12
1-800-735-6200
73
Converter Specifications
(typical at TBP= 25°C, nominal line and 75% load, unless otherwise specified)
VI-J00 E-Grade VI-J00 C-, I-, M-Grade
PARAMETER MIN. TYP. MAX. MIN. TYP. MAX. UNITS TEST CONDITIONS
■ Input Characteristics
Inrush charge 60x10
-6
60x10-6100x10
-6
Coulombs Nominal line
Input reflected ripple current – pp 10% 10% I
IN
Nominal line, full load
Input ripple rejection dB 120 Hz, nominal line
dB 2400 Hz, nominal line
No load power dissipation 1.35 2 1.35 2 Watts
■ Output Characteristics
Setpoint accuracy 1.0% 2.0% 0.5% 1.0% V
NOM
Load/line regulation 0.5% 0.05% 0.2% V
NOM
LL to HL, 10% to Full Load
Load/line regulation 1.0% 0.2% 0.5% V
NOM
LL to HL, No Load to 10%
Output temperature drift 0.02 0.01 0.02 %/°C Over rated temperature
Long term drift 0.02 0.02 %/1K hours
Output ripple - pp:
2V, 3.3V 200 100 150 mV 20 MHz bandwidth
5V 5% 2% 3% 20 MHz bandwidth
10-48V 3% 0.75% 1.5% 20 MHz bandwidth
Trim range
1
50% 110% 50% 110% V
NOM
Total remote sense compensation 0.5 0.5 Volts 0.25V max. neg. leg
Current limit 105% 135% 105% 125% I
NOM
Automatic restart
Short circuit current 105% 140% 105% 130% I
NOM
■ Control Pin Characteristics
Gate out impedance 50 50 Ohms
Gate in impedance 10
3
10
3
Ohms
Gate in high threshold 6 6 Volts Use open collector
Gate in low threshold 0.65 0.65 Volts
Gate in low current 6 6 mA
■ Dielectric Withstand Characteristics
Input to output 3,000 3,000 V
RMS
Baseplate earthed
Output to baseplate 500 500 V
RMS
Input to baseplate 1,500 1,500 V
RMS
■ Thermal Characteristics
Efficiency 78-88% 80-90%
Baseplate to sink 0.4 0.4 °C/Watt With Vicor P/N 04308
■ Mechanical Specifications
Weight 3.0 (85) 3.0 (85) Ounces (Grams)
1
10V, 12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
For product compliance with agency standards please refer to pages 67 - 69.
25+20Log
(
Vin
)
Vout
30+20Log
(
Vin
)
Vout
20+20Log
(
Vin
)
Vout
Rev 3 2 of 2
For the latest Vicor Product Information: www.vicorpower.com