VICOR VI-ARM-H11, VI-ARM-C2S, VI-ARM-C22, VI-ARM-C21, VI-ARM-C1S Datasheet

...
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 1 of 12
Set your site on VICOR at www.vicorpower.com
VI-ARM
TM
Autoranging Rectifier Modules
Up to 1500 Watts
45
Features
Microprocessor controlled
VI-ARM-1
500 Watts @ 90-132Vac 750 Watts @ 180-264Vac
VI-ARM-2
1000 Watts @ 90-132Vac 1500 Watts @ 180-264Vac
96-98% Efficiency
100˚C baseplate (no derating)
UL, CSA, TÜV, VDE, BABT
AC Bus OK, module enable
Inrush limiting (no external circuitry)
CE Marked
Typical Applications: systems requiring a rugged, full featured interface to the AC mains in the smallest possible package.
Product Highlights
The ARM (Autoranging Rectifier Module) is an AC front end module which provides autoranging line rectification and inrush current limiting. The ARM is available in either 500/750W or 750/1000W models in a mini sized package measuring only 2.28" x
1.45" x 0.5".
The ARM interfaces directly with worldwide AC mains and may be used with Vicor 1st or 2nd Generation 300V input DC-DC converters to realize an autoranging, high density, low profile switching power supply. The ARM includes a microcontroller that continuously monitors the AC line to control bridge/doubler operation. The user need only provide external capacitance to satisfy system hold-up requirements.
Vicor 2nd Generation packaging technology offers flexible mounting options for various manufacturing processes. The ARM may be installed as a conventional leaded device for on-board applications, in-board for low profile, height restricted applications, socketed or surface mounted with optional ModuMate interconnect products.
Actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
Parameter Rating
VI-ARM-1/VI-ARM-2 Unit Notes
L to N 264 Vac L to N 280 Vac 100ms +Out to –Out 400 Vdc B OK to –Out 16 Vdc EN to –Out 16 Vdc Output power 500/1000 Watts 90-132Vac
750/1500 Watts 180-264Vac Mounting torque 4 - 6 (0.45 -0.68) in- lbs (N-m) 6 each, 4-40 screw Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder Pin soldering temperature 750 (390) °F (°C) <7 sec; hand solder Storage temperature, C–,& T– Grade –40 to +125 °C Baseplate Operating temperature, C–Grade –20 to +100 °C Baseplate Operating temperature, T– Grade –40 to +100 °C Baseplate
Parameter Typ Unit
Baseplate to sink; flat, greased surface 0.24 °C/Watt Baseplate to sink; with thermal pad (P/N 16495) 0.3 °C/Watt Baseplate to ambient- free convection 15 °C/Watt Baseplate to ambient; 1000 LFM- forced air 2.7 °C/Watt Thermal capacity 48 Watt-sec/°C
Product
Type 1 = 500/1000W 2 = 750/1500W
Pin Style*
1 = Short
2 = Long S=Short Modumate N=Long Modumate
Product Grade C = –20°C to +100°C T = –40°C to +100°C H = –40°C to +100°C M = –55°C to +100°C
Thermal Resistance and Capacity
Absolute Maximum Ratings
Part Numbering
*Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting.
VI-ARM- C 1 2
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 2 of 12
Set your site on VICOR at www.vicorpower.com
VI-ARM - 1 VI-ARM - 2
Parameter Min Typ Max Min Typ Max Unit Notes
Operating input voltage 90 132 90 132 Vac Autoranging (doubler mode) Operating input voltage 180 264 180 264 Vac Autoranging (bridge mode) Input undervoltage 90 90 Vac No damage Input surge withstand 280 280 Vac 100ms AC line frequency 47 63 47 63 Hz C-Grade AC line frequency 47 880 47 880 Hz T-Grade Input current, rms 0 7.4 0 14.8 Amps 120Vac Input current, rms 0 5.4 0 10.8 Amps 240Vac Power factor 0.60 0.60 Typical line voltage condition Inrush current 30 60 Amps 264Vac peak line, cold start Holdup capacitance 1600 3300 µF
SAFETY SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to 5% total harmonic distortion.
VI-ARM - 1 VI-ARM - 2
Parameter Min Typ Max Min Typ Max Unit Notes
Output power 0 500 0 1000 Watts 90-132Vac Output power 0 750 0 1500 Watts 180-264Vac Efficiency, 120Vac 94 96 94 96 % Efficiency, 240Vac 96 98 96 98 % Output voltage 200 375 200 375 Vdc 90-264Vac
Parameter Min Typ Max Unit Notes
Agency approvals
UL 1950, CSA 22.2 No.950,
TÜV, VDE, EN60950, CE Marked Isolation voltage (in to out) None Isolation provided by DC-DC converter(s) Isolation voltage (I/O to baseplate) 1500 Volts, rms Leakage current 100 µA No filter
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 3 of 12
Set your site on VICOR at www.vicorpower.com
Electrical Characteristics, continued
MODULE CONTROL SPECIFICATIONS
MODULE GENERAL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC Bus OK (B OK)
On-state resistance (low) 15 To negative output - bus normal On-state current (low) -50 mA Bus normal Off-state voltage 14.8 15.0 15.2 Vdc Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10) On-state threshold 235 240 245 Vdc Output bus voltage Off-state threshold 200 205 210 Vdc Output bus voltage
Module Enable (EN)
On-state resistance (low) 15 To negative output - converters are disabled On-state current (low) 50 mA Off-state voltage 14.8 15.0 15.2 Vdc 150K internal pull up to 15Vdc (Fig. 9) On-state threshold 235 240 245 Vdc Output bus voltage
Off-state threshold 200 205 210 Vdc Output bus voltage Over voltage shutdown 380 390 400 Vdc AC Bus OK - module enable, differential error* 15 17 20 Vdc AC Bus OK and module enable thresholds track
Parameter Min Typ Max Unit Notes
MTBF >1,000,000 hours 25˚C, ground benign Baseplate material Aluminum Cover Polyetherimide Pin material Copper, tin/lead solder dipped Weight 2.1 (60) ounces (grams)
Size
2.28 x 1.45 x 0.5 inches
(57,9 x 36,8 x 12,7) (mm)
* Tracking error between BUS OK and Enable thresholds
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 4 of 12
Set your site on VICOR at www.vicorpower.com
Operating Characteristics
Figure 1—Start-up at 120Vac input
Figure 3—Power down, from 120Vac Figure 4—Power down, from 240Vac
Figure 2—Start-up at 240Vac input
Vdc output
Strap Engaged
Iac input @2A / mV
Iac input @2A / mV
Enable
Enable
B OK
Vdc output
Enable
B OK
Vdc output
Enable
B OK
Vdc output
Enable
B OK
Figure 5—Output overvoltage protection 240Vac range
Vdc output
Enable
B OK
Loading...