VICOR VI-2WZEX, VI-2WYMX, VI-2WYEX, VI-2WYIX, VI-2WYCX Datasheet

...
12
1-800-735-6200
70
Product Grade/ Product Grade/
Operating Temp. Storage Temp.
E = -10°C to +85°C E = -20°C to +100°C C = -25°C to +85°C C = -40°C to +100°C I = -40°C to +85°C I = -55°C to +100°C M = -55°C to +85°C M = -65°C to +100°C
Overtemperature shutdown 95°C typical
(recycle power to restart).
VI-2
Mechanical Drawing
Features
Up to 50W/Cubic Inch
UL, CSA, TÜV, VDE, BABT,
AUSTEL
Up to 90% Efficiency
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7)
Remote Sense and Current Limit
OVP, Thermal Shutdown
Logic Disable
Wide Range Output Adjust
Compatible Power Booster Modules
ZCS Power Architecture
Low Noise FM Control
CE Marked
VI-200
DC-DC Converters 50 to 200 Watts
Product Highlights
The VI-200 Family, with over 8 million shipped, is Vicor’s first generation of “zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2 MHz, VI-200 Family Converters offer exceptional power density, efficiency, noise performance, reliability and ease of use. Power Boosters provide a simple, cost effective, off-the-shelf solution for higher power output requirements. One or more boosters may be used to create synchronous arrays capable of supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power VI-J00 MiniMods. (pg. 72)
Packaging Options
SlimMods™, high power density, flangeless packages and FinMods™, featuring integral finned heatsinks.
SlimMod: Option suffix: - S Example: VI - 2XX - XX- S FinMod: Option suffix: - F1 and - F2
Examples: VI - 2XX - XX -F1, 0.75" height VI - 2XX - XX -F2, 1.00" height
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(1) 75W 75W 15A (2) 150W 150W 30A (3) 100W 100W 20A
* Brownout 75% of rated load; transient voltage for 1 second.
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(4) 200W 200W 40A (5) 150W 200W 40A (6) 75W 100W 20A
Output Power/Current
V
OUT
5V V
OUT
< 5V
Y = 50W Y = 10A X = 75W X = 15A
W = 100W W = 20A
V = 150W V = 30A U = 200W U = 40A
For additional output power use “Boosters”.
Change (VI-2xx-xx) to (VI-Bxx-xx).
Output Voltage
Z = 2V 2 = 15V Y = 3.3V N = 18.5V 0 = 5V 3 = 24V X = 5.2V L = 28V W= 5.5V J = 36V V = 5.8V K = 40V T = 6.5V 4 = 48V R = 7.5V H = 52V M = 10V F = 72V 1 = 12V D = 85V P = 13.8V B = 95V
Input Voltage
Nominal Range Brownout
/
Transient
*
0 = 12V 10 - 20V (1) n/a 22V 1 = 24V 21 - 32V (4) 18V 36V
W = 24V 18 - 36V (2) n/a n/a
2 = 36V 21 - 56V (3) 18V 60V 3 = 48V 42 - 60V (4) 36V 72V N = 48V 36 - 76V (4) n/a n/a 4 = 72V 55 - 100V (4) 45V 110V T = 110V 66 - 160V (2) n/a n/a 5 = 150V 100 - 200V (5) 85V 215V 6 = 300V 200 - 400V (4) 170V 425V 7 = 150/300V 100 - 375V (6) 90V n/a
+.030 (0,76)
-.000 (0)
Product ID this surface
FULL R
5
6
7
8
9
4 3
2
1
Pin #
1 2 3 4 5 6* 7* 8* 9
Function
+In
Gate In Gate Out
-In +Out
+Sense Trim
-Sense
-Out
* Do not connect on Booster modules
Aluminum Base
.01
.040 (1,0) Dia (7) places Solder plate over copper alloy
.080 (2,0) Dia (2) places Solder plate over copper alloy
.30±.015
(7,6)±(0,38)
1.80
(45,7)
(106,7)
(12,7)
(5,6) MIN
(3,0)
(116,8)
(61,0)
(44,5)
(7,6) Min
.15
(3,8)
2.10
(53,3)
.40
(10,2)
.35±.015
(8,9)±(0,38)
1.40
(35,6)
1.00
(25,4)
.70
(17,8)
(91,4)
.50
(12,7)
VI-200
4.60
3.60
.15
(3,8)
4.20
.12
.22
.50
.30
2.40
1.75
Rev 3 1 of 2
For the latest Vicor Product Information: www.vicorpower.com
12
1-800-735-6200
71
VI-200 E-Grade VI-200 C-, I-, M-Grade
PARAMETER MIN. TYP. MAX. MIN. TYP. MAX. UNITS TEST CONDITIONS
Input Characteristics
Inrush charge 120x10
-6
120x10-6200x10
-6
Coulombs Nominal line
Input reflected ripple current – pp 10% 10% I
IN
Nominal line, full load
Input ripple rejection dB 120 Hz, nominal line
dB 2400 Hz, nominal line
No load power dissipation 1.35 2 1.35 2 Watts
Output Characteristics
Setpoint accuracy 1% 2% 0.5% 1% V
NOM
Load/line regulation 0.5% 0.05% 0.2% V
NOM
LL to HL, 10% to Full Load
Load/line regulation 1% 0.2% 0.5% V
NOM
LL to HL, No Load to 10% Output temperature drift 0.02 0.01 0.02 % / °C Over rated temp. Long term drift 0.02 0.02 %/1K hours Output ripple - pp:
2V, 3.3V 150 mV 60 mV 100 mV 20 MHz bandwidth 5V 5% 2% 3% 20 MHz bandwidth 10-48V 3% 0.75% 1.5% 20 MHz bandwidth
Trim range
1
50% 110% 50% 110% Total remote sense compensation 0.5 0.5 Volts 0.25V max. neg. leg OVP set point 125%
2
115% 125%2135% V
NOM
Recycle power
Current limit 105% 135% 105% 125% I
NOM
Automatic restart
Short circuit current
3
20% 140% 20% 130% I
NOM
Control Pin Characteristics
Gate out impedance 50 50 Ohms Gate in impedance 10
3
10
3
Ohms Gate in open circuit voltage 6 6 Volts Use open collector Gate in low threshold 0.65 0.65 Volts Gate in low current 6 6 mA Power sharing accuracy 0.95 1.05 0.95 1.05
Dielectric Withstand Characteristics
Input to output 3,000 3,000 V
RMS
Baseplate earthed
Output to baseplate 500 500 V
RMS
Input to baseplate 1,500 1,500 V
RMS
Thermal Characteristics
Efficiency 78-88% 80-90% Baseplate to sink 0.2 0.2 °C/Watt With Vicor P/N 01777
Thermal shutdown
4
90 95 105 90 95 105 °C Cool and recycle power
(Drivers only)
to restart
Mechanical Specifications
Weight 6.0 (170) 6.0 (170) Ounces (Grams)
1
10V, 12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
2
131% nominal for booster modules.
3
Output voltages of 3.3V or 5V incorporate foldback current limiting; all other outputs provide constant current limiting.
4
No overtemp protection in booster modules.
Converter Specifications
(typical at TBP= 25°C, nominal line and 75% load, unless otherwise specified)
25+20Log
(
Vin
)
Vout
30+20Log
(
Vin
)
Vout
20+20Log
(
Vin
)
Vout
Rev 3 2 of 2
For the latest Vicor Product Information: www.vicorpower.com
Loading...