VICOR PowerBench PMBus User Manual

Page 1
USER GUIDE | UG:402
PMBus Interface and Accessories User Guide
Jon Siegers Ankur Patel Applications Engineering
Contents Page
Introduction 1
Connector Information ­PMBus™-USB Adapter 3
Application Details 4
Features 4
VIA to Adapter Bridge Board 5
GUI Configuration 8

Introduction

The PMBus™-USB Adapter (I2C-ADAPTER-A00) allows users to communicate with PMBus-version Vicor power modules through the signal pins. A PMBus control interface is provided for digital management and access to telemetry monitoring offered by the product. The PMBus to USB Adapter converts the PMBus to USB communication protocol by an internal isolated controller that allows users to easily connect to a host PC (no driver installation required on Windows). A GUI, available for download on the Vicor website, is provided for users to easily monitor and control the power module.
The PMBus interface of a VIA, a dedicated Digital Supervisor or Point-of-Load Isolator is used for communication purposes with the provided GUI installed on the user’s PC.
The PMBus interface of a VIA, Digital Supervisor or PLI allows users to read and write into the status configuration registers of the module, monitor faults and obtain other additional device information. The PMBus-USB adapter provides the ability to demonstrate the PMBus digital interface offered on select Vicor products in an evaluation environment.
UG:402 Page 1
Page 2
IMPORTANT NOTICE:
Hazardous voltages may be present on the interfaced Vicor power module.
PERSONAL CONTACT WITH LINE VOLTAGE MAY RESULT IN SEVERE INJURY, DISABILITY, OR DEATH. IMPROPER OR UNSAFE HANDLING OF THIS ACCESSORY AND REL ATED POWER MODULE(S) MAY RESULT IN SERIOUS INJURY OR DEATH
Read the precautions below entirely BEFORE using the PMBus-USB Adapter. Do not operate the PMBus to USB Adapter unless you have the appropriate safety precautions in place on your bench to guarantee safety.
The list below is not comprehensive and is not a substitute for common sense and good practice.
During operation, the power devices and surrounding structures can be operated safely at high
temperatures.
Remove power from converter and use caution when connecting and disconnecting test probes and
interface lines to avoid inadvertent short circuits and contact with hot surfaces.
Never use a jumper in place of the fuse.
When testing electronic products always use approved safety glasses. Follow good laboratory practice
and procedures.
Avoid creating ground loops when making measurements of the isolated input or output voltage and
signals.
Care should be taken to protect the user from accidental contact when under power.
Care should be taken to avoid reversing polarities if connecting to the opposite (solder) side of the
board.
The PMBus to USB Adapter described in this document is designed for general laboratory evaluation,
and is not suitable for installation in end user equipment.
Refer to the specific Vicor power module data sheet of the interfaced product(s) for electrical,
thermal, and mechanical product details.
Signal cables 43503-01 and 43503-02 are rated up to five insertions and extractions. Insert and
extract the VIA signal connector cables by firmly grasping the connector body housing. To avoid unnecessary stress on the connector, the cable should be appropriately strain relieved.
UG:402 Page 2
Page 3
Connector Information – PMBus™-USB Adapter
r
Side View
1
VDDB
2
SDA
3
SCL
4
SGND
5
SGND
6
Chassis
GND
Micro-USBConnecto
Pin Number Signal Name Typ e Function
1
2
3 SCL OUTPUT I2C Clock PMBus Compatible
4 SGND SIGNAL RETURN Signal Ground
5 SGND SIGNAL RETURN Signal Ground
6 Chassis GND SHIELD Connector Housing Ground
VDDB OUTPUT 5V supply output
SDA INPUT/OUTPUT I2C™ Data PMBus™ Compatible
Figure 1
Host PC to VIA™ Power Module
Array Connection, PMBus
Communication Interface
Accessories Shown as a Typical
Application Setup
HostPC and GUI
PMBus™ to USB Adapter
(I2C-ADAPTER-A00)
ISOLATION BOUNDARY
VIAto Adapter Bridge
BoardCable
(43503-01)
Adapter BridgeBoard
(USB-ADAPTER-4V-A00)
VIA
VIA
VIA
VIA
UG:402 Page 3
Page 4

Application Details

The PMBus™-USB Adapter, along with the listed companion accessories and Vicor Digital Interface Demo GUI, provides a convenient means to demonstrate the PMBus digital interface offered on Vicor power modules in an evaluation environment. With these tools, the user can quickly get started with evaluating the features offered by the PMBus interface and determining needs of the final production power system.

