Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 1 of 12
Set your site on VICOR at www.vicorpower.com
VI-ARM
TM
Autoranging Rectifier Modules
Up to 1500 Watts
45
Features
• Autoranging input
• Microprocessor controlled
• VI-ARM-1
500 Watts @ 90-132Vac
750 Watts @ 180-264Vac
• VI-ARM-2
1000 Watts @ 90-132Vac
1500 Watts @ 180-264Vac
• 96-98% Efficiency
• 100˚C baseplate (no derating)
• UL, CSA, TÜV, VDE, BABT
• AC Bus OK, module enable
• Inrush limiting (no external circuitry)
• CE Marked
Typical Applications: systems requiring a
rugged, full featured interface to the AC
mains in the smallest possible package.
Product Highlights
The ARM (Autoranging Rectifier Module)
is an AC front end module which provides
autoranging line rectification and inrush
current limiting. The ARM is available in
either 500/750W or 750/1000W models in a
mini sized package measuring only 2.28" x
1.45" x 0.5".
The ARM interfaces directly with
worldwide AC mains and may be used with
Vicor 1st or 2nd Generation 300V input
DC-DC converters to realize an
autoranging, high density, low profile
switching power supply. The ARM includes
a microcontroller that continuously
monitors the AC line to control
bridge/doubler operation. The user need
only provide external capacitance to satisfy
system hold-up requirements.
Vicor 2nd Generation packaging technology
offers flexible mounting options for various
manufacturing processes. The ARM may be
installed as a conventional leaded device
for on-board applications, in-board for low
profile, height restricted applications,
socketed or surface mounted with optional
ModuMate interconnect products.
Actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
Parameter Rating
VI-ARM-1/VI-ARM-2 Unit Notes
L to N 264 Vac
L to N 280 Vac 100ms
+Out to –Out 400 Vdc
B OK to –Out 16 Vdc
EN to –Out 16 Vdc
Output power 500/1000 Watts 90-132Vac
750/1500 Watts 180-264Vac
Mounting torque 4 - 6 (0.45 -0.68) in- lbs (N-m) 6 each, 4-40 screw
Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder
Pin soldering temperature 750 (390) °F (°C) <7 sec; hand solder
Storage temperature, C–,& T– Grade –40 to +125 °C Baseplate
Operating temperature, C–Grade –20 to +100 °C Baseplate
Operating temperature, T– Grade –40 to +100 °C Baseplate
Parameter Typ Unit
Baseplate to sink; flat, greased surface 0.24 °C/Watt
Baseplate to sink; with thermal pad (P/N 16495) 0.3 °C/Watt
Baseplate to ambient- free convection 15 °C/Watt
Baseplate to ambient; 1000 LFM- forced air 2.7 °C/Watt
Thermal capacity 48 Watt-sec/°C
Product
Type
1 = 500/1000W
2 = 750/1500W
Pin Style*
1 = Short
2 = Long
S=Short Modumate
N=Long Modumate
Product Grade
C = –20°C to +100°C
T = –40°C to +100°C
H = –40°C to +100°C
M = –55°C to +100°C
Thermal Resistance and Capacity
Absolute Maximum Ratings
Part Numbering
*Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting.
VI-ARM- C 1 2

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 2 of 12
Set your site on VICOR at www.vicorpower.com
VI-ARM - 1 VI-ARM - 2
Parameter Min Typ Max Min Typ Max Unit Notes
Operating input voltage 90 132 90 132 Vac Autoranging (doubler mode)
Operating input voltage 180 264 180 264 Vac Autoranging (bridge mode)
Input undervoltage 90 90 Vac No damage
Input surge withstand 280 280 Vac 100ms
AC line frequency 47 63 47 63 Hz C-Grade
AC line frequency 47 880 47 880 Hz T-Grade
Input current, rms 0 7.4 0 14.8 Amps 120Vac
Input current, rms 0 5.4 0 10.8 Amps 240Vac
Power factor 0.60 0.60 Typical line voltage condition
Inrush current 30 60 Amps 264Vac peak line, cold start
Holdup capacitance 1600 3300 µF
SAFETY SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply
for AC mains having up to 5% total harmonic distortion.
VI-ARM - 1 VI-ARM - 2
Parameter Min Typ Max Min Typ Max Unit Notes
Output power 0 500 0 1000 Watts 90-132Vac
Output power 0 750 0 1500 Watts 180-264Vac
Efficiency, 120Vac 94 96 94 96 %
Efficiency, 240Vac 96 98 96 98 %
Output voltage 200 375 200 375 Vdc 90-264Vac
Parameter Min Typ Max Unit Notes
Agency approvals
UL 1950, CSA 22.2 No.950,
TÜV, VDE, EN60950, CE Marked
Isolation voltage (in to out) None Isolation provided by DC-DC converter(s)
Isolation voltage (I/O to baseplate) 1500 Volts, rms
Leakage current 100 µA No filter

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 3 of 12
Set your site on VICOR at www.vicorpower.com
Electrical Characteristics, continued
MODULE CONTROL SPECIFICATIONS
MODULE GENERAL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC Bus OK (B OK)
On-state resistance (low) 15 Ω To negative output - bus normal
On-state current (low) -50 mA Bus normal
Off-state voltage 14.8 15.0 15.2 Vdc Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10)
On-state threshold 235 240 245 Vdc Output bus voltage
Off-state threshold 200 205 210 Vdc Output bus voltage
Module Enable (EN)
On-state resistance (low) 15 Ω To negative output - converters are disabled
On-state current (low) 50 mA
Off-state voltage 14.8 15.0 15.2 Vdc 150K internal pull up to 15Vdc (Fig. 9)
On-state threshold 235 240 245 Vdc Output bus voltage
Off-state threshold 200 205 210 Vdc Output bus voltage
Over voltage shutdown 380 390 400 Vdc
AC Bus OK - module enable, differential error* 15 17 20 Vdc AC Bus OK and module enable thresholds track
Parameter Min Typ Max Unit Notes
MTBF >1,000,000 hours 25˚C, ground benign
Baseplate material Aluminum
Cover Polyetherimide
Pin material Copper, tin/lead solder dipped
Weight 2.1 (60) ounces (grams)
Size
2.28 x 1.45 x 0.5 inches
(57,9 x 36,8 x 12,7) (mm)
* Tracking error between BUS OK and Enable thresholds

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 ARM, Autoranging Rectifier Module Rev. 2.4 Page 4 of 12
Set your site on VICOR at www.vicorpower.com
Operating Characteristics
Figure 1—Start-up at 120Vac input
Figure 3—Power down, from 120Vac Figure 4—Power down, from 240Vac
Figure 2—Start-up at 240Vac input
Vdc output
Strap
Engaged
Iac input @2A / mV
Iac input @2A / mV
Enable
Enable
B OK
Vdc output
Enable
B OK
Vdc output
Enable
B OK
Vdc output
Enable
B OK
Figure 5—Output overvoltage protection 240Vac range
Vdc output
Enable
B OK
➞