ
2MΩ
5MΩ
Terminal
position
L . E
ACV750V Accuracy:±(1.0% of reading + 6 digits). Terminal positionACV G Input impedance 1MΩ。 Frequency response:( 50200)Hz NoteMedian resistance——to ensure that the voltage of both sides of measurement is not less than 90% of lower limit of resistance measurement of measurement voltage normal value
四、OPERATION DESCRIPTION:
1Open the battery case and set up 6pcs of 5# batteries
(see the following pictures), note the polarity of batteries.
2Press the button ofPOWER. 3、Select the right voltage (250V/500V/1000V/AC750V) according
to the requirement of measurement.
4Select the right range (RANGE) (except AC750V), according to
the requirement of measurement.
5Connect the electrode of the measured object to the relative
terminal of the instrument.
6When measuring cable, connect G Terminal to the protection
loop.
7Press the button of measurement and start it, turn the
knob right to lock the button; when the value is stable, get the reading from LCD.
8Connect the input line “E” to the ground of the
measured object, and “L” to the circuit of the
measured object; require line “L” to hang in the air.
9、2000MΩ。When “1” is displayed, over range is indicated,
and should turn to the higher range to get reading; When the range button is in “ position, it expresses that the insulated resistance exceeds
2000MΩ.
10Hang the instrument on your neck to save your hands
15
- 2 -
to make measurement.
五、METHOD TO MEASURE THE INSULATED RESISTANCE
六、SAFETY NOTES:
1When voltage measurement selection button does not be
pressed, it is possible to appear the high voltage at the output voltage terminal.
2When measuring, first check the measurement voltage
selection and if the indication of the measurement voltage on LCD is in accordance with the voltage needed
3、To ensure the safety of operation, the operation cannot be
done until the measured object removed from the power supplied by the electricity grid system, and should be discharged fully to testify that the measured object does not have any danger of power.
4When measuring, it is not allowed to handle the terminal
of measurement to make sure the accuracy of reading and personal safety.
5Keep the instrument away from the high temperature
place, and from the direct sunshine to avoid affecting the life of the LCD.
6When low battery symbol of “ ” appears, please
replace the batteries in time. Take the batteries out when storage to avoid the leakage of batteries to damage the instrument.
7When unload, reading is normal, it won’t affect the
measurement.
8When measuring MΩ, if the reading is unstable, it is
likely caused by the interference of surrounding and unsteadiness of the insulated materials, it will make the
reading stable to connect the “G” terminal to the shield
side of the measured object
9To ensure the safety of measurement and reduce the
interference, the test leads adopt silicone rubber materials, please do not change the leads at will.
10When the external AC adaptor supplies the power, the
inside batteries are disconnected and the batteries can’t be charged at the time. Note: please select ( ) power supply method.
七、SETS OF INSTRUMENT
1Digital Insulation Tester 1pc 210A test leads 1set 35# battery1.5V)×6 6pcs 4Operation Manual 1copy 5Shoulder strap 1pc
八、FAULT ELIMINATION
If the instrument can’t work properly, the below
methods can help you to solve the general problems quickly.
If the fault still can’t be eliminated, please contact the
maintenance centers or distributors.
Fault
Solution
No display
Power off-please turn on the power
Replace the batteries
symbol
appearance
Replace the batteries Error value
Replace the batteries
The instruction manual is subject to change without notice. The contents in the instruction manual are considered to be
correct, if the user find any errors or pretermissions, etc., please contact the manufacturer. The manufacturer hereby will not be responsible for any
accident and damage caused by the improper operation. The functions described in this instruction manual do not be
the reason for special usage.