Features

Easily configure and monitor PMBus enabled Vicor power modules
Vicor Digital Interface Demo Board GUI for PMBus control interface
(available on Vicor website HV BCM family page)
USB connection to host PC
Provides 5V external bias (VDDB)
Isolated PMBus to host interface (4242VDC)
Measurement of input and output parameters, including but not limited to:
Voltage
Current
Power
Temperature
Fault monitoring, including but not limited to:
Overvoltage / Undervoltage
Overcurrent
Overtemperature
Enable / Disable control
Table 1
PMBus Companion Accessories
Part Number Description
USB-ADAPTER-1V-B00
USB-ADAPTER-4V-A00
43503-01 VIA Signal Connector cable with Molex® Micro-Lock™ connector (600mm length)
43503-02 VIA Signal Connector cable with Molex® Micro-Lock™ connector (200mm length)
I2C-ADAPTER-A00 PMBus-USB Adapter
Software Interface Vicor digital interface demo board GUI
Adapter bridge board, for use with single chassis-mount VIA
Adapter bridge board, for use with up to four chassis-mount VIAs
UG:402 Page 4
Page 5
Figure 2
USB-ADAPTER-1V-B00
Assembly Drawing and
Schematic
VIA™ to Adapter Bridge Board
The Typical Application diagram in Figure 1 shows the connections required to establish PMBus communication between PMBus-enabled VIA modules and a host PC. The setup for this configuration includes directly connecting the VIA Signal Connector cable to the PMBus signal port on the VIA. The Adapter Bridge Board, as shown in Figure 2 and Figure 3, provides the necessary connections between the VIA Signal Connector Cable and the PMBus to USB Adapter. On Adapter Bridge Board USB-ADAPTER-1V-B00, the VIA PMBus address is programmed to 51h by a pre-installed resistor R02. On the Adapter Bridge Board USB-ADAPTER-4V-A00, the four VIA PMBus addresses are programmed to 51h, 53h, 54h, 55h by pre-installed resistors R02-R05. An LED provides visual indication that VDDB (5V) is present.
Lastly, the PMBus to USB Adapter connects to the user’s computer where the provided Vicor Digital Interface Demo GUI is installed.
FID02
C01
R01
D01
R02
R06
R05
J01
1 2 3 4 5
6
Chassis
MICRO USB Connector
R08 0402
CHASSIS
J01
R08
R04
TOP VIEW
R05
VDDE SDA SCL
GND
R04 0402 0402
GND
0402
R01
0402
C01
0402
GND
FID01
J02
GND
ADDRESS
R02
R06 0402
D01
J02
1
2
3
4
5
Micro-Lock Connector
UG:402 Page 5
Page 6
Figure 3 USB-ADAPTER-4V-A00 Assembly Drawing and
Schematic
J03
J04
J05
J02
FID02
ADDRESS_1
GND
R03
R04
R08
D01
R01
R05
R09
R06
R07
C01
J01
R02
FID01
TOP VIEW
ADDRESS_1
SDA
ADDRESS_2
ADDRESS_3
ADDRESS_4
R02
R03
R04
0402
0402
GND
VDDE
R08 0402
D01
GND
R05
0402
0402
GND
GND
CHASSIS
J01
1 2 3 4 5
6
Chassis
MICRO USB Connector
VDDE
SDA
SCL
R01 0603
R09 0402
SGND
R07
0402
C01
0402
R06 0402
GND
VDDE
SCL
SGND
VDDEADDRESS_2 SDA SCL SGND
VDDEADDRESS_3 SDA SCL SGND
VDDEADDRESS_4 SDA SCL SGND
J02
1
2
3
4
5
Micro-Lock Connector
J03
1
2
3
4
5
Micro-Lock Connector
J04
1
2
3
4
5
Micro-Lock Connector
J05
1
2
3
4
5
Micro-Lock Connector
UG:402 Page 6
Page 7
The following is a list of all connectors and components present on the USB-ADAPTER-1V-B00 and USB-ADAPTER-4V-A00 Adapter Bridge Boards.
Table 2
USB-ADAPTER-1V-B00
Components
Table 3
USB-ADAPTER-4V-A00
Components
Reference
Designator
R04, R05, R08 RES 0Ω 1/16W 1% 0402 KOA Speer RK73Z1ETTP
R06 RES 1kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1001F
R01 RES 10kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1002F
R02 RES 1.05kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1051F
C01 CAP X7R 0.1µF 10% 16V 0402 Murata GRM155R71C104KA88D
D01
J01 CONN MICRO-B USB SMD TE Connectivity 2174507-2
J02
Reference
Designator
R01 RES 0Ω JUMPER 1A 0603 KOA Speer RK73Z1JTTD
R06, R09 RES 0Ω 1/16W 1% 0402 KOA Speer RK73Z1ETTP
R08 RES 1kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1001F
R07 RES 10kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1002F
R02 RES 1.05kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP1051F
R03
R04 RES 3.92kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP3921F
R05 RES 5.23kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP5231F
C01 CAP X7R 0.1µF 10% 16V 0402 Murata GRM155R71C104KA88D
D01 DLED RED SMD 0402 Panasonic LNJ247W82RA
J01 CONN MICRO-B USB SMD TE Connectivity 2174507-2
J02, J03, J04, J05
Description Manufacturer
DLED RED SMD 0402 Panasonic LNJ247W82RA
CONN MICRO HDR 5POS 1.25mm
SINGLE ROW RA
Description Manufacturer
RES 2.8kΩ 1/16W 1% 0402 KOA Speer RK73H1ETTP2801F
CONN MICRO HDR 5POS 1.25mm SINGLE ROW RA
Molex 504195-0570
Molex 504195-0570
Manufacturer Part Number
Manufacturer Part Number
UG:402 Page 7
Page 8
Figure 4
GUI Configuration
GUI Configuration
Figure 4.1
Figure 4.2
After making the necessary connections, follow the guidelines for configuring the GUI and to ensure establishment of communication between the power module and the host PC.
1. Measure 5V on the VDDB pin of the VIA module to ensure power is provided to the digital communication interface. If using an evaluation board, provide 5V VDDB from an external source.
2. Power up module within operating range specified by the device datasheet.
3. Open the Vicor Digital Interface Demo Board software installed on the connected host PC.
4. Go to Tools -> Scan for Digital Supervisor to detect digital supervisor as shown in Figure 4.1.
5. Go to Tools -> Scan for Devices and select desired power module device as shown in Figure 4.2.
6. Verify the desired power module device is selected (highlighted in green) for communication
through the GUI.
UG:402 Page 8
Page 9
Limitation of Warranties
Information in this document is believed to be accurate and reliable. HOWEVER, THIS INFORMATION IS PROVIDED “AS IS” AND WITHOUT ANY WARRANTIES, EXPRESSED OR IMPLIED, AS TO THE ACCURACY OR COMPLETENESS OF SUCH INFORMATION. VICOR SHALL HAVE NO LIABILITY FOR THE CONSEQUENCES OF USE OF SUCH INFORMATION. IN NO EVENT SHALL VICOR BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR SAVINGS, BUSINESS INTERRUPTION, COSTS RELATED TO THE REMOVAL OR REPLACEMENT OF ANY PRODUCTS OR REWORK CHARGES).
Vicor reserves the right to make changes to information published in this document, at any time and without notice. You should verify that this document and information is current. This document supersedes and replaces all prior versions of this publication.
All guidance and content herein are for illustrative purposes only. Vicor makes no representation or warranty that the products and/or services described herein will be suitable for the specified use without further testing or modification. You are responsible for the design and operation of your applications and products using Vicor products, and Vicor accepts no liability for any assistance with applications or customer product design. It is your sole responsibility to determine whether the Vicor product is suitable and fit for your applications and products, and to implement adequate design, testing and operating safeguards for your planned application(s) and use(s).
VICOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT, LIFE-CRITICAL OR SAFETY-CRITICAL SYSTEMS OR EQUIPMENT. VICOR PRODUCTS ARE NOT CERTIFIED TO MEET ISO 13485 FOR USE IN MEDICAL EQUIPMENT NOR ISO/TS16949 FOR USE IN AUTOMOTIVE APPLICATIONS OR OTHER SIMILAR MEDICAL AND AUTOMOTIVE STANDARDS. VICOR DISCLAIMS ANY AND ALL LIABILITY FOR INCLUSION AND/OR USE OF VICOR PRODUCTS IN SUCH EQUIPMENT OR APPLICATIONS AND THEREFORE SUCH INCLUSION AND/OR USE IS AT YOUR OWN RISK.
Terms of Sale
The purchase and sale of Vicor products is subject to the Vicor Corporation Terms and Conditions of Sale which are available at: (http://ww w.vicorpower.com/termsconditionswarranty)
Export Control
This document as well as the item(s) described herein may be subject to export control regulations. Export may require a prior authorization from U.S. export authorities.
Contact Us: http://ww w.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
11/17
©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
Molex is a registered trademark of Molex, LLC. Micro-Lock is a trademark of Molex, LLC.
I2C™ is a trademark of NXP semiconductor.
PMBus™ name, SMIF, Inc. and logo are trademarks of SMIF, Inc.
All other trademarks, product names, logos and brands are property of their respective owners.
Rev 1.0 Page 9
Loading